| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹60.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹63.2 L+₹1.2 L (1.96%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹69.5 L+₹7.5 L (12.1%)Rejected-Finance PO HASIMARA NEW MARKET DISTT ALIPURDUAR STATE WEST BENGAL PIN 735215 | ALIPURDUAR | WEST BENGAL | 735215 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹77.5 L+₹15.5 L (25.0%)Rejected-Finance C O BIKASH CHAKRABORTY OPPOSITE GITAM NURSERY SCHOOL NEAR BAGHAJATIN PARK PO SILIGURI DISTT DARJEELING WEST BENGAL 734401 | DARJEELING | WEST BENGAL | 734401 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹79.0 L+₹17.0 L (27.5%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹90 L
EMD Value
₹1.6 L
Closing Date
7 Mar 2022, 6:00 pmClosed
CWE Bengdubi
Headquarters Commander Works Engineers Bengdubi, Post - Bengdubi Distt - Darjeeling (WB) PIN- 734424
REPAIR/ MAINTENANCE OF ELECTRICAL DISTRIBUTION SYSTEM, STREET LIGHT FITTINGS AND OTHER CONNECTED WORKS AT SUKNA MIL STN UNDER GE SUKNA
2021_MES_471260_1
8115/S/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
GE Sukna
As per tender documents
8 documents required · 8 mandatory
₹1,000
GE Sukna
₹1.6 L
Yes
25 Apr 2022
28 Aug 2021
14 Mar 2022
28 Aug 2021
7 Mar 2022
18 Sept 2021
Amount
Surface dressing n exc 15 cm deep and getting out in soft & loose soil including disposing of the soil, spoil, etc outside the premises, complete all as specified and directed.
Excavation in trenches, not exceding 1.5 m wide and not exceeding 1.5 m in depth for foundation, laying of cable, pipe etc and n. exc 10 Sqm on plan and n exc 1.5 m in depth for shafts, wells, manholes etc and getting out in soft/ loose soil, complete all as specified and directed.
All as per Item No 2 above but depth exceeding 1.5 metre and not exceeding 3.00 metre
Returning, filling in, with approved earth after removal of grass, vegetation etc including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed.
Removing excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the staring point, complete all as specified and directed.
M&L for PCC type D-2 (1:4:8) using 40mm graded stone aggregate in foundations, filling and mass concrete, complete all as specified and directed.
Demolition of brick work or rubbled stone masonry including all quoins, arches , pillars etc built in cement mortar including disposing off the retrieved debris outside the premises, complete all as specified and as directed.
M&L for Brickwork with flyash bricks [old size bricks of class designation 75 (i.e of average compressive strength 75 kgf/cm2)], straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and directed.
Use and waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffints (if any) of foundation and plinth beams, and similar work, vertical or to batter for rough finished flat surfaces of concrete, complete all as specified and directed.
Use and waste of Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished, square, rectangular or polygonal surfaces of concrete , complete all as specified and directed.
Use and waste of formwork to Beams, cantillevers, bressumers, lintels, shelves and similer items for rough finished flat surface of concrete, complete all as specified and as directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position, not otherwise specifically provided for and including removing debries out side the premises, complete all as specified and directed.
M&L for reinforced cement concrete (1:11/2:3) type A-1 (using 20 mm graded stone aggregate), in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under-reamed piles and mass concrete, complete all as specified and directed. Note: Reinforcement and Formwork shall be measured and paid separately under relevant items.
M&L for reinforced cement concrete (1:11/2:3) type A-1 (using 20 mm graded stone aggregate), in columns, pillars, piers, posts and struts, complete all as specified and directed. Note: Reinforcement and Formwork shall be measured and paid separately under relevant items.
M&L for reinforced cement concrete (1:11/2:3) type A-1 (using 20 mm graded stone aggregate), in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and directed. Note: Reinforcement and Formwork shall be measured and paid separately under relevant items.
M&L for reinforced cement concrete (1:11/2:3) type, A-1 (using 20 mm graded stone aggregates) as in lintel bands, lintels & beams upto 1.5 metre clear span and the like including use & waste of form work, complete all as specified and as directed. Note:- Reinforcement shall be measured and paid for seperately.
M&L for rendering 15 mm thick in CM (1:4) on brick work or concrete surface finsihed even and smooth (without using extra cement) mixed with water proofing compound as per manufacturer instructions, complete all as specified and as directed. Note:- WPC shall be measured and paid seperately.
M&L for rendering 15 mm thick in CM (1:6) on the surfaces of brick work or concrete, finsihed even and smooth without using extra cement, complete all as specified and as directed.
Supply only liquid water proofing compound, complete all as specified and as directed.
M&L for hardcore of borken stone or boulders, n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level) including disposing off the debris outside the premises, complete all as specified and directed.
M&L for cement concrete type D-2 (1:4:8), 150 mm thick, using 40 mm graded stone aggregate as in sub-bases of floor etc, complete all as specified and directed.
M&L for 100 mm thick cement concrete type B-2 (1:2:4) using 40mm graded stone aggregate, as in floor and finished even & smooth without using extra cement, complete all as specified and directed.
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for conlumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
M&L for mild steel TMT bars 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for conlumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
All as per Item No 25 above but 5mm dia and over upto and including 10 mm dia in stirrups, spacers and binders, complete all as specified and directed.
S&F aluminum dividing strips, 38 mm width and 1.5 mm thick, insterted in position, conform to design complete all as specified and directed.
Dismantling timber scantlings (unframed work) 40 Sq.cm and over in section, in any position, complete all as sepecified and directed.
S&F mild steel work in tubular trusses, purlins, rafters & similar work, including special shaped washers etc. complete using ERW or induction butt welded tubes, conforming to IS 1161-1979 grade St-240, also including necessary welding and applying one shop coat of zinc chromate primer after preparation of surfaces, complete all as specified and directed.
S&F rolled section as in framing for cladding, glazing, angle cleats, mild steel plates and the like, conforming to Fe-410-W (Gde E-250) quality 'A' including necessary welding etc, complete all as specified and directed.
Dimantling of Asbestos cement (corrugated, semi corrugated etc.) sheets in roof coverings including ridges etc, complete all as specified and as directed.
S&F pre-painted colored trapezoidal profiled Galvalume/Zincalume sheet with min 0.50mm TCT confirming to IS-513 (AZ-150 GSM, AL Zn alloy metalic coating, 550 MPA yield stress as per AS-1397), colour /exterior coat of silicon modified polyster/ BHP X RW paint system 20 micron top coat applied over 5 micron primer and a 5 micron polyster back coat applied over 5 micron primer, as in roof covering/ cladding to wall, fixed with and including Galvanised self drilling self-tapping fastener (12-14 x 55 with EPDM seals), complete all as specified and directed.
S&F pre-painted colored plain sheet profiled Galvalume/Zincalume sheet with min 0.50mm TCT confirming to IS-513 (AZ-150 GSM, AL Zn alloy metalic coating, 550 MPA yield stress as per AS-1397), colour /exterior coat of silicon modified polyster/ BHP X RW paint system 20 micron top coat applied over 5 micron primer and a 5 micron polyster back coat applied over 5 micron primer,as in roof covering/ cladding to wall fixed with and including Galvanised self drilling self-tapping fastener (12-14 x 55 with EPDM seals), complete all as specified and directed.
M&L for 75 mm thick PCC, type C-1, (1:3:6) using 20 mm graded stone aggregate as in plinth protection and hard standing; finishing the surface even and smooth without using extra cement including provision of 10 mm wide joints (at an interval of 3 metres & turnings) duly filled with fine sand and bitumen in the ratio of 3:1, complete all as specified and directed.
M&L for preparation of new steel surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of red-oxide primer, complete all as specified and directed.
M&L for preparation of new steel surfaces of any description, over 10 cm width or girth, and applying two coats of synthetic enamel paint (1st grade quality), complete all as specified and directed.
M&L for preparing new plastered surfaces of wall etc & applying three coats of white wash, complete all as specified & directed.
M&L for preparing newly plastered surfaces of walls etc and applying two coats of cement base paint, complete all as specified and directed.
Dismantling of existing Over Head Aluminium conductor steel reinforced, stretched over the poles etc, complete all as specifed and directed.
M&L for over head aluminium conductor, steel reinforced of size as per existing for making connections to CTs, PTs, GODs and Droup out fuses, complete all as specifed and directed.
Dismantling of existing cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, fixed over the poles etc, complete all as specified and directed.
Supplying, laying, jointing and testing XLPE insulated, armoured, heavy duty, electric cable with stranded aluminium conductor 1100 volts grade, cross sectional area 10 Sqmm x 4 core in trenches /along poles/on wall etc, complete all as specified and as directed Notes for item No 42. : (i) Excavation and earth work, sand cushioning, protection covers shall be measured and paid for separately. (ii) Unless otherwise directed by the GE, the cable shall be procured by the contractor in single length (as manufactured) to meet the actual length of cable as required at site. However, for payment purpose, the length actually ordered & laid shall be measured and paid for.
Re-routing and re-laying of LT UG cable in trenches with necessary connections and disconnections for re-distribution of load of 11/ 0.433 KVA distribution transformer including taking out of existing cable, necessary extension of cable (if required), complete in all respects, as specified and directed. Notes for item No 43: (i) Excavation and earth work, sand cushioning, protection covers shall be measured and paid for separately. (ii) Additional cable in case required and provided shall also be measured and paid separately.
M& L for Sand cushioning in trenches for cushioning of underground cable including spreading, levelling, well ramming in layers not exceeding 25cm in thickness, complete all as specified and directed.
Material and labour for well burnt Sub-class 'B' old size bricks, best quality locally available laid flat, dry in trenches for cable protection, complete all as specified and as directed.
Supply and fixing GI tubing, light grade, 40mm bore for protection of cable under road crossing, across drain, along electric pole or floor /wall etc, complete all as specified and directed. Note for Item No. 46 : Excavation & Earthwork/Boring/ Drilling shall be measured & paid for separately. However the cost for provision of clamps made from mild steel flat of required size, bolts, nuts, washers etc (including painting of mild steel surfaces with 2 coats of aluminium paint over 1 coat of red oxide primer) for fixing of G.I. pipes with poles etc shall be deemed to be included in the quoted rate of above item.
All as per Item No 46 above but 80mm bore tubing, complete all as specified and directed.
Boring (horizontally) using ultrasound technique and necessary machine for passing 80/40mm bore pipe for protection of the cable at approx 1 metre depth in soil below existing road, pavement, hard standing etc without damaging the existing surfaces, getting out & disposal of soil to a distance not exceeding 50 metre from the site of work, complete all as specified and directed. Note : Cost for provision of pipes & cable not included in the scope of above item.
S & F in repairs Steel Tubular Poles complete with and including cast iron base plate, finial taper plug, bolts , nuts & screws, type 410 SP-64(12 Metre long), also including painting to the external exposed surfaces with 2 coats of aluminium paint over 1 coat of red oxide primer and with 2 coats of black bituminous paint over 1 coat of red oxide primer to the external exposed surfaces of steel poles embedded in the ground / concrete after preparation of the surfaces, numbering to the poles, complete in all respect as specified and as directed. Note:- Excavation & Earth Work, concrete for foundation and coping shall only be measured and paid for separately.
S&F in repair for LED flood light fittings/Luminaries 500W with the following specifications: - (a) Housing: - Epoxy powder coated PDC aluminum housing. (b) Lumens per watt : - Not less than 120 Lm/watt (minimum). (c) Not less than 6.5 KV driver internal surge protection (d) Operating voltage range: - 140-290V, AC, 50 Hz (e) CRI>70 (f) CCT - not less than 5700K (g) IP: - 66 and IK 08 (h) THD: - <10% (j) Toughened glass cover (k) Mounting: - Clamp mounting Make: PHILIPS Cat No BVP485 LED 540 CW AWB PSU SPD GR or CROMPTON Cat No LFLPI-500-CDL/60 or HAVELL's Cat No JETAVALOURFL500W4M LED 757 PINTN BLTG or equivalant of Make BAJAJ as approved by the GE.
All as per item No 50 but 400W, Make: PHILIPS Cat No BVP485 LED 427 CW AWB PSU SPD GR or CROMPTON Cat No LFLPI-400-CDL/60 or HAVELL's Cat No JETAVALOURFL400W3M LED 757 PINTN BLTG or equivalant of Make BAJAJ as approved by the GE.
M&L for earth continuity conductor or main earthing lead of size 25X3 mm galvanized iron strip fixed to wall on batten or recess or chases or burried in ground or drawn in existing conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc including dismantling of existing one, complete all as specified and directed. Note :- Excavation and earth work shall be measured and paid for separately.
Supply and fixing in repairs street light control panel, 3 phase, 6 KW capacity, complete all as specified and dircected. Make: Havells, Cat No-IHXTS03060 or equivalent of Make L&T or ABB as approved by GE.
M & L for plain cement concrete type B-2 (1:2:4), using 40mm graded stone aggrgate for PCC blocks etc including use and watse of necessary formwork, complete all as specified and directed.
Dismantling, collecting and depositing of HT/LT switch gears, transformers, VCBs including transporting from different Sub Station to MES Store Yard as directed with necessary arrangement of heavy load lifting hydra and transportation by vehicle and cleaning of Sub Station, all as directed by Engr-in- charge. Notes:- (a) Dismantling of unserviceable items from foundation etc and carrying all shall also be deemed to be included in the quoted rate. (b) For heavy unserviceable items, dismantling in stages/ parts/ piecemeal and lifting, carrying all shall also be deemed to be included in quoted rate.
M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead of GI strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, complete all as shown in Electrical Plate No. 3 of SSR Part-1 and connected to earthing test point and including dismantling of old one, complete all as specified and directed. Note: The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C-1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 15 mm bore GI light grade earth lead rotection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
M&L for carrying out repairs of existing old LT panels/ bus bar chamber/ feeder piller box of size upto 1000 mm (Height ) X 1000 mm (Breadth) X 500 mm (Depth) by excavation of all loops, removing damaged UG cable portion connected to the panel, making connection with provision of new thimbles/ lugs/ cable glands, replacing existing one with provision of new neoprene rubber gasket to make it completely dust and vermin proof, provision of new locking arragement, rewiring with appropriate size of new copper conductor wire, repairing of rusted parts of frame & supporting channel with necessary welding works including preparation and applying one coat of synthetic enamel paint on the entire internal steel surfaces and one coat of aluminium spray paint on out side entire steel surfaces, complete all as specified and directed. Note:The unit rate quoted shall also be deemed to be include the cost of earth work, PCC foundation (1:3:6) type C-2, new thimbles/ lugs/ cable glands, neoprene rubber gaskets, bus bars, wirings, welding works, painting, sand fillings in loops etc. as required. Payment for replacement of damaged cable shall be measured and paid separately.
All as per Item No 57 above but M&L for carrying out repairs of LT panels of size more than 1000 mm (Height ) X 1000 mm (Breadth) X 500 mm (Depth) (Transformer main panels and other LT panels).
Supply and fixing in repairs LED type Phase indicating lamps (Red, Orange, Blue) in the existing LT Panel complete all as specified and as directed.
Supply and fixing in repairs CTs (Accuracy class 1.0, CT Ratio-200/5, Burden-15VA, 3 Phase) in the in existing LT Panel, complete all as specified and as directed.
Supply, installation, testing and commissioning of MCCB, 400A, with spreader terminals, 36 KA, 4 pole, Ics=100% Icu with thermal megnetic protection unit of suitable size, in the existing LT Panel including taking down of old unsv one, complete all as specified and as directed.
Supply, installation, testing and commissioning of MCCB 250A, with spreader terminals, 36 KA, 4 pole, Ics=100% Icu with thermal megnetic protection unit of suitable size, in the existing LT Panel including taking down old unsv one, complete all as specified and as directed.
Supply, installation, testing and commissioning of MCCB, 200A, with spreader terminals, 36 KA, 4 pole, Ics=100% Icu with thermal megnetic protection unit of suitable size, in the existing LT Panel including taking down old unsv one, complete all as specified and as directed.
Supply, installation, testing and commissioning of MCCB, 100A, with spreader terminals, 25 KA, 4 pole, Ics=100% Icu with thermal megnetic protection unit of suitable size,in the existing LT Panel, including taking down old unsv one, complete all as specified and as directed.
Supply, installation, testing and commissioning of MCCB, 63A, with spreader terminals, 25 KA, 4 pole, Ics=100% Icu with thermal megnetic protection unit of suitable size, in the existing LT Panel, including taking down old unsv one, complete all as specified and as directed.
M & L for cross arms, bracings, supports, clamps, back plates, stairs (a/w the poles) fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of preparation of exposed surfaces, application of one coat of red oxide primer and thereafter 2 coats of alluminiuam paint, complete all as specified and directed.
S&F in repairs, Copper Earth Termination Rod, 12mm dia x 1 metre long, single spike, complete, all as specified and directed.
M & L for cement concrete (1:3:6) type C-2 (using 40mm graded stone aggrgate) for pole foundation including provision of necessary form work, complete all as specified and directed.
M & L for cement concrete (1:2:4) type B-1 (Using 20mm graded stone aggregates) for coping of pole etc including provison of necessary form work, complete all as specified and directed.
S&F in repair of LED street light Fittings/Luminaries, 45W, white, complete with & including internal driver and LED light, surge protection, with aluminum housing and lumens per watt not less than 110 Lm/watt complete all as specified and directed, Make: PHILIPS Cat No BRP263 LED 52 CW M2 FGPSU GR ELP or CROMPTON Cat No LSTP-45-CDL or HAVELL's Cat No ENDURAPEARLNEO SL 45W LED 757 PASYTOPC or equivalant of Make BAJAJ as approved by the GE.
S&F in repair of LED street light 60W Fittings/Luminaries, white, complete with & including internal driver and LED light, surge protection, with aluminum housing and lumens per watt not less than 110 Lm/watt complete all as specified and directed, Make: PHILIPS Cat No BRP062 LED 65 CW SLA S1 PSU or CROMPTON Cat No LSTP-60-CDL or HAVELL's Cat No ENDURAPEARLNEO SL 60W LED 757 PASYTOPC or equivalant of Make BAJAJ as approved by the GE.
S&F in repair of LED flood light Fittings/Lumanaries, 100W, white, complete with & including internal driver and LED light, surge protection, with aluminum housing and lumens per watt not less than 110 Lm/watt, IP 66, complete all as specified and directed, Make: PHILIPS Cat No BPV192 LED 110 CW HO NB FG GR PSU or HAVELL's Cat No JETAIRSFL 100W LED 757 SYMLTG or equivalant of Make: CROMTON or BAJAJ as approved by the GE.
S&F in repair of LED Post Top light Fittings/Lumanaries, 25W, complete with & including internal driver and LED light, surge protection, with aluminum housing and lumens per watt not less than 110 Lm/watt complete all as specified and directed, Make: HAVELL's Cat No RUBYPT25W LED 757 PSYMTOPC or equivalant of Make CROMPTON/PHILIPS/BAJAJ as approved by the GE.
S&F in repair of LED bollard light Fittings/Luminaries, 10W, complete with& including internal driver, LED light, surge protection, aluminum housing and lumens per watt not less than 110 Lm/watt, also inclusive of foundation, base, all as specified and directed, Make: HAVELL's Cat No MOUNTBLOW LED 830PSYMTOP MMAM (1M) or equivalant of Make CROMPTON/PHILIPS/BAJAJ as approved by the GE.
All as per Item No 76 above but Fittings/Lumanaries,8W of Make: HAVELL's Cat No CONENXGBLS 8W LED 830 PSYMTOPCM (1M) or of Make CROMPTON Cat No LBLSN10CDL or eqvivalent of Make PHILIPS/BAJAJ as approved by the GE.
S&F in repair, factory made (CPRI approved) weather proof, dust & vermin proof street light junction box of size 250(L) x 200 (B) x 150 (D) mm (minimum dimensions) made up of 3.15 mm thick CRCA sheet, powder coated after preparation of surfaces, comprising of 04 Nos copper bus-bar of size 20 x 4 mm mounted on suitable sized spacer insulators with provision of 01 No MCB, SP, 6 Amps, 10 KA breaking capacity, "C" curve & two openings at the bottom & one opening at the top with & including cable glands & fixing with the provision of suitable sized MS clamps to poles, also including testing, complete all as specified and as directed.
Taking down old unserviceable existing XLPE/PVC insulated underground LT cables with aluminium conductor, complete all as specified and as directed. Note:- Excavation and earth work shall be measured and paid for separately.
M/S MECHANICAL ENGINEERING and ELECTRICAL CONTRACTORS
M/S Sohanlal Agarwala
M/S B D ENTERPRISE
M/s BHAGWATI CONSTRUCTION
TOTCO
New Era Engineers
M/s Barua and Co.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .