Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹50.1 L+₹49,656.10 (1.00%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 bidder | |
| 3 | L3₹51.9 L+₹2.3 L (4.63%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 bidder |
Tender Value
₹46.6 L
EMD Value
₹93,200
Closing Date
2 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS PIN-913862 C/o 56 APO
SPECIAL REPAIR TO BLDG NO T-16 AND SEWAGE SYSTEM INCLUDING CERTAIN MINOR WORK AND REVENUE WORK IN AOR OF AGE B/R DETT-B, DETT-III AND AGE E/M UNDER GE 862 EWS
2023_MES_621895_1
GER-49/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS
As per tender documents
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹93,200
Yes
18 Dec 2023
6 Oct 2023
4 Nov 2023
6 Oct 2023
2 Nov 2023
19 Oct 2023
Amount
Sch 'A' Part-I (B/R works) Surface dressing not exceeding 15cm deep in any type of soil complete all as specified and directed.
Surface excavation in any type of soil, n.exc 1.5m 30cm deep and averaging 15cm deep and getting out, complete all as specified and directed.
Excavation over area , n.exc 1.5m deep and getting out in any type of soil, complete all as specified and directed.
Excavating in trenches, n.exc 1.5m wide and n.exc 1.5m in depth in any type of soil for foundation, etc, or for shafts, wells, drain/water pipes laying of cables etc, n.exc 10 Sqm on plan and getting out, complete all as specified and directed.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick ,complete all as specified and as directed.
Removing excavated material ,not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed.
Removing excavated material exceeding 5 Km but n.exc 10 Km and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed.
M&L for plain cement concrete 1:4:8, type D-2 using 40mm graded stone aggregates as in sub base, foundation, filling and mass concrete complete all as specified and directed.
M&L for 75mm thick plain cement concrete 1:4:8, type D-2 using 40mm graded stone aggregates as in sub base of floors and mass concrete, complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4, complete all as specified and directed.
M&L for rendering 10 mm thick in cement mortar 1:6 on fair/unfair faces of brick work or concrete surface, finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on other than fair faces of brick work or concrete surface (external surface), finished the surface even and smooth without using extra cement mixing with integral water proofing compound (as per manufacturer's instructions), complete all as specified and directed. (Note: Rate of WPC will be included in the quoted rate)
M&L for rendering 5 mm thick on concrete surface in cement mortar 1:3 on ceiling, finished even and smooth with sagol cement ,complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of exterior emulsion weather proof paint of apex ultima over and including a coat of primer, complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying three coats of white wash, complete all as specified and directed.
M&L for hardcore of gauge n.exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and remmed to a true surface, complete all as specified and directed.
M&L for 75mm thick plain cement concrete, type C-2, 1:3:6 (using 40mm graded crushed stone aggregate) as in plinth protection, laid in slope 1:12 from outer edge of the wall, finished even and fair, laid in alternate bays including providing 6mm wide joints throughtout thickness of plinth protection in concrete bays and in between walling and plinth protection, joints filled mastic filling comprising of one part of heated bituminous 85/25 and 3 parts of sand (all by weight), complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (premium quality) Square/rectangular, area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
M&L for glazed ceramic coloured tiles of size 350x250x7mm or 450x350x7mmthick, (premium quality) on vertical surface of wall such as dado, skirting, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 10mm thick rendering in cement mortar 1:4, complete all as specified and as directed.
M&L for solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, complete all as specified and directed.
M&L for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail : Panelling of plain colour PVC sheet to be fitted in the M. S . frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing mentioned in SSR Part-II 2020, complete all as specified and directed.
S&F for 100mm long butt hinges medium weight, stainless steel, complete all as specified and directed.
S&F for aluminium anodized barrel tower bolts 150 mm long of extruded section (ISI marked) ,complete all as specified and directed.
S&F for extruded aluminium alloy handles size 150 mm fabricated type anodised (ISI marked), complete all as specified and directed.
S&F for vitreous China water closet (squatt pan) Orrisa pattern 680x470 mm size pan, white/colour, with front or back inlet with integral 'foot rests (PVC), (excluding flushing cistern and flush pipe) including connections to flushing cistern with flush pipe including provision of lime concrete, complete all as specified and directed.
S&F 10 ltrs capacity (PVC), valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, complete all as specified and directed.
S&F for vitreous China wash hand basin, white, flat back of size 550x 400mm excluding taps, waste chain and plug and porcelan stopper but including brackets and cutting for fixing brackets ,complete all as specified and directed.
S&F for vitreous China urinal, half stall type, premium quality white, including flush pipe and waste pipe with grating and union for discharge pipe (excluding flushing cistern) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60cm long brass screws, pointing around urinal back in cement, complete all as specified and directed.
S&F for rotational moulded polythylene water storage tank (ISI marked) with float valve, plastic lid cover, multy-layered, cylindrical vertical with closed top, hoisted and fixed in position of capacity 500 ltrs tank and making connections inlcuding suitable GI wash out, over flow, nipple and including 20mm bore ball brass valve with union screwed for iron pipe and fixed complete all as specifed and directed.
S&F for 15 mm bore galvanised iron GI tubing medium grade with all fittings such as bends, socket, tee, elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors etc, complete all as specified and directed.
S&F for 20 mm bore galvanised iron GI tubing medium grade with all fittings such as bends, socket, tee, elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors etc, complete all as specified and directed.
S&F for 25 mm bore galvanised iron GI tubing medium grade with all fittings such as bends, socket, tee, elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors etc, complete all as specified and directed.
M&L for 15mm bore angle valve, fancy type, chromium plated, cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed down high pressure, screwed for iron pipe or for unions and fixed, complete all as specified and directed.
S&F for 15mm bore bib tap, fancy type, cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete as in repair all as specified and directed.
S&F for PVC connection 15 mm x 600 mm including PTMT nuts at both ends screwed for iron pipe of 15 mm bore, complete all as specified and directed.
M&L for 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in floor/ trenches, or fixed to wall, complete all as specified and directed.
M&L for 750mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in floor/ trenches, or fixed to wall, complete all as specified and directed.
M&L for 110mm bore PVC (SWR) Tee or branch piece single ordinary or inverted or with parallel branches but fitted with oval access door complete all as specified and directed.
M&L for 75mm bore PVC (SWR) junction, (single T) equal or unequal complete all as specified and directed.
M&L for 110mm bore PVC (SWR) vent cowl complete all as specified and directed.
M&L for 110mm bore PVC (SWR) bends complete all as specified and directed.
S&F 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement and connecting to waste pipe, complete all as specifed and directed.
M&L for 110/125mm bore PVC (SWR) gully trap, set and jointed with solvent cement complete all as specified and directed.
M&L for stack clamps made out 50mm x 5mm FL and 16mm dia round iron stay including bolts and nuts and securing ends of stay to wall and roof for 150mm bore of pipe, complete all as specifed and directed.
M&L for steel ventilators with top hung shutter including hinges, steel peg stay complete all as specified and directed.
M&L for mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks or portion framed and hung as gates, including pintel hinges, stops, hand made sliding bolt etc and similar work conforming to Fe 410-0 or Fe310-0 work including welded fabricks frames, gate and framed truss, complete all as specified and directed.
M&L formwork to sides of concrete foundation, footing, bases of colums, raft & raft beams, sides and soffits (if any) of foundation and plinth beam and similar work, in rough finished flat surface of concrete, complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
M&L for mild steel TMT bars 6 to 10mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
M&L for mild steel TMT bars 5mm dia and over upto including 10mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends as in stirrups, spacers and binders including binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
M&L for reinforced cement concrete M-25 (Design mix) (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns and the like, complete all as specified and directed
M&L formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surface of concrete, complete all as specified and directed.
M&L for reinforced cement concrete M-25 (Design mix) (using 20mm graded crushed stone aggregate) as in columns, pillars, piers, post, struts and the like, complete all as specified and directed
M&L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilivers, shelves, including sup-ports, overhangs etc also splays between floors and beam etc, complete all as specified and directed.
M&L for reinforced cement concrete M-25 ( Design mix) (using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintel over 1.5 mtr span, complete all as specified and directed
M&L formwork to soffits of suspended slabs such as roof slabs, landings and similar work; n exc 200mm thick (Horizontal and sloping) for rough finished surface of concrete, complete all as specified and directed.
M&L for reinforced cement concrete M-25 ( Design mix) (using 20mm graded crushed stone aggregate) as Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed
M&L for preparation of new steel surface exc 10 cm width or girth and applying two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and as directed by Engr-in-Chagre.
M&L for construction of LLDPE septic tank (conventional) of capacity 10 users designed to carry sewage and sludge water, excavation in any type of soil, brick work in cement mortar 1:4, PCC 1:2:4 type B-2 in foundation, RCC slab cover including RCC precast manhole cover vent shaft, connection etc including returning , filling of soil at sides of tank, well ramming in layers and removing excavated surplus soil to a distance not exc 50m,and shown on drawing No CE/TD 1202/2008 SH 1/2 & 2/2 and as directed at site by Engr-in-Charge.
M&L for construction of septic tank of capacity 100 users with RCC cover slab in M-25 (Design mix), brick work in CM 1:4 (with top of slab at ground level) including excavation in any type of soil, PCC 1:2:4 in type B-2 in foundation, manhole cover vent shaft, connection etc including returning , filling of soil well ramming in layers and removing excavated surplus soil to a distance not exc 50m, RCC cover slab with angle iron frame completeall as shown on drawing No CE/TD 1202/2008 SH 1/2 & 2/2 and as directed at site by Engr-in-Charge.
M&L for construction of soakage well 3.6 m dia and 3.00 m deep including excavation and earth work in any type of soil, PCC 1:3:6, type C-2 in foundation, walls of honey combed masonry with top ring of M-25 concrete including intercerpting chamber and screen chamber made of brick masonry in cement mortar 1:4, RCC cover slab in M-25, interconnecting pipes of RCC, complete filled with brick bats complete all as specified and shown on drawing No CE/TD 1202/2008 SH 1/2 & 2/2 and as directed at site by Engr-in-Charge.
M&L for plain cement concrete 1:3:6, type-C-2 (using 40mm grade crushed stone aggregated) as in bed to drains pipe including packing under and haunching agsinst the sides of pipe after they are laid and tested for salt glazed stonewere pipe 150mm dia, complete all as specified and directed.
M&L for providing precast cement concrete 1:2:4, type B-1 using 20mm graded stone aggregate as in manhole cover, chullah hoods, chajjas, water troughs, mangers, shelves and similar items with plain faces in cement concrete and setting in cement morter 1:4 including necessary formwork complete all as specified and directed
M&L for chequered cement concrete tiles of size 20 cm x 20cm x 25 mm thick set, jointed in neat cement slurry in floor and pointed in white or coloured cement to match the shade of tiles laid over and including 20 mm thick screed bed in cement mortar 1:4, complete all as specified and as directed.
M&L for plain cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges including necessary form work, complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nanital or similar pattern roof covering complete all as specified and directed.
S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in roof covering/cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions, complete all as specified and directed.
S&F for Pre-painted galvalume aluminium zinc coating GI based plain sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in ridges, hips, valley gutters fixed with self tapping screws including side and end lap as per manufacturer’s instructions, complete all as specified and directed.
S&F for rooled mild steel in joist, channel, agnle, or tee sections, fixed independently, without connecting plates, etc., (Cut to ordinary lengths i.e. within 20mm of the length as indicate) in Fe-410W Gde E-250 quality 'B', complete all as specified and directed.
M&L for Mild steel structural steel work including tubular member as in main and cross beam/columns, hip and jack, rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates (Fe-290 Gde E-165 Quality A) complete all as specified and directed. (Note :- All structural steel work shall be painted with one shop coat of zinc chromate red oxide primer including preparation of surfaces before fabrication and rate shall be included in this item).
Dismantling of timber scantling 40 Sqcm and over in section, in any position as in unframed or framed work complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and paving n exc 15 cm thickness below or above the ground level, complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles, complete all as specified and directed.
M&L for stone walling of random rubble masonry, uncoursed, well bonded, bedded and soilidly hearted, built in cement mortar 1:6, complete all as specified and directed.
M&L for 18-20mm thick Machine cut kota stone slab (mirror polished) as in flooring, jointed with grey cement slurry mixed with pigment to match the shade of the slab including machine cutting to make it square or rectangular, rubbing and cutting and polishing to achieve mirror finish, laid over and including screed bed or bedding layer of 15 mm thick in cement mortar 1:4 of any size complete all as specified and directed.
M&L for 18-20mm thick Machine cut kota stone slab (mirror polished) as in riser, steps, skirting, dado and pillar and jointed with grey cement slurry mixed with pigment to match the shade of the slab including machine cutting to make it square or rectangular, rubbing and cutting and polishing to achieve mirror finish, laid over and including screed bed or bedding layer of 15 mm thick in cement mortar 1:4 of any size complete all as specified and directed.
Taking down cement plaster, any description on any walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on stone masonry surface or other than fair faces of brick work, finished surface even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:6 on stone masonry surface or fair faces of brick work, finished surface even and smooth without using extra cement, complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of chalk whitening including 3mm thick wall care putty, complete all as specified and directed.
Complete removal of existing treatment of old plastered surface of walls and preparing surface including washing rubbing down and stopping of walls and applying one coat of distemper oil emulsion white or tinted to match with existing surface, complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of exterior emulsion weather proof paint of apex ultima over and including a coat of primer, complete all as specified and directed.
Complete removal of existing treatment of old plastered surface of walls/roof surface including cornice and chajjas etc and applying two coats of exterior emulsion weather prrof paint of apex ultima over and including one coat of primer, complete all as specified and directed by Engr-in-Charge.
S&F in repair for stainless steel curtain rod of 20mm dia, complete all as specified and directed.
S&F bracket and finials of stainless steel of 'T' and 'L' type (colour and design approved by GE) for curtain rod stainless steel 20mm dia including fixing to walls with MS full screws (including fixing of wooden pieces of required size of walls) complete as in repair all as specified and directed .
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each, complete all as specified and directed.
S&F for factory made 30 mm thick 2nd class hard wood glazed and skelton shutters open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and directed.
S& F for galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks, or galvinsed wire staples , complete all as specified and directed.
S&F for factory made 2nd class hard wood 35 mm thick plain framed panelled shutters (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F for pressed steel door frame of size 125x60 mm with one or more rebates including necessary fixing lugs, hinges, lock and strike plate etc including back filling to chowkhats in PCC 1:3:6 type C-1 using 20mm graded stone agregate complete all as specified and directed.
M&L for 300mm long (lenth of bolt) aluminium alloy, anodised, sliding door bolt with hasp, stapl (bolt type) and fixing clips of sheets, cast or extruded section and fixing bolts and sliding bolt of extruced sections or cast aluminium alloy anodised (ISI marked) complete all as specified and directed.
M&L in repair 140mm long floor door stopper of aluminium alloy body and tougue with hard drawn steel spring complete all as specified and directed.
S&F for 4mm thick designer ceiling board in ceiling fixed with screw as per manufacturers instructions, laid over and including hot dipped galvanised iron in post grid with 24mm wide T section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33 mm thick galvanised steel sheet of size 24 x 32 x 300 mm spaced at 1200 mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire 4 mm dia to be fixed by approved rawl plug or hanged with existing truss members. The last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall flush fittings of 1200 mm long screws Tee with (double stiching) to interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm modules cross tee longer than 600 mm modules to be formed by fittings 600 mm long cross tee, tee perimeter wall angle shall be of 0.45 mm thick galvanised steel of size 19 x 19 mm and 300 mm long of white colour all as per insturctions including dismantling of existing ceiling board etc, complete all as specified and directed.
M&L for preparation of new wooden surface exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of old steel surface exc 10 cm width or girth and applying one coats of synthetic enamel paint, complete all as specified and as directed by Engr-in-Chagre.
M&L for treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors, complete all as specified and directed.
M&L formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide,for rough finished surfaces of concrete, complete all as specified and directed.
Desludging of manholes, septic tank & filter beds of any description, any capacity and any position by pumping out and removing to a distance exc 250m by mechanical means (trolly mounted) and burring in pits complete all as specified and directed
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition and breaking up drain pipes 150mm (salt glazed stoneware, AC or reinforced concrete) se in cement mortar, complete all as specified and directed.
Supply & laying reinforced concrete pipes 200mm dia bore , class NP-2 laid and jointed with coller, complete all as specified and directed.
M&L for plain cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregate) as in apex stone, coping, benching, hold fasts, water troughs, bed block, surface channel and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block of any shape and size approved by Engineer-in-Charge , ISI marked (IS:15658-2006) 80mm thick, M-35 grade (Heavy Traffic), in paths and hardstanding, with grey cement, and pigment laid tightly and joints filled with dry sand, colour and pattern as approved by GE, complete all as specified and directed.
M&L for cutting, threading and inserting tee of size 100x100x40mm for taking new branch connection from existing pipeline of size 100mm bore complete all as specified and directed
M&L for 25mm bore gun metal, gate / globe valve with iron wheel head screwed on both sides for iron pipes and fixed, complete all as specified and directed.
Rolling and consolidating formation surface with 8 to 10 tonne power roller including filling soft spots, depression etc, which occure during rolling for required level gradient or camberetc including watering as necessary during rolling complete all as specified and directed.
M&L for 150mm thick soling (or sub base) with broken boulders or quraiie stone stone of size 50to 100mm, interstices filled, surface formed and rolled and consolidated to required gradient and camber with 8 to 10 tonne power roller complete all as specified and directed.
M&L for Cement concrete work in pavement PQC in hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less including necessary form work etc and provision of kerb stone upto scour depth incuding all necessary formwork at both sides of roads as required at site and directed by Engr-in-Charge. Note : (i) All concreting shall be done by using computerised automatic concreting batching plant of minimum capacity 06 to 08 cum/hour, which shall be installed by the contractor, BATCHING & MIXING at site, calibrated and tested. The batching plant shall conforming to IS-4925 have the faclilites of data printouts, presenting the quantity to be weighted automatic cut-off when the same is achieved. (ii) General samples from fresh concrete shall be taken as per IS-1199 and cubes shall be made cured and testd at 28 days in accordance with IS-516. (iii) In order to get relatively quicker ides of the quality of concrete optional tested on beams for modulus of rupture at 72 + 2h or at 7 days, or compressive strength test at 7 days may be carried out in additional to 28 days compressive strength test. For this purpose the values should be arrived at based on actual testing. In all cases, the 28 days compressive strength specified in table 2 shall be alone the criteria for accepted or rejection of the concrete. (iv) In case of non-availability of batched concrete, (Ready mix concrete/ RMC) complete shall be used on site.
Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’, thicknesss of concrete slab 250 mm, including providing 20mm dia mild steel dowel bars 50cm in long (25cm in each slab) it ferrules spaced @300mm c/c including boring formwork and performed filler for dowels, complete all as specified and directed.
Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound, grade 'A' complete all as specified and directed.
M&L for Plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in surface channels and drains incl necessary formwork complete all as specified and directed.
M&L formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 20cm wide,for rough finished surfaces of concrete, complete all as specified and directed. (Note: Where RCC/PCC band in wall, spanning and opening, the formwork, soffit only shall be paid for )
M&L for brick work with sub class 'B' old size bricks, straight or curved on plan and any radius in half brick, thick wall built in cement mortar 1:4, complete all as specified and directed
M&L for treating the bottom and sides of excavation at the rate of 5 litre of emulsion per aquare meter of surface area complete all as specified and directed.
M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square meter of vertical surface (Area of sub structure in contact with back fill to be measured), complete all as specified and directed.
M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square meter of surface area, complete all as specified and directed.
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square meter of surface area, complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopper ends etc complete all as specified.
Sch 'A' Part-II (E/M works) Taking down carefully copper/ aluminum point wiring (light, fan, socket or power) complete, including all fittings such as switches, ceiling roses, pendants, regulators sockets etc.) removing material from the site and making good the disturbed surfaces of walls, floor or ceiling etc. to match with existing specifications, complete all as specified and directed.
M&L for point wiring for one light point/fan point controlled by one-one way switch with 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor unsheathed in and including PVC casing caping medium grade of 25mm width complete with all acessories including PVC sunk box ISI marked for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly including making good the diturbed surfaces compete all as specified and directed. (Note:- Three run of copper conductor of required size and one run of casing capping measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth)
Description all as per Serial item No 121 above but for one 3 pin 5 Amp socket outlet on independent board controlled by one 6 amp switch, complete all as specified and directed.
Description all as per Serial item No 121 above but for one 3 pin 5 Amp socket outlet on same board controlled by one 6 amp switch, complete all as specified and directed.
Description all as per Serial item No 121 above but for one 5 pin 15 Amp socket outlet independent with 2.5 sqmm PVC insulated FRLS multistraind copper cable with 2.5 sqmm single core multistraind FRLS copper cable as earthling lead complete all as specified and directed.
M&L for switch piano, flush type single pole, one way 5 Amp, 240 volts complete all as specified and directed.
M&L for switch socket combination 2 in 1, flush type single pole, one way 3 Pin 5 Amp, 240 volts, complete all as specified and directed.
M&L for socket outlet 2 in 1, flush type, 6 Pin 5 & 15 Amp, 240 volts, complete all as specified and directed.
S&F for ceiling rose 3 phase / PVC / polycarbonate isolated body surface bakelite 2 to 3 terminal, 63.5 x 17mm complete all as specified and directed.
M&L for ceiling fan regulator elctronic, flush type, hum free suitable to control speed of fan from 0 to 100% rotary type five step 240 volts AC complete all as specified and directed.
S&F for lamp holder insulated body PVC/ Polycarbonate type with back plate suitable for batten/angular/pendent fittings including LED lamp 7 / 9 watt complete all as specified and directed.
M&L for LED Tube light fitting, complete with 1x 20 watts, 220V, AC decorative box type with driver, holder in and including LED tube light connection complete prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core and connector block etc and necessary fixing arrangement at any height complete all as specified and directed.
S&F for environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head 10 watt 6000 K inbuilt LED luminaire comprising of high brightness LEDs, IP54 protection including connecting electrically using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete all as specified and directed.
S&F in repair for LED recess mounting high lumen panel light 36 watts, 2 x 2 feet with white power coated CRCA housing with high power LEDs, aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230v complete with all accessories such as electronic driver, LED strip, connector block etc and necessary fixing arrangement at any height complete all as specified and directed
Taking down ceiling fan of any sweep of any make from its existing position, after disconnectioning electric connection for carrying out repairs including servicing, overhauling, greasing etc after cleaning the body internally and externally with cleaning agent including renewal of minor spare parts such as split pin, cater pins, coupling bolt, capacitor holder, terminal adopto, screws nuts and washers etc and replacement of spare parts / accessories such as ball bearings gun metal bushes capacitor canopy top and bottom, shakle clip assembly, overhauling of fan motor, painting and including hanging fixing back in existing location and making cable connection and testing for its satisfactory performance complete inlcuding wirting of fan number with white paint, complete all as specified and directed.
S&F for MCB distribution board SPN 2 way, single door 240 volts duly painted with epoxy based powder coated painting suitable for mounting MCB as incomer and outgoings complete with busbar, neutral bar, earth bar connecting cable links with top and bottom removable gand plate with IP 42 protection, complete as in repairs all as specified and directed. (Note:- MCBs will be measured separately.)
S&F for MCB distribution board SPN 12 way, double door 240 volts duly painted with epoxy based powder coated painting suitable for mounting MCB TP/FP as incomer and outgoings complete with busbar, neutral bar, earth bar connecting cable links with top and bottom removable gand plate with IP 42 protection, complete as in repairs all as specified and directed. (Note:- MCBs will be measured separately.)
M&L for MCB single pole, 240 volts any rating from 6 to 32 amps, 'C' series/curve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
M&L for MCB single pole & neutral 240 volts any rating from 40 to 63 amps, 'C' series/curve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
M&L for MCB DP, 240 volts any rating from 10 amps, 'C' series/curve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010 including testing on completion, including taking down old earthing complete all as specified. (Note:-Earth strip and protection pipe upto board is included in the rate quoted)
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010 including testing on completion, complete all as specified. (Note:-Earth strip and protection pipe upto board is included in the rate quoted)
Supply, laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 10 Sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands, complete all as specified and directed.
Supply, laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 Sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands, including taking down old cable complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
S&F for speading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR part-I and as directed. Note: punned thickness of sand shall be measured.
Supplying and laying unreinforced precast factory made concrete cable cover, class LV, type -I, flat or size 250mm x 150mm x 40mm, complete all as specified and directed
M&L in replacement for 50mm bore galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls for protection, complete all as specified and directed.
S&F for exhaust fan of 250mm sweep, heavy duty, 1200 RPM electrical operated 230 Volts AC single phase, made with sturdy engineering plastic with all accessories and louver etc, complete all as specified and directed.
M&L for sub main wiring complete with 4 run of 6 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC conduit of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 6 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable sub main wiring items complete all as specified and directed. (Note : - 04 run of 6 sqmm single core copper conductor cable and 01 run of 6 sqmm single core copper conductor and 01 run of PVC conduit shall be measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth).
M&L for sub main wiring complete with 4 run of 10 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC conduit of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 10 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable sub main wiring items complete all as specified and directed. (Note : - 04 run of 10 sqmm single core copper conductor cable and 01 run of 10 sqmm single core copper conductor and 01 run of PVC conduit shall be measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth).
M&L for sub main wiring complete with 2 run of 4 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC conduit of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 4 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable sub main wiring items complete all as specified and directed. (Note : - 02 run of 4 sqmm single core copper conductor cable and 01 run of 4 sqmm single core copper conductor and 01 run of PVC conduit shall be measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth).
S&F for sheet metal enclosure with triple pole, neutral and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 32 amps complete all as specified and directed.
S&F for sheet metal enclosure with triple pole, neutral and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 63 amps complete all as specified and directed.
S&F for sheet metal enclosure with single pole, neutral and earth enclosure with a two pin and earth plug with socket complete with one single pole MCB 20 amps complete all as specified and directed.
Supply and install Hi wall split units indoor/ outdoor complete with cordless remote control unit and with cooling and heating function of cap 1.5 TR, 5 Star rated, invertor technology. The complete outdoor unit shall consist of compressor, condenser coil, Expansion coil and capalliary tube whereas indoor unit shall include copper cooling coils, air blower and air filter. The heating should be based on reversible cycle. The split air conditioner should include multipurpose stand wall mounting out door unit stand with complete nuts and bolts and groutig charges etc including connecting copper tubing/ pipes of suitable size, insulated with insulating material with LCD remote, filled with refrigerent, connectig cable as reguired and specified includig all accessories complete all as specified and directed.
Supply, installation and commissioning of three phase, 40 KVA true online UPS system with automatic (Static switch) and manual bypass alongwith SMF battery bank of 30 Min Back up at full load, three phase AC input 415V, 50 Hz three Phase supply, complete all as specified and directed by Engineer in Charge.
Supply, installation and commissioning of three phase, 20 KVA true online UPS system with automatic (Static switch) and manual bypass alongwith SMF battery bank of 30 Min Back up at full load, three phase AC input 415V, 50 Hz three Phase supply, complete all as specified and directed by Engineer in Charge.
Supply and installation of voltage stabilizer of capacity 2.0 KVA, copper wound single phase naturally air cooled indoor type and designed for input variation between 120v to 280v with output voltage stabilized at 230v with accuracy of +/- 2.5% complete all as specified and directed by Engineer in Charge.
M/s Anil Engineers & Builders
KANWAL KUMAR GUPTA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .