Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Rejected-Technical 54 10 SHANTI NAGAR NEAR SHINDE CHATRI WANAVADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | Rejected-Technical Due to CIC Pending and valid reqd docs for unenlisted contractor not uploaded. |
| 2 | Rejected-Technical SURVEY NO 41 A 1 SUVIDHA DYANGANGA B1 11 WADGAON BUDRUK PUNE 411041 | PUNE | PUNE | MAHARASHTRA | 411041 | Rejected-Technical Adverse remark in WLR QE Dec 2025 |
Tender Value
₹3.7 Cr
EMD Value
₹4.5 L
Closing Date
24 Feb 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COMMANDER WORKS ENGINEER PUNE - 01
HEADQUARTERS COMMANDER WORKS ENGINEERS GEN CARIAPPA MARG, PUNE-411 001
81812 ADDITION / ALTERATION OF ACCIDENT AND EMERGENCY DEPT (MI ROOM) OF MH AT NDA KHADAKWASLA
2025_MES_746288_1
81812 CWE PUNE
Open Tender
Civil Works
Lump-sum
180 days
GE KHADAKWASLA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹2,000
GE KHADAKWASLA
₹4.5 L
Yes
14 Mar 2026
30 Dec 2025
3 Mar 2026
30 Dec 2025
24 Feb 2026
10 Feb 2026
31 Dec 2025 - 6 Jan 2026
SCH 'A' PART-I: BUILDING/STRUCTURES Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 5 signifies this fact only
Construction of Pump House building complete all as shown on arch and structural drawings complete all as specified and directed.
Construction of Under Ground (UG) Sump of capacity 25000 Gallon complete all as shown on arch and structural drawings complete all as specified and directed.
NOTE: Schedule ‘A’ Part II to VIII items have been Prepriced by MES and the Bidders shall insert their lumpsum cost in green field under Column-6 only.
Total amount of Sch 'A' Part-II (EARTHWORK AND EXCAVATION, SITE CLEARANCE & DEVELOPMENT)
Total amount of Sch 'A' Part-III (B&R ITEMS)
Total amount of Sch 'A' Part-IV (INTERNAL ELECTRIFICATION)
Total amount of Sch 'A' Part-V (AIR CONDITIONING & REFRIGERATION)
Total amount of Sch 'A' Part-VI (FIRE FIGHTING SYSTEM)
Total amount of Sch 'A' Part-VII (EXTERNAL ELECTRIC SUPPLY)
Total amount of Sch 'A' Part-VIII (SEWAGE DISPOSAL)
NOTE: Items in Schedule ‘A’ Part II to X items which are not Prepriced by MES are given in Sch 'A' Part - IX & Sch 'A' Part -X, Bidders shall insert their rate in Column-6 only and the Estimated rate indicated as "0.0" are for that purpose.
SCHEDULE 'A' PART- IX (MEDICAL GAS PIPE LINE)
S&F DIN Type Oxygen Outlets with probe as Per standards DIN 13260 and EN 737-1 Terminal units shall be capable of single-handed insertion and removal of the medical gas probe. The wall mounted first fix assembly shall consist of brass pipeline termination block with copper stub pipe secured between a back plate and a gas specific plate to allow limited radial movement of the copper stub to align with the pipeline. The gas specific plate shall be permanently fixed to the backplate etc complete all as specified and directed. Make : Altas Copco/Pneumatic Berlin/Tritech/REANIMED
S&F Main Oxygen Manifold of Size 2 x 4 for Indian type bulk cylinders, high pressure copper annealed flexible tail pipes complete with middle frame, chains for individual bulk oxygen cylinder, NRV's and 8 nos. pig tail pipes. It should be suitable to withstand a working pressure of 300 kg/cm2 and complete as specified and directed. It should confirm to HTM standard EN:13348:2016. Make - Aktiv /Tritech/Pneumatic Berlin
S&F Emergency Oxygen Manifold of Size 1 x 1 for Indian type bulk cylinders, high pressure copper annealed tail pipes complete with middle frame, chains for individual bulk oxygen cylinder, NRV's and 2 nos.pig tail pipes. It should be suitable to withstand a working pressure of 150 kg/cm2 and with MOX Regulator Single Stage Double Gauge 0-16 bar . It should confirm to HTM standard EN:13348:2016. Make - Aktiv/Tritech/Pneumatic Berlin
S&F Oxygen Fully Automatic Control 1350 lpm Panel, With Pneumatic Switch Over acieved Automatically, Automatic Reset for next cycle, Digital Pressure Indicator, Gas bank Status Indicator, Pressure Unit Options in bar, psi and kg/cm2 as per HTM standard EN-13348:2016/Medical grade incl relief valve to bleed pressure built up excess of 5.2 bar (75 PSI) confirming to BSEN:ISO 7396-12016. Optimized Residual Gas. Make - Ohio/Aktiv /Atlas copco/Pneumatic Berlin
S&F Oxygen Flow Meter 0-15 LPM With Humdifier Bottle (autoclave) with all accessories matching probe/adaptor shall be provided at one end of oxygen gas outlets and other end for flow meter with standards of HTM 02-01 EN:13348 - Make - Atkiv/Gardner Denver/Atlas Copco
VACCUM SYSTEM
S&F DIN Type Vacuum Outlets with probe as Per standards DIN 13260 and ISO 7396-1 , Terminal units shall be capable of single-handed insertion and removal of the medical gas probe. The wall mounted first fix assembly shall consist of brass pipeline termination block with copper stub pipe secured between a back plate and a gas specific plate to allow limited radial movement of the copper stub to align with the pipeline. The gas specific plate shall be permanently fixed to the backplate etc complete all as specified and directed. Make : Altas Copco/Pneumatic Berlin/Tritech/REANIMED
S & F ward vaccum regulator with an adjustable knob for precise vaccum control within a range of 0 to 760 mm hg with flow rate 25 LPM with collection jar 600ml made out of shatter proof, autoclavable polycarbonate with antibacterial filter as per ISO13485:2003 all as specified and directed. Make : Gardner Denver/Atlas Copco/Becker/Pneumatic Berlin
S & F ward vaccum regulator with an adjustable knob for precise vaccum control within a range of 0 to 760 mm hg with flow rate 25 LPM incl collection jar 1000 ml made out of shatter proof, autoclavable polycarbonate with antibacterial filter as per ISO13485:2003 all as specified and directed. Make : Gardner Denver/Atlas Copco/Becker/Pneumatic Berlin
S&F 3 HP Reciprocating, Tank Mount Vacuum Pump with Electricals and Anti-bacterial Filter. Tank Capacity 280 Ltrs. 1135 lpm, 40 cfm, Dimension (LxBxH in mm) - 1560 x 565 x 1115, Weight Approximate: 265 kg For : Insert after 265kg” comprising of following (a) No of cylinders=02 (b) Vaccum=29.4 inch/745mmHg (c) Outlet size=25mm (d) Connection lead (e) Direct on line starter suitable for 3HP motor (f) Medical vaccum filter :Borosilicate filter element with 99.995% efficiency with extended aluminium alloy body with incl powder coating suitable for 25mm pipe connection. . Make Anest Iwata - Model - TVLS30D - 28E / Indo air/Frankair
COMPRESSED AIR SYSTEM
S&F DIN Type Air 4 bar Outlets with probe as Per standards DIN 13260 and ISO 7396-1, Terminal units shall be capable of single-handed insertion and removal of the medical gas probe. The wall mounted first fix assembly shall consist of brass pipeline termination block with copper stub pipe secured between a back plate and a gas specific plate to allow limited radial movement of the copper stub to align with the pipeline. The gas specific plate shall be permanently fixed to the backplate etc. complete as required Make - Atkiv/Gardner Denver/Atlas Copco
S&F 3 HP Reciprocating Oil Free Air Cooled Tank Mount Air Compressor. Tank Capacity - 180 Ltrs. Single Stage, 14.6 cfm, Operating at 8.5 bar, Dimension (LxBxH in mm) - 1580 x 745 x 1000. Approximate Weight - 155 kg comprising of following (a) No of Stage=01 (b) Outlet size=25mm (c) Direct on line starter suitable for 3HP motor . Make - Anest Iwata. Model TFS30C-9-18E/Indo Air/Frank Air
S&F breathing air system Air dryer of cap 10 CFM, with following operating condition. Make Trident/Draeger /OSHA
(i) Voltage : 100-240 V AC, 50/60 Hz 1 Ph (ii) Power consumption: 40 Watt (iii) Max working pressure :16 bar (g) (iv) Minimum working pressure: 4 bar (g) (v) Rated inlet Temperature: 38 degree centigrade (vi) Rated inlet pressure: 7 bar (g) (vii) CO level: 10 PPM (Alarm Set point) as per NFPA99 (viii) Air quality : 2 degree Centigrade (POP) Pressure dew point. Alarm Set point as per NFPA 99 0.01 micron particle level. (ix) Cycle time: 4 min (x) The BAS should comprise of Prefilter of 5 micron, fine filter of 01 micron, Bacteria filter of 0.01 Micron. (xi) High quality carbon monoxide (CO) Monitor & Dew point monitor (xii) The Breathing dryer should meet breathing air standards as per NFPA 99, OSHA Grade D, European Pharmacopoeia & IS/ISO 7396 The Dryer & filter should confirm ISO 87573 Class -2 (outlet air quality), 97/23/CE (pressure directive), 89/392/CEE (Machinery Directive), 72/23/CEE (Low voltage) & CRN (Clinical Research Nurse)
S&F Air Regulator (2 Nos) 0 - 10 kg/cm2 suitable for 1/4"-1/2 ", 4" Analog Gauge 0-15 Kg cm2 with non return valves (NRV )=2 Nos) all as specified and directed Make ; Airmax Pneumatics /Kaymo/Atorse
S & F Three stage filtration system for medical compressed air system should be capable of arresting impurities at each stage with undermentioned phases. (a) PREFILTER made out of borosilicate element grade P) (Coalescing filter) to remove bulk liquid and large particles ,the filter should remove upto 5 Micron having green end cap (b)Stage-I: Vapour removal filter made out of borosilicate element grade X) separated filter for liquid droplets, particulate matter, upto 01 Micron . having end Red cap (c)Stage-2 made out of borosilicate element grade Y (Vapour element filter for remaining oil vapour &hydro carbon odours.particle remains upto 0.01 Micron . having end Cap-yellow. (d)Stage-3: borosilicate element grade A (high efficiency filter to remove bacteria,virus & other fine particulate matter ensuring the air is sterile,the particle remove less than 0.01Micron having Black End Cap - Make - Trident /OSHA/Draeger
Distribution Copper Pipe EN: 13348 M & L Medical Grade copper pipe with required copper fittings, All pipes shall be drawn half hard temp., solid drawn, seamless, phosphorous deoxidised, non-arsenic and degreased copper pipe conforming to EN BS: 13348:2008. The supplies of copper pipe would be accompanied with manufacturers test certificate for the physical properties of copper pipes and their Chemical composition. The supply of pipes be further substantiated with inspection certificate from the third party like Lloyds Register. etc. complete as required. Note: (i) Painting of medical gas pipe line with approved colour as per medical gas code of practice is incl in unit rate. (ii) Oxygen & other gases reqd for welding / brazing is incl in unit rate (iii) Nylon saddles, coupler Tee, elbow & socket are incl in unit rate. (iv) Scaffolding & other support structure will be arranged by the contractor.
M & L Copper Pipe 12 mm X 0.7 mmThickness
M & L Copper Pipe 15 MM X 0.7 mm thickness
M & L Copper Pipe 22 MM X 0.9 mm thickness
M & L Copper Pipe 28 MM X 0.9 mm thickness Note for Item 15.00 to 18.00 : Make Mandev/Rajco/Maxflow
ISOLATION VALVES
S&F Isolation Ball Valve 12 MM With fittings confirming to HTM02-01 EN 13348 med grade with all accessories
S&F Isolation Ball Valve 15 MM With fittings confirming to HTM02-01 EN 13348 med grade with all accessories -
S&F Isolation Ball Valve 22 MM With fittings confirming to HTM02-01 EN 13348 med grade with all accessories -
S&F Isolation Ball Valve 28 MM With fittings confirming to HTM02-01 EN 13348 med grade with all accessories Note for Item 19.01 to 19.04 : Make-RB/CIM/Legris/Andco
DIGITAL ALARM Supply,installation,testing & commissioning 3 gas alarm panel for pressure/vaccum level of medical gases like oxygen,nitrogen oxide &medical air with both visual & andible alarm comprising of following. (i)colour coded LED’S (Green for normal,yellow for warning,red for alarm) (ii)Andible alarm with adjustable volume(minimum 85Db at 1mtr)with distinct tones (low pressure,high pressure,system fault) (iii)Wall mounting arrangements (iv)High impact flame retardant M S housing with smooth finish and anti bacterial coating (v)AC power with backup from UPS- Make - Ohio/Operista/Amico/Atlas Copco/Pneumatic Berlin
Horizontal Bed Head Panel * Supply, fix, test and commissioning of Bed Head Panel, 1800 MM long, Horizontal type. The Bed Head Panel after fabrication should be anodised and then powder coated as per the color recommended by the hospital. There will be airtight Bakelite partition to separate Gas outlet point and electrical switch socket. Each switch socket should be electrically connected and terminated into a terminal block. So that, only one connection of Phase, Neutral & earth will be required to energize the entire panel. Configuration • Oxygen Outlets = 1 No • MA-4 Outlets = 1 No. • Vacuum Outlets = 1 No • Electrical Switch & Sockets 5/15A= 8 No's. • RJ-45 = 1 No • Rj-11 = 1 No & PROVISION for Nurse Call. • Stainless steel Infusion pump mount with rail clamp = 1 No • Two ways extendable stainless steel IV hooks with rail clamp = 1 No • Stainless steel Basket with rail clamp = 1 No • Monitor tray with rail clamp = 1 No • Aluminium clamp for Ward Vacuum unit = 1 No S&F VDE 0834 certified /approved bed head connection module for Patient terminal for non voice connection module to connect patient hand set shall consist of 1xRJ45 socket marked in colour and with measures to ensure that the push button is properly connected incl the auto disconnected mechanism with antimicrobial coating .1x5 pole DIN socket for connecting a diagnostic device with disconnection call. Make : Atkiv/ModulSpace Technik /WIESPL /Tanvi Enterprises
M & L for metallic wall support for medical gas pipe lines of various sizes made out of 40mm X 40mm X 5MM angle iron fixed at equal interval of 1mtr on wall with double anchor fasteners of 10mm X 100mm.The copper tubes will be braced with flat iron clamps made out of 20mm flat iron bent to shape of respected dia of copper tubing with the help of nut bolts of suitable size. All metallic structure is to be printed with to coats of synthetic enamel paint over a coat of red oxide primer. all as specified directed
SCHEDULE 'A' PART- X (MISC B/R AND E/M WORKS)
B&R PORTION S&F in repair shelves made of HDHMR (high density high moisture resistance) board manufactured with hard wood, prelaminated both sides white in colour 18mm thick water resistant, termite resistant, duly edge banded with PVC taping 0.8mm thick, cut to shape & size of shelves including taking down with existing one complete all as specified and as directed.
Supply and fixing in repair 18 mm thick UV board duly edge banded with 0.8 mm thick PVC taping for cup board shutters, shall be fixed with autoclosing hydraulic hinges and modular handles, design and colour as approved by GE, suitable for kitchen/ wash basin counter cabinet, etc including taking down old/ unservieable boards complete all as specified and as directed by Engr in charge (Make : Action tesa/ Kitply/ Archidlan) (Note: Auto close hydraulic Hinges shall be measured & Paid Separtely)
S&F stainless steel auto close/ hydraulic hinge suitable for shutter of not exc 0.50 sqm area complete all as specified and as directed.
S&F stainless steel hinge 50 mm long for cupboard shutter fixed with Self Tapping screws complete all as specified and as directed.
S&F 75 mm long stainless steel handles for cupboard shutter fixed with Self Tapping screws complete all as specified and as directed.
S&F Auto hinges, stainless steel, bright finish or electrogalvanised 30mm width of flaps complete all as specified and as directed.
S&F, Magnetic catches of brass body and striking plate in complete all as specified and as directed.
S & F in repair 5.50mm thick corner glass shelf with bracket etc complete all as specified and directed.
Supply & Fix 15 mm two in one angle valve chromium plated with wall flange and fancy type with high pressure screwed down and with CP flange of same make complete all as specified and directed
S&F in repair single lever basin mixer with popup waste system , Hot and Cold Facilites and 450 mm long braidaed hoses chromium plated complete all as specified and directed.
S&F in repairs single lever wall mixer with popup waste system, hot and cold facilites for 15 mm dia pipe and complete all specified and direcetd.
S&F in repair toilet paper holder with flap recessed type stainless steel Complete all as specified and directed complete all as specified and directed by Engr-in-Charge.
S&F in repairs elegent mirror PVC bathroom storeage cabinet of size 422x622mm, fixed with screws or PVC gutties, complete all as specified and directed.
M&L for Towel Ring of Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified and directed by Engr-in-Charge/GE
S & F in repair CP towel rail with lower hanger 630mm long ,ht-280mm and depth 140mm etc complete all as specified and directed.
S&F in repairs 15 mm angle valve chromium plated with wall flange and fancy type with high pressure screwed down and with CP flange of same make complete all as specified and directed.
S&F in repair MS powder coated 20 mm dia curtain rod including wooden polished brackets and wooden polished end knobs fixed with plugs & screws, complete all as specified and directed.
Taking down of existing tarfelt and cement plaster of any description and thickness on roof top including flashing and junction of parapet and cleaning existing roof top surface by brooming , wire brushing incl removing the debrish out complete all as specified and directed
Material and labour for complete removal of existing treatment from wall/ chajja/ roof projection surface by scrapping (nails, screws if any to be removed properly before scraping) to make the surface free from dust, loose paint and loose plaster to be completely removed by manually/mechnically means as directed by engr-in-charge and repair of external wall/Chajjas to be done with repair mortar to get even surface including preparation of old surface of wall/ceiling by filling cracks by crack fill paste good smoothen surface by sand paper and applying two coats of premium acrylic smooth exterior emulsion of approved colour with Excellent Dirt Pick up resistance with diluted with water as per manufacturer instructions applied over one coat of Smartcare Damp Prime Suprema Primer vertical walls with dilution of not more than 10% with forced coverage not more than 5 Sqm / Ltr as per manufacture's instruction and all coats incl primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI all as specified and directed. Allow 6-8 hrs to dry the surface in subsequent coats of paint and including necessary scaffolding at any height complete all as specified and directed
M&L for removing of existing plaster surface upto base level & cleaning the surface of roof/wall with wire brush with water throroughly to remove all dust/dirt and loose particles and applying 2 coats of damp proof 2K on an interval of 4 to 6 hrs (1st & 2nd coat should be perpendicular direction) as per manufacture instruction, after plaster the surface and apply painting to match the existing surface complete all as specified and approved by Accepting Officer
M&L for preparing old plastered/conrete surface of roof/wall with wire brush with water thoroughly to remove all dust/dirt and loose particles and applying 3 coats of Dr fixit New coat/Asian paint damp proof on roof/wall surfaces including crack seal sealent if required at crack portion of roof/wall allapplication as per manufacturer instruction and including warranty certificate provided by applicator/company.
M&L for Thorough cleaning work, removal of loose screed, repairing of the damaged portions. Making slope corrections and damaged portions near rain water outlet. Filling the annular space between concrete surface and rain water PVC pipe using non shrink grout after preparing the surface using sand paper and application of SBR Latex as a priming coat on the area. Mixing and pouring Conbextra GP2, high strength grout with clean and cool water at ratio of 0.16 on the prepared surface to make the bore packing water tight. The rate shall include necessay materials, tools and application procedure as per manufacturer's specification
M&L for preparing the surface, removal of loose particles, damaged portions and after jet wash the complete area. Opening the damaged joints, grinding those marked joints, applyhing bonding agent single component acrylic polymer emulsion designed as a curing membrane (VOC content of 13.5g / litre) further filling it with polymer repair dual shriknage repair mortar. Providing and laying shrinkage-controlled polymer modified single component, alkaline resistant fibre reinforced, thixotropic, cementitious patch repair mortar supplied in 25 kg moisture resistant bag when mixed with clean water at w:p ratio 0.18, achieves are as following: (a) Compressive strength shall have (BS 1881 Pt.116) -> 20 Mpa at 1 day & > 45 Mpa at 28 days, (b) Tensile Strength shall have (BS 6319 Pt.7) > 2.5 Mpa at 28 Days, (c) Flexural Strength shall have (BS 6319 Pt.3)>7 Mpa at 28 days, (d)Drying shrinkage to ASTM C 157-93, 28 days < 1000 microstrain capable of applying upto 50 mm thickness in single layer. (e) Shrinkage controlled, polymer modified, fibre reinforced cementitious repair morta shall have CE (CE29842) marking and compliance according to Construction Products Directive 89/106/EEC (CPD).
M&L for providing and application of protection system to external stone/concrete surface after proper surface preparation and cleaning to remove any laitance, algae, fungal, foreign materials using suitable repairing method followed by uniform application of colorless, ready-to-use, silicone water repellent silane-siloxane solution that penetrates porous substrates like brickwork, concrete, and stone, creating a water-repellent surface designed to reduce water and water-borne salt absorption, while still allowing water vapor to escape etc. complete including all tools and tackles as per manufacturers specification and as directed by EIC. (a) Product shall be complies with BS 6477-92 Class A and Class B as silicone-based water repellent
M&L for repair damaged chajja & honeycomb patches using ready to use repair mortar. Recommended Product: Polymer modified single component, alkaline resistant fibre reinforced, thixotropic, and cementitious patch repair mortar. Recommended product should achieve are as following: - (a) compressive strength shall have (BS 1881 Pt.116) -> 20 Mpa at 1 day & > 45 Mpa at 28 days, (b) Tensile Strength shall have (BS 6319 Pt.7) > 2.5 Mpa at 28 Days, (c) Flexural Strength shall have (BS 6319 Pt.3)>7 Mpa at 28 days, (d) Drying shrinkage to ASTM C 157-93, 28 days < 1000 microstrain. (e) Remove the loose particles, latiances and contamination if any. Mark the area to be patch repaired, Shrinkage controlled, polymer modified, fibre reinforced cementitious repair morta to be mixed with recommended quantity of water and apply to prepare surface and finishing the same with trowel carefully compacting the same around the rebars and finishing to bring it in line with existing concrete surface etc., where the thickness of application is less than 50 mm in patches as per specification after applying bonding coat. (f) Shrinkage controlled, polymer modified, fibre reinforced cementitious repair mortar cement-based material should be cured immediately. Price considering thickness of repair 10mm. Curing to be executed by suitable curing compound.
S&F Aluminium Composit Panel (ACP) sheet with 1"x1.5" aluminium tube over the plain or semi circuler framed trusses / beam of gates including flat or sloped with circular or notching and waste on ACP cutting ,ACP shall meet undermentioned tech requirements. (i) Coating on front : high quality polymer resin. (ii) Core : FR Core (Fire retardant) (iii) Thickness : 4mm (iv) Weight : 7.50Kg/Sqm (v) Width: 1205mm (vi) Length: 2400 to 4880mm (vii) Structure: aluminium panel are protective film,clear coating PVDF,primer coating,antirust layer,aluminium skin and polyethylene. (v) Temp Resistance : Between -50C to +80C Note : Rate is deemded to be inclusive of scaffolding required and joint sealing
M&L for steel chromium plated letters or figures in Hindi& English (Indian) of appropriate shape & size as per site requirement and fix with appropriate material complete all as directed by Engineer-in-Charge
M&L for NDA logo of brass type/steel chromium plated approximate 2 feet height normally fix on wall/gate etc complete all as directed by Engineer-in-Charge
M&L for 4 mm dia wire mesh 20 Gauge GI wire netting in 40X40X5mm MS angle frame fixeded to column etc complete all as specified and directed.
Supply & Installation of Sintex Prefabricated SMC Panel in the size of 2.00 mtr lengthX2.00 mtr width X 2.5 mtr height having 10KL Capacity (10000 Liter) broadly as per specification enclosed herewith Code No. GSPT-DP-10KL-2.0X2.0X2.5 MTR Note : Rate is deemded to be inclusive of Make arrangement of crane, lifter, safety precaution, scaffolding height upto 10.00 mtr etc.
INTERNAL ELECTRIFICATION S & F RJ-11 telephone socket with transparent shutter 2 module alongwith flush metal box 2 module and front cover plate 2 module all as directed.
S &F for LAN RJ-45 Jack With Cat 6 socket UTP Cat with transparent shutter 1 module alongwith flush metal box 1 module and front cover plate 1 module all as directed.
S &F for TV socket with transparent shutter 1 module alongwith flush metal box 1 module and front cover plate 1 module all as directed.
S&F Modular USB Charger all as specified and directed by Engr-in-charge. Make: HavellsRoma/Vinay/Crabtree cat part no ACWKRXG002
S&F LED ROJO 7 W B22 RED/GREEN LAMP all as specified and directed by Engr-in-Charge.Make- Havells-LHLDBWEB4P8R007 / Wipro/Luker.
S&F chandelier fitting Gold color brass materialb12 heads E14 cap type ø 610 x H920 with Chrome finish with twin core twisted flexible copper condctor cable from ceiling rose all as specified and directed by Engr-in-charge. Make- Jaguar - CHL-GLD-S1009A / Havells / Bajaj
S&F in replacement of honor board/Picture Light LED (warm white) fitting of 1x12 Watt individual LED lenses, chorme coloured complete all as specified and directed.
S&F in repairs surface /recess mounted with PC housing LED down lights 18 W LED 6500K, 240Volts and glare free symmetrical illumination suitable for POP ceiling, Environmental friendly, new generation, energy saving, high power LED as a light source with clear diffuser including connecting with twin core wire and also matching to the adjacent ceiling surfaces carefully all as specified and directed. ceiling cutout ø 220mm,height ø 36mm Note: The quoted price shall include the cost of Light and its driver. Make: Havells -GLOWDLR18WLED830S/ Philps/Luker
S & F and Replacement of Shadow less LED OT light with adjustable foucsing system With adjustable colour temperature Memory function,High quality sterilizable handle,with protective fire resistance ESG safety glass for scratch proof,fast disinfection process protects UV and IR rays and improve light penetration With special european design for ventilation of heat body made up of high quality Fire free resistance Polymer.with followingTECHNICAL DATA: INTENSITY - 1,30,000 lux + Satellite 1,30,000 Lux or above SIZE OF LIGHT FIELD-25 CM or better COLOUR TEMP-4000-4500K degree K or more , Colour rendering index shoud not be less than 95,Depth of illumination shoud not be less than 100 cm, illumination adjustment 30% to 100%, Light patch diameter adjustable at light handle, NUMBER OF LED- 76+76 DIAMETER OF LIGHT-500MM*2 BRIGHTNESS CONTROL- Capacitive touch panel POWER SUPPLY-220V/50Hz AC Endo Mode & Memory Function include With Battery Back up Make-TECHNOMED CEILING LED SURGICAL LIGHTSMODEL:TMI Hex CT 4+4/Dr Mach Note: Fixing/Mounting of OT light on Wall/Ceiling arranment such as Mounting bracket/downrod/flat iron (Heavy duty) with all accessories and fabricated work as per req site the cost of same is deemed to be included in the quoted rate.
S&F of high speed wall mounted fan of sweep 400 mm,,Full copper motor,auto thermal overload protection,compact style and powder coated gurads & pull cord switch for speed regulation and oscillation control including connectng up the power cord to the socket and necessary fixing accessories all as specified and directed.Make:Crompton or equivalent in Havells/Orient/automberg
Supply and fixing factory made epoxy powder coated Distribution Board TP & N 4 way double door (VTPN MCCB DB) MCCB as In comer, with metal door (IP-43 protection) fabricated from CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout flush to wall and making good disturbed surface and touch up with the same finishes complete all as specified and directed by Engr-in-charge. Note:MCBs/ MCCBs will be measured and paid seperately under respective Sch A item in the schedule
AIR CONDITIONING S & F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 270 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA. Make : V-Guard/ Vinitec/ Microtek.
M&L for high thermal conductivity and corrosion resistant Copper Tube of size 1/4 inch (6mm) with nitrile rubber insulation including all fittings and fixing accesssories used in extended length complete all as specified and directed.
M&L for high thermal conductivity and corrosion resistant Copper Tube of size 1/2 inch (13mm) with nitrile rubber insulation including all fittings and fixing accesssories used in extended length complete all as specified and directed.
M&L for high thermal conductivity and corrosion resistant Copper Tube of size 5/8 inch (16mm) with nitrile rubber insulation including all fittings and fixing accesssories used in extended length complete all as specified and directed.
M & L for making holes by core cutting machine on stone/concrete / brick walls.Dia of hole not exc.50mm and thickness of wall 50cm to 70cm for entry of suction and discharge pipes of AC and making good disturbed surfaces with cement mortered and finally finished with plaster of paris and painted the distrubed surfaces with existing type of paint and tint complete all as directed.
FIRE FIGHTING SYSTEM Supply and fix Mild Steel class 'C' diesel pump exhaust pipe 150mm dia with one layer of 10mm thick asbestos rope insulation and including all fitting clamp/ structural steel supports for extension of diesel engine exhaust pipe complete all as directed. (NOTE : Fire fighting system shall be executed by the approved Fire Fighting Agency. The Contractor shall furnished MOU with the Firm for the approval of GE.)
Supply and fix strainer Y-type conforming to (IS: 210 FG 200) of 50mm dia size all as specified and directed.
M&L for fabrication of water suction/delivery header pipe using C-Class MS pipe of suitable size/dia as required at site, provided with both end flanged dead plugs for future extensions if any, having minimum two nos 15-20cm long flanged inlet suction water pipe connections using suitable size MS pipe and heavy duty drilled flang, and minimum four or more Nos 15-20cm long flanged delivery water pipe connection points using suitable dia size MS pipe and heavy duty drilled flang including all necessary cutting drilling, welding work as per site requirement and necessary accessories like drilled flanges, blank flange for dead plug, flanged reducers/tapers, 15mm socket end nipples for connection of water pressure gauge, suitable size GI Nut, Bolts, washers, rubber gaskets, PCC or brick work for support to header pipe etc including making necessary inlet and outlet pipe connections using special pipe fittings all as directed and specified. Note : Suitable dia MS pipe with special fittings if any required shall be measured and paid separately under relavant item. However cost of rubber gaskets, 15/20mm GI socket/nipple, GI Nut, bolt and washer shall include in quoted rates.
Supply and fix Pipes ERW Steel 150 mm dia including specials fittings as per IS-3589 (1981) thickness 6.0 mm duly painted with two coats of synthetic enamel paint (color as per IS norms of fire fighting color code) over a coat of Zinc chromate pirmer all as specifed and directed (for fabrication of header pipe) :-
Supply ,laying, jointing, testing and commissioning Ductile iron pipe 100mm dia with spigot and socket end centrifugally cast (spun) class K-7 conforming to IS-8329-2000 in any length laid in trenches complete all as specified and directed . Note: Quoted Rate should include cost of laying, excavation, jointing etc.
M & Labour for Valve Pit Chember of size 900x900x500 mm (Internal Dimension) with block massionary including all necessary excavation and earth work in any type of soil, returning filling and disposal of spoil to a distance exc 50m and depositing where directed, PCC in foundation of the mix (1:4:8) type D-2 ( Using 40mm graded stone crushed stone aggregate) brick masonary 15 mm thick plaster work in CM 1:4 over all internal and external wall with white wash of both surface and MS sheet cover of suitable thickness for with hinges, equal angle iron frame and necessary locking arrangement painting of synthetic Enamel paint over coat of red oxide primer on MS Plate all as specified and directed .
Supply, Installing & testing and commissioning LT starter panel,CPRI approved,powder coated, 6 Zone control for automatic operation of fire pump with digital programmble controller module for fire fighting electric supply control, factory made Indoor type floor mounted, LT panel Cubical type suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated Copper bus bar 200 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 54 class protection and made of 2.0mm thick Stainless steel sheet and 40 x 40 x 5mm thick angle iron frame work, both front & rear opening type with aprons for cable entry with double door shutter and locking arrangement, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 6 Sqmm. The scope of work includes the following
Supply and fix Dual plates CI wafer type spring loaded check valve (high pressure NRV), tested to pressure of 15 kg to Sqcm , disc material Stain less steel with PN-16 complete set for 150mm bore dia pipes :-
Supply and fix Automatic air release valve 50mm dia suitable for domestic water with 50mm gun metal stop valve complete.
Supply and fix MS flanged pipe of following nominal bore, heavy duty, for multistorey building duly painted with two coats of synthetic enamel paint (color as per IS norms of fire fighting color code) over a coat of Zinc chromate pirmer :-
(a) 50mm nominal bore
(b ) 40mm nominal bore
(C) 25mm nominal bore
S & F cast iron air release valve alongwith two air outlets 50 mm dia bore including stainless steel floats and working parts and fusion bonded epoxy coating in PN 1.6 as per IS 14845 complete fixing up in MS pipe down comer dia 50 mm.(one each bldg)
Supply & fix fire hydrant landing valve type-A (single head outlet) of 63 mm dia conforming to IS 5290.
S&F 63 mm dia gun metal branch pipe and nozzle confirming to IS-903 all as specified and directed.
Supply and fix fire hydrant stand post with provn of single outlet conforming to IS 909 outlet 63mm dia inlet 80mm dia and raiser of 600mm length all as specified and directed
M&L for concealed point wiring with Armoured cable 2 core for FAS of 0.75sqmm or suitable size for above Control Panel including PVC conduit not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unseathed FRLS cable size 0.75 sq mm copper conductor as earth wire to common earth dolly all as specified by Engr-in-charge.
M&L concealed point wiring with Armoured cable 2 core for FAS of 1.5 sqmm or suitable size for above Control Panel including PVC conduit not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unseathed FRLS cable size 1.5 sq mm copper conductor as earth wire to common earth dolly all as specified by Engr-in-charge.
Supply , install, testing and commissioning of cubical housing cabinet type LT panel of size 500 mm x 400 mm x 300 mm, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15 mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved and built upon 35 x 35 x 3 mm size angle iron frame work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment.Necessary foundation work as required at site and comprising 200A, 36KA, 3P MCCB, Neon RYB LED Indicator and Denger sign Board complete all as directed.
Providing and fixing 6 kg capacity Multipurpose dry chemical powder (ABC) type (IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged all as specified and as directed. (02 Nos in Ground floor, 01 Nos in first floor and 01x Pump house)
Providing and fixing CO2 type fire extinguisher of 3 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683. Extinguisher shall be painted with red enamel apint and fixed to wall with bracket complete all as specified and as directed. (02 Nos in Ground floor, 01 Nos in first floor and 01x Pump house)
Providing and fixing 9 Ltr capacity Foam type (IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged all as specified and as directed.(02 Nos in Ground floor, 01 Nos in first floor and 01x Pump house)
M & L for making holes by core cutting machine on stone/concrete / brick walls.Dia of hole not exc.20mm to 40mm and thickness of wall 50cm to 70cm for entry of Armoured cable 2 core/GI Pipe for FAS and making good distarbed surfaces with cement morter and finally finished with plaster of paris and painted the distrubed surfaces with existing type of paint and tint complete all as directed.
M & L in replacement submersible copper cable 3 core pvc insulated 1100V grade conforming IS 694 of size 6 sqmm complete all as directed.
EXTERNAL ELECTRIFICATION S & F of 60 KVA 3 phase UPS for 30 min back up three phase AC input 300 to 450 V and output three phase AC voltage 415 V ± 1% LF 3P/3P 360 Online UPS with inbuild isolation transformer IGBT rectifier True-on-line double conversion DSP controller PWM technology high efficiency design of capacity 60 KVA with 42 numbers of 100 AH 12V SMF Battery and including MS battery stand, interlinking cable for connection and installation, testing & commissioning at site all as specified and directed by Engineer-in-Charge.
Supply and laying 40 x 32 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 6 to 16 Sqmm 4 core complete all as specified and directed by Engr-In-Charge.
Supply and laying 50 x 38 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 25 to 35 sqmm 3.5 core complete all as specified and directed by Engr-In-Charge. .
Supply and laying 120 x 103 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 185 to 240 Sqmm 3.5 core complete all as specified and directed by Engr-In-Charge. .
S & F PVC insulated copper conductor 3 core 1.5 sqmm for from weather proof DB to garden light fitting ,multistranded complete all as specified and directed. Make Polycab/Havells/Standard
Supply and Fixing Integral LED Bollard 10 watt outdoor light made in diecast aluminium housing with decorative clear opal acrylic diffuser and IP 65 on PCC foundation with suitable nut and bolts as per site requirement complete all as specified and directed Make- Luker Cat No LOBRD60 or eqv in Havells/Bajaj
Supply and Fixing Circular LED 45 post-top offering excellent uniform illumination and aesthetics in one go. Made up of Pressure Die Cast aluminium body and opal PC cover. IP 66 and IK 07 rating rating ensures it stands varied environmental conditions.Suitable for pole dia Ø 76 mm complete all as specified and directed
Supply and Fixing Aesthetically designed decorative hot dipped galvanised mild steel step dia Ø 76 mm pole with grey powder finish. Window - Plasma cut & duly chamfered opening window of 300x110 mm for terminal connections & mounting accessories with PCC foundation. Window cover is fitted with allen screws to the pole complete all as specified and directed
S&F distribution box 2 Module 230V, 5 HZ, IP-65 & IK-09 Class-II, weatherproof cabinets, door and cabinet fully reversible, removable chassis and faceplates, including weatherproof glands, rails qty-1 Nos, coppper fork type 100 A busbars as short link including end caps, complete all as specified and directed Make: Legrand Catpart No 601932 or equvaleint in L&T/Schinder
Supply and fix of 'C' Curve MCB SPN 10 Amps working on 240 volts, 50 HZ,10 KA all as specified and directed by Engr-in-charge.
Supply & Installation including testing and commissioning of Feeder Pillar Panel weather proof outdoor type double door, fabricated out of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7032 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, double door type with locking arrangement for front and back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with Aluminium bus bars of high conductivity aluminium alloy, suitable for 3 phase 4 wire system (R,Y,B,N) rating not less than 400 Amp. The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment.
The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured. All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers. The panel shall be provided with digital multifunction meter with accuracy Class 1 with RS 485 Parameters with cast Resign CTs etc and RYB, ON, OFF & Trip LED indicating lamps at incoming. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board, Name plate for Feeder Panel & all incoming and outgoing MCCBs etc. The panel shall be provided 4 Nos 50x50x6 mm thick angle iron supports of not less than each 1.2 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement . All MCCBs shall be provided with spreader links with phase separators on both side and suitable extended rotary handles for all Incoming & Outgoing MCCBs complete all as specified and as directed. The overall size of the panel shall not less than 1500mmX600mmX1200mm (LxDxH). The panel shall be provided with 2 Nos of Earting Terminals one on each side of the Panel with earth strip, suitable size of SS Cable glands for all incoming & outgoing XLPE Cable and including following accessories:- (a) ON Load change over switch four pole with advance neutral 250 Amps Current rating manual chnageover front side handle operated conforming to IS 13947 (Part-3) including RYB Indication lamp both incomimg cables. (b) MCCB 4 Pole, 415 Volts, 160 Amp with Thermal Magnetic release, 36 KA, Conforms to IS/IEC 60947-2, Ics = 100% Icu suitable for Isolation, Adjustable Overload setting : 0.8-1.0 x In, Magnetic Adjustable 5 - 10 x In with both side of spreader links and phase separater etc. – 01 No (Incoming) (c) MCCB 4 Pole, 415 Volts,125 Amp with Thermal Magnetic release, 16 KA, Conforms to IS/IEC 60947-2, Ics = 100% Icu suitable for Isolation with Adjustable Overload setting : 0.8-1.0 & both side of spreader links and phase separater etc. - 01 No (outgoing) (d) MCCB 4 Pole, 415 Volts,63 Amp with Thermal Magnetic release, 16 KA, Conforms to IS/IEC 60947-2, Ics = 100% Icu suitable for Isolation with Adjustable Overload setting : 0.8-1.0 & both side of spreader links and phase separater etc. - 03 No (outgoing) (e) Isolator 4 pole 40 Amps with adjustable setting -02 Nos (outgoing ) (f) Digital Timer switch with Power contactor 40 Amps 3 pole 415 volts with Control relays (Auxiliary Contactors) .- 01 Set
Supply & Installation including testing and commissioning of Feeder Pillar Panel weather proof outdoor type double door, fabricated out of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7032 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, double door type with locking arrangement for front and back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with Aluminium bus bars of high conductivity aluminium alloy, suitable for 3 phase 4 wire system (R,Y,B,N) rating not less than 400 Amp. The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment.
The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured. All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers. The panel shall be provided with digital multifunction meter with accuracy Class 1 with RS 485 Parameters with cast Resign CTs etc and RYB, ON, OFF & Trip LED indicating lamps at incoming. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board, Name plate for Feeder Panel & all incoming and outgoing MCCBs etc. The panel shall be provided 4 Nos 50x50x6 mm thick angle iron supports of not less than each 1.2 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement . All MCCBs shall be provided with spreader links with phase separators on both side and suitable extended rotary handles for all Incoming & Outgoing MCCBs complete all as specified and as directed. The overall size of the panel shall not less than 1500mmX600mmX1200mm (LxDxH). The panel shall be provided with 2 Nos of Earting Terminals one on each side of the Panel with earth strip, suitable size of SS Cable glands for all incoming & outgoing XLPE Cable and including following accessories:- (a) ON Load change over switch four pole with advance neutral 250 Amps Current rating manual chnageover front side handle operated conforming to IS 13947 (Part-3) including RYB Indication lamp both incomimg cables. (b) MCCB 4 Pole, 415 Volts, 160 Amp with Thermal Magnetic release, 36 KA, Conforms to IS/IEC 60947-2, Ics = 100% Icu suitable for Isolation, Adjustable Overload setting : 0.8-1.0 x In, Magnetic Adjustable 5 - 10 x In with both side of spreader links and phase separater etc. – 01 No (Incoming) (c) MCCB 4 Pole, 415 Volts,125 Amp with Thermal Magnetic release, 16 KA, Conforms to IS/IEC 60947-2, Ics = 100% Icu suitable for Isolation with Adjustable Overload setting : 0.8-1.0 & both side of spreader links and phase separater etc. - 01 No (outgoing) (d) MCCB 4 Pole, 415 Volts,63 Amp with Thermal Magnetic release, 16 KA, Conforms to IS/IEC 60947-2, Ics = 100% Icu suitable for Isolation with Adjustable Overload setting : 0.8-1.0 & both side of spreader links and phase separater etc. - 03 No (outgoing) (e) Isolator 4 pole 40 Amps with adjustable setting -02 Nos (outgoing ) (f) Digital Timer switch with Power contactor 40 Amps 3 pole 415 volts with Control relays (Auxiliary Contactors) .- 01 Set
S & F of installation, testing and commissioning of Busbar panel weather proof outdoor type single door, fabricated out of 2 mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-54, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with aluminium bus bars electrolytic grade of 400 Amps current rating including required size of nut bolts for fixing of cables upto 150 Sqmm. The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding and fix horizontally. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment. All joints and connection shall be done with galvanised or cadmium plated high tensile nuts, bolts, washers and AL Lugs etc. The panel shall be provided with 04 Nos 50mmx50mmx5mm thick angle iron supports of not less than each 0.6 mtr height duly painted with anti corrosive black paint including earth work and grouted in PCC 1:3:6 at suitable depth as per site requirement including taking down existing one. The overall size of the Busbar panel shall not be less than 500mmx300mmx700mm (LxWxH) including 4 Nos cable entry holes suitable for cable entry up 3.5C 150 Sqmm at bottom complete all as specified and directed Engr in Charge.
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.64 MB
BOQ_835672.xls
BOQ • 0.43 MB
Drg_PumpHouse.pdf
Additional Documents • 9.09 MB
81812TENDERDOCS.pdf
Tender Documents • 5.84 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .