Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 104 A SYNTHOFINE ESTATE OFF AAREY ROAD GOREGAON EAST MUMBAI MAHARASHTRA 400063 | MUMBAI SUBURBAN | MAHARASHTRA | 400063 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 16 T V INDUSTRIAL ESTATE S K AHIRE MARG WORLI MUMBAI MAHARASHTRA 400030 | MUMBAI | MAHARASHTRA | 400030 | Admitted-Finance |
| 4 | Admitted-Finance B 5 F I E PATPARGANJ INDUSTRIAL AREA EAST DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | Admitted-Finance |
| 5 | Rejected-Technical GLYPTIC RAIPUR P O BHITA BURDWAN 713102 | BURDWAN | PURBA BARDHAMAN | WEST BENGAL | 713102 | Rejected-Technical TECHNICALLY NOT ACCEPTABLE |
Tender Value
Refer Docs
Closing Date
26 Nov 2024, 3:00 pmClosed
SEKAR HIRUDHAYAM
TECHNIP ENERGIES INDIA LTD, CHENNAI
SUPPLY OF FIRE ALARM SYSTEM (FAS) NUMALIGARH REFINERY EXPANSION PROJECT
2024_NRL_830746_1
TP/082176C/NRL/PQ/146A
Open Tender
Electronics Equipment
Supply
240 days
NUMALIGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
Exempted
ONLINE
23 Apr 2025
15 Oct 2024
27 Nov 2024
15 Oct 2024
26 Nov 2024
15 Nov 2024
23 Oct 2024
Material Requisition (MR) Ref:TP-1ZZZA-IC-RFQ-0024_D4 Design, Engineering, manufacture of material and bought out components procurement, Assembly at shop, System Engineering, Configuration and programming, supply, testing and inspection (Factory Acceptance Test, IFAT & System Integration Test), Packing & forwarding, Transportation, Documentation, Mandatory spares , commissioning spares, special tools and tackles, consumables erection materials, supervision of site installation, site testing, pre-commissioning, loop checking, site acceptance test, Hand over to client and other associated work includes associated residual engineering and Additional Services as required (e.g. Site services, training, warranty) as per enclosed specification/licensor specification, system architecture drawing, JSS, datasheet and other codes and standards or referred comprising of the below indicated items.
Supply of FAS Cabinets, Consoles & Instruments in MCR-2 building and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No: 1.1 to 1.33
Supply of FAS Cabinets & Instruments in SRR-9 building and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No: 2.1 to 2.29
Supply of FAS Instruments in SS-17 building and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No: 3.1 to 3.27
Supply of FAS Cabinets & Instruments in SRR-10 building and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No: 4.1 to 4.29
Supply of FAS Instruments in SS-18 building and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No: 5.1 to 5.27
Supply of FAS Instruments in Existing SS-5 Switchgear building and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No: 6.1 to 6.14
Supply of FAS Instruments in switchgear building near ETP and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No: 7.1 to 7.14
Supply of FAS Instruments in Local Control room (LCR) building and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No:8.1 to 8.27
Supply of FAS Instruments in Fire water pump house building and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No: 9.1 to 9.14
Supply of FAS Instruments in MRSS control building and SS-21 and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No: 10.1 to 10.28
Supply of FAS Instruments in GIS hall and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No: 11.1 to 11.13
Supply of FAS Instruments in GIS room and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No:12.1 to 12.17
Supply of FAS Cabinets & Instruments for Utility control room (CR-3) and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No:13.1 to 13.42
Supply of FAS Cabinets & Instruments for CR-2 building and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No: 14.1 to 14.29
Supply of FAS Instruments for SS-13 building and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No:15.1 to 15.27
Supply of FAS Instruments for SS-10 building and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No:16.1 to 16.26
Supply of FAS Cabinets & Instruments for SS-14 building and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No: 17.1 to 17.37
Supply of FAS Cabinets & Instruments for SRR-8 building and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No: 18.1 to 18.38
Supply of FAS Cabinets & Instruments for SRR-4 building and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No: 19.1 to 19.41
Supply of FAS Cabinets & Instruments for SRR-3 buildingand it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No: 20.1 to 20.40
Supply of FAS Instruments for SS-11 building and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No: 21.1 to 21.24
Supply of FAS Cabinets & Instruments for SRR-2 building and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No: 22.1 to 22.39
Supply of FAS Instruments for SS-19 building and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No: 23.3 to 23.26
Supply of FAS Cabinets & Instruments for SRR-7 building and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No: 24.1 to 24.40
Supply of FAS Instruments for SS-15 building and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No: 25.1 to 25.24
Supply of FAS Cabinets & Instruments for SRR-6 building and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No: 26.1 to 26.38
Supply of FAS Cabinets & Instruments for SRR-5 building and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No:27.1 to 27.42
Supply of FAS Instruments for SS-16 building and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No: 28.1 to 28.24
Supply of FAS Cabinets & Consoles in Fire station building and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No: 29.1 to 29.5
Supply of FAS Cabinets in HGU CR-1 building and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No:30.1 to 30.2
Supply of FAS Instruments in First aid room and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No: 31.1 to 31.15
Supply of FAS Instruments in Canteen and it's associated Instruments and accessories as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 MR S.No: 32.1 to 32.18
Supply of Mandatory Spares shall be as listed in MR with document reference:TP-1ZZZA-IC-RFQ-0024_D4 (MR S.No: 33.1 ) . Note: Spares listed in document reference:TP-1ZZZA-PQ-PRC-0005 (but not listed in this RFQ) shall also be quoted by the bidder.
Site Services for supervision of installation, erection, wiring,calibration,configuration, testing , pre-commissioning, commissioning activities and during job execution of fire alarm system as per clauses listed as part of Material requisition (MR) with Ref:TP-1ZZZA-IC-RFQ-0024-D3 and its documents. MR S.No: 34.1 Note: Atleast 2 Engineers+ 6 technical Staff + sufficient assistants (as per bidder's assessment per day shall be deputed by the bidder for this activity) as per site requirement. During job execution, if sufficient front is not available at site, Bidder may be required to mobilize as well as demobilize it's resources (Manpower) multiple times (max. 5 times) as per instruction of EIC. However, Prior intimation with sufficient time will be given to bidder for every mobilization /demobilization based on site readiness. Bidder shall note this requirement and shall comply without any additional financial implication to NRL as per site requirement. Refer NOTE-9 in Instruction Note to BOQ
Site service support during unit start-up/unit commissioning activity (for Configuration, Trouble shooting, correction/ modification etc.) for Fire alarm system by deputing residential group of system experts & sufficient electricians / technicians - atleast 2 Engineers+ 6 technical Staff + sufficient assistants (as per bidder's assessment per day shall be deputed by the bidder for this activity) at site on daily basis - 24x7 basis as per site requirement during unit start‐up/ unit commissioning activity till the commissioning and stabilization of the unit operation as per requirements stated in MR and its documents. MR S.No: 34.2 Refer NOTE-10 in Instruction Note to BOQ
Post commissioning Operation & Maintenance (Comprehensive) service as per requirements stated in MR and its documents. Post commissioning Operation & maintenance (Comprehensive) service by deploying a residential group of System Experts/Engineer of OEM/OEM'S representative and technical assistant on daily basis at NRL site. Deputation of residential staff (ateast 1 Engineer (Diploma/ BE with atleast 1 year experience in Fire Alarm system) with 5 technical assistants) at site on daily basis. MR S.No: 34.3 Contractual period: 2 years from the commissioning of the system with provision of additional 1 year extension at the same terms and condition for 1 year. Refer NOTE-11 in Instruction Note to BOQ
Training Services (Hardware & Software Operation and Maintenance Training) for 5 nos of owner's personnel for all items of Fire Alarm System as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 at FAS vendor's works for 3 Days MR S.No:34.4 - (a)
Training (Operation,Maintenance) to 5 nos of owner's personnel for Fire Alarm System as per MR ref:TP-1ZZZA-IC-RFQ-0024_D4 at Site for 3 Days. The quoted rate shall include travel, Boarding, Lodging, local transport, medical, all insurance including third party, income tax, all taxes & all other incidental charges MR S.No:34.4 - (b)
New Fire Engineers Pvt. Ltd. (BID ID -3123385)
Willstrong Solutions Pvt Ltd (BID ID -3126606)
Lambda Technologies LLP (BID ID -3123245)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .