| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC GROUND FLOOR M NO 132 3 E VITTHAL PLAZA MALEGAON ROAD NEAR DENGALE GARDEN KASBA BARAMATI DIST PUNE MAHARASHTRA 413102 | BARAMATI | PUNE | MAHARASHTRA | 413102 | ₹1.0 Cr Quoted ₹88.2 L | L1 | Accepted-AOC quoted lowest |
| 2 | L2₹1.5 Cr+₹56.9 L (64.6%)Rejected-Finance OFFICE NO 301 VASANTASAKHA PLAZA NARHE PUNE MAHARASHTRA 411041 | PUNE | PUNE | MAHARASHTRA | 411041 | ₹1.5 Cr+₹56.9 L (64.6%) | L2 | Rejected-Finance second lowest |
| 3 | L3₹1.5 Cr+₹63.7 L (72.3%)Rejected-Finance | ₹1.5 Cr+₹63.7 L (72.3%) | L3 | Rejected-Finance third lowest |
| 4 | L4₹1.5 Cr+₹64.4 L (73.0%)Rejected-Finance | ₹1.5 Cr+₹64.4 L (73.0%) | L4 | Rejected-Finance fourth lowest |
| 5 | L5₹1.6 Cr+₹68.4 L (77.6%)Rejected-Finance | ₹1.6 Cr+₹68.4 L (77.6%) | L5 | Rejected-Finance fifth lowest |
Tender Value
Refer Docs
Closing Date
14 Mar 2024, 3:00 pmClosed
President, Bana Health Farmer Producer Company Ltd
Varkute (Bk), Loni Devkar, Indapur, Pune
SUPPLY INSTALLATION TESTING AND COMMISSIONING OF REFRIGERATION SYSTEMS
2024_DOAWB_1013026_1
Pune/BanaFPC/Goods/2024/4
Open Tender
Farm Machinery and Equipments
Item Rate
30 days
Varkute Bk Loni Devkar Indapur Pune
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
Exempted
District Implementation Unit - Pune, SMART Project
1 Jan 2025
28 Feb 2024
15 Mar 2024
28 Feb 2024
14 Mar 2024
28 Feb 2024
6 Mar 2024
Amount
PART – II -AIR COOLED REFRIGERATION SYSTEM - PRECOOLING ROOM (1-5), COLD ROOMS(1-5) & PACK HOUSE SCOPE OF WORK The work includes designing, engineering, providing, installing, testing and commissioning of the refrigeration and air conditioning system covering the equipment / materials / services convered in the Technical specification, BOQ and the drawings. The erection, testing and commissioning will include lifting of equipment placement and alignment in position, interconnecting piping, controls etc. The system shall be pressure tested and evacuated as per standard practice before charging the refrigerant gas. The plant shall be run on load for 3 days for satisfactory performance. All tools and tackles / welding machines, rods and gases etc. required for fabrication, erection, testing and commissioning etc. shall be arranged by the contractor at his own cost.
SUPPLY & INSTALLATION OF AIR COOLED CDU WITH AIRCOOLED CONDENSOR FOR PRE COOLING ROOMS , COLD STORAGE, PACK HOUSE
CDU:- • Delivered Cooling Capacity: 38 kw • Refrigerant: R407 C • Evap. Temp: 5* C • Cond. Temp: 55*C • COP: 2.68 • Ambient: 45 *c CDU Technical Details:• • Compressor Type Semi-Hermetic Reciprocating Compressor • Actual Capacity (KW) 38 kw • Comp. Power (KW). 15 kw • Condenser 4 Fan suitable for High ambient • Oil separator • Adequate receiver with sight-glasses, safety valve and service angle valve. • HP/LP • Filter Drier • Solenoid valve • Suction Accumulator • Pressure Gauge • Refrigeration controls Make DANFOSS / EMERSON /CASTEL • Structure material (Channel / Square section) M.S. With PU Painting / Coating
CDU:- • Delivered Cooling Capacity: 15 kw • Refrigerant: R407 C • Evap. Temp: 5* C • Cond. Temp: 53*C • Ambient: 43 *c. CDU Technical Details:• • Compressor Type Reciprocating Compressor Emerson Make Model No:-KHR571PQE-DX • Actual Capacity (KW) 15 kw • Comp. Power (KW). 6.5 kw • Condenser 2 Fan suitable for High ambient • Oil separator • Adequate receiver with sight-glasses, safety valve and service angle valve. • HP/LP • Filter Drier • Solenoid valve • Suction Accumulator • Pressure Gauge • Refrigeration controls Make DANFOSS / EMERSON /CASTEL • Structure material (Channel / Square section) M.S. With PU Painting / Coating
SUPPLY & INSTALLATION OF IDU MACHINERY FOR PRE COOLING ROOMS , COLD STORAGE, PACK HOUSE
Technical Details:- • Product Type : Ceiling Mounted Cooler • Model No : CF-48-64-SP • No. of Units :3 No’s • Design Duty :75 kw (2 Circuit) • Room Temp : 0/10 °C • Refrigerant : R407C evaporating @ -5/5°C ( DX System ) • Air Volume :80000 CMH • Fans :4 x 800 mm Dia Axial Fan, 1440 rpm; • Motor = 3.7 kW ( Each Fan) 415V/3ph./50Hz • Coil Data :4 FPI , Copper tubes With Plain Aluminum Fins. • Internal Volume: 126 dm³ • Defrost: Coil= NA , Tray= NA , Fan =NA • Outer Body: GI Powder Coated • Electrical Junction Box Should be of IP 45 Protection.
Technical Details:- • Product Type : Ceiling Mounted Cooler • No. of Units :20 No’s • Design Duty :17 kw • Room Temp :12 °C • Refrigerant : R407C evaporating @ 7°C ( DX System ) • Air Volume :19600 CMH • Fans :3 x 500 mm Dia Axial Fan, 1440 rpm; • Motor = 0.55 kW ( Each Fan) 415V/3ph./50Hz • Coil Data :4 FPI , Copper tubes With Plain Aluminum Fins. • Internal Volume: 25 dm³ • Defrost: Coil= NA , Tray= NA , Fan =NA • Outer Body: GI Powder Coated • Electrical Junction Box Should be of IP 45 Protection. Approved Makes: Carrier / Bluestar / Bluecold
SUPPLY & INSTALLATION OF ALLIED ACCESSORIES FOR PRE COOLING ROOMS , COLD STORAGE, PACK HOUSE
Supply of Liquid & Suction Refrigerant piping with Suction Line Rubber Nitrile Insulation connecting Indoor unit to Outdoor Unit For Medium Temperature Application. Refrigeration System as per Specifications suitable for site installation conditions with necessary supports / brackets , fittings & Clamps.
Supply of Electrical Cabling connecting Indoor unit to Outdoor Unit & control panel for Medium Temperature Application. Refrigeration System as per Specifications suitable for site installation conditions with necessary supports / brackets,fittings & Clamps.
Supply of PVC drain piping of 19 mm with Rubber Nitrile for avoiding water freezing inside pipe as per Specifications for Cold Rooms.
Supply of Epoxy Coated M S Base Frame for Installing Evaporator units in Precooler Rooms
Supply of Solid Cable Tray of 18 Gauge , Painted with RAL-9002 white, 400 mm Wide x 50 mm Collar Height with all necessary supports for Supporting & routing Refrigerated Copper Piping & Cables neatly as per Specifications.
Supply of Refrigerant R-407 C For Refrigerated Equipment.
Supply & Installation of TIC for Pre cooling, Cold Room , Process Hall.
Electrical control panel cubicle type, dust and vermin proof copper bus bars and suitable for 415 Volts, 3 phase, 50 C/s A.C. supply and incorporating the following: a) Incoming MCCB Rating as required. b) Earth leakage current ELR and suitable ELCB c) MCBs and starters for condensing units, air handling unit, ACUs in cold stores, ante room ARRANGEMENT SHOULD BE ENOUGH FOR HAVING RATED INCOMER MCB AND OUTGOING MCBS FOR 20 REF UNITS
M/S Virtus Techno
Eskimo Refrigeration Industries
Winchester Enterprises
Megastar Engineering
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .