Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Rejected-Technical | Rejected-Technical Documents not submitted |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
24 Apr 2025, 2:30 pmClosed
Executive Engineer, STD-II, Rajbagh,Srinagar
Office of the Executive Engineer, STD-II,RAJBAGH
Annual rate contract for Repairs and Maintenance of 33/11kv Receiving Stations Falling under the jurisdiction of Sub-Transmission Division-II, Rajbagh, Srinagar for the year 2025-26 or till next rate contract.
2025_PDD_274558_1
eNIT No STD-II / 01 of 2025-26 Dated 18-03-2025
Open Tender
Electrical and Maintenance Works
Item Rate
1 days
Rajbagh
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Executive Engineer, STD-II, Rajbagh,Srinagar
₹30,000
8 May 2025
19 Mar 2025
25 Apr 2025
22 Mar 2025
24 Apr 2025
22 Mar 2025
Amount
Disconnecting of damaged11KV VCB Panel/ 33KV C&R Panel/33KV VCB / MOCB from Circuit including dismantling of its accessories complete job (Including shifting of power cables/control cables as and when required as per site requirement and then relaying of same back to its original postion, loading,transportation and unloading at the divisional store)
Supply,Installation,testing and commissioning of 11KV VCB compatible with existing 11KV VCB Panel.
Supply,Installation,testing and commissioning of 33KV VCB compatible with existing 33KV VCB Panel.
Installation,testing and commissioning of 33KV VCB compatible with existing 33KV VCB Panel.
Installation,testing and commissioning of 11KV VCB Panel complete (material to be provided by the department)
Installation,testing and commissioning of 33KV C&R Panel complete (material to be provided by the department)
Installation,testing and commissioning of 33KV VCB complete (material to be provided by the department)
Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of make already installed at Receiving Stations
Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of make already installed at Receiving Stations
Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of make already installed at Receiving Stations
Installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of make already installed at Receiving Stations
Providing and fixing of Breaker contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of make already installed at Receiving Stations
Supply,installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of make already installed at Receiving Stations
Installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of make already installed at Receiving Stations
Supply,installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of make already installed at Receiving Stations
Installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of make already installed at Receiving Stations
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of for 11KV VCB panels of make already installed at Receiving Stations
Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of make already installed at Receiving Stations
Supply, Installation,testing and commissioning of 33KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 33KV Vacuum Interruptor of same composition,type,make already installed at Receiving Stations
Installation,testing and commissioning of 33KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 33KV Vacuum Interruptor of same composition,type,make already installed at Receiving Stations
Providing & fixing of damaged clamps (A.A) confirming to IS:617 standards (for 33KV VCB,33KV L.A, 33KV Isolator) with fresh one complete.
Providing & fixing of GI Channel Iron/Angle Iron/Nuts and Bolts/Clamps etc.
Fixing of damaged clamps (A.A) confirming to IS:617 standards (for 33KV VCB,33KV L.A,33KV Isolator) with fresh one complete.
Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of make already installed at Receiving Stations
Installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of make already installed at Receiving Stations
Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of make already installed at Receiving Stations
Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of make already installed at Receiving Stations
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of make already installed at Receiving Stations
Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of make already installed at Receiving Stations
Providing and fixing of clamps (Bi-Metallic) confirming to IS: 1285 standards ( for 33KV P.T Clamps,C.T clamps,Transformer Clamps(Both H.V & L.V Side),Pad Clamps)
Fixing of clamps (Bi-Metallic) confirming to IS: 1285 standards ( for 33KV P.T Clamps,C.T clamps,Transformer Clamps(Both H.V & L.V Side),Pad Clamps)
Providing and fixing of 33KV Post Insulators by way of replacement of damaged one confirming to IEC 61109/92-93 with latest amendments (porceline type)
Fixing of 33KV Post Insulators by way of replacement of damaged one confirming to IEC 61109/92-93 with latest amendments (porceline type)
Providing and fixing of 33K VCB Bushes complete assembly by way of replacement of damaged one confirming to IS:2099 standard (porceline type)
Fixing of 33K VCB Bushes complete assembly by way of replacement of damaged one confirming to IS:2099 standard (porceline type)
Providing and fixing of 33KV HV Bushes of power transformers complete assembly by way of replacement of damaged one confirming to IS:2099 standards (porceline type)
Fixing of 33KV HV Bushes of power transformers complete assembly by way of replacement of damaged one confirming to IS:2099 standards (porceline type)
Providing and fixing of 11KV LV Bushes of transformers complete assembly by way of replacement of damaged one confirming to IS: 2099 standards (porceline type)
Providing and fixing of Rubber O Ring(Kidney washer) for 11KV/33KV Bushings
Fixing of 11KV LV Bushes of transformers complete assembly by way of replacement of damaged one confirming to IS: 2099 standards (porceline type)
Supply,installation,testing and commissioning of 33KV C.T(3-core) confirming to IEC:185 and IS:2705 (part-1 to 4) standards of ratio 400-200/5-5-5A/ 250-125/5-5-5A) outdoor type
Fixing,installation,testing and commissioning of fresh 33KV CT (3-core) of different ratio confirming to IEC:185 and IS:2705 (part-1 to 4) standards by way of replacement of damaged one (material to be provided by the department) outdoor type
Supply, installation,testing and commissioning of 33KV P.T of (110V/√3) confirming to IS:3156 (part-I to Part-III) outdoor type
Fixing,installation,testing and commissioning of fresh 33KV PT (110V/√3) confirming to IEC:185 and IS:2705 (part-1 to 4) standards by way of replacement of damaged one (material to be supplied by the department) outdoor type
Providing and fixing of 33KV isolator 800 Amps heavy duty confirming to IS:9921 / IEC-62271-102 standards with earthing blade
Providing and fixing of 33KV isolator 800 Amps heavy duty confirming to IS:9921 / IEC-62271-102 standards without earthing blade
Fixing,installation,testing and commissioning of fresh 33KV isolators 800 Amps heavy duty confirming to IS:9921 / IEC-62271-102 standards (material to be supplied by the department) (with earthing blade / without earthing blade)
Providing,Installation,Testing and commissioning of 11KV G.O Set 600 Amps (with earthing blade) heavy duty conforming to latest version of IS - 9921 (part-I to V) with earthing blade by way of replacement of damaged one
Installation,Testing and commissioning of 11KV G.O Set 800 Amps heavy duty conforming to latest version of IS - 9921 (part-I to V) (material to be supplied by the department)
Providing,Installation,Testing and commissioning of 33KV G.O Set 600 Amps (with earthing blade) heavy duty conforming to latest version of IS - 9921 (part-I to V) with earthing blade by way of replacement of damaged one
Providing, fixing, installation, testing and commissioning of 11KV Isolators,630amps. conforming to IS 9921/IEC-129 standards with earthing blade
Providing, fixing, installation, testing and commissioning of 11KV Isolators,630amps. conforming to IS 9921/IEC-129 standards without earthing blade
Installation,Testing and commissioning of 11KV Isolators,630amps. conforming to IS 9921/IEC-129 standards (with earthing blade/without earthing blade ) (material to be supplied by the department)
Dismentalling of damaged/ under size cables of sorts including transportation upto stores
Providing and fixing of 33KV Drop out set with porcelaine insulator by way of replacement of damaged one as per latest IS standard with latest amendments therof.
Installation,Testing and commissioning of 33KV D.O. set by way of replacement of damaged one as per latest IS standard with latest amendments therof.(material to be supplied by the department)
Providing, Installation,Testing and commissioning of 33KV L.A. set (porcelaine type with clamps) by way of replacement of damaged one as per latest IS standard with latest amendments therof.
Installation,Testing and commissioning of 33KV L.A. set by way of replacement of damaged one as per latest IS standard with latest amendments therof. (material to be supplied by the department)
Oil Toping in 33/11 KV Power Transfromers and 33KV MOCB's (Transformer oil to be supplied by the department and to be lifted from Divisiona stores Karannagar)
Providing,installation, testing and commissioning of Winding Temperature meter by way of replacement of damaged one suitable for 33/11 KV, 10MVA/6.3MVA/5.0MVA/1.6MVA Power Transformers
Installation, testing and commissioning of Winding Temperature meter by way of replacement of damaged one suitable for 33/11 KV, 10MVA/6.3MVA/5.0MVA/1.6MVA Power Transformers
Providing,installation, testing and commissioning of Oil Temperature meter by way of replacement of damaged one suitable for 33/11 KV , 10MVA/6.3MVA/5.0MVA/1.6MVA Power Transformers
Installation, testing and commissioning of Oil Temperature meter by way of replacement of damaged one suitable for 33/11 KV , 10MVA/6.3MVA/5.0MVA/1.6MVA Power Transformers
Providing and fixing of Bush Rods suitable for 33/11KV Power Transformer (10MVA/6.3MA/5.0MVA/1.6MVA) by way of replacement of damaged one 33KV side
Fixing of Bush Rods suitable for 33/11KV Power Transformer (10MVA/6.3MA/5.0MVA/1.6MVA) by way of replacement of damaged one 33KV side
Providing and fixing of Bush Rods suitable for 33/11KV Power Transformer (10MVA/6.3MA/5.0MVA/1.6MVA) by way of replacement of damaged one 11KV side
Fixing of Bush Rods suitable for 33/11KV Power Transformer (10MVA/6.3MA/5.0MVA/1.6MVA) by way of replacement of damaged one 11KV side
Supply ,installation,testing and commissioning of 30V,100 AH Maintenance free Battery Bank ( comprising of 15 number batteries of 2volt each) complete with rack ,connectors etc conforming to IEC60896-21/22 standards of Exide/HBL/Luminous/AMAR Raja or equivalent make
Installation,testing and commissioning of 30V,100 AH Maintenance free Battery Bank ( comprising of 15 number batteries of 2volt each) complete with rack ,connectors etc conforming to IEC60896-21/22 standards of Exide/HBL/Luminous/AMAR Raja or equivalent make
Supply,installation,testing and commissioning of automatic 36V,DC,15amp. (constant current constant voltage ) fully automatic battery charger float cum boost type 2KVA
Installation,testing and commissioning of automatic 36V,DC,15amp. (constant current constant voltage ) fully automatic battery charger float cum boost type 2KVA
Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,Xlpe FRLSH Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable (including its transportation to divisional Stores) of 11KV switchgear (havells or Glastor or finolex or KEI make) of size
630mm^² 3-core,
400mm^² 3-core
300mm^² 3-core,
240mm^² 3-core
185mm^² 3-core,
150mm^² 3-core
120mm^² 3-core
Laying,Testing,commissioning of 11KV (E) grade armoured ,Xlpe FRLSH Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable (including its transportation to divisional Stores) of 11KV switchgear (havells or Glastor or finolex make) of size
630mm^² 3-core,
400mm^² 3-core
300mm^² 3-core,
240mm^² 3-core
185mm^² 3-core,
150mm^² 3-core
120mm^² 3-core
Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,Xlpe FRLSH Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable (including its transportation to divisional Stores) of 11KV switchgear (havells or Glastor or finolex or KEI make)
630mm^² 1-core
400mm^² 1-core
300mm^² 1-core,
240mm^² 1-core
185mm^² 1-core,
150mm^² 1-core
120mm^² 1-core
laying,Testing,commissioning of 11KV (E) grade armoured ,Xlpe FRLSH Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable (including its transportation to divisional Stores) of 11KV switchgear (havells or Glastor or finolex make)
630mm^² 1-core
400mm^² 1-core
300mm^² 1-core,
240mm^² 1-core
185mm^² 1-core,
150mm^² 1-core
120mm^² 1-core
Supply,laying,Testing,commissioning of 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLSH conforming to IS:1554(Part 1),IS 8130,IS ;5831 (Havells or Gloster or finolex make )
Laying,Testing,commissioning of 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLSH conforming to IS:1554(Part 1),IS 8130,IS ;5831 (Havells or Gloster or finolex make )
Supply,installation,testing,commissioning of 11KV ,3 core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make) by way of replacing damaged staight through jointing kit including its transportation to divisional stores.
630mm^² 3-core,
400mm^² 3-core
300mm^² 3-core,
240mm^² 3-core
185mm^² 3-core,
150mm^² 3-core
120mm^² 3-core
Installation,testing,commissioning of 11KV ,3 core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make) by way of replacing damaged staight through jointing kit including its transportation to divisional stores.
630mm^² 3-core,
400mm^² 3-core
300mm^² 3-core,
240mm^² 3-core
185mm^² 3-core,
150mm^² 3-core
120mm^² 3-core
Supply, Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Vikchem or Raychem suitable for Xlpe Power Cable by way of replacing damaged Cable kit including its transportation to divisional stores.
630mm^² 3-core,
400mm^² 3-core
300mm^² 3-core,
240mm^² 3-core
185mm^² 3-core,
150mm^² 3-core
120mm^² 3-core
Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Vikchem or Raychem suitable for Xlpe Power Cable by way of replacing damaged Cable kit including its transportation to divisional stores.
630mm^² 3-core,
400mm^² 3-core
300mm^² 3-core,
240mm^² 3-core
185mm^² 3-core,
150mm^² 3-core
120mm^² 3-core
Supply,installation,testing,commissioning of 11KV , 1core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or Vikchem or Raychem make) by way of replacing damaged staight through jointing kit including its transportation to divisional stores.
630mm^² 1-core
400mm^² 1-core
300mm^² 1-core,
240mm^² 1-core
185mm^² 1-core,
150mm^² 1-core
120mm^² 1-core
Installation,testing,commissioning of 11KV , 1core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or Vikchem or Raychem make) by way of replacing damaged staight through jointing kit including its transportation to divisional stores.
630mm^² 1-core
400mm^² 1-core
300mm^² 1-core,
240mm^² 1-core
185mm^² 1-core,
150mm^² 1-core
120mm^² 1-core
Supply, Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Vikchem or Raychem suitable for Xlpe Power Cable by way of replacing damaged cable termination kits including its transportation to divisional stores.
630mm^² 1-core
400mm^² 1-core
300mm^² 1-core,
240mm^² 1-core
185mm^² 1-core,
150mm^² 1-core
120mm^² 1-core
Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Vikchem or Raychem suitable for Xlpe Power Cable by way of replacing damaged cable termination kits including its transportation to divisional stores.
630mm^² 1-core
400mm^² 1-core
300mm^² 1-core,
240mm^² 1-core
185mm^² 1-core,
150mm^² 1-core
120mm^² 1-core
Disconnecting of Power Transformer from Circuit including dismantling of its accessories complete job (Including shifting of power cables/control cables as and when required as per site requirement and then relaying of same back to its original postion).
Loading of Power Transformer to the sub station bed / platform i/c manual dragging, rotation etc (if any required) (Complete Job)
Lifting of 100/63KVA auxillary Transformer from Transformer bed and loading it on platform truck/crane (including opening of HT/LT connections) complete job (the job includes manual dragging/rotation if required)
Unloading of Power Transformer from the platform truck to receiving station bed i/c manual dragging, rotation etc (if any required) (Complete Job)
Carriage of Power Transformer upto 5km
Carriage of Power Transformer beyond 5km upto 10km
Carriage of Power Transformer beyond 10km upto 20km
Carriage of Power Transformer beyond 20km
Installation, testing & commissioning of Power Transformer ( including assembly viz fixing of bushes, radiators, fans (if any), thermometer, wiring of instruments etc. ) Complete Job (Including shifting of power cables/control cables as and when required as per site requirement and then relaying of same back to its original postion)
Unloading of 100/63 KVA auxillary Transformer from platform truck/crane to Transformer bed including Installation, testing & commissioning of 100/63 KVA Auxillary Transformer, fixing of HT/LT connections, the job includes manual dragging/rotation (if required)( Complete job)
Manual Carriage of materials like 33KV CT / 33KV PT 33KV C&R panel , 33KV VCB panel , 11KV VCB panel etc upto first 150mtr lead
33KV C&R Panel
33kv VCB Panel
11KV VCB Panel
Manual Carriage of materials like 33KV CT / 33KV PT 33KV C&R panel , 33KV VCB panel , 11KV VCB panel For every additional 50mtr or part there off
33KV C&R Panel
33kv VCB Panel
11KV VCB Panel
Unloading of bulky material which are to be handled with care like 33KV C&R panel , 33KV VCB panel , 11KV VCB panel etc including manual carriage from dumping site upto proper stacking
33KV C&R Panel
33kv VCB Panel
11KV VCB Panel
Loading of bulky material which are to be handled with care like 33KV CT/PT,33KV C&R panel , 33KV VCB panel , 11KV VCB panel etc including manual carriage stacking site upto loading
33KV C&R Panel
33kv VCB Panel
11KV VCB Panel
Repairing of Re-Setting Links of 11 KV VCB Panel
Repairing of operating shaft of 11 KV VCB Panel
Repairing of Shower Contact of 11 KV VCB Panel
Repairing of Isolating Sockets of 11 KV VCB Panel
Repairing of High Tension Spring of 11 KV VCB Panel
Repairing of Tripping Shaft of 11 KV VCB Panel
Repairing of Rollers of 11 KV VCB Panel
Repairing of Latch Assembly of 11 KV VCB Panel
Repairing of Gear Assembly of 11 KV VCB Panel
Repairing of Tripping Mechanism of 11 KV VCB Panel
Repairing of Spring Charge Motor Assembly of 11 KV VCB Panel
Supply, Installation,Testing and commissioning of Re-Setting Links of 11 KV VCB Panel
Supply, Installation,Testing and commissioning of operating shaft of 11 KV VCB Panel
Supply, Installation,Testing and commissioning of Shower Contact of 11 KV VCB Panel by a fresh One
Supply, Installation,Testing and commissioning of Isolating Sockets of 11 KV VCB Panel
Supply, Installation,Testing and commissioning of High Tension Spring of 11 KV VCB Panel
Supply, Installation,Testing and commissioning of Tripping Shaft of 11 KV VCB Panel
Supply, Installation,Testing and commissioning of Rollers of 11 KV VCB Panel
Replacement of Latch Assembly of 11 KV VCB Panel
Supply, Installation,Testing and commissioning of Gear Assembly of 11 KV VCB Panel
Replacement of Tripping Mechanism of 11 KV VCB Panel
Supply, Installation,Testing and commissioning of Spring Charge Motor Assembly of 11 KV VCB Panel
Supply, Installation,Testing and commissioning of Triping Mechanism Complete suitable for of 11 KV VCB Panel of make already installed at Receiving Station
Deco Spray Painting
Supply, Installation, Testing and Commissioning of 11 KV Panel equipments/items by way of replacement of damaged one-
Voltmeter 11KV/110V
Ammeter
LED panel Indicators
Push Button
HRC fuse with Base -16 Amps
Installation, Testing and Commissioning of 11 KV Panel equipments/items by way of replacement of damaged one- Voltmeter 11KV/110V
Voltmeter 11KV/110V
Ammeter
LED panel Indicators
Push Button
HRC fuse with Base -16 Amps
Panel Control re-wiring with 2.5 sqmm flexible wire, connecting ribs, bunching wire, ferruling, thimbling etc
Supply,installation,testing and commissioning of Auxilary Relay -30 A by way of Replacement of Damaged/Burnt of type,make and class already installed in panel.
Installation,testing and commissioning of Auxilary Relay -30 A by way of Replacement of Damaged/Burnt of type,make and class already installed in panel.
Supply,installation,testing and commissioning of Auxilary Switch by way of Replacement of Damaged/Burnt of type,make and class already installed in panel.
Installation,testing and commissioning of Auxilary Switch by way of Replacement of Damaged/Burnt of type,make and class already installed in panel.
Supply,installation,testing and commissioning of TNC Switch by way of Replacement of Damaged/Burnt of type,make and class already installed in panel.
Installation,testing and commissioning of TNC Switch by way of Replacement of Damaged/Burnt of type,make and class already installed in panel.
Supply,installation,testing and commissioning of Trip Circuit Supervision Relay by way of Replacement of Damaged/Burnt of type,make and class already installed in panel.
Supply,installation,testing and commissioning of Buxhholz Relay by way of Replacement of Damaged/Burnt of type,make and class already installed in panel.
Installation,testing and commissioning of Trip Circuit Supervision Relay by way of Replacement of Damaged/Burnt of type,make and class already installed in panel.
Supply,installation,testing and commissioning of Numerical/Digital Relay by way of Replacement of Damaged/Burnt of same ratio(A.C &D.C),type,make and class already installed in panel.All relays shall conform to the requirements of IS:3231/IEC-60255 and IEC-61850 of (MIT113 ER / Ashida 141A) Operating Voltage 30-36Volts
Supply,installation,testing and commissioning of Numerical/Digital Relay by way of Replacement of Damaged/Burnt of same ratio(A.C &D.C),type,make and class already installed in panel.All relays shall conform to the requirements of IS:3231/IEC-60255 and IEC-61850 of (MIT113 ER / Ashida 141A) Operating Voltage 30-36Volts
Supply,Installation,Testing and Commissioning of Scada Compatible Digital Relay by way of Replacement of Damaged/Burnt of same ratio(A.C &D.C) already installed in panel (REF615 & RET620 ABB Make). All relays shall conform to the requirements of IS:3231/IEC-60255 and IEC-61850 of (MIT113 ER / Ashida 141A) Operating Voltage 30-36Volts
Fixing , testing and commissioning of Numerical/Digital Relay (MIT113 / Ashida 141A)/ SCADA Compatible Relay by way of Replacement of Damaged/Burnt of same ratio(A.C &D.C),type,make and class already installed in 11KV VCB panel.(material to be provieded by the department)
Providing and fixing of Arcing interrupting chambers suitable for 33 KV VCB panels of different makes by way of replacement of damaged one
Fixing of Arcing interrupting chambers suitable for 33 KV VCB panels of different makes by way of replacement of damaged one
Supply,installation,testing and commissioning of master trip relay 24-50 V by way of Replacement of Damaged/Burnt of ,type,make and class already installed in 11KV VCB panel
Installation,testing and commissioning of master trip relay 24-50 V by way of Replacement of Damaged/Burnt of same type,make and class already installed in 11KV VCB panel
Supply,installation,testing and commissioning of High Mast Yard lights (150W LED) by way of Replacement of Damaged/Burnt of type already installed
Installation,testing and commissioning of High Mast Yard lights (150W LED) by way of Replacement of Damaged/Burnt of type already installed
Filtration of Power Transformer Oil at site.
Plumbing work, repairing, fitting pipes, joints, repairing of geasers etc (LS) (1 job /Receiving Stn)
Oil Leakage arresting of Power transformer by way replacement of gaskets, tightening of all connections, use of sealing compound and other allied works
Providing and fixing of silica gel by way of replacement of old/wornout/ damaged one
Providing and laying of HDPE Pipe Outer Dia 180 mm Inner Dia 152 mm for laying of 11kV XLPE Cable from Power Transformer to Control Room
Providing and laying of Earthing Mat (GI Flat 50 mm x8 mm)
Providing and fixing of Earthing Electrode ( 3m long 40mm dia GI pipe) through GI Strip 50x6mm)
Providing and laying of 33 kV Yard Concreting and Metalling
Providing & replacement of old/damaged glazed shutters ( 44 mm thick ) for windows & clear storey windows using approved ( 4mm thick ) glass panes incl. a pair of imex hinges approved one fixed with necessary screws complete of 1st class deodar wood
Providing & replacement of old/damaged 44mm thick wire gauze shutters using galvanized M.S wire gauze average with of 1.4 mm strands with wire of dia 0.63 mm for doors , windows and clear storey windows incl a pair fixed by imex hinges with necessary screws complete of 1st class Deodar word.
Providing and fixing of hardware fittings of approved quality ISI make including fixing with necessary screws , nuts, bolts etc complete , ( approved ones )
Link Lock 11” long
Ornamental heavy handle 75 mm ( approved one ) aluminum base finished in required shade.
Magnetic catcher ( approved one )
Multi purpose locks of required size approved one ( Link ) or equivalent .
Providing & Painting with oil type wood preservative of approved brand and manufacture on old work (one or more coats)
Providing & Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade, one or more coats on old work.
Providing & Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on old work
Providing & Painting with aluminum paint of approved brand and manufacture to give an even shade, one or more coats on old work.
Providing & Distempering with 1st quality Acrylic/oil bound washable distemper (ready-made) having VOC content less than 50 grams/litre of approved manufacturer and of required shade and colour complete as per manufacturers’ specifications, one or more coats on old work
Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 meters lead with cement mortar 1:4 (1 cement : 4 coarse sand)
Renewing glass panes, with putty and nails wherever necessary including raking out old putty : Float glass panes of thickness 4.0 mm(weight not less than 10kg/sqm)
Renewing glass panes, with wooden fillets wherever necessary : Float glass panes of thickness 4.0 mm (weight not less than 10kg/sqm)
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand)
Clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared.
Providing and spraying of chemical treatment to the surface for grass/vegetables growth etc
Providing, Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening /binding material to fill up interstices of coarse aggregate, watering and compacting to the required density.
Providing and Spreading 6 mm thick red bajri, watering and rolling complete including preparation of the surface and rolling with road roller
Cleaning of cable trenches including removal of water from the trenches using motor
Construction of 750 mm Cable Trench by way of earth excavation in all sorts , providing and laying of lean pad in 1:4:8 mix with stone aggregate 20mm, cement concrete of M-15 1:2:4 mix with stone aggregate 20mm, 12mm Torr Steel for reinforcement, chequered plate (1m x0.8mx 5mm), angle iron (50x50x6mm), kota stone, and 15mm thick plaster including cost of form work and carriage of materials as well as disposal of excavated earth. (Complete Job)
Construction of 500 mm Cable Trench by way of earth excavation in all sorts , providing and laying of lean pad in 1:4:8 mix with stone aggregate 20mm, cement concrete of M-15 1:2:4 mix with stone aggregate 20mm, 12mm Torr Steel for reinforcement, chequered plate (1m x0.8mx 5mm), angle iron (50x50x6mm), kota stone, and 15mm thick plaster including cost of form work and carriage of materials as well as disposal of excavated earth. (Complete Job)
Flooring with cement concrete 1:2:4 mix incl. floating coat of neat cement 50 mm thick
Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) :
Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar
Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m. (stacks of cleaned bricks shall be measured) : From brick work in cement mortar
Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix)
Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/by mechanical means including stacking of pipes within 50 meters lead as per direction of Engineer-in-charge : 15 mm to 40 mm nominal bore.
Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead.
Providing and laying of Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. in colour such as White, Ivory, Grey, Fume Red Brown
Providing and laying of 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 coarse sand)
Providing and laying of 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 coarse sand)
Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work, over and including water thinnable priming coat to give an even shade
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.
Providing and fixing P.V.C low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete: 10 liter capacity -White
Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan.
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge.
Internal work-exposed on wall with clamps at 1.00 meter spacing
PN-16 pipe, 16mm OD(SDR-7.4)
PN-16 pipe , 20mm OD(SDR-7.4)
PN-16 pipe , 25mm OD(SDR-7.4)
PN-16 pipe , 32mm OD(SDR-7.4)
PN-16 pipe , 40mm OD(SDR-7.4)
PN-10 pipe , 50mm OD(SDR-11)
Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall/ Sueface etc.
PN-16 pipe, 16mm OD(SDR-7.4)
PN-16 pipe , 20mm OD(SDR-7.4)
PN-16 pipe , 25mm OD(SDR-7.4)
PN-16 pipe , 32mm OD(SDR-7.4)
External work including trenching, refilling etc.
PN-16 pipe, 16mm OD(SDR-7.4)
PN-16 pipe , 20mm OD(SDR-7.4)
PN-16 pipe , 25mm OD(SDR-7.4)
PN-16 pipe , 32mm OD(SDR-7.4)
PN-16 pipe , 40mm OD(SDR-7.4)
PN-10 pipe , 50mm OD(SDR-11)
PN-10 pipe , 63mm OD(SDR-11)
PN-10 pipe ,75mm OD(SDR-11)
PN-10 pipe , 90mm OD(SDR-11)
PN-10 pipe , 110mm OD(SDR-11)
PN-10 pipe , 160mm OD(SDR-11)
Providing and fixing PPR Unions
PPR Union 20mm
PPR Union 25mm
PPR Union 32mm
PPR Union 40mm
PPR Union 50mm
PPR Union 63mm
PPR Union 75mm
Random Rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with: Cement mortar 1:6 (1 Cement : 6 coarse sand)- Nallah
Random Rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with: Cement mortar 1:6 (1 Cement : 6 coarse sand)- Quarry
Providing and fixing of UPVC pipes (working pressure 4 kg / cm2 ) Rubber (Seal) Ring 110 mm dia
Providing and fixing of UPVC coupler for UPVC drainage pipes 110 mm
Providing and fixing of UPVC pusufit coupler (single) 110 mm thick
Providing and fixing of UPVC single equal Tee (without door) 110x110x110 mm
Providing and fixing of UPVC single equal Tee (with door) 110x110x110 mm
Providing and fixing of 110x110x110x110 mm UPVC double equal door Tee
Providing and fixing of 110x110x110 mm UPVC single equal Y with door
Providing and fixing of UPVC bend 87.5° 110 mm bend
Providing and fixing of 110 mm UPVC bend 450
Providing and fixing of 110 mm bend UPVC plain shoe
Providing and fixing of 110 mm bend UPVC pipe clip
Note: The material utilized/works executed shall be stritctly as per REC Standards with Latest amendments there off.
M/S ENGINEERS ASSOCIATES (BID ID -2360790)
M/s Intel Technocrates (BID ID -2360823)
Kashmir Engineering Aids (BID ID -2357112)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .