Dy. General Manager (Civil)
EMS Division, NHPC Office Complex, Sector- 33, FBD
SITC of Cooling towers, repair of cooling tower structure and replacement of valves installed in HVAC System at Neer Shakti Sadan Office Complex , NHPC Ltd., Sector-33, Faridabad.
2021_NHPC_634586_1
NH/ EMS015(23)/1/2021/37
Open Tender
Electrical Works
Works
90 days
NHPC Office Complex, Sector-33
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
NHPC LIMITED
Exempted
2 Nov 2021
21 Jun 2021
20 Jul 2021
21 Jun 2021
12 Jul 2021
21 Jun 2021
Amount
FRP Cooling tower 400 TR complete with Twin 3 phase, EEF-2 motor, PVC frills, Complete is all respect
MS Base frame for cooling tower, Hot Dip Galvanised (Combination of Chanel & Angles)
Dismantling of old cooling towers
Shifting of Scrap to Scarp yard inside NHPC Premises only.
Erection charges of cooling tower
Transportation charges (I/C UNLOADING/SHIFTING)
INSULATED VALVES
Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications
GEAR OPERATED INSULATED VALVES
Butterfly Valve (Wafer Type) S.G Iron Construction with SS -304 Disc, PN-16, Gear Operated , Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot eater circulation as specified
300 mm dia
250 mm dia
200 mm dia
BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified
125 mm dia
100mm dia.
50 mm dia
40 mm dia
SITC of bronge ball balve 20mm complete with accessories as required.
VALVES WITHOUT INSULATION
Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.
BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified
150 mm dia
Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS 'C' class along with necessary clamps, vibration isolators and fittings such as bends,tees etc.but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
200mm dia.
150mm dia.
100mm dia.
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required
50 mm dia
80 mm dia
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete.
On steel work
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.
M.S. tube
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for :Edges of slabs and breaks in floors and walls. Under 20 cm wide
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
NIRVANA TECHNOLOGIES
welcome engineers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .