| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.9 LAccepted-AOC GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹43.7 L+₹26,006 (0.60%)Rejected-Finance 15 BOH ROAD DEFENCE ENCLAVE AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance BEING L2 REJECTED | |
| 3 | L3₹44.3 L+₹81,157.50 (1.87%)Rejected-Finance MAYURESH BHARAT CHS PLOT NO 170 181 B 09 SECTOR 21 NERUL NAVI MUMBAI 400706 | THANE | MAHARASHTRA | 400706 | L3 | Rejected-Finance BEING L3 REJECTED | |
| 4 | L4₹44.6 L+₹1.1 L (2.47%)Rejected-Finance 00 KHATA NO 514 4357 PLOT NO 169 3484 KESHARA BHUBANESWAR KHURDA KHORDHA ODISHA 751007 | KHORDHA | ODISHA | 751007 | L4 | Rejected-Finance BEING L4 REJECTED | |
| 5 | L5₹44.8 L+₹1.3 L (3.02%)Rejected-Finance FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L5 | Rejected-Finance BEING L5 REJECTED |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
21 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
REPAIR REPLACEMENT OF HDPE TANKS CONCRETE TANKS AND LOFT TANKS INCLUDING CLEANING OF OVERHEAD SERVICE TANKS LOFT TANKS UNDER AGE BR II KARANJA AT NAVAL STATION KARANJA
2023_MES_625982_1
8759/E8
Open Tender
Civil Works
Item Rate
270 days
GE NW KARANJA
D and above a i
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹90,000
Yes
10 Jan 2024
31 Oct 2023
23 Nov 2023
31 Oct 2023
21 Nov 2023
14 Nov 2023
Amount
Notes : (i) The work consists of 02 jobs as under:- JOB (A) : TPP 23-24 Ser No. 40 (ii) Please refer schedule 'A' notes before quoting the tender. (iii) Amount of Schedule of Credit shall be deducted off line by the department.
Note:- The Unit Rate quoted in r/o Ser item No 1.02 to 1.76 are deemed to include for the following and nothing extra will be paid for these works: 1. Supplying, erecting and use of scaffolding upto required height (max 25 to 30m) or upto 8th floor height with necessary H-frames, pipes, couplers, buckles, bracing, top platform with support railing at top etc. at all levels of building including carriage of the materials to the location, erecting, fixing the scaffolding and dismembering the same after working and taking away the scaffolding materials etc. complete as per direction of Engineer-in-charge. 2. Supplying, erecting & use of temporary bamboo scaffolding around the building as required. The scaffolding is to be secured properly in position by bracings, ties clamps, etc. complete including providing and erecting working platform at all heights as required, including removal after completion of work all as per direction of Engineer-in-Charge.
Taking up or down 15mm bore of pipe steel tubing and connections, complete all as specified and directed.
Taking up or down 20mm bore of pipe steel tubing and connections, complete all as specified and directed.
Taking up or down 25mm bore of pipe steel tubing and connections, complete all as specified and directed.
Taking up or down 40 or 50mm bore of pipe steel tubing and connections, complete all as specified and directed.
S&F 15 mm bore GI tubing medium grade with all fittings and fixed to walls or laid in floors and incl concealed pipe lines complete all as specified and directed.
S&F 20 mm bore GI tubing medium grade with all fittings and fixed to walls or laid in floors and incl concealed pipe lines complete all as specified and directed.
S&F 20mm bore CPVC Pipes SDR 11 & Plain CPVC SDR 11 fittings on wall / celling or laying in floors complete all as specified and directed.
S&F 25 mm bore GI tubing medium grade with all fittings and fixed to walls or laid in floors and incl concealed pipe lines complete all as specified and directed.
S&F 25 mm bore CPVC Pipes SDR 11 & Plain CPVC SDR 11 fittings on wall / celling or laying in floors complete all as specified and directed.
S&F 50 mm bore GI tubing medium grade with all fittings and fixed to walls or laid in floors and incl concealed pipe lines complete all as specified and directed.
S&F in repairs 15mm bore stop or angle cock with flange cast copper alloy, chorminium plated, fancy type, screwed both ends for iron pipe or for union complete all as specified and directed
S&F in repairs 20mm bore stop valve cast copper alloy with handle screwed both ends for GI out let/inlet pipe or for union including threading to existing pipes on both ends complete all as specified and directed
S&F in repairs fancy type bib taps chromium plated 15 mm dia cast copper alloy with crutch or butter fly handle screwed down for iron pipe or for brass ferrule , complete all as specified & directed.
S&F in repairs Health faucet (ABS body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified & directed.
S & F in repairs 15mm bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. complete all as specified and directed.
S&F in repairs for 10 litre capacity PVC valveless syphonic action type flushing cistern high or low level (exclusive of brackets) white with inlet ball valve, float and handle inlcuidng brackets complete all as specified and directed.
S&F in repairs 15 mm dia PVC connection of length 450mm long complete all as specified and directed.
S&F fixed in repairs Wash hand basin vitreous china (flat back) size 550 x 400 mm including brackets waste brass chromium plated with long screwed shanks and fly nuts 32 mm size including 32mm dia PVC waste pipe complete all as specified and directed.
S&F in repairs vitreous china urinal, half stall type complete including providing and fixing plugs bedding urinal against wall in cement mortar in 1:2 securing urinals to plugs with and including 60 mm brass screws, pointing around urinal back in cement , flush pipes, 32mm dia PVC waste pipe, inlet ,outlet etc complete all as specified and directed.
S&F in repairs PVC waste pipe for 32mm bore pipe complete complete all as specified and directed.
S&F in repairs Gun-metal, globe or gate valves, 15mm bore, with iron wheel head, screwed both end for iron pipe complete all as specified and directed.
S&F in repairs Gun-metal, globe or gate valves, 20mm bore, with iron wheel head, screwed both end for iron pipe complete all as specified and directed.
S&F in repairs Gun-metal, globe or gate valves , 25mm bore, with iron wheel head, screwed both end for iron pipe complete all as specified and directed.
Disconnecting existing tanks, exc 250 and not exc 500 litres capacity, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and refixing in postion and cleaning and removing all as scales and dirt, etc from tank and from mouth of circulating pipes, etc complete and washing the tanks by using bleaching powder and clean water & including reconnecting & re-fixing the same in its original position included Note. a, b, c in this items complete all as specified and directed. Note :- (a) writing the date of cleaning on the outer surface of the tank by paint, letters of 3cm height and width including obliterating old writing all as specified and directed. (b) If tank cleaning time, any blockage of internal/external pipe line to be cleared and incl all necessary fittings. (c) Before tank cleaning inform to all Qtrs individuals. (d) Before the tank cleaning disconnect and refixing the same position.
All as per BOQ Serial item No 1.25 above , but capacity exc 500 and not exc 1000 litres complete all as specified and directed.
All as per BOQ Serial item No 1.25 above , but capacity exc 1000 and not exc 2000 litres complete all as specified and directed.
M&L for Petty repair to internal water/external inlet water GI pipe line any type including socket,elbow,nipple ,with repair to water blockage , pipe line leakage (arrest the leakage incl all fitting) including concealed water tubing etc at of any height using scaffolding etc complete all as specified & directed.
S&F in repairs 500 ltrs capacity rotatonal moulded polyethylene water storage tanks Triple layer in white colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including connecting the CP brass float valve of required size, PVC tank cover incl all fittings, 20mm bore GI medium grade overflow pipe, 40mm bore GI flush pipe with plug, 15mm bore GI vent pipe and RCC staging a shown on drawings. The length of overflow pipe shall be brought upto nearest sump/outlet of rain water spouts/holes and connect to inlet and outlet pipes, tank nipple, elbow, bend, union, sockets, etc complete all as specified & directed.
All as per BOQ Serial item No 1.29 above, but 1000 litres capapcity.
All as per BOQ Serial item No 1.29 above, but 2000 litres capapcity.
S&F in repairs Ball valves 15mm bore high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe & fixed. (minimum weight -142 gms) complete all as specified and directed.
S&F in repairs Ball valves 20mm bore high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe & fixed. (minimum weight -210 gms) complete all as specified and directed.
S & F in repairs Ball valves 25mm bore high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe & fixed. (minimum weight -210 gms) complete all as specified and directed.
S & F in repairs PVC covers of PVC/ HDPE water tank suitable for 500 capacity including all necessary fixing arrangement complete all as specified and directed.
All as per BOQ Serial item No 1.35 above, but 1000 litres capapcity.
All as per BOQ Serial item No 1.35 above, but 2000 litres capapcity.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed
S&F mild steel compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc built up from two or more bem or channel sections or angle with plates, including all lattice bars, stiffners, gusset plates conforming to Gde Fe-410-W (GdeE-250 quality A) for overhead tank staging complete all as specified and directed.
S&F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L cement concrete 1:2:4 tye B1 using 20mm graded stone aggregate in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any guage, thickness, complete all as specified and as directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of an colour having tenstile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified & directed
Demolition of pre-cast concrete block walling built in cement mortar including all quoined, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles all as directed. complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry with solid blocks in 10cm in width in type B1 (1:2:4) and setting in mortar (1:6) complete all as specified and as directed.
Demolition of Brick work or stone / boulder masonry built in cement mortar including all quoins, arches , pillars, etc. but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and as directed.
M&L for walling of random rubble or polygonal rubble walling, brought upto coursed well bonded, bedded and solidly hearted, built in cement mortar (1:4) Complete all as specified and as directed.
Taking down cement plaster on brick walls or stone walls etc including raking out joint, hacking for key, scrubbing down with water etc including removing debries directed for a distance max upto 500m complete all as specified & directed
M&L for rendering 15 mm thick on fair faces of brick/concrete surfaces cement plaster in CM (1:4) , with integral water proofing compound as per manufacturers instructions finished even and smooth without using extra cement, complete all as specfified and directed.
Preparation of new or previously untreated plastered surfaces of walls and M&L for applying two coats of acrylic antifungal paint exterior grade paint plain or camouflage pattern over & including one coat of primer complete all as specified and as directed
Supply only integral water proofing compound
Prepration of steel surfaces over 10 cm width or girth and M&L for applying two coats of synthetic enamel paint over & including one coat of zinc chromate primer all as specified.
Dismantling expanded metal,/welded wire fabrick Nexc 4 kg per sqm any thickness or mesh, fixed with steel or wood fillets, if any complete all as specified and as directed
S&F Welded steel wire fabric n exc 4 kg per Sqm fixed to wood or steel members complete all as specified and as directed
Demolition of cement concrete (reinforced )of any description and in any position not otherwise specifically provided for complete all as specified & directed.
M&L RCC 1:2:4 type B-1 using 20mm graded stone agg as in slab or shelve etc including necessary formwork
M&L TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clipscomplete all as specified and directed
Demolition of cement concrete in ground floor and paving not exceeding 15cm thick below or above ground level un re-inforced complete all as specified and directed. .
M&L PCC 1:4:8 type D2 using 40mm graded stone aggregate, 75 mm thick as in sub base of flooring complete all as specified and directed. .
M&L PCC 1:2:4 type B-1 using 20mm graded stone aggregate, 40mm thick as in flooring finished even and smooth with out using extra cement complete all as specified and directed. .
M&L PCC 1:2:4 type B2 using 40mm graded stone aggregate, 100mm thick as in flooring complete all as specified and directed. .
M&L for attending day to day complaint of plumbing,connections, bathroom, kitchen trap complete all as specified and as directed through complant slip as under :- Note:- (a) Complaint register/slip shall be provided at the time of claiming the payment. (b) Miniumum 01 person shall be present on all working days 0900 hrs to 1700 hrs to attend the above complaints/maintenance and reporting the progress to AGE B/R-II Sub Divn. (c) Contractor shall arrange suitable T&P (such as pipe wrench, plunger, hacksaw, spanners, pliers, cutter, thread seal, auger and suitable materials/ tools) GI wire, PHAWADA, bucket, spike etc incl necessary form work/ scaffolding and safety measure. (d) For non attending of sewage complaints within 24 hours recovery of Rs 300/- per complaint per day shall be deducted from his dues on this account and the report on non compliance of such complaints shall be enclosed with each RAR/Final bill. Note:- Rate quoted shall include for scaffolding to any height , ladder, covering etc, and all other safety equipments before start the work. complete all as specified and directed
M & L for 75 mm thick PCC 1:3:6, type C1 (using 20 mm graded agg) as in plinth protection and finishing the cement concrete surface even and smooth without using extra cement complete all as specified and directed.
Taking down eaves gutters and rainwater pipes( any size or pattern) , including all fittings, heads, shoes, bends , swan necks, etc, removal to store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed. .
S&F 150 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including bends complete all as specified and directed.
S&F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall. Complete all as specified and directed.
S&F 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
S&F for PVC (SWR) bends any radius 110mm bore complete all as specified and as directed
S&F for PVC (SWR) bends any radius 75mm bore complete all as specified and as directed
S&F in repairs 32 mm bore Brass chromium plated bottle traps for wash basins with inlet and out let screwed for pipe or connections including necesaary packing, union and cap and fixed complete all as specified and as directed.
Dismantling of stone slabs & tiles of any description or thickness in floor aprons, cills etc laid bedded & pointed in any mortar complete all as specified and directed.
M&L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-ciils, cooking platforms, and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite with & including 10 mm thick screed in CM (1:6) complete all as specifeid and directed.
M&L glossy chequered cement concrete tiles 300x300x25mm thick, set jointed and pointed in near cement slurry in floors with white cement and pigments in any colour machine preassed glazed , over & including cement screed bed 15mm thick in cement mortor 1:6 complete all as specified and directed. .
Supply and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm hickompacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed.
M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in kerbing all around tile complete all as specified and directed.
M&L for Non-skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over & including 15mm thick screed bed in CM (1:6) etc including disamantling of old tiles complete all as specified and directed.
Mahadev Enterprises
ECOBUILD
SAI ENTERPRISES
M.K Enterprises
OM ENTERPRISES
Pheonix Engineers & Contractors
K N CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .