Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹17.1 LAdmitted-Finance AT PO PS KHANDAPADA DIST NAYAGARH | -20.61% | ₹17.1 L | L1 | Admitted-Finance |
| 2 | L2₹17.9 LAdmitted-Finance | -16.52% | ₹17.9 L | L2 | Admitted-Finance |
| 3 | L3₹21.0 LAdmitted-Finance | -2.30% | ₹21.0 L | L3 | Admitted-Finance |
| 4 | L4₹21.3 LAdmitted-Finance | -1.05% | ₹21.3 L | L4 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹21,500
Closing Date
17 Feb 2026, 5:00 pmClosed
EXECUTIVE OFFICER
NAC Office, Odagaon, Nayagarh, Pin-752081
Installation of 63 KVA Sub Station at New Office Building NAC Odagaon New Jaringi Sahi.
2026_ORULB_125707_1
NAC-ODG-06/2025-26
Open Tender
Electrical Works
NAC ODAGAON
Please refer Tender documents.
2 documents required · 2 mandatory
₹7,080
₹21,500
Yes
18 Feb 2026
9 Feb 2026
18 Feb 2026
9 Feb 2026
17 Feb 2026
9 Feb 2026
9 Feb 2026 - 17 Feb 2026
WPB(GI) pole 160x152(11Mtr.Long,30.44KG/Mtr.) (Total pole weight with base plate & stiffner =334.84kg +10.74kg =345.58KG)
Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each channel length 1.2 mtr., 2 no's channel required =( 2x9.56x1.2)
Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 8 no's required = (8x2.36x0.280)
Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each channel length 0.306 mtr., 2 no's channel required =( 2x9.56x0.306)
Danger Plate, 1 no's.
Back Clamp for danger Plate 25X3 mm. flat(GI), 0.59Kg/Mtr. Flat GI of 0.510mtr length 1 no's = (1x0.59x0.510)
GI barbed wire anticlimbing device 3 Kg. Per support
Back Clamp for anticlimbing device 25X3 mm. flat GI, 0.59Kg/Mtr. Flat GI of 0.510mtr length 4 no's = (4x0.59x0.510)
11 KV pin insulator polymer
H W fitting(B&S) 70KN, 3Bolt
Disc insulator (B&S) 70 KN polymer
Earthing of Support ( Coil Type )
No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing
NON METALIC TIES -11KV 55SQ.MM CVRD AAAC
IPC of 55sq.mm AAAC (For covered conductor)- 11KV
Spike GI (Using 50x6mm flat GI welded with 8mm square bar)2nos. Of spike per set in each pole
GI Nut , Bolt & Washer of different sizes (3.55 Kg each Cut Pole)
GI Nut , Bolt & Washer of different sizes (3.55 Kg each Cut Pole)
Yellow Paint (GIS Numbering & Zebra stripping for background)
Stock, Storage & Insurance i.e 3% of A
Contigency @ 3% of C
Tools & Plants @ 2% of C
Transportation @ 7.5% of C
Erection Charges @ 5% of C (except Trf/Breaker/WPB/ H-Pole/HT stay set/PSC pole)
Erection Charges @ 10% of C (except Trf/Breaker/WPB/ H-Pole/HT stay set/PSC pole)
Civil & Services
Concreting ratio 1:1.5:3 (500mmX500mmX1800mm) = 0.45Cu.mtr per pole
Couping ratio 1:1.5:3 with dimension ( 500X500X450)= 0.1125 Cu mtr per pole
WPB(GI) pole 160x152(11Mtr.Long,30.44KG/Mtr.) (Total pole weight with base plate & stiffner =334.84kg +10.74kg =345.58KG)
Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each channel length 1.2 mtr., 2 no's channel required =( 2x9.56x1.2)
Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 8 no's required = (8x2.36x0.280)
Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each channel length 0.306 mtr., 2 no's channel required =( 2x9.56x0.306)
Danger Plate, 1 no's.
Bank Clamp for danger plate 25X3 MM flat GI 0.59 Kg per Mtr flat GI of 0.510 Mtr. Length
GI barbed wire anticlaimbing device 3 Kg per Support
Bank Clamp for anticlimbing 25X3 MM flat GI 0.59 Kg per Mtr flat GI of 0.510 Mtr. Length
11 KV pin insulator polymer
H W fitting(B&S) 70KN, 3Bolt
Disc insulator (B&S) 70 KN polymer
Earthing of Support ( Coil Type )
No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing
NON METALIC TIES -11KV 55SQ.MM CVRD AAAC
IPC of 55sq.mm AAAC (For covered conductor )-11KV
SpikE GI (Using 50x6mm flat GI welded with 8mm square bar)2nos. Of spike per set in each pole
HT Stay Clamp 50x8 mm flat GI 3.14 Kg per Mtr. 0.551 Mtr Length 2 Nos. of required
HT Stay set complete
HT Stay Insulator Type C
7/10 SWG stay wire 15 per stay
GI Nut , Bolt & Washer of different sizes (3.55 Kg each Cut Pole)
Black Paint (GIS Numbering & Zebra stripping)
Yellow Paint (GIS Numbering & Zebra stripping for background)
Stock, Storage & Insurance i.e 3% of A
Contigency @ 3% of C
Tools & Plants @ 2% of C
Transportation @ 7.5% of C
Erection Charges @ 5% of C (except Trf/Breaker/WPB/ H-Pole/HT stay set/PSC pole)
Erection Charges @ 10% of C (except Trf/Breaker/WPB/ H-Pole/HT stay set/PSC pole)
Fixing of 11KV Line complete stay set bincludes 1)Turn buckle assembly2)Stay rod& Stay plate3)Stay Insulator 4)Stay wire 5) Stay clamps with nuts & bolts BA will do the excavation including excation ,supply of .5Cum cement concrete foundation 1:2:4 size 500mmx500mmx800mm using 20mm BHG metal with all labopur and material as per TPCODL Drawing and standard
Concreting ratio 1:1.5:3 (500mmX500mmX1800mm) = 0.45Cu.mtr per pole
Couping ratio 1:1.5:3 M-20 with dimension ( 500X500X450)= 0.1125 Cu mtr per pole
PSC POLE 10 MTR. LONG 330KG
PSC Clamp(GI)
Straight cross arm 100x50x6xmm 9.56kg/mtr each channel (GI) LENTH 1.2MTR. 4NOS CHANNEL required =(4x956x1.2)
Fish Plate GI 50x6mm 2.36kg/mtr. Each .280 mtr lenth 16nos required=(16x2.36x0.280)
Straight cross arm 100x50x6mm 9.56kg/mtr. Each channel GI lenth 0.306mtr. 4nos. Channel GI required =4x9.56x0.306
Danger plate 1nos.
Back clamp for danger plate 25x3mm flate GI of .510mtr. Lenth 1nos=(1x.59x.510)
GI barbed wire anticlimbing device 3kg per support
Back clamp for anticlimbing device 25x3mm flate GI .59KG/MTR flate GI .59KG/MTR flate GI of .510mtr. Lenth 4nos. =(4x.59x.510)
11kv pin insulator polymer
HW fitting B&S 70KN Polymer
Disc insulator B&S 70KN Polymer
Earthing support coil type
No-8 GI wire dia 4.6mm .131 kg/mtr 2mtr for connecting pole with coil earthing
NON METALIC TIES -11KV 55SQ.MM CVRD AAAC
IPC of 55sq,mm AAA conductor for covered conductor 11kv
Spike GI using 50x6mm flate GI welded with 8mm square bar 2nos of spike per set in each pole
HT stay clamp 50x6mm flate GI 3.14kg/mtr. .551mtr. Lenth 2nos. Qty required 1pair
HT Stay set
HT Stay Insulator type-C
7/10 SWG stsy wire 15kg/stay
GI nut bolt & washer different size
Black Paint Numbering & Zebra striping
Yellow colour painting GIS Numbering & Zebra stripping for Background
Stock, Storage & Insurance i.e 3% of A
Contigency @ 3% of C
Tools & Plants @ 2% of C
Transportation @ 7.5% of C
Erection Charges @ 10% of C (except Trf/Breaker/WPB/ H-Pole/HT stay set/PSC pole)
Erection Charges @ 20% of C (except Trf/Breaker/WPB/ H-Pole/HT stay set/PSC pole)
Fixing of 11KV Line complete stay set bincludes 1)Turn buckle assembly2)Stay rod& Stay plate3)Stay Insulator 4)Stay wire 5) Stay clamps with nuts & bolts BA will do the excavation including excation ,supply of .5Cum cement concrete foundation 1:2:4 size 500mmx500mmx800mm using 20mm BHG metal with all labour and material as per TPCODL Drawing and standard
Couping ratio 1:1.5:3 M-20 Grade with dimension ( 500X500X1667)= 0.42 Cu mtr per pole
PSC POLE 10 MTR. LONG 330KG
PSC Clamp(GI)
11KV V cross arm GI
Top bracket 100x506mm GI Channel 2kg each
Danger Plate, 1 no's.for each pole
Back clamp for danger plate 25x3mm flate GI of .510mtr. Lenth 1nos=(1x.59x.510)
GI barbed wire anticlimbing device 3kg per support
Back clamp for anticlimbing device 25x3mm flate GI .59KG/MTR flate GI .59KG/MTR flate GI of .510mtr. Lenth 4nos. =(4x.59x.510)
11kv pin insulator polymer 3OS.REQUIREDFOR EACH SUPPORT
Earthing support coil type
No-8 GI wire dia 4.6mm .131 kg/mtr 2mtr for connecting pole with coil earthing
GI nut bolt & washer different size
55sq.mm XLPE Insulated AAA Conductor
Black Paint Numbering & Zebra striping
Yellow colour painting GIS Numbering & Zebra stripping for Background
NON METALIC TIES -11KV 55SQ.MM CVRD AAAC
SpikE GI (Using 50x6mm flat GI welded with 8mm square bar)2nos. Of spike per set in each pole
Stock, Storage & Insurance i.e 3% of A
Contigency @ 3% of C
Tools & Plants @ 2% of C
Transportation @ 7.5% of C
Erection Charges @ 10% of C (except Trf/Breaker/WPB/ H-Pole/HT stay set/PSC pole)
Erection Charges @ 20% of C (except Trf/Breaker/WPB/ H-Pole/HT stay set/PSC pole)
Concreting ratio 1:1.5:3 M20 Grade 500mmX1667mm=0.42 Cu Mtr. Per pole
Guarding Channel GI 75X40X5.8mm 7.14kg/mtr. Each channel GI Lenth2.2mtr. 4nos channel GI required=(4x47.14x2.2) for single pole
No-6 GI wire .192kg/mtr. For main string
No-8 GI wire .131kg/mtr. For lacing
Eye bolt 236mm ,16mm dia 1.577kg/mtr.
GI Pipe earthing 40mm 3mtr. Long
50X6MM Flate GI for earthing 2.36kg/mtr. 10.7mtr. For each raising =10.7x2.36
Stock, Storage & Insurance i.e 3% of A
Contigency @ 3% of C
Tools & Plants @ 2% of C
Transportation @ 7.5% of C
Erection Charges @ 10% of C (except Trf/Breaker/WPB/ H-Pole/HT stay set/PSC pole)
Construction of earthing chamber including installation of earthing pipe. Making earthing chamber including excavation soil treatment with bentonide powdwer calculation of earth resisrance ,including installation of 3Mtr. GI pipe 40mm/50mm including welding of flat GI around pipe
PSC POLE 10 MTR. LONG 330KG
PSC Clamp(GI)
Top Channel GI 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3000x9.56= 57.36 Kg)
Fish Plate GI 50x6mm 2.36kg/mtr. Each .280 mtr lenth 16nos required=(16x2.36x0.280)
AB Switch Mounting Channel 75x40x4.8 mm GI Channel (3000mm long )7.14kg/mtr. 2 nos(each 2x3.00x7.14=42.84kg)
AB switch side support channel 75x40x6mm 9.85Kg/Mtr each channel lenth 0.35mtr. 2nos channel required =9.56x2x0,35)
Channel suport GI for down pipe 75x40x4.8mm 7.14kg/mtr each channel lenth 0.8mtr. 1nos channel required (=(7.14x0.8x1)
HG/DO Fuse mounting channel 75x40x4.8mm GI Channel (810mm long 2nos) each 2x0.810x7.14=11.57kg
Cantilever Support Channel 75x40x4.8 mm GI Channel (810 mm long,2 No's.) (7.14Kg./Mtr., 2 No's.) (Each 2x0.810x7.14= 11.57 Kg)
Cantilever Support Angle 50 X 50 X 6MM GI (1282 mm long) (4.5Kg./Mtr, 2 No's.) (Each 2x1.282x4.5= 11.54Kg)
Transformer Base GI Channel 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg)
Transformer Base Support GI Channel 100 X 50 X 6 MM (515 mm long) (9.56Kg./Mtr, 2 No's) (Each 2x0.515x9.56= 9.85Kg)
Transformer Belting Angle 50 X 50 X 6MM GI (3000 mm long)(4.5Kg./Mtr, 2 No's) (Each 2x3.0x4.5 Kg)
Transformer Belting Support 50 X 50 X 6MM GI (3000 mm long)(4.5Kg./Mtr, 2 No's) (Each 2x3.0x4.5 Kg)
LTDB Mounting Angle 50 X 50 X 6MM GI (1000 mm long)(4.5Kg./Mtr, 2 No's) (Each 2x1x4.5 Kg)
50x6mm GI Flat for earthing, 2.36kg/mtr., (2.5x7 mtr. For mesh formation, 12 Mtr. For LA and 2.5 mtr. For raising, 11 mtr for AB switch, 2.8 mtr for HG Fuse, 5x2 mtr. for DTR Nutral, (1.3+4.5) mtr. For DTR Body, 0.500 mtr for LTDB & AB Switch operating handle, 3 mtr. for Fencing) ( Each 65.6x 2.36= 154.81 Kg)
63 KVA , 11/ 0.4 KV (AL) Transformer BIS Energy level II Ammendment-4
LT Distribution Box with MCCB, Aluminium Busbar of single Bay with kit kat fuse for 63 KVA S/S
55mm2 All Alloy Aluminum Conductor (AAAC) - PVC Insulated (50 Mtr. Each Dtr.)
4CX95 Sq.mm SSSE XLPE COVERED CONDUCTOR
AB Switch(11KV,200A.3pole,50Hz)
H.G.Fuse( 11KV.200A.3Pole)
WEDGE CONNECTORFOR 55SQ.MM CONDUCTOR
Polycarbonate Bird Guard
Disc insulator (B&S)70 KN polymer
HW fitting B&S 70KN Polymer
Lightning Arrester(12KV,10KA) Station Class 2
11KV pin insulator polymer
HT stay set complete
HT stay Clamp (1.9Kg/pair)
HT stay insulator TYPE-C
7/10 SWG GI stay wire, Grade -2 (15Kg./ Set)
40 mm Nominal bore GI pipe (medium gauge) earthing device with 3 mtr .Long
GI Nuts & Bolts of Assorted size (25 Kg/ DSS DP)
GI Barbed wire/Anticlimbing device (3Kg /Pole)
Back Clamp for anti climbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8no's (2x0.59x0.510)
Danger plate 11kv
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8no's (2x0.59x0.510)
Name plate
Yellow Colour Paint for Background
Black Colour Paint for numbering
Stock, Storage & Insurance i.e 3% of A
Contigency @ 3% of C
Tools & Plants @ 2% of C
Transportation @ 7.5% of C
Erection Charges @ 5% of C (except Trf/Breaker/WPB/ H-Pole/HT stay set/PSC pole)
Erection Charges @ 10% of C (except Trf/Breaker/WPB/ H-Pole/HT stay set/PSC pole)
Erection Charges @ 20% of C (except Trf/Breaker/WPB/ H-Pole/HT stay set/PSC pole)
Concreting ratio 1:1.5:3 M-20 Grade with dimension ( 500X500X1700)= 0.425 Cu mtr per pole for 10mtr. PSC pole DP
PCC ratio 1:3:6 M10 Grade for DSS Area 5x3x0.1=1.5Cu.mtr
Fixing of stay set with 0.5Cum cement concrete foundation 1:3:6 size ( 900mmx600mmx900mm) using 40mm BHG metal with all labor and material except stay set , stay wire , stay insulator .
Construction of earthing chamber including installation of earthing pipe. Making earthing chamber including excavation soil treatment with bentonide powdwer calculation of earth resisrance ,including installation of 3Mtr. GI pipe 40mm/50mm including welding of flat GI around pipe
Laying of 4Cx95sq.mm LT XLPE Cable
SITC and Errection of GI Fencing with Gate
Supply of AL lugs suitable for 95sq.mm cable /conductor Crimping with cable and Fixing/connecting include supply and errection of PVC table as per voltage requirement.
Supply and errection of double compression flameproof Type Glanding for armoured cable3 ,5/4C 50-95sq.mm including making hole in Base plate and dressing of cable along with vermin proofing properly supply to be done as per the TPCODL specification and approved make dowells.
Supply of 1.1KV 4Core 70sq.mm XLPE insulation armoured Aluminium UG C able
Supply of HDPE PE80 pipe of 110mm diameter
Laying of 1.1KV 4CORE 70sq.mm XLPE insulation armoured Aluminium UG Cable
Laying of 110mm diameter HDPE Pipe
Supply and errection of double compression flameproof Type Glanding for armoured cable3 .5/4C 50-95sq.mm including making hole in Base plate and dressing of cable along with vermin proofing properly supply to be done as per the TPCODL specification and ap
Earth work excavation of soil
Earth work excavation of hard rock
Back filling with excavated soil out side and above the trench
Stock, Storage & Insurance i.e 3% of A
Contigency @ 3% of C
Transportation @ 7.5% of C
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.07 MB
BOQ_580138.xls
BOQ • 0.53 MB
Download all tender documents and submit your bid