Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 LAdmitted-Finance | ₹6.8 L | L1 | Admitted-Finance |
| 2 | L2₹8.0 LAdmitted-Finance | ₹8.0 L | L2 | Admitted-Finance |
| 3 | L3₹8.4 LAdmitted-Finance TETHAR BANIHAL | ₹8.4 L | L3 | Admitted-Finance |
| 4 | L4₹9.1 LAdmitted-Finance | ₹9.1 L | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S UNIQUE ELECTRICAL ENGINEERS CO L3 | M/S K.R CONSTRUCTIONS L4 | GIRI ELECTRICAL & SONS L1 | M/S PIONEER ENGINEERS L2 |
|---|---|---|---|---|---|---|---|
| 1.00Extension of LT network to provide reliable power supply to langer sits/security check post /toilet complex at chanderkote/karol/mehar/ramban in respect of ESD Ramban in respect of ESD Banihal | |||||||
| 1.11 | 8 Mtr ST pole (ST-410 SP 33) | 20 | Nos | 16,500 ₹3.3 L | 14,900 ₹3.0 L | 20,000 ₹4 L | 19,000 ₹3.8 L |
| 1.12 | Clamp for Shakle Insulator | 50 | Nos | 150 ₹7,500 | 130 ₹6,500 | 50 ₹2,500 | 150 ₹7,500 |
| 1.13 | 50 mm² AB (LT) Cable (3x35+1x70 mm²) XLPE(11 kV, 3C + Earth) | 1 | Kms | 2,80,000 ₹2.8 L | 4,50,000 ₹4.5 L | 1,70,000 ₹1.7 L | 2,74,000 ₹2.7 L |
| 1.14 | Suspension/Tension Clamp with eye hook | 40 | Nos | 80 ₹3,200 | 500 ₹20,000 | 50 ₹2,000 | 200 ₹8,000 |
| 1.15 | Straight Through Cable Jointing Kit | 4 | Nos | 7,000 ₹28,000 | 2,000 ₹8,000 | 2,500 ₹10,000 | 100 ₹400 |
| 1.16 | Insulating Piercing Connetors | 50 | Nos | 120 ₹6,000 | 100 ₹5,000 | 100 ₹5,000 | 100 ₹5,000 |
| 1.17 | LT Distribution Box | 10 | Nos | 5,000 ₹50,000 | 2,000 ₹20,000 | 5,000 ₹50,000 | 6,500 ₹65,000 |
| 1.18 | 30 mm Sq ACSR Conductor | 0.5 | Kms | 46,000 ₹23,000 | 43,000 ₹21,500 | 30,000 ₹15,000 | 25,000 ₹12,500 |
| 1.19 | 16 kN Polymer Shakle Insulator | 50 | Nos | 150 ₹7,500 | 40 ₹2,000 | 200 ₹10,000 | 30 ₹1,500 |
Tender Value
Refer Docs
EMD Value
₹21,500
Closing Date
15 May 2026, 2:00 pmClosed
Executive Engineer, ED JPDCL Batote
Office of Executive Engineer, ED JPDCL Batote
Supply Survey Erection Testing and Commissioning for Extension of LT Network at Yatri Niwas and Langer Sites at Chanderkote Karol Mehar Ramban under the Jurisdiction of Electric Sub Division JPDCL Ramban for SANJY 2026
2026_PDD_308999_1
eNIT 07 of 2026-27
Open Tender
Electrical Works
45 days
Ramban district
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Executive Engineer, ED JPDCL Batote
₹21,500
22 May 2026
30 Apr 2026
16 May 2026
30 Apr 2026
15 May 2026
30 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Extension of LT network to provide reliable power supply to langer sits/security check post /toilet complex at chanderkote/karol/mehar/ramban in respect of ESD Ramban in respect of ESD Banihal | |||||
| 1.11 | 8 Mtr ST pole (ST-410 SP 33) | 20 | Nos | - | - |
| 1.12 | Clamp for Shakle Insulator | 50 | Nos | - | - |
| 1.13 | 50 mm² AB (LT) Cable (3x35+1x70 mm²) XLPE(11 kV, 3C + Earth) | 1 | Kms | - | - |
| 1.14 | Suspension/Tension Clamp with eye hook | 40 | Nos | - | - |
| 1.15 | Straight Through Cable Jointing Kit | 4 | Nos | - | - |
| 1.16 | Insulating Piercing Connetors | 50 | Nos | - | - |
| 1.17 | LT Distribution Box | 10 | Nos | - | - |
| 1.18 | 30 mm Sq ACSR Conductor | - | Kms | - | - |
| 1.19 | 16 kN Polymer Shakle Insulator | 50 | Nos | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.22 MB
SBD07PDF.pdf
Tender Documents • 0.71 MB
BOQ_1000687.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid