Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.7 LAccepted-AOC SHOP NO 107 MOHAN SINGH PLACE NEW DELHI 110001 | NEW DELHI | DELHI | 110001 | 1 | Accepted-AOC 1 | |
| 2 | 2₹6.9 L+₹14,749.26 (2.19%)Rejected-Finance | 2 | Rejected-Finance 2 | |
| 3 | 3₹7.2 L+₹52,019.86 (7.74%)Rejected-Finance | 3 | Rejected-Finance 3 | |
| 4 | 4₹7.4 L+₹70,920.12 (10.6%)Rejected-Finance NULL | 4 | Rejected-Finance 4 | |
| 5 | 5₹8.4 L+₹1.7 L (25.1%)Rejected-Finance B 17 2 GALI NO 20 JITAR NAGAR NEAR PARVANA ROAD KRISHNA NAGAR EST DELHI 51 | NEW DELHI | DELHI | 110001 | 5 | Rejected-Finance 5 |
Tender Value
₹8.8 L
EMD Value
₹17,950
Closing Date
20 Feb 2026, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EEE/KPZ
EEE/KPZ
Provision of lighting arrangement in mpl. Park near house no 16/1 Shakti nagar ,Flat no 129 SFS, 146 A SFS, 80 LIG Gulabi bagh and Sindhora kalan park near project office in ward no 69 under Keshav puram zone.
2026_MCD_266866_1
TC/ENGG./EEE/KPZ/2025-26/49.3
Open Tender
Electrical Works
Percentage
60 days
EEE/KPZ
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
₹17,950
27 Aug 2026
12 Feb 2026
20 Feb 2026
12 Feb 2026
20 Feb 2026
12 Feb 2026
120 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1ABC | |||||
| 1.01 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe etc.(but without charcoal/ coke and salt ) as required. | 9 | Each | 5,368 | ₹48,312 |
| 1.02 | Providing and fixing 6 SWG dia G.I. wire on surface or in recessfor loop earthing along with existing surface / recessed conduit/ submain wiring / cable as required. | 472 | Metre | 42 | ₹19,824 |
| 1.03 | Laying of one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 Sq mm | 496 | Metre | 37 | ₹18,352 |
| 1.04 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required Upto 35 Sq mm | 90 | Metre | 28 | ₹2,520 |
| 1.05 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) | 378 | Metre | 247 | ₹93,366 |
| 1.06 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) | 23 | Metre | 127 | ₹2,921 |
| 1.07 | Supplying, installation, Testing & Commissioning of 40 watt Street light LED fixture powder coated pressure die cast aluminum body with driver as
per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP 66,IK-10, CRI >80, under voltage and over voltage protection, EMI EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to
65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K
/ 5700°K /6000°K/6500°K (As per ANSI Bin),SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete
n all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen eff >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required
for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise 90.C | 33 | Each | 1,879 | ₹62,007 |
| 1.08 | Providing and laying of HDPE PIPE of 40 mm outer dia with PN 4 rating by Hand moling/ Manual Method confirming to IS 4984 592 | 37 | Metre | 592 | ₹21,904 |
| 1.09 | Supply of XLPE insulated PVC sheathed AL. conductor armoured Cable 1.1 KV grade conforming to IS-7098 of following size- (a) 2X6 Sq mm | 586 | Metre | 95 | ₹55,670 |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
Tender_condition_21.pdf
Tender Documents • 0.41 MB
MCD_GCC_Circulars_2025.pdf
Tender Documents • 12.97 MB
BOQ_310161.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .