Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-AOC 41B 1H JAYANTIPUR PREETAM NAGAR ALLAHABAD | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹8.9 L+₹1.0 L (12.9%)Rejected-Finance | L2 | Rejected-Finance Being Not Lowest | |
| 3 | L3₹9.4 L+₹1.6 L (19.7%)Rejected-Finance GF AKRITI TOWER 19 B VIDHAN SABHA MARG LUCKNOW PIN 226001 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226001 | L3 | Rejected-Finance Being Not Lowest | |
| 4 | L4₹9.6 L+₹1.7 L (21.9%)Rejected-Finance 93 SARASWATI PURAM COLONY SG PGI LUCKNOW UP 226 014 | LUCKNOW | LUCKNOW | UP | 226014 | L4 | Rejected-Finance Being Not Lowest | |
| 5 | L5₹9.8 L+₹1.9 L (24.5%)Rejected-Finance | L5 | Rejected-Finance Being Not Lowest |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
23 Jul 2020, 6:00 pmClosed
Shri Prabhat Kumar Singh, AGE (I)
AGE (I) Manauri Allahabad-212212
PROVISION OF SERVO CONTROL VOLTAGE STABILIZER, SECURITY LIGHT FITTINGS AND FIRE ALARM SYSTEM AT 24ED AF STN MANAURI
2020_MES_325298_2
8746/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Manauri, Allahabad
Class E category b (i) or c (vi)
6 documents required · 6 mandatory
₹500
AGE (I) AF Manauri
₹19,000
Yes
20 Aug 2020
7 Jul 2020
25 Jul 2020
7 Jul 2020
23 Jul 2020
7 Jul 2020
Amount
Supply , fixing, testing and comissioning to servo control voltage stabilizer capacity 50 KVA (confirming to BIS 9815:Part 1: 1994) fully automatic three phase naturally oil cooled, unbalanced supply and unbalanced load type, copper wounded indoor type 97% effenciency class C type Secondary protection, metalllic body duly powder coated with lifting hooks 02 nos, digital display type, relay free smooth and silent operation with Ist filling of transformer oil up to level and designed for input variation between 320 volt to 470 volts with output voltage stabilized at 415 with accuracy (±) 2.5% and speed of correction upto 8 volt per second, frequency 47 to 53 HZs ,digital LED display (20x2 matrix) (input /out put voltage & current) correction 25 to 40 Volts/ Sec, Nil true to input wave form distoration, Response time less than 10 ms, Efficiency 97 to 99%, break down strength & IR-2500V AC for 2 minutes, greater than 50mega Ohms at 500 V DC, Duty cycle- continuous 24x7, Wide ambient temperature from 20 degree to 50 degree C, incl making all connection using suitable size of copper cable with minimum 02 year warranty complete as per manufacturers's speification and design. Degree of protection are:- (a) Over load cut off and short circuit protection (b) Low/ High voltage alarm / cut-off (c) Single phase prevention alarm or Cut-off (d) High temperature alarm or Cut-off (e) Reverse phase cut-off (f) Stabilizer by pass system Make :- As specified in Appendix 'B' (list of Makes) to Particular specifications.
M&L for earthing complete with copper earth plate electrode size 60 CM x 60 CM x 3.15 MM thick buried directly in ground (earth pit not less than 2.25 Mtrs below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to copper earth strip 20 x 3.0 MM by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including provision of earth strip protected by galvanised iron 32 mm bore medium grade pipe with all fittings, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20 mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh , 40 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced , JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I and specified including provision of earth wire protected by 15 MM dia light grade GI pipe and watering GI pipe shall be 40 MM bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified and directed. Notes :-(i) The concrete pit shall be made in PCC 1:3:6 type C-1, 40mm thick precast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate with suitable MS handle in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. Reinforcement in RCC cover shall be of 8mm dia TMT bars laid @150mm c/c both ways. (ii) Item includes the cost of 7.5 metre GI pipe for protection of earth strip. Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.5 metre earth strips from above normal ground level. Any variation in length shall be adjusted through deviation order. (iv) Plate electrode shall be surrounded by adequate quantity of charcoal dust & salt to a packed thickness of 15 cm on all sides.
Supply and fixing copper earth strip 20 x 3.0 mm burried in ground to connecting earthing complete.
Supply and laying galvainesd steel tubing light grade 50 mm dia of bore fixed with pole/ surface of wall / laid in trench etc as site using 02 Nos clamp made out by GI strip in size 25x4 mm with nut bolt and washer etc all as directed. Make :- As specified in Appendix 'B' (list of Makes) to Particular specifications.
Supply, laying, thembling, jointing, fixing with pole/ wall etc/ clamping on surface of wall to XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade aluminium conductor cross section area 50 Sqmm 3.5 core (earthed) with suitable size of gland etc complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection cover and pipe shall be measured and paid for separately under respective items of this schedule. Make :- As specified in Appendix 'B' (list of Makes) to Particular specifications.
Supply and fixing LT end termination jointing kit suitable for 50 Sqmm x 4 core XLPE 1100 volt grade cable indoor type heat shinkable complete all as directed. Make :- As specified in Appendix 'B' (list of Makes) to Particular specifications.
Supply and fixing 4 pole off load change over switch, 100 Amps rated, 415 volt grade in sheet metal enclouser mounting on surface of wall with suitable sizefixing arrangement incl making all connection complete all as specifed and directed. Make :- As specified in Appendix 'B' (list of Makes) to Particular specifications.
Supply and fixing of 60 watt LED street light fitting energy saving IP 65 protection mounting on with provn of MS equal angle iron frame of size 40mmx40mm and 5 mm thick, 600mm long with pole through GI strip bracket of size 25mmx5mm including nuts, bolts and washers as required at site complete all as specified and directed. Note :- Fitting shall be of Bajaj Cat No BRTFG 60W LED V3 ( EDGE) or Crompton cat Part No LSTP-60-CDL (NEXUS+) or equivalent model of make Philips/Wipro. Light fitting of other make of higher capacity may be used without any price adjustment.
Supply and fixed of flood light fitting LED 160/170 W equipped with IP66 protection with mounting bracket nut bolt washer to be fix on pole/ wall etc all as site making all connection using suitable three core flexible copper cable drawn through in flexible conduit pipe from control box to light fittings complete all as directed. Note :- (i) Fitting shall be of Bajaj (Turbo) cat No BARFEG 160W LED (white) or Crompton cat Part No LSFO-170-CDL/60 (Secure) or philips cat part No BVP410 LED 170 CW HE NB FG S4 XTFCL or equivalent model of make Wipro. Light fitting of other make of higher capacity may be used without any price adjustment. (ii) Cable from MCB to fitting shall be included in unit rate quoted by contractor.
Supply, laying, thembling, jointing, fixing with pole/ wall etc/ clamping on surface of wall to XLPE insulated under ground, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade aluminium conductor cross section area 10 Sqmm 2 core (earthed) with suitable size of gland etc complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection cover and pipe shall be measured and paid for separately under respective items of this schedule. Make :- As specified in Appendix 'B' (list of Makes) to Particular specifications.
Supply and fixing of three core copper flexible cable , PVC insulated sheathed heavy duty in size 1.5 Sqmm drawn through in steel tubular pole from control box to fittigs for making inter connection complete with all site work and directed. Make :- As specified in Appendix 'B' (list of Makes) to Particular specifications.
Supply and laying galvainesd steel tubing light grade 40 mm dia of bore fixed with pole/ surface of wall / laid in trench etc as site using 02 Nos clamp made out by GI strip in size 25x4 mm with nut bolt and washer etc all as directed. Make :- As specified in Appendix 'B' (list of Makes) to Particular specifications.
S&F in replacement to shock proof, fire retardant rust proof, out door pole kiosk box of size 295 x195 x100 MM made out of one piece Engineer plastic moulding of siemens grey colour with in built 4 Nos aluminium bus bar of 60 Amp rating colour strip mounting on insulators both side fitted on DMC unbrakable insulator including fixing arrangement as clamps made out by GI strip in size 25mm x 4 mm and nut bolts washer with painting in two coat syenthic enamel paint over one coat of red oxide primer etc all complete all as specified and directed. Make : Model- GSJB-3020 of Sintex or equivelent as specified in List of makes.
Excavating in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for wall foundation etc or for manholes etc not exceeding 10 Sqm area on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil.
Returning, filling in, including spreading, levelling, watering and well ramming in layers each not exceeding 25 cm thick in soft/loose soil.
Removing excavated surplus soil to a distance not exceeding 50 metre and depositing where directed at level not exceeding 1.5 metre above the starting point.
M&L for Sand cushioning in trenches with clean dry unsheathed gently punning around cable for protection complete. Note : Only punned thickness shall be measured for payment
M&L for brick, old sub class 'B' well burnt, laid dry flat in trenches for protection of cable over LT cable, complete all as specified and directed.
M&L for providing PCC 1:4:8, type D2 ( using 40 mm graded crushed stone aggregate) in foundation concrete encasing the pole upto GL.
M&L for PCC 1:3:6, type C-2 ( using 40 mm graded stone aggregate ) as in mass concrete, foundation of Pole. Note :- Volume of pole shall deducted for payment purpose.
M&L for Providing cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate in coping/ pedastal to poles including weathering, slightly rounded or chamfered angles including necessary form work complete and finishing the exposed surface even smooth using extra cement. Note :- Volume of pole shall deducted for payment purpose.
Supply, installation, testing and commissioning of floor/ surface mounting addressable microprocessor fire alarm control main control with BS EN 54 and indicating panel two sounder circuits (1A max) complete with LC Display with back light illumination autodialler and push buttion to acknowledge alarm, testing and reset suitable for operationon 230 Volt single phase (single loop) 50 HZs Ac supply 24 V DC supply with suitable capacity charger maintenance free batteries and battery charger including paiting labeling earthing etc compatable with detector for communication to detectors and response indicators together with mimic diagram made on Auto CAD and pasted on acrylic sheet with data logging facility and 2 x 16 character LCD, conforming to IS:2189 and BS EN 54 of capacity from 99 detector and 99 module devices upto 200 detector single loop 6*40 character LC dispaly 2 sounder circuits PTR requires network card and modules (Per each loop) with PA based evacuation system with its own stand by power backup supply with batteries, battery charger incl an auto dialling facility and potential NO & NC contacts and a 80 watts PA amplifier and capacity not less than 8 zones etc incl making all connection and fixing accessories complete all as specified in particular specifications and directed. Note :- Quoted rate shall be included cost of batteries (in qty, rating capacity) suitable for backup on full load upto 24 hrs with suitable raiting charger and GI angle factory made made battery stand as per origional maufacture. Make:- Honeywell Morley IAS Model MOF 714001115 or equivelent in Ravel/ Safeway/ Suraksha / Siemens/ System Sensor
Supply, installation, testing and commissioning to addressable type certified to EN 54 part A 1 58 degree addressable type, microprocessor based, programable inteligent type,blue light optical thermal heat detector with base photo electric with rate of rise cum fixed temperature as per IS; 2175 distributed memory having resident memory and resident decision alongthm detector with in built isolator complete including necessary connection all as specified and directed.Make:- Honeywell Morley IAS Model MOFHMRHSE or equivelent in Ravel/ Safeway/ Suraksha / Siemens/ System Sensor
Supply, installation, testing and commissioning to addressable type certified to EN 54 addressable type, microprocessor based, programable inteligent type,blue low profile light optical smoke cum thermal detector (100% substitute of ionisation detector) with base photo electric with self built imtelligence as per IS; 11360 distributed memory having resident memory and resident decision alongthm detector with in built isolator complete including necessary connection all as specified and directed. Make ;- Honeywell Morley IAS Model MOFHMPSES2 or equivelent in Ravel/ Safeway/ Suraksha / Siemens/ System Sensor
Supply, installation, testing and commissioning to addressable imtelligence having inbuilt microprocessor , memory and decision alogrithm twin angle optical smoke with both forward and backward light scattering mechanism cum thermal multicriteria detector with complete assembly with base unit for detector having in built isolator including necessary connection all as specified and directed. Make ;- Morley Model MOFMIB501APIV or equivelent in Ravel/ Safeway/ Suraksha / Siemens/ System Sensor
Supply and fix addressable type red add manual call with flush mounting glass box resettable type suitable to continuous monitoring including making connection etc point break glass type compatible with main fire alarm control board microprocessor based as per IS-2189 and including chain hammer facility and blinking facility complete all as specified and directed. Make ;- Honeywell Morley IAS Model MOFH MMC PGL ASS or equivelent in Ravel/ Safeway/ Suraksha / Siemens/ System Sensor
Supply, installation, testing and commissioning of beam master detector with standard transmitter and receiver with power supply unit in required modules suitable for continious monitoring ISI marked certified to pertain EN including making all connections etc all as specification and directed. Make:- Honeywell Morley IAS /Ravel/ Safeway/ Suraksha / Siemens/ System Sensor
Supply, installation, testing and commissioning of addressable wall mounting intelligent electronic sounder cum strobe ISI marked conformimng to perticular IS and EN incl making all connection complete. Make:- Honeywell Morley IAS /Ravel/ Safeway/ Suraksha / Siemens/ System Sensor
Supply, installation, testing and commissioning addressable remote response indicators having flashing green LED and Red LED for indication of fire and continous monitoring including necessary connection to pin point location of fire complete all as specified and directed. Make:- Honeywell Morley IAS /Ravel/ Safeway/ Suraksha / Siemens/ System Sensor
Supply, installation, testing and commissioning of addressable electronic speaker cum Hooter with range of 25-30 meter with output not less than 4 Watt including necessary connection complete all as specified and directed. Make:- Honeywell Morley IAS /Ravel/ Safeway/ Suraksha / Siemens/ System Sensor
M&L Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 4sqmm FRLS, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of size not less than 20mm dia including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 4 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete. Note:- (a) Two runs of 4 sqmm cable and one run of 4 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish. Make :- As specified in Appendix 'B' (list of Makes) to Particular specifications.
M&L Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 1.5sqmm FRLS, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of size not less than 20mm dia including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 1.5 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete. Note:- (a) Two runs of 1.5 sqmm cable and one run of 1.5 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish. Make :- As specified in Appendix 'B' (list of Makes) to Particular specifications.
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ.
Continental Engineers and contractors
Prime Technology
M/S Reliance Construction
LUMOS INFRA PVT LTD
M/S Garg Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .