Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC | L1 | Accepted-AOC OK | |
| 2 | L2₹17.0 L+₹3.1 L (22.0%)Rejected-AOC | L2 | Rejected-AOC OK | |
| 3 | L3₹17.3 L+₹3.4 L (24.3%)Rejected-AOC | L3 | Rejected-AOC OK | |
| 4 | L4₹17.6 L+₹3.7 L (26.4%)Rejected-AOC PLOT NO 28 SANTOSHIMA COLONY WEST MARREDPALLY SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L4 | Rejected-AOC OK | |
| 5 | L5₹18.5 L+₹4.6 L (32.7%)Rejected-AOC | L5 | Rejected-AOC OK |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
17 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI MAHAVIR SINGH, IDSE
GARRISON ENGINEER (SOUTH), MUDFORT, SECUNDERABAD
REPAIRS / REPLACEMENT OF COOLING APPLIANCES OF OTM ACCN AT DIV UNITS, CDA, DGQA AND EME AREA OF AGE E/M (SOUTH) UNDER GE (SOUTH) SECUNDERABAD
2021_MES_424923_1
GE (S)/SEC/TOKEN - 75 OF 2020 - 21
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Secunderabad
For Enlisted contractors class E and above category c (i) and for unenlisted contractors meeting the eligibility criteria of above class and category for along eligible class with EMD
5 documents required · 5 mandatory
₹500
GE SOUTH, MUDFORT, SECUNDERABAD
₹50,000
Yes
1 May 2021
23 Feb 2021
19 Mar 2021
23 Feb 2021
17 Mar 2021
5 Mar 2021
24 Feb 2021 - 4 Mar 2021
60 days
Amount
Replacement of old unserviceable compressor with new Factory made hermatically sealed compressor including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc for Refrigerator of any capacity complete all as specified and as directed and as directed .
All as per Sl item No 1 above but for Deep Fridger of any capacity complete all as specified and as directed.
All as per Sl item No 1 above but for Window Type AC 1.0/1.5/2.0 Ton Capacity complete all as specified and as directed.
All as per Sl item No 1 above but for Water Coolers 40 / 80 Ltrs complete all as specified and as directed.
All as per Sl item No 1 above but for Water Coolers 60 / 120 Ltrs complete all as specified and as directed.
All as per Sl item No 1 above but for Water Coolers 150/150 Ltrs complete all as specified and as directed.
All as per Sl item No 1 above but for Split type AC 1.5 Ton capacity complete all as specified and as directed.
Replacement of old over load protector including relay with new over load protector including relay for Refrigerator & Deep Fridger of any Capacity complete all as specified and as directed.
All as per Sl item No 9 above but Thermostat complete all as specified and as directed.
All as per Sl item No 9 above but Capillary tube including filter / stainer complete all as specified and as directed.
All as per Sl item No 9 above but Magnetic door gasket complete all as specified and as directed.
All as per Sl item No 9 above but Evaporator unit complete including required brazing all as specified.
All as per Sl item No 9 above but Condenser unit complete including required brazing all as specified.
Replacement of old unserviceable Over load protector / relay package assembly with new relay package assembly for Water Coolers 40 / 80 Ltrs capacity complete all as specified and as directed.
All as per Sl item No 15 above but Thermostat complete all as specified and as directed.
All as per Sl item No 15 above but Capillary tube including filter / stainer complete all as specified and as directed.
All as per Sl item No 15 above but Condensor fan motor 1/ 16 HP 230 volts including blades complete all as specified and as directed suitable for 40/80 , 60/120 & 150/150 Ltrs capacity.
All as per Sl item No 15 above but PVC Ball valve high pressure with polythene float and fly nut screwed for Iron pipe 15 mm dia complete all as specified and as directed.
All as per Sl item No 15 above but Magnetic door gasket complete all as specified and as directed.
All as per Sl item No 15 above but GI / Stainless steel water drain tray complete all as specified and as directed.
All as per Sl item No 15 above but Running Capacitor 10 MFD complete all as specified and as directed.
All as per Sl item No 15 above but Self closing taps, cast copper alloy, chromium plated screwed for iron pipe 15 mm dia complete all as specified and as directed suitable for 40/80 , 60/120 & 150/150 Ltrs capacity.
Replacement of old unserviceable Over load protector / relay package assembly with new relay package assembly for Water Coolers 60/120 Ltrs and 150/150 Ltrs capacity complete all as specified and as directed.
All as per Sl item No 24 above but Thermostat complete all as specified and as directed.
All as per Sl item No 24 above but Capillary tube including filter / stainer complete all as specified and as directed.
All as per Sl item No 24 above but PVC Ball valve high pressure with polythene float and fly nut screwed for Iron pipe 15 mm dia complete all as specified and as directed.
All as per Sl item No 24 above but Magnetic door gasket complete all as specified and as directed.
All as per Sl item No 24 above but GI / Stainless steel water drain tray complete all as specified and as directed.
All as per Sl item No 24 above but Running Capacitor 20/25 MFD complete all as specified and as directed.
Replacement of old unserviceable relay with new relay for window type Airconditioner 1.5 Ton, 2.0 Ton capacity of any make and model complete all as specified and as directed.
All as per Sl item No 31 above but over load protector complete all as specified and as directed.
All as per Sl item No 31 above but Thermostat complete all as specified and as directed.
All as per Sl item No 31 above but Capillary tube including filter / stainer complete all as specified and as directed.
All as per Sl item No 31 above but Condensor fan motor double speed 1/ 6 HP 230 Volts including blades complete all as specified and as directed.
All as per Sl item No 31 above but Starting capacitor 80 - 100 MFD complete all as specified and as directed.
All as per Sl item No 31 above but Running Capacitor 36 MFD complete all as specified and as directed.
All as per Sl item No 31 above but Coir filter suitable size complete all as specified and as directed.
All as per Sl item No 31 above but Condenser unit complete including required brazing complete all as specified and as directed
Replacement of old unserviceable submersible pump with new submersible pump, 220 Volts, power 0.025 HP, single phase 18 Watt, 1.6 Mtr head or suitable for site requirement complete for Desert cooler of any make and model complete all as specified and as directed
All as per Sl item No 41 above but Khas - khas screen complete set complete all as specified and as directed.
All as per Sl item No 41 above but Fan motor 90 Watt, Three phase, Speed 1400 rpm, volts 130-230, High speed complete all as specified and as directed.
Repairs to Desert cooler wheel stand including denting, welding, cutting of worned out portion of MS angle iron and replacing the same with new MS angle iron of size and gauge as existing and painting with two coats of synthetic enemel paint over one coat of red oxide including replacement of new wheels complete all as specified and as directed and directed.
Replacement of old unserviceable fan motor 1/7 HP capacity with new fan motor 1/7 HP capacity 1250 RPM or suitable rating to site requirement for 1.5 Ton / 2.0 Ton/3.0Ton capacity split type Airconditioner of any make and model complete all as specified and as directed.
All as per Sl item No 45 above but Fan motor 1 / 8 HP capacity 900 RPM complete all as specified and as directed.
All as per Sl item No 45 above but Starting capacitor 60 - 100 MFD complete all as specified and as directed.
All as per Sl item No 45 above but Running capacitor 36 / 45 MFD complete all as specified and as directed.
All as per Sl item No 45 above but Running capacitor 50 / 50+6 MFD complete all as specified and as directed.
All as per Sl item No 45 above but Condenser unit including required brazing complete all as specified and as directed.
Supply and replacement of PVC sheathed copper cable of size three core 2.5 sq mm length 3 m suitable for window type AC/Split AC complete all as specified and as directed
Supply and replacement of fan blade of existing size for 1.5/2 Ton split type AC complete all as specifed.
Supply and replacement of remote control unit for Split type Air Conditioner of 1.5 Ton/2.0 Ton capacity of any type and make as per site complete all as specified and as directed
Supply and replcement of Oscillator motor including blade for 1.5 Ton / 2.0 Ton capacity Air Conditioner of any make complete all as specified and as directed
Supply and replcement of blower motor for 1.5 Ton / 2.0 Ton / 3.0 Ton capacity of split type Air Conditioner of any make complete all as specified and as directed
Supply and replacement of PCB for split AC any type and any make 1.5 Ton, 2 Ton & 3 Ton capacity complete all as specified and as directed
Replacement of old unserviceable Rectifier unit of voltage stabilizer single phase upto 5 KVA capacity complete all as specified and as directed.
All as per Sl item No 57 above but Relay unit complete all as specified and as directed.
All as per Sl item No 57 above but Switch socket combination 15 Amps 2/3 pin complete all as specified and as directed.
All as per Sl item No 57 above but Indication bulbs complete all as specified and as directed.
All as per Sl item No 57 above but Volt meter 0 - 250 Volts, AC Single phase complete all as specified and as directed.
All as per Sl item No 57 above but Transformer Unit of 5.0 KVA ,4.0 KVA,3.0 KVA Capacity complete all as specified and as directed.
All as per Sl item No 57 above but Transformer Unit of 2 KVA ,1.0 KVA,0.5 KVA Capacity complete all as specified and as directed.
Supply and replacement of Sheet Metal single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 240 Volts, 30 amps capacity all as specified for split AC.
Repairs to body of cooling appliances including denting, cutting worn out portion of body upto 0.5 Sqm area and replacing with MS sheet of same guage including necessay welding etc complete all as specified and as directed.
Spray painting with two coats of synthetic enamel paint over a coat of red oxide primer on water coolers body complete all as specified and as directed
Disconnect electrical connection, removing copper line, discharge line of split type AC up to1.5 Ton capacity including indoor and out door units and all accessories and shifting/reinstalling and testing the whole unit of split type AC in new location with suitable size and making the holes in walls complete all as specified and as directed.
S & F Copper pipe length 3 mtr suitable for 1.5 Ton AC/2 Ton AC complete all as specified and as directed.
Removing electrical connection, shifting of window type AC up to 2 Ton capacity to new location where directed and fixing the same either on window or on wall with required opening and neceessary wooden/iron frame work including making good to mach with the existing surface complete all as specified and as directed.
Replacement of old unserviceable 4 MFD capacitor with new 4MFD capacitor complete all as specified and as directed.
Supply and replacement of desert cooler front side PVC grills of suitable size/make as per sample complete all as specified and as directed.
Suply and replacement of front side PVC grill of suitable size for split type AC complete all as specified and as directed.
Supply and replacement of front side PVC grills of suitable size for window type AC complete all as specified and as directed.
Supply and replacement of Osillator motor incl blade for Desert Coolers of any capacity complete all as specified and as directed.
Supply and Charging of refrigerant R-22/R-134A/410 gas including cost of welding, leak detection and refitting the same in entire system, including replacing defective liquid strainer and capaillary tube including testing & commissioning complete to the satisfaction of Engr-in- Charge for 1.0 ton/1.5 ton and 2 ton window type AC complete all as specified and as directed
Supply and Charging of refrigerant R-22 /R-134A/410/R-32 gas including cost of welding leak detection and refitting the same in entire system, including replacing defective liquid strainer and capalliary tube for 1.5 ton and 2.0 ton split AC complete all as specified and as directed
Supply and charging of refrigerant gas R-22/ R-134A including cost of welding, leak detection, rectification in the entire system with replacement of liquid strainer and capillary tube, testing and commissioning of water coolers of 40/80 ltrs, 60/120 ltrs and 150 ltrs capacity complete all as specified and as directed
Supply and charging of refrigerant 134A including cost of welding, leak detection, rectification in the entire system with replacement of liquid strainer and capillary tube, testing and commissioning of refrigerator of 165/180/286/300/310/350 ltrs capacity complete all as specified and as directed
Supply and charging of refrigerant 134A including cost of welding, leak detection, rectification in the entire system with replacement of liquid strainer and capillary tube, testing and commissioning of Deep Fridger of any capacity complete all as specified and as directed
Attending the complaints pertaining to cooling appliances such as Split /window type Air Conditioners , Refrigerators, deep fridgers , water coolers and desert coolers of any size/capacity lodged by users in person and reporting to the concerned area JE E/M complete all as specified and as directed by Engineer-in-Charge. Note: Any consumable items will be measured and paid seperately
Servicing/Cleaning of Split type/window type Air Conditioners , Refrigerators, deep fridgers and water coolers of any capacity with chemical acid complete all as specified and as directed by Engineer-in-Charge
Servicing/Cleaning of Desert Coolers of any capacity with suitable chemical acid complete all as specified and as directed by Engineer-in-Charge
Sri venkateswara Electricals
SHANTI MARKETING AND SERVICES
Universal refrigeration and Engineering Company
BHATNAGAR ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .