Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 126 B I MESS ROAD RAI MARKET AMBALA CANTT AMBALA CANTT HARYANA 133001 | AMBALA | HARYANA | 133001 | Admitted-Finance |
| 2 | Admitted-Finance MUZAFFARNAGAR MEERUT ROAD GEHRA BAGH OPP PWD WARE HOUSE MUZAFFARNAGAR UTTAR PRADESH 251002 | MUZAFFARNAGAR | UTTAR PRADESH | 251002 | Admitted-Finance |
| 3 | Admitted-Finance 23 B NEW MANDI NEW MANDI MUZAFFARNAGAR MUZAFFARNAGAR UTTAR PRADESH 251001 INDIA | MUZAFFARNAGAR | UTTAR PRADESH | 251001 | Admitted-Finance |
Tender Value
₹4.6 L
EMD Value
₹5,000
Closing Date
6 Nov 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC MEERUT
130 D PAARESHAN BHAWAN BHAWAN VICTROA PARK MEERUT
WORK TENDER
2021_UPTCL_638426_1
T-59/21-22/ETC/MT
Open Tender
Electrical Works
Item Rate
90 days
BARAUT
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
SE ETC MEERUT
₹5,000
16 Nov 2021
30 Oct 2021
8 Nov 2021
30 Oct 2021
6 Nov 2021
30 Oct 2021
90 days
Amount
PART-A (WORK)
Erection of main & Auxiliary Structure by shifting of Structures from store to site of erection and erection of structures as per drawing (Nut bolts & washer and structures will be provided by dupartment free of cost)
Main & Auxiliary structures
Erection of following equipments as per instruction manual of equipments including shifting of equipments from store to erection site including all other associated works to complete the job satisfactorily:-
33 KV triple feeder panal
33 KV Circuit Breaker
33 KV Bus Isolator
33 KV line Isolator
33 KV C.T. Junction box
33 KV P.T. Junction box
Interconnection of jumper of equipments from bus bar to BI, BI to CT, CT to CB CB to LI, LI to CT with help of twin ACSR panther conductor, the work includes cutting, bending of conductor and jumpering, clamping including all other associated work to complete the job satisfactorily.
Loading/unloading and carriage of miscellanceous material and equipments from various S/S under ETC Meerut to 132 KV S/S Chapprouli & Kirthal under ETD-Baraut.
Sorting and stacking of S/S galvanized steel structures (as per bill material) and to make ready the same structure-wise for loading into truck.
Safe carriage of S/S steel structures into truck to be arranged by the contractor at his own cost from EFU to 132 KV S/S Chapprouli & Kirthal. Approx distance 850 Km.
Unloading of structures and stacking the all above structure in store at 132 KV S/S Chapprouli & Kirthal.
Providing & Fixing of Phase Plate (R,Y,B phase) of 2 mm Thick Aluminum sheet of size 5'' dia. Covering of 3M HIP/MDF Retro reflected sheet in single piece along mounting with GI Nuts, Bolts & Washer 01 set Comprise.
Laying of following size of control cables in the cable trench from control relay panels to various equipments, marshaling boxes, junction boxes in the switchyard as per cable schedule its saddling at every 75 cm distance with MS saddles of size 25x3mm size including carriage of cable drums from stores to laying site and shifting back to store and all other associated works to complete the job satisfactorily:-
2Cx2.5 sq. mm cable unarmored
4Cx2.5 sq. mm cable unarmored
6Cx2.5 sq. mm cable unarmored
10Cx2.5 sq. mm cable unarmored
Termination of following sizes of control cables as laid above as per cables schedule ( Prepared by contructor) including making necessary holes in gland plates or box wherever required, supply and fixing of letter marked ferrules and no marked for each core of cable and its termination as per drawing on equipments cable termination blocks.
2Cx2.5 sq. mm cable unarmored
4Cx2.5 sq. mm cable unarmored
6Cx2.5 sq. mm cable unarmored
10Cx2.5 sq. mm cable unarmored
Cutting, straightening , bending & laying of 75x10/50x6 mm MS flat (Provided by the Department) 700 mm below ground level and above ground level & connecting with existing earthmat of substation and proper earthing at different structure and equipments (As per drawing).
PART-B (SUPPLY)
33 KV Isolator clamp for twin panther conductor made of aluminum alloy LM-6.
33 KV CT clamp for twin panther conductor made of aluminum alloy LM-6.
4 Bolted type PG clamp made of Aluminum alloy LM-6 with GI Nuts, Bolts & Washer suitable for Zebra to panther.
4 Bolted type PG clamp made of Aluminum alloy LM-6 with GI Nuts, Bolts & Washer suitable for Panther to Panther.
01 Bolt 60 mm spacing spacer for twin Panther conductor.
250 Watt HPSV flood lighting.
KARAN SINGH
RAHUL ELECTRIC ENGGINEERING WORKS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .