| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 LAccepted-AOC 205 IIND PHASE INDUSTRIAL AREA BARMER 344001 | BARMER | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC lowest bid | |
| 2 | L2₹24.6 L+₹6.9 L (38.7%)Rejected-Finance 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | L2 | Rejected-Finance quoted high rate | |
| 3 | Rejected-Technical MAHAVEER NAGAR BARMER RAJASTHAN 344001 MAHAVEER NAGAR BARMER RAJASTHAN 344001 | BARMER | RAJASTHAN | 344001 | - | Rejected-Technical REJECTED |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
13 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF JAISALMER
HQ CWE AF JAISALMER
REPAIRS TO ELECTRIC SUPPLY HT NET WORK AT AIR FORCE STATION CHOUHTAN UNDER GE AF UTARLAI
2024_MES_667817_1
80316
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
GE (AF) UTARLAI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) UTARLAI
₹40,000
Yes
17 Oct 2024
25 Jul 2024
14 Sept 2024
25 Jul 2024
13 Sept 2024
8 Aug 2024
Amount
M&L for servicing, calibration, testing and setting of fault tripping relays as mentioned in maintance and operation manual of 11 KV HT VCBs as per OEM instructions complete all as specified and directed.
S&F in replacement Tripping Coil 24/110 Volts DC supply complete as per existing make and type complete all as specified and directed.
S&F in repacement Round Type Transformer Breather Set with Silca gel suitable for 11/0.433 KV Transformer as per existing at site complete all as specified and directed.
S&F in replacement of switch Air break Gang Operated Switch outdoor type HT 11 KV triple poles 200Amps with fixed contacts of phosphorus bronze and moving contacts of copper with mechnically operating from ground level vertical mounted complete with HT insulator on steel frame (15 insulator type) for vertical installation single break provided with locking arrangement consisting of MS channel, HT post top porcelene insulators with drop out fuses, operating rod made out of 20 mm GI pipe medium grade worked from ground level with handle and locking arrangment including jumpering, lead of wire/cable complete all as per specified and directed.
Supply, lay, test, joint and commission in replacement XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric powercable heavy duty with aluminium conductor of size cross sectional area 95 sqmm 3 core, 11000 Volts grade (11 KV earthed system); laid in trenches/under floor/through ducts, on Hill / fixed on pole complete all as specified and directed. Note : Excavation & Earth work, sand cushioning, cable protection cover, pipe and joint shall be measured and paid separately under respective items of BoQ
Relay, test, joint and commission old retrieved serviceable XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric powercable heavy duty with aluminium conductor of size cross sectional area 70 Sqmm to 120 Sqmm x 3 core, 11000 Volts grade (11 KV earthed system); laid in trenches/under floor/through ducts, on Hill / fixed on pole; after rectification of defects including taking out complete all as specified and directed. Note : Excavation & Earth work, sand cushioning, cable protection cover, pipe and joint shall be measured and paid separately under respective items of BoQ
S&F in replacement of Cable straight through Jointing Kit, HT 11 KV grade, heat shrinkable, straight through type complete with jointing materials and accessories suitable for HT XLPE cable 3 core 11 KV grade of size 70 Sqmm to 120 Sqmm x 3 core armoured alumuinium conductor cablecomplete all as specified and directed. Note- Unit rate quoted by the contractor shall be deemed to inclusive of excavation and earth work, T&P and labour etc.
S&F in replacement Cable End Termination Jointing Kit, HT 11 KV grade, heat shrinkable, outdoor type complete with jointing materials and accessories suitable for HT XLPE cable 3 core 11 KV grade of size 70 Sqmm to 120 Sqmm x 3 core armoured alumuinium conductor cable complete all as specified and directed. Note- Unit rate quoted by the contractor shall be deemed to inclusive of excavation and earth work, T&P and labour etc.
S&F in replacement Pin type Insulator, Porcelain, vitreous 150mm height and 150mm dia white, brown or green colour, including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut , Frequency 50 Hz surface finish polished working voltage 11000 Volts complete all as specified and directed.
S&F in replacement Disc type Insulator, Porcelain, vitreous 145mm high and 255mm dia ball and socket type white,brown or green colour, two-in series asembly for tension with tension clamps for conductors, working pressure 11000 Volts complete all as specified and directed.
Supply, fill and top up New Transformer Oil, low viscosity type of dielectric strength not less than 50 KV into the conservator tank/body tank of the transformer/OCB/FRMUs/Voltage stabilizers etc at various locations in Chauhtan hill station complete all as specified and directed.
Filtration, heating and dehydration of old transformer oil for increasing dielectric strength not less than 45 KV, if the results below 45KV, the oil shall be replaced with new oil complete all as specified and directed. Note:- New oil required for toping oil levels or for replacement maint shall be measured and paid separately.
S&F 100mm bore galvanised pipe light grade of ISI marked with all fittings including fixing arrangements on hill (stones, etc) required to be laid on hill top chauhtan for passing of cable fixed to poles/walls/laid under floor/ laid in trenches/fixed on stones, etc. as cable protection including taking down old/unserviceable GI pipe with fittings compete all as specified and directed..
M&L for Earthing in replacement complete with copper earth plate electrode 60cm x60cm x 3.15mm thick buried directly in ground earth pit not less than 2.25m deep below ground level with top edge of plate not less than 1.5m below normal ground level ,connected to and including copper earth strip 20X3mm by means of nut, bolts, check nuts and washers made of copper alloy and connection to test point and earth dolly and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil/rock strata and testing complete all as specified and directed and shown in electrical plate number 3 of MES SSR part-I complete with the following:- (a) Excavation and earth work for drilling hole for electrode in any type of Soil/rock strata. (b) PCC chamber in cement concrete 1:3:6 type C-1, Pre-cast RCC cover with CI frame with suitable handle 50 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with 20 mm bore galvanised iron medium grade watering pipe and lugs etc complete all as specified and directed. (d) 40 mm bore galvanised iron medium grade protection pipe for protection of earthing lead and earth lead, each 7.5m long complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. Note:- Copper strip and 40mm GI protection pipe upto 7.5m each shall be deemed to be included in quoted rate of this item. (ii) If the desire earth resisitance not obtained on testing after completion, earthing shall be redone by the contractor without any extra cost upto obtain the desired resistance. (iii) Tibba sand shall be shall be used by the contractor after filling of salt and charcoal for earthing.
S&F in replacement of aluminium conductor steel reinforced (ACSR) of any size any description including stretching on over head lines on HT/ LT poles including binding the ACSR with insulators, aluminium binding wire including jumpering the over head line, jointing, etc complete all as specified and as directed.
S&F in replacement galvanised stay assembly complete with 20mm dia stay rod including stay starnd 7/4mm fixed for stay of poles including GI nuts, two numbers thimbles MS clamps made out of 50mmx6mm flat iron including MS nuts bolts and washers 300mm x 300mm x 6mm MS stay plate, stay bow of size 40cm long 16mm dia, loop type insulator including painting the exposed MS work with 2 coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Supply, erect and fix in replacement Steel tubular swaged poles with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) including taking down old unserviceable /broken PCC/Steel poles complete all as specified and directed.
Supply, erect and fix in replacement Steel tubular swaged poles with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 metres long) including taking down old unserviceable /broken PCC/Steel poles complete all as specified and directed.
Excavating in trenches in soft/loose soil, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, cesspits,manholes, pier holes, water/sewer pipe line, electric cable line etc not exceeding 10 Sqm area on plan and not exceeding 1.5 m in depth and getting out ,including taking out defective cable, sand cushion and protection cover and stacking serviceable materials for reuse and removing unserviceable from complete all as specified and directed.
Excavating in trenches in soft/loose soil, not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0 m in depth; for foundation, etc. or for shafts, cesspits,manholes, pier holes, water/sewer pipe line, electric cable line etc not exceeding 10 Sqm area on plan and not exceeding 1.5 m in depth and getting out ,including taking out defective cable, sand cushion and protection cover and stacking serviceable materials for reuse and removing unserviceable from complete all as specified and directed.
Excavating in trenches in hard rocks, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, cesspits,manholes, pier holes, water/sewer pipe line, electric cable line etc not exceeding 10 Sqm area on plan and not exceeding 1.5 m in depth and getting out ,including taking out defective cable, sand cushion and protection cover and stacking serviceable materials for reuse and removing unserviceable from complete all as specified and directed.
Excavating in trenches in hard rocks, not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0 m in depth; for foundation, etc. or for shafts, cesspits,manholes, pier holes, water/sewer pipe line, electric cable line etc not exceeding 10 Sqm area on plan and not exceeding 1.5 m in depth and getting out ,including taking out defective cable, sand cushion and protection cover and stacking serviceable materials for reuse and removing unserviceable from complete all as specified and directed.
Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Removing excavated materials (soil/rocks ) to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
M&L for plain cement concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in base foundation of poles, lean concrete, mass filling etc. complete all as specified and directed.
M&L for plain cement concrete (1:3:6) type C-2 using 40mm graded crushed stone aggregate as in foundation of poles, surrounding of poles etc. including necessary form work etc. complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in coping of poles including necessary form work etc. complete all as specified and directed.
S&F in replacement of MS Cross arms , bracing, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding , bending, cold or hot, drilling holes or bolt in any shape or size including 2 coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
S&F in replacement of HT Lightning Arrestor 12 KV, normal discharge current of 10 KA station class including jumpering, lead of wire/cable complete all as specified and directed.
S&F in replacement of Danger notice plate for LT 440 Volts of size 25cm x 15cm x 1.6mm thick mild steel sheet vitreous enameled white, with letters figures and conventional skull and bones and wtitten as "DANGER" in signal red colour and fixed with MS clamps made out of MS flat 25mm x 3mm, including nuts & bolts, including 2 coats of aluminium paint over a coat of red oxide primer all as specified. Note :- Instructions are to be written in two languages viz. -Hindi and English.
S&F in replacement of Danger notice plate for HT 11000 volt of size 25cm x 20cm x 1.6mm thick mild steel sheet vitreous enameled white, with letters figures and conventional skull and bones and wtitten as "DANGER" in signal red colour and fixed with MS clamps made out of MS flat 25mm x 3mm, including nuts & bolts, including 2 coats of aluminium paint over a coat of red oxide primer all as specified. Note :- Instructions are to be written in two languages viz. -Hindi and English.
M&L for Prunning of trees and branches along HT overhead lines, surrounding of poles/ lines, cleared upto 5m of HT line and poles in Nallah of hill top and hill base and throwing branches and out side the cantonment area complete all as specified and directed.
M&L for Prunning of trees and branches along LT overhead lines, surrounding of LT overhead electric lines, poles, surrounding LTpoles and lines and clearing upto 3m of outer edge of LT line and poles and throwing branches and out side the cantonment area complete all as specified and directed.
M&L for stone masonary walling of random rubble uncoursed well bonded, bedded and solidly hearted built in cement mortar (1:6) complete all as specified and directed.
Rasam Engg Co. (BID ID -3088095)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .