Replacement of Panel interlocking with Electronic Interlocking system at Nayandahalli(NYH), Hejjala(HJL), Bidadi(BID), Chennapatna (CPT) and Mysuru New Goods Terminus (MNGT) stations in connection with provision of Automatic signalling system in KSR Bengaluru city Jn-Mysuru section over SBC and MYS Divisions of South Western Railway.
B-SG-P-SBC-5EI-SBC-MYS-
B-SG-P-SBC-5EI-SBC-MYS-
Open
15 Months
Mysuru, Karnataka
₹0
₹23.8 L
28 Jun 2025
28 Jun 2025
Item Breakup - A-schedule-A SOR
35000.00 soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. Laying of cables is not included in this schedule. BNC-PROJECT-S AND T/SOUTH WESTERN RLY
35000.00 soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.5 Mtrs. Laying of cables is not included in this schedule.
1000.00 on the Passenger Platform, trenching to a depth of 0.6m to accommodate the additional cables, replacing the slabs removed after the cables are laid and replastering with cement mortar, refilling the trench by ramming and consolidating it as per the instructions of Railway Representatives at site. (Laying of cables is not included in this schedule). [Cement, river sand and all other miscellaneous materials required for the work shall be supplied by the Contractor].
400.00 for track crossing of cables, laying of DWC/ RCC pipes with collar/coupling, refilling of trench by ramming and consolidating it as per the instructions of Railway representative at site. During excavation of trench it has to be ensured that the excavated soil does not mix with the ballast available. The depth of 1m trench shall be from the bottom of sleepers for track crossings. Laying of cables is not included in this schedule. (Supply of DWC/RCC pipes with couplers/ collars is not included in this schedule)
250.00 for road crossing of cables, laying of DWC/ RCC pipes with collar/ coupling, refilling of trench by ramming and consolidating it and resurfacing it to the original position. Laying of cables is not included in this schedule. (Supply of DWC/RCC pipes with couplers/ collars is not included in this schedule).
8000.00 cable laying with offset at both ends and with couplings over RCC Bridges/ Drainage/ Culverts with concrete masonry supports of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site. (Supply of GI pipes with couplings and laying of cables is not included in this schedule). [Stone jelly of size 20/25mm, bricks, sand, cement and all other miscellaneous materials required for the work shall be supplied by the Contractor]. BNC-PROJECT-S AND T/SOUTH WESTERN RLY
1000.00 cable laying with offset at both ends and with couplings over girder bridges by fixing on suitable MS Clamps at an interval of 2 Mtrs. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site. (Supply of GI pipes with couplings and laying of cables is not included in this schedule). [MS angles, flats, bolts and nuts for manufacturing fixing clamps, bricks, river sand , cement and all other miscellaneous required for the work shall be supplied by the Contractor].
3000.00 cable laying in hard rocky area with off sets at both ends duly supported by concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site. (Supply of GI pipes with couplings and laying of cables is not included in this schedule). [Stone jelly of size 20/25mm, bricks, sand, cement and all other miscellaneous materials required for the work shall be supplied by the Contractor].
of Metre signaling/power/telecommunication cables as per cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc. (Supply of cables is not included in this schedule).
35000.00 0.3m width throughout, with earth after laying of cables, and consolidating the trench by ramming and leveling.
35000.00 0.5m width throughout, with earth after laying of cables, and consolidating the trench by ramming and leveling.
2300.00 drawing No.CSTE/CN/OFC/1. The lettering on the cable marker shall be "SIG" / "TELE" / "OFC" as per the instructions of Railway representative at site.
2300.00 size 300mmX300mm, casting of concrete foundation of size 300mmX300mmX300mm and Placing of RCC cable markers on top of the foundation and refilling the pit and consolidating it by ramming. The cable markers shall be provided at an interval of 20 Mtrs. within station limits and 50 Mtrs. outside station limits throughout the cable route, diversions and also at every track/road crossing. BNC-PROJECT-S AND T/SOUTH WESTERN RLY
30.00 1.5mx1.5m and depth as instructed by Railway representative at site, for coiling the cables in rear of relay rooms/ AFTC huts, apparatus cases etc. The work includes coiling the underground cables, and placing closely one layer of country bricks of size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and leveling. [Country bricks of size 220mmx100mmx60mm (approximately) shall be supplied by the Contractor].
12000.00 thick as specified in Vol.II of the Tender document
200.00 foundation and erection of apparatus case full size as per Drg. No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door and another for the back door, fixing of one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints. (Supply of apparatus case is not included in this schedule). [Foundation bolts & nuts, 'E' type locks, cement, river sand, stone jelly of size 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required for the work shall be supplied by the Contractor.]
160.00 foundation and erection of apparatus case half size as per Drg, No.SG/CN/02/7, fixing one 'E' type lock for the front door and latching arrangement for the back door, and fixing of one hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints. (Supply of apparatus case is not included in this schedule). [Foundation bolts and nuts, cement, 'E' type locks, river sand, stone jelly of size 20/25mm, 37mm hard wood planks, latching arrangements, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required for the work shall be supplied by the Contractor] BNC-PROJECT-S AND T/SOUTH WESTERN RLY
3.00 termination boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia and 300mm long at the bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each pipe for cable entry and one GI pipe 150mm long 32mm dia for drawal of jumper wires for Point machines etc., fixing of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside and outside with one coat of red-oxide and two coats of aluminium paints. (Supply of CT boxes is not covered in this schedule. Rails of different length shall be supplied by Railways. The contractor shall cut lengthy rails wherever required.) [Cement, river sand, stone jelly of size 20/25mm, paint, varnish , GI Pipes 32mm dia - 300mm long - 2 Nos and 150mm long - 1 No., clamp nuts - 12mm thick - 2 Nos. for each pipe, fixing bolts and nuts with washers, EWS locks, paints and all other miscellaneous materials shall be supplied by the Contractor]. Excavation of pit in and around the existing location boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringement as instructed by the Railway representative at site. The work includes ensuring the safety of the signaling system, releasing the cable coils to give access for shifting/turning the location boxes. Necessary masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site. If the existing earth connections to the location boxes are disturbed, the earth wires shall be properly re-connected. [All materials required for the work shall be supplied by the Contractor].
200.00 the existing terminals/ fuse blocks in apparatus cases/ battery boxes/ CT boxes/ cable termination racks as per approved circuit diagram. The terminal particulars are to be repainted /corrected on the doors of apparatus cases/ battery boxes/ cable termination boxes and FTOT index board as instructed by Railway representative at site. This work includes closing the opening created for entry of new cables in the apparatus cases with masonry brick work and sealing the bottom of the apparatus cases/ cable termination racks with cable compound. [Paints, wire PVC 3/0.75mm and 16/0.2mm copper, sealing compound, bricks, cement, river sand and all other required miscellaneous materials shall be supplied by the contractor]. {Unit: Per Terminal Block} BNC-PROJECT-S AND T/SOUTH WESTERN RLY Termination of main, tail, Signaling and power cables and internal wiring on terminal/ fuse blocks in new apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks on the terminal board, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter- space filled with river sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and Fuse blocks is not covered in this schedule). [Cement, teakwood cable clamp 50mm x 50mm, base planks 100mm x 25mm, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, PVC/Nylon sleeves, varnish, paints, bolts, nuts and washers, Nondeteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm x 100mm x 60mm, copper bus bars, brass screw, river sand, wire PVC3/0.75mm copper and other miscellaneous materials shall be supplied by the Contractor].
1500.00 (new location)(Phynolic sheet) {Unit: Per Terminal Block}
500.00 location) (Phynolic sheet) {Unit: Per Fuse Block} BNC-PROJECT-S AND T/SOUTH WESTERN RLY Termination of main, tail, Signaling and power cables and internal wiring by fixing additional terminals/ fuse blocks on the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter-space filled with river sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and Fuse blocks is not covered in this schedule). [Cement, teakwood cable clamp 50mm x 50mm, base planks 100mm x 25mm, PVC/Nylon sleeves, varnish, paints, bolts, nuts and washers, Non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm x 100mm x 60mm, copper bus bars, brass screw, river sand, wire PVC3/0.75mm copper and other miscellaneous materials shall be supplied by the Contractor].
100.00 terminals (existing location) {Unit: Per Terminal Block}
50.00 (existing location) {Unit: Per Fuse Block} Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type HMU as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars. (Supply of all types of relays, plug boards, connectors, retaining clips and plug in type HMU is not covered in this schedule). [Wire PVC copper, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor]. BNC-PROJECT-S AND T/SOUTH WESTERN RLY
60.00 (up to 4 relays/Plug in type HMU)
24.00 (up to 8 relays/plug in type HMU)
70.00 foundation as per Drg.No.SG/CN/02/9 using metallic templates, for erection of colour light signals up to 4 aspects. [Foundation bolts, cement, river sand, stone jelly of size 20/25mm dia and all other miscellaneous materials required for the work shall be supplied by the Contractor].
70.00 mounting of colour light signal up to 4 aspects complete on Signal pole/ Off-set bracket, (for LED/ filament bulbs) with lenses, triple pole lamp holder, filament switching units, CLS transformer, current regulators (whichever is applicable), fixing of ladder with platform complete and concreting of ladder shoe, fixing of number plates, marker board, lens guard, fixing of speed limit board wherever necessary, termination of tail cables, wiring of signal unit with PVC wire 3/0.75mm copper, provision of EWS locks, and painting of one coat of red oxide and two coats of aluminium/ enamel paints. When the aspect is fixed on Offset bracket using 'U' bolts and nuts, a through bolt shall be provided by drilling a hole in the signal pole to prevent the offset bracket from sliding down. (Supply of surface base, Offset bracket, CLS pole, CLS aspects complete, ladder with shoes and platform, Speed limit board, LED aspects, current regulators, lamp holders, lamps, filament switching unit and CLS transformer is not covered in this schedule). ['U' bolts and nuts, through bolts and nuts, cement, stone jelly 20/25mm dia, river sand, Signal Collar Rings, wire PVC 3/0.75mm copper, lens-guard, all fixing bolts and nuts, lead wool, paints PVC/Nylon sleeves, enameled number plates. enameled marker boards, EWS locks, and all other miscellaneous materials for the work shall be supplied by the Contractor].
15.00 foundation as per Drg, No.SG/CN/02/10 using metallic templates, for erection of ground type colour light shunt signal. [Foundation bolts and nuts, cement, river sand, stone jelly of size 20/25mm and all other miscellaneous materials for the work shall be supplied by the Contractor]. BNC-PROJECT-S AND T/SOUTH WESTERN RLY
15.00 complete including surface base, signal pole, LED aspects/ lenses, bulbs with holders (whichever is applicable), fixing of lens guards, number plate, termination of tail cables, wiring of signal unit with PVC wire 3/0.75mm copper, provision of EWS locks and painting of one coat of red oxide and two coats of Aluminium/ enamel paint. (Supply of Ground type shunt signal complete including surface base, signal pole, LED aspects, holder, bulbs, and lenses is not covered in this schedule). [Wire PVC 3/0.75mm copper, lens guards, EWS locks, Enameled number plates, bolts and nuts, lead wool, paints and all other miscellaneous materials shall be supplied by the Contractor].
18.00 and nuts, erection of Post type shunt Signals, termination of tail cables and wiring using wire PVC 3/0.75mm copper, provision of EWS lock and painting of one coat of redoxide and two coats of aluminium/ enameled paint. The work also includes drilling suitable holes on the CLS post and provision of a through bolt with nut to prevent the Off-set bracket from slipping down. (Supply of Post type Shunt Signals, LED aspects and Off set brackets is not covered in this schedule). ['U' bolts and nuts, through bolts with nut, wire PVC 3/0.75mm copper, EWS lock, Enameled number plates, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the contractor]. Fixing of junction type route indicators - 1 way to 6 ways - complete/ fixing of additional limb to the existing route indicators, termination of tail cables, wiring as per approved circuits diagram using wire PVC 3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting. (Supply of junction type Route Indicators - complete and additional limb is not covered in this schedule). [3/0.75mm wire PVC, fixing bolts and nuts, EWS locks, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor].
5.00 indicator - 1 way
4.00 indicator - 2 way
1.00 indicator - 3 way BNC-PROJECT-S AND T/SOUTH WESTERN RLY
24.00 and nuts, erection of Calling On Signals/ 'A' marker lights, termination of tail cables and wiring using wire PVC 3/0.75mm copper, provision of EWS lock, number plates/ marker boards and painting. The work also includes drilling suitable holes on the CLS post and provision of a through bolt with nut to prevent the Offset bracket from slipping down. (Supply of Calling On Signal/ 'A' marker light, LED aspects/holders & bulbs and Off set brackets is not covered in this schedule). ['U' bolts and nuts, through bolts with nut, wire PVC 3/0.75mm copper, EWS lock, Enameled number plates, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the contractor].
100.00 drawal of new tail cables for colour light signals up to four aspects with or without route indicator, post type shunt signal and Calling on signals, termination of new tail cables and wiring using wire PVC 3/0.75mm copper. This work includes drawal of new tail cables into the signal post duly releasing the existing tail cables from the relevant signals and re- surfacing the earth excavated as instructed by Railway representative at site. [Wire PVC 3/0.75mm copper, paints and all other miscellaneous materials shall be supplied by the Contractor]. {Unit: Per Cable}
60.00 new CLS units with LED aspects/ lamps, holders etc., up to four aspects, directly or using off set brackets duly drilling holes on the signal poles, provision of EWS locks wherever necessary, termination of tail cables and wiring using wire PVC3/0.75mm copper and painting of aspect. The new tail cables shall be taken through the signal poles and the unwanted cables duly released. (Supply of CLS unit with LED aspects/ lamps holders, CLS transformers is not included in this schedule.) [EWS locks, Wire PVC 3/0.75mm copper lenses guard, wire netting arrangements, paints and all other miscellaneous materials shall be supplied by the Contractor].
8.00 arrangement for Signals in RE area as per standard practice. The work comprises of providing MS angle frame and wire mesh in order to avoid close proximity of OHE wires. The work also includes provision of earthing wire using 4 SWG GI wires from the screening arrangement up to surface base as per the instructions of Railway representative at site. [All materials required for this work shall be supplied by the Contractor]. BNC-PROJECT-S AND T/SOUTH WESTERN RLY Provision of DC Single/ Double rail track circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 Nos for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, B type choke and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.) (Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, B type choke, track relays, uncharged secondary cells (2V - 80AH), TLD boxes with stumps, 2cX2.5 sq.mm cable, is not covered in this schedule). [track feed resistance, Gauge tie plate and nose crossing plate insulations, PVC/Nylon bushes for TLD boxes, PVC sleeves, all types of fixing bolts and nuts with spring and flat washers, teakwood stand for fixing track feed resistance, GI bond wire 8 SWG, Channel bond pins, bond wire clips, paints and all other miscellaneous materials shall be supplied by the contractor. Secondary cells-80 AH capacity shall be charged by the contractor through reputed charging agencies].
100.00 point zone) BNC-PROJECT-S AND T/SOUTH WESTERN RLY
400.00 drawing No.SG/SN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, ASM room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, river sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor].
60.00 machine - IRS type and connecting all ground connections including wiring and termination in point machine and interconnections between point machine and CT box through PVC hose pipe with 3/0.75mm and 7/1.40mm copper wire and painting. This work includes provision of insulation to stretcher bars, throw bar lug and "D" bracket wherever required, cutting of notches on the point machines covers to suit crank handle configuration. (Combined type point machine with ground connection, uninsulated stretcher bar, throw bar lug and 'D' brackets will be supplied by Railways. [All types of insulations connected to point work, coal bengal, all type of bolts and nuts, washers spring/flat wire PVC 7/1.4mm copper, PVC hope pipe, paints, PVC/nylon sleeves and all other miscellaneous materials required for the work shall be supplied by the Contractor]. Supply of Colour light Signal pole 140mm dia, 4.6m/ 3.6m tall with necessary inspection as per specification/ drawing/ description enclosed in this document.
65.00 pole 140mm dia with necessary inspection as per specification/ drawing/ description enclosed in this document. Supply of ladder with platform and shoes to suit CLS pole 4.6m/ 3.6m tall, with necessary inspection as per specification/ drawing/ description enclosed in this document.
5.00 for 4.6m CLS pole
65.00 for 3.6m CLS pole BNC-PROJECT-S AND T/SOUTH WESTERN RLY
18.00 complete with hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document.
15.00 complete with surface base, signal pole, hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document. Supply of Colour Light Signal Multi Unit type - complete for 4/ 3/ 2 aspect with mounting socket, with necessary inspection as per specification/ drawing/ description enclosed in this document.
24.00 aspect Supply of Junction type route indicator - 5 unit arm - 1/ 2/ 3/ 4/ 5/ 6 way with mounting sockets, with necessary inspection as per specification/ drawing/ description enclosed in this document.
1.00 17732.00 3 way Supply of Calling On Signal / 'A' marker light - complete with necessary inspection as per specification/ drawing/ description enclosed in this document.
Numbers Supply of Off-set brackets - large/ small made of cast iron with necessary inspection as per specification/ drawing/ description enclosed in this document.
Numbers Supply of PBT terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection as per specification/ drawing/ description enclosed in this document.
500.00 fuse) Supply of Low maintenance secondary cells of the following capacities with necessary inspection as per specification/ drawing/ description enclosed in this document.
secondary capacity Supply of apparatus cases (full/ half/ quarter size) to suit Southern Railway standard with necessary inspection as per specification/ drawing/ description enclosed in this document:
Numbers BNC-PROJECT-S AND T/SOUTH WESTERN RLY
150.00 boards, connectors and retaining clips with necessary inspection as per specification/ drawing/ description enclosed in this document.
150.00 boards, connectors and retaining clips with necessary inspection as per specification/ drawing/ description enclosed in this document.
10.00 type of required ward Nos. with keys, with necessary inspection as per specification/ drawing/ description enclosed in this document.
150.00 per specification/ description enclosed in this document.
300.00 specification/ description enclosed in this document.
500.00 blocks with 2BA terminals, and wiring of relays as per the approved circuit diagram using wire PVC 16/0.2mm copper. Suitable wire supporting tray with cover made of PVC shall be provided horizontally and vertically in the relay racks.. While running the wires on the aluminium ladder proper care shall be taken to provide smooth materials like rubber beading in the openings on Phynolic sheets, to avoid damage to wires. The work also includes wiring of contacts for data logger and terminating them in tag blocks, provision of relay index board. (Supply of relays, plug boards, connectors and retaining clips is not covered in this schedule). [Wire PVC 16/0.2mm copper, tag blocks, 2BA terminals, hard wood plank of size 600mmx 900mmx25mm with decolum finish, MS angles of size 25mmX25mmX6mm, relay fixing bolts and nuts, teakwood plank 25mm thick for fixing resistors and condensers, phynolic sheet 6mm thick of size 1200mmX1800mm with aluminium grooved channel frame for relay index board, paints, soldering materials, bunching thread, wire wound resistance, condenser, wire supporting tray with cover of suitable size made of PVC, paint, varnish and all other miscellaneous materials required for the work shall be supplied by the Contractor]. BNC-PROJECT-S AND T/SOUTH WESTERN RLY
200.00 terminal blocks and wiring of additional relays as per the approved circuit diagram using wire PVC 16/0.2mm copper. Additional wire supporting tray with cover made of PVC shall be provided wherever required. Alterations to Relay particulars shall be incorporated in the relay Index board. (Supply of relays, plug boards, connectors and retaining clips and 50 way terminal boards is not covered in this schedule). [Wire PVC 16/0.2mm copper, 2 BA terminals, teakwood plank 25mm thick for fixing resistors and condensers, soldering materials, bunching thread, wire wound resistance, condenser, wire supporting tray with cover of suitable size made of PVC, paint, varnish and all other miscellaneous materials required for the work shall be supplied by the Contractor ) Provision of Interconnections between relay racks, cable termination racks, SM's control panel, battery room, power room, termination and wiring. The work involves laying of underground cables in the duct as well as with clamping arrangements on the walls, supply and fixing of aluminium ladders and supports with 3mm thick phynolic sheet for running the cables in the relay room. Interconnection shall be carried out with signaling multi core cable (skinned/ unskinned) and power cables as per the instructions of Railway representative at site. The work also include termination of the interconnection cables on 50 way terminals in the relay rack/ control panel, cable termination rack etc. After the interconnection cables are laid, the ducts shall be filled with river sand and closed. Wherever required the cables shall be taken to other floors in the building by clamping them on MS angles and flats grouted on the walls. (Supply of interconnection cables is not included in this schedule). [2BA terminals, Aluminium ladder arrangements using 37mmx37mmx5mm aluminium angles and 25mmx6mm aluminium flats, aluminium supports, phynolic sheet - 3mm thick for bottom of aluminium ladders, MS angles and flats, bolts and nuts, concreting materials, and all other materials required for the work shall be supplied by the contractor].
5.00 41768.15 (up to 5 roads). BNC-PROJECT-S AND T/SOUTH WESTERN RLY Installation of charged secondary cells of the following capacities in apparatus cases, connecting them with strips, wiring with wire PVC 3/0.75mm copper and termination. This work also includes charging of cells through reputed agencies. The details of the batteries shall be written on the inside of the doors of the apparatus cases. (Supply of secondary cells is not included in this schedule). [Wire PVC 3/0.75mm copper, connecting strips, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor].
in Per Unit apparatus case {Unit: per Cell}
400.00 not less than 6mm thick and with an Foot insulation to withstand 650VAC, on the floor of relay room etc at places as indicated by railway representative at site.
5.00 18178.95 during Non- Interlocked working of Signals and Points, such as erection and wiring of temporary relay racks and wiring of relays, SM's slide instruments, wiring alterations in the cable termination rack, apparatus cases, signals, Control panel etc, as per the instructions of Railway representative at site. (Supply of relay rack, relays, and SM slide instrument is not included in this schedule). [All other miscellaneous materials required for the work shall be supplied by the Contractor].
10.00 telephone communication at stations/ tents as per the instructions of Railway representative at site. The PA system and magneto telephones will be returned to the contractor after the completion of NI working. Signalling cables available may be used for the communication. (Hiring of PA system equipments and magneto telephones shall be done by the Contractor) [All other miscellaneous materials required for the work shall be supplied by the Contractor].
10.00 the same at places as instructed by Railway representative at site. The spacing inside the tent shall be app 8ft x 8 ft. Each tent shall be provided with a table, chair, tube lights and pedestal fan. Drinking water in cans. The tents shall be fixed firmly to withstand rain, strong wind etc. {Unit: per Tent per Day}
10.00 fronted box of size 300mm x 600mm x 75mm with hooks to keep various keys with description engraved on the tags. [TW Glass fronted box of size 300mmx600mmx 75mm with built in lock, hooks, engraved tags and all other miscellaneous materials required for the work shall be supplied by the Contractor]. BNC-PROJECT-S AND T/SOUTH WESTERN RLY
2.00 without crank handle or on suitable fixtures at station/apparatus case, provision of economiser push switch with locking facility, wiring with wire PVC 16/0.2mm copper, provision of teakwood terminal box covered with decolum along with locking facility and painting. (Supply of electric key transmitter and crank handles is not covered in this schedule). [wire PVC 16/0.2mm copper, wire wound resistance, decolum covered terminal box with locking facility by using 25mm thick teakwood, bolts and nuts, paints, push switches, padlocks and other miscellaneous materials required for this work shall be supplied by the contractor].
10.00 and painting of boards with LEGEND such as //Draw close if signal is at on// at the required places as per the Signalling plan. The work involves concreting of rail post to a size of 600mm x 600mm x 900mm, and fixing the board to the rail using MS clamps, bolts and nuts. (Supply of boards is not covered in this schedule. Rails of different lengths will be supplied by Railways and the Contractor has to cut them to the required lengths) [Stone jelly of size 20/25mm dia, river sand, cement,M.S.flats, fixing bolts and nuts, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor].
5.00 diagram board in the station master's room. The board shall be made of Phynolic synthetic industrial fibre base fine weave cotton fibre board (matt finish) 6mm thick size 1800mm X 1200mm with aluminium channel frame. The yard layout shall be neatly painted and fixed as instructed by Railway representative at site. [All materials required for the work shall be supplied by the Contractor]. Testing and commissioning the entire signalling installations jointly with the Railway representative at site at the stations/ LC gates covered under various schedules of the Contract, and ensuring that all the signalling gears are installed and adjusted as per the existing rules. The work also involves supply of required number of bound registers with good quality papers with all updated details of cable meggering, relays, batteries, block joints, route cancellation, relay room key entries, block instrument key, earth resistance etc., and handing over to Railways. (Supply of 'As mades' is not covered in this schedule).
5.00 21018.75 (upto 5 roads) BNC-PROJECT-S AND T/SOUTH WESTERN RLY
2000.00 of circuit diagrams, contact analysis charts, termination particulars of apparatus cases and cable termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All AS MADEs shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the AS MADEs check print shall be submitted before Testing the circuits. The final negatives shall be made in tracing sheet (80 to 90 gsm). All AS MADEs except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back to back in one plastic cover) and handed over to Railways. Also the contractor has to supply one set of AS MADEs in Reproduction Film . The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing AS MADE circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incorporate the details of all the new wirings and alterations in the CD/ RP film and submit them to Railways. On approval 8 copies shall be made for AS MADE circuit diagrams also as mentioned above.
10.00 termination racks along with all the terminals, fuse blocks, relays, with jacks, holding clips etc., 50 way boards, terminals, connecting wires, cables etc., carefully without causing any damage, accounting and stacking them neatly at a place as instructed by Railway representative at site. After releasing, the floor shall be levelled and cement plastered. {Unit: per Rack}
10.00 different types including tail cables, carefully without causing any damage, accounting and stacking them neatly at a place as instructed by Railway representative at site.
16.00 STOP board/Warning board/ LEGEND boards along with rails, accounting and stacking them neatly at a place as instructed by Railway representative at site. Also the resultant pits shall be re- surfaced and consolidating by ramming and levelling. BNC-PROJECT-S AND T/SOUTH WESTERN RLY
of single/double along with switch extension pieces, stretcher bars, point/ trap indicators and other fixtures carefully without damaging the materials, accounting and stacking them neatly at a place as instructed by Railway representative at site.
60.00 (Full/ Half/ Quarter size) without damage after releasing the shelf planks, Terminal blocks, Fuse Blocks, Terminal Boards, Relays of all types EKTs, Secondary Cells, power equipments, 'E' type locks, etc., and breaking the concrete foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. The released materials shall be accounted and stacked at a place as instructed by Railway representative at site.
2.00 existing cable termination boxes, after releasing the base plank, Terminal blocks, Fuse Blocks, Terminal Boards, cut rails, pipes, etc., closing the resultant pits and consolidating it by ramming and levelling. The released materials shall be accounted and stacked neatly at a place as instructed by Railway representative at site.
5.00 including base plank, and other gadgets connected very carefully without causing any damage to the panel, acounting and stacking them neatly at a place as instructed by Railway representative at site. The resultant pit in the flooring shall be removed of all cable bits, levelled and cement plastered.
65.00 Colour light Signals complete (upto 4 aspects) with or without Route Indicators, calling on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work includes breaking the concrete foundation, closing the resultant pit and resurfacing it by ramming and levelling.
50.00 Point machines (all types) including ground connections and other accessories available complete without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site.
10.00 (all types), Block counters, batteries, block filter, block bell equipment etc., carefully without any damage, accounting and stacking them neatly at a place as instructed by Railway representative at site. BNC-PROJECT-S AND T/SOUTH WESTERN RLY
10.00 signals along with surface base, signal post etc carefully without any damage, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work also includes breaking and removal of concrete foundation and refilling of the resultant pit by ramming and levelling.
150.00 stumps and terminals after releasing all the bond wires. The released materials shall be accounted and stacked neatly at a place as instructed by Railway representative at site.
5.00 including equipment stands, terminal boards, power panel etc., in the power room carefully without causing any damage to the equipments after disconnecting all the supply wires. The released equipments shall be accounted and stacked at a place as instructed by Railway representative at site. After releasing any holes in the walls/ flooring shall be filled with cement mortar and plastered.
5.00 - complete including way station equipments, telephones, power supply for way station equipment and telephones, along with all wiring, accounting and stacking them neatly at a place as instructed by Railway representative at site. Transportation of Signalling materials by road as per the instructions of Railway representative at site. The work also includes loading and unloading of the materials.
20000.00 Ton per KM}
100 {Unit: per Ton per KM}
200.00 or other machineries for regarding and levelling the formation, dismantling any infringing structures, clearing and removing debris etc., with all leads and lifts etc., complete and as per the instruction of Railway representative at site. Total 40618493.82
Item Breakup - B-SOR SUPPLY ITEMS
15.00 Meters made out of 50mmX50mmX6mm thick MS angle POWDER COATED with stainless steel nuts and bolts for fixing the racks with suitable holes for hylem sheet complete as per standard practice with tripod bases and reel insulators. Cable ladder of 400mmx2000mm be provided at both sides with angle size 40mmx4mmx5mm with supporting flat of size 25mmx5mm. BNC-PROJECT-S AND T/SOUTH WESTERN RLY
1500.00 Centre, made up of PBT as per RDSO Drg.No. SA. 23756/ Adv/Alt.3, confirming to Specification No. IRS.S.75/2006 (Rev.2) or latest.
4000.00 of 110 mm Outer Dia, 10 mm Wall Thickness, along with one coupler for every 6 Meters as per specification No. IS 4984: 2016 with latest amendments and Material Grade:PE 80.
material to Maintenance Free Earth as per RDSO Spec No. RDSO/ SPN/197/2008 or latest and as per relevant Technical specification
for Metre interconnecting earth electrodes
600.00 insulated Copper Cable as per IS: 694 for connecting Main Earth Electrode to MEEB in the equipment room. Color: Green
800.00 insulated Copper Cable as per IS: 694 for connecting MEEB to SEEB and SPDs to MEEB. Color: Green
800.00 insulated Copper Cable as per IS: 694 for connecting SEEB to all equipments. Color: Green
lightening system consisting of Franklin rod of 16mm dia, single prong spike made of copper of length 600mm. Appropriate reducer/coupler for connecting Franklin rod and GI mast, GI mast approximately 1.5 inch dia, 6 mtr length with flanges for installation of franklin rod with all supporting accessories, such as guy rope, U-bolt, thimble, adjustable clamp, D-shakle, hook etc.
5.00 131287.00 Channels- 110V AC, 2 Channels- 110V DC , 6 Channels- 24V DC) as per RDSO Spec./256/2002 or latest with 6 digit counter.
5.00 22719.00 well/slimline 4S )
5.00 make or better of App. 5 feet height.
700.00 various drawing with Colour (Power Foot board diagram,Relay index chart,Station Rule Diagram, FTOT Particulars, etc), as per instructions of Site In-Charge Railway Representative.
100.00 maintanance registers for SSDAC, point machine, track circuit etc. (100 Pages each of 75 gsm paper)
75.00 30(a)(i)) BNC-PROJECT-S AND T/SOUTH WESTERN RLY
120.00 Polyethylene Duct (PLB-HDPE), 40/33 mm Dia, along with End Cap, End Plug, Cable Sealing Plug and Couplers, as per RDSO/SPN/TC/45/2013 Rev.2 (upto Amdt.2) or latest
50.00 specificaiton No.IRS-TC 77/2006 Revision1 or latest for quad cable. Total 18362619.00
Item Breakup - C-EXECUTION SOR-ITEMS)
15.00 suitably concreting tri-pod bases and reel insulators with "J" bolts and nuts. Tripod and other supporings are to be painted in 2 coats with enamel.
2500.00 Method based on RDSO Report No. BS - 105. This also includes insertion of HDPE Pipe of 110mm Outer dia in the Bore drilled.(Supply of HDPE Pipe is not included).
2500.00 power cables and internal wiring on terminal/ fuse blocks in cable termination Rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of Hylem sheet 10 mm thick for terminal board , varnishing all teakwood items, fixing of terminals/ fuse blocks on the terminal board, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves . After terminations are over, cable entry at the bottom shall be closed with , cement plastered, the inter-space filled with sand upto base level and the bottom surface shall be sealed with sealing compound. Cable armour to be soldered to earth. (Supply of cable termination racks is not included in this schedule). [All bolts and nuts with washers, Hylum Sheet 10 mm Thick, cement, sand, stone jelly, Teak w o o d base , p a i n t s a n d all other miscellaneous materials required for the work shall be supplied by the contractor]a. Termination on 25/60mm PBT terminals {Per Unit-Per Terminal}
80.00 parallel at a separation of 8 cms each to a depth of 150 mm in the platform surfaced/tiled floor for laying cable.
400.00 10mm Thickness along with collars in trenches at places of platform cutting etc., and wherever required as per the instructions of site engineer. BNC-PROJECT-S AND T/SOUTH WESTERN RLY
1000.00 GI pipe/DWC/HDPE pipe in which cable is already laid to a size of 300*300mm with 1:3:6 mortar. (All the matetrials required for the work should be supplied by the contractor){Per Unit- RMT}
80.00 Earth Pit as per RDSO specification No.RDSO/ SPN/197/ 2008 or latest and as per Technical Specification
5.00 14360.00 protection system consistng of Franklin rod, appropriate reducer/coupler, flanges and GI mast with all supporting accessories such as guy rope(6 mm GI wire),U-bolt ,thimble, adjustable clamp, D-shakle, hook etc.
of Numbers Earth Leakage Detector 12 channel .
5.00 and termination of cables on Wago/krone connectors as per the instructions of the site Engineer.
5.00 disconnecting terminals of wago/phonix/elmex make or similar and termination of cable at the station/LC gates etc. This includes fixing of Quad/PIJF cables and CT box on the wall.
40.00 Shrinkable type complete for 6 quad cable. After the jointing the through cable has to be tested for insulation resistance and loop resistance in presents of Railway Engineer and in case of any defects the jointing has to be done at free of cost by the contractor. [Heat Shrinkable jointing kit conforming to RDSO specificaiton No.IRS-TC 77/2006 covered in the supply portion has to be used for this purpose. The Contractor should supply all other small items free of cost which are required for making a joint. Only gas blower to be used for blowing
900.00 clock in 12 hours shift beat from Up Home Signal to Down Home Signal to avoid theft of signalling assets.{Per Unit- Per 12 Hours shift} Total 8694030.00
Item Breakup - D-Supply & installation ( SOR-Items)
5.00 98035.00 Core Plan, Cable Termination Rack Particulars, Location Box Particulars, Power Supply Diagram, Track Circuit Bonding Diagram and/or any other drawing on Auto- CAD in A2/A3/ A4, etc. size (as per instructions of Engineer in- charge). Initially Contractor shall submit 2 sets of 'AS PLANNED' documents complete for approval of Railways. One set is returned either duly approved for making a fair copy or for re-submission for approval after incorporating the changes as required by railways. After preliminary approval, execution of work shall be carried out at site. After Completion of work, 2 sets of 'AS MADE' Check Prints are submitted for Administarative approval. Railways will return one set to the contractor duly approved with alterations/corrections if any. The contractor shall incorporate Railways alterations/corrections in the tracings without any deviation and submit all tracings complete in all respect along with its soft copies in USB Pen Drive and 6 sets of final completion drawings in properly bound booklets. [For Centralized Electronic Interlocking Stations/Small Stations]
5.00 48844.00 Distribution Panel for IPS using Hylem sheet 10 mm as per site requirement and erecting it using MS angle clamp 65mm X 65mm X 8mm, HRC fuse block, Mains control switch, ammeter by-pass switch, voltmeter, ammeter, PBT terminals 60mm and wiring the same using wire PVC 7/1.40mm as per approved power diagram. This also includes termination of power cables using teakwood clamp of size 25mm X 60mm X 150mm on a base plank of 25mm thick 150mm width. (MS angles 65mm X 65mm X 8mm, Hylem sheet of 10 mm Thickness, as per site requirement, bolt and nuts required for manufacture of power panel, HRC fuses, box and carriers, teak wood clamp, wire 7/1.40mm, PVC casing and capping and all other miscellenous materials will be supplied by the contractor, Supply of PBT terminals 60mm is not included in the schedule.)
10.00 Goods Warning Boards as per practice & SEM(Angle/Rail is to be supplied by Railway).
10.00 Calling-On/STOP/BSLB/Legend boards as per practice & SEM (Angle/Rail is to be supplied by Railway). BNC-PROJECT-S AND T/SOUTH WESTERN RLY
30000.00 channel of size, Width 240/340 mm, Height 155/230 internal/external, length 1 m produced of polyolefin with Fire protection class k-1 in accordance with DIN-53438 Part II for laying Signalling/Telecom cables, channel attachable to each other with male- female swallow tail connectors and having suitable detachable cover
42500.00 Capping (RCC Duct) of 500mm Width as per Drg. No. SDO/Cable laying/ 007 (Annexure-10), as detailed in document No. RDSO/SI/G/2010 Ver.1.1 or latest on 'Guidelines on signalling cable laying'
20.00 Crank Handle Cum Key Lock Relay Box (of MS Sheet) along with LEDs, with approved type push buttons, Wago or similar Disconnecting type Terminal Blocks inlcuding DIN rail etc., as per tentative drawing enclosed. Installation, fixing and wiring of boxes for Key Lock Relays to be carried with Contractor's wiring and fixing material. The work shall be carried as per the instructions of site engineer.
250.00 capping/PVC pipe of minimum 25 mm size or higher as per requirement at site on the wall/floor etc., using bends, coupler and T joints and flexible pipe wherever necessary with fixture in the OFC room from equipment rack to common termination and from OFC room to SM room/Reservation office /Data logger/FOIS room etc. (All required material for fixing to be arranged by the contractor) Total 131526755.00
A-schedule-A SOR
B-SOR SUPPLY ITEMS
C-EXECUTION SOR-ITEMS)
D-Supply & installation ( SOR-Items)
E-EI-New Electronic Interlocking at NYH,HJL,BID,CPT and MNGT
Supply of Electronic Interlocking excluding Panel Processor (Hot Standby) for stations with Signaling functions up to 125 units as per Function table enclosed along with 15% spares, tools, 1 manuals and Instruments. EI to be provided as per RDSO Spec No.RDSO/SPN/192/2005 or latest with dedicated port with allocation of bits for direct KAVACH interface. This includes supply of Maintenance VDU and Maintenance PC(embedded PC) and all types of indoor relays along with point contactor relays(QBCA1) required for points/other indoor purposes.(Ref : Technical specificatons/explanatory note in the tender document).
Incremental rate for signaling functions in EI SYSTEM over and above 125 functions under item-1 above. (Per unit = per function).
ELECTRONIC INTERLOCKING-EXECUTION-Installation, Wiring, testing, Soldering of all EI equipments, earthing of EI Equipment, Relay Racks and Power Equipment etc. including supply power cable and Documents/Manuals etc., (Per unit= per EI).
ELECTRONIC INTERLOCKING-EXECUTION-Commissioning of Electronic Interlocking system.
ELECTRONIC INTERLOCKING-DESIGN AND DRAWING WORK- Design and Drawing for complete indoor signalling work for new EI station (Per unit= per EI).
Tool set for wheel sensor mounting and maintenance of MSDAC consisting of torque wrench, ratchet, testing plate, measuring tape, screw driver, and gloves and multi meter fluke 115
G-Non SOR (Telecom Items )
Supply and installation of covered 19" 42 U racks of size 600mm depth Telecom Rack with Standard Accessories (Closed type Telecom Rack) with front door Glass type, all Doors[Detailed Specification in Technical Document].
Supply and Installation of Rack mountable 48 Fibre management system (FMS) conforming to RDSO/SPN/TC-3712000(rev-3) amdt-1 or latest similar to COMSCOPE make or better, suitable forsplicing and front patching 48F cable with all accessoriesand terminating the optical fibre cable with splicing andfront patching in FMS in the equipment room . (OFC Pigtail patch chords ofsuitable length and all other materials required for splicing are to be supplied by contractor).
Supply, fixing and termination of 24F FDMS 19" Rack Mount with Telescopic type loaded with SC '0' DB & Adaptor SC SM Pigtail 1.5 meters all accessories required for installation [Detailed Specification in Technical Document].
Supply and installation of OFC Joint closure conforming to TEC Spec. and splicing of Optic Fibre Cable' (48 Fibres) and testing of fibre for 1310 :1550 nm.
Supply and Installation Testing and Commissioning of Isolated DC-AC Inverter 1+1 HA input 48 V DC, Output:220V AC 1000VA or higher, with all required Protection Circuits.
Supply and fixing of PVC Conduit Pipe minimum 35 mm Dia ISI Mark. Installation of PVC Pipe, clamping of the same on Wall, Pole etc. including with required clamps & and all theinstallation materials required. [Detailed Specification in Technical Document] Inspection: RITES
Supply and provision of trunking of 65mm cover 50*80 including secton and accessories, compartment, exta portion, fish plate,body joint , cover Joint, High spacer angels,end caps etccomlete set.Make : Legrand or similar
Supply, installation and commissioning of 48V DC/200AH VRLA battery as per IRS S 93/96 (A) with amendment-1 or latest. Make Amaraja or similar firm's offer exide make.
Supply of CAT-6 Patch Cord-5 Mtrs. length [Detailed Specification in Technical Document] Inspection: Consignee
D-Link Blue CAT6 U/UTP Patch chord 2.0 mtrs. Detailed specification as per Product#1 of GeM Contract No.GEMC-511687778093889 dtd 30/01/2023).
Supply of STP CAT- 6 Cable compliant with latest EIA/TIA-568-C.2 Standard for CAT 6 Cable 305 Mtrs Roll /Bundle. [Detailed Specification in Technical Document].
Supply of RJ 45 connector suitable for STP/UTP Cable (D-Link) [Detailed Specification in Technical Document]
"Excavation of jointing pit without damaging the fiber and provision of joint chamber of 1.2 Mtr. diametre, 0.60 Mtr. height and 50 mm. thickness with two piece top cover and bottom cover 13 with holes for drainage and cable entry (The reinforcement drawing enclosed ). This includes backfilling and ramming of the trench after placing the joint closure and cable loop in the chamber without causing any damage to the same and consolidation of soil as well as disposal of soil as per plan and as advised by Railways representative. "
Supply of Single Mode Patch Cord length 10 meters (LC-SC/SC-SC/LC-LC/FC-LC) asper site requirement [Detailed Specification in Technical Document] Inspection: Consignee
Supply of Single Mode Patch Cord length 3 meters (LC-SC/SC-SC/LC-LC/FC-LC) asper site requirement [Detailed Specification in Technical Document] Inspection: Consignee
Supply , installation and commissioning of 48V, 25A SMPS charger with 03 no.s of 48v / 25Amps rectifier modules to charge VRLA battery as per RDSO spec. SPN-TL- 2399 version 4 or latest
Supply of Power supply, SMPS, 12V-For Equipment: Transreceiver HF/VHF/UHF, Mobile/Static, Output Current:15A, Charging:Float and Boost Make:Axiom or similar.
6 dB gain ground plane antenna for VHF mobile transceiver, 25W synthesized, configuration VM4, band136-174 Mhz full band, impedance 50 Ohms unbalanced with all accessories for mounting.
Supply of 12v 65Ah sealed power safe SMF battery.
Supply of low loss RF coaxial cable RG 217U with silver tipped connectors on both ends, 30 meters length (including BNC connectors either end of cable to match existing VHF set connectors).
Single fiber fusion splicer similar to fujikura 80C with standard accessories : ACADAPTER /BATTERY Charger ADC-18 1PC, AC Power Cord ACC-XX: 1PC spare electrode Elect2-20:1 pair carrying case CC-30:1PC USB cable USB-01: 1PC Sleeve loader SL01:1 PC dispenserAP01: 1 PC 21 screwdriver SC-01 1PC, Instruction Manual: 1 PC Quick reference Guide 1PC warning& cautions: 1 PC ; BATTERY RACK BRT-09, Battery charger cord DCC-18: 1 PC High precisionFiber cleaver CT-06: 1 PC, 3 in1 Stripper : 1PC & Protection sleeves: 25nos. ( A demo shall bearranged along with supply) as per TEC Specification g/osm/01-03 April2005 Model S177A.MakeFURUKAWA ELECTRIC CO Japan. Type approved or Similar. [Detailed Specification in Technical Document].Inspection: RITES
Supply of Optical Time Domain Reflectometer for 1310/1550nm fiber with resolutionof 22 60 Cms,dynamic Range of 314/29 dB with all accessories confirming to TEC Specification NoTEC Specification No G/OTD/02-03 March 2009.Make EXFO Model MAX 720C , AQ7270+735022.Make Yokogawa Electric Co Ltd Japan or Similar . Detailed Specification in TechnicalDocument. Inspection: RITES
Supply of Cable Route Locator set consists of seek Tech SR 20 receiver with 5 watt cable line transmitter seek tech ST-305with the following specification and suitable rechargeable cells, chargers 03 Nos. with suitable carrying case. 1. Target line and guide arrow quickly identify distortion. 23 2. Proximity signal and signal strength help work through difficult locats. 3. Trace any frequencies from 10HZ to 35KHZ. 4. Active live trace frequencies from 10HZ to 35KHZ. 5. Passive power trace 50HZ, 60HZ, <4KHZ brodline. 6. Passive power trace 4KHZ - 15KHZ - 36KKHZ. 7. Sound frequencies 16HZ, 5123HZ, 640HZ, 850HZ,8KHZ, 33KHZ. 8. Power source 4C Cell batteries included. 9. 30 user definable frequencies can be set from 10HZ to 35KHZ. MAKE/BRAND SR20 Complete Set or similar equivalent Inspection by RITES MAKE:RYCOM Instruments or better.
" Supply of cable fault locator similar to ANDIG model 5289M or better (contractor has to arrange field demonstration /field trail test at railway nominated site & OEM test certificate to be produced)."
"Supply of LAN tester UTP cable tester similar to make of Voltec/D-Link."
6 Amps MCB single pole of Legrand make or Similar.
Supply of 10 pair Switch board cable telephone cable 05mm dia,annealed copper conductor PVC insulated as per IPS TC-24/91
Installation, testing and commissioning of 25 Watt VHF set with GP antenna and antenna cable of length 30 M, power supply and battery of 12V 65AH. This includes supply and fixing 28 of GI pipe of suitable dia to the required hight as per the guidance of the field engineer, wiring of antenna cable through PVC conduit. All the materials required for installation to be supplied by the contractor.VHF equipment, SMPS power supply, Antenna&antenna cable will be supplied by the Railways.
H-Design, Preparation & Verification
CHECKING & VERIFICATION OF INTERFACE/LOGIC CIRCUITS:-Independent checking and verification of application logic circuits for stations having up to 25 Routes by IRSE/IRSTELO License holders.
CHECKING & VERIFICATION OF INTERFACE / LOGIC CIRCUITS:Indpendent checking and verification of Interface circuits for stations having up to 25 Routes by IRSE/IRSTELO License holders.
CHECKING & VERIFICATION OF INTERFACE / LOGIC CIRCUITS:-Additional payment for checking and verification of interface circuits/Logic circuits having more thant routes by IRSE/IRSTELO License holders.(unit : Numbers =Route)
DESIGN:-Design, preparation and submission of SIP for 4 line station.
DESIGN:- Design, preparation and submission of SIP for 5 line station.
DESIGN:-Preparation and supply of station working rules (SWR) as per South western Railway practice, based on SIP and Table of controls. The item includes two sets of documents for approval, after approval Contractor will supply completion SWR and spiral binding booklets 6 Nos.
DESIGN:-Generation of the Route Control Chart shall be done using the SIG-DATE tool 7 and submitted in AutoCAD file format.( The Route Control Chart shall be updated based on HQ observations, if any, until its finalization. The final approved copy shall be submitted on tracing film.) Unit: NUMBERS=PER ROUTE)
B1-Supply Non-SOR
Supply of Hylam sheet resin bonded 10mm thick of size 2400mmx1200mm.
Supply of Universal locks with one key for every 10 lock with SWR mark. INSPECTION - CONSIGNEE.
Supply of 200 Way Tag block.
Supply of Navtal Godrej make lock 50 mm with 2 keys.
Supply of Piezo electric Buzzers 24 V of different tone to be approved by Supervisor incharge of work.
Supply of toolkit for ESM as recommended by CSTE technical instructions consisting of 15 items including tool box.
Supply of crimping tool 25 Sqmm.
Supply of Signal aspects - LED Red with current regulator for the following types, with necessary inspection as per specification RDSO/SPN/199/2010 revision 1.0 or latest.
Supply of Signal aspects - LED Yellow with current regulator for the following types, with necessary inspection as per specification RDSO/SPN/199/2010 revision 1.0 or latest
Supply of Signal aspects - LED Green with current regulator for the following types, with necessary inspection as per specification RDSO/SPN/199/2010 revision 1.0 or latest.
Route-Colour light signal LED signal lighting unit for railway signalling as per RDSO spec RDSO/SPN/153/2011 Rev 4.1 or latest.
Calling on-Colour light signal LED signal lighting unit for railway signalling as per RDSO spec RDSO/SPN/153/2011 Rev 4.1 or latest.
Shunt-Colour light signal LED signal lighting unit for railway signalling as per RDSO spec RDSO/SPN/153/2011 Rev 4.1 or latest.
Relay, AC immune ,plug in type, style QNA1, Neutral line 24 V DC 8F/8B contacts, front 15 & back contacts metal to carbon, complete with plug board retaining clip & connectors confirming to BRS:931A, IRS:S-23/88 (Amdt 1), IRS:S@45"47@68 (upto Amdt 6) & IRS:S@45<47@78 (Amdt 1) or latest .The interlocking code for this unit shall be ABDGH.
"Universal plug in type Q style (ECX-61) AC LED lamp proving relay with in built current transformer type, slow release, neutral line relay, 4F/4B front and back metal to carbon contacts suitable for work in series with 110v ac, led signal lamp 15w conforming to RDSO spec., sts/e/relays/AC Lit LED signal/09/2002 amdt-1, BRS-941a, IRS.S.34 & IRS.S.23 interlocking code shall be ABDHK. "
Supply of Office table of Godrej T8 or reputed firm for keeping circuits/carrying office work
Supply of Office/ visitor/ study/ executive/ computer support Chairs (Cushioned) of Godrej or reputed firm for seating arrangement
Supply of RFID marker locator SML model or similar, 8000 or more marker records, Built in GPS module,1.5m Depth Range with LCD display Cable marker Locator.
Supply and installation of smart RFID marker, SML 1014 model or similar-Telephone based Electronic Cable marker 2.5 cm dia, minimum 1.5m depth range and with Hexadecimal ID code.
Supply of commercial/industrial grade operator VDU of sizes 55'' Full HD,HDMI/DVI connectivity, in built speaker etc (For this item pror approval of engineer in charge is required in written)
Supply of fan less industrial grade embedded PC (Similar to moxa v2406 or better) with all accesaries such as key board, mouse, Antivirus etc of industrial grade as per RDSO TAN No. STS/TAN/3007 Version 1.0 or latest )
FRP Road warning signal unit
"Supply of Wago terminal of 2-conductor disconnecting terminal block for 2.5 sq mm wire termination. Make: Wago/Elemex or similar with all accessories and taxes. "
FLEXIBLE COVER 180MM WIDTH
PLASTIC TRUNKING 195X50MM
FLEXIBLE COVER 85MM WIDTH
PLASTIC TRUNKING 105X50MM
Supply of data logger 512 digital inputs and 32 analog inputs for remote monitoring with network as per RDSO spec No.IRS.S99/2006 (Amd-2) or latest This includes supply of El modem, power supply arrangement for data logger consists of 12V,42AH VRLA batteries-4 Nos and 10A charger 1 No and fault diagnostic software along with computer-printer table and operator chair, Datalogger Data Analyser with laser jet printer of HP LASERJET M208dw / BROTHER HL-L2366 DW or 29 better (Specification of Data Analyser: All in one PC with intel core i7, 512GB SSD, preloaded with Windows 11 Home edition or better,21" display and 8GB/above RAM or better). In case of EI installation, this data logger is for logging events outside of El and full digital input must be supplied. Interface connection with EI is part of EI. The data logger will transfer its own data along with EI data to central monitoring unit by using El connectivity. Supply of Interconnecting cable between Contacts and Data logger - this can be either 60/40 indoor cable or jumper wires as per IRS:S-76/89 or latest RDSO specification as per requirement
C1-SCHEDULE (Execution Non SOR)
"Laying of PLB HDPE duct, 40/33 mm Dia, in the trenches and in the protective works already provided including in HDD portion and supply pulling of Nylone rope through it at diffeent places as per direction of engineer in charge or site engineer. "
Blowing of OFC cable 48F in already laid PLB HDPE duct.40/33 dia by using blowing machine providing the sufficient loops in loop/joint chambers and other associated work.
Leading in arrangement for OFC cable inside service building by providing large G.I. 3 Band at bottom & vertical G.I Pipe of 75 mm dia. The vertical pipe shall be taken 75 mm above the floor level & the mouth of the pipe shall be covered by Plastic Cap. The floor shall be restored to the original condition.
Fixing of 6 way PBT terminal blocks and termination of cable on each temrinal. Payment will be done per no.of cable terminations.(Unit: Number=Per Terminal of 6 Way block)
Installation ,wiring , testing and commissioning of data logger 512 digital & 32 anolog inputs. This includes installation, wiring, testing, commissioning and networking with existing NMDL 5 system at test room inclding necessary modification in the database, complete along with contractor own material. This also includes programming of data logger for fault diagnostic in suitable structured language in consultation with railway. Required potentional free contacts will be provided in the Relay rooms
Carefully opening the bunching inside the relay room as instructed, removing the relay 7 pin along with the wire, neatly and carefully removing the wire duly testing with buzzer, re-bunching & placing with modi nylon/twine threas and PVC dotted with buttons where required. (Unit: Numbers= Wire)
Digging of cable trench to a depth of not less than 30cm in rocky terrain, concreting the trench with 150mm thick concrete in the ratio 1:2:4 and after proper curing ,back filling with excavated soil.
Video recording of cable trench using minimum720P and above HD camera and submit one copy in New removable hard disks (With capacity as per requirement); Two copies in DVD-R
Transportation of light materials/men with tools, documents from central location to the workspot and back.
UG Cable route tracing service using Radiodetection make Advanced Cable & Pipe 11 Locator equipment at SWR, Bengaluru projects division (work to be carried out between Whitefield and Jolarpet stations of SWR SBC division). - Equipment model to be used for UG Cable route tracing service Radio detection make RD8100 PDLG or RD8200G. - Report in the form of KML file (soft copy) to be submitted to Customer within 30 days from the date of work completion at site
Provision of Lighting arrangement for NI working at both side Goomty and Point locations.
Cable armours soldering and earthing as instructed by incharge SSE/JE at site.( Unit: Numbers= cable)
"Installation, testing and comissioning of Universal Fail Safe Block Interface as per RDSO Spec No. IRS:S-104/2012 or latest stuitable to work OFC/E1/Qaud media for IB Signalling [All misc items required for comissioning shall be supplied by contractor]"
Installation, testing and commissioning of Automatic Media changeover and modems 16 working on redundant channels for data transmission on OFC/Quad. This included installation & configuration of Industrial grade modem, wraping of E1 connections etc.,(Pair Unit=Set Per Block Section).
D1-Supply and Installation (Non SOR Items)
Supply, Installation, testing and commissioing of SMPS based Integrated Power Supply 1 System (IPS system) Conrming to RDSO Specication No: RDSO/SPN/165/2023 (Ver 4.0 or latest) as per Drawing No: SDO/IPS/EI-6L/RE/004 and supply of spares as per enclosed. (Warranty Period : Upto 48 months from the date of delivery.)
Supply and Laying of PVC Warning Tape colour Orange, width of 250mm (10") by printing with black letters 'Indian Railway Signal/Telecom/OFC Cable' on both sides
Supply and installation of HRC Fuse base and carrier-32A with 2/4/6/10/16/20/32/50. A fuse as per the load codition. (HRC fuse base, carrier and fuses shall be procured from standard firms. Cu ligs 3/0.75mm wire and other required materials shall be supplied by contractor.
"Provision of Earth connection to Location Boxes and Signals with MS Flat as per Drg.No.RVNL/S&T/SC-07/2016:" (f)Painting of MS Flat with one coating of red oxide as primary and two coats of anti- corrosive black.
Fabrication and supply of GI termination box for point machine of size 45cm x 23cm x 12 cm, the termination box to be fabricated out of GI sheet 10SWG. The termination box to be provided with 2 nos of M.S. angle of size 50x50x6mm of length 1000mm each and GI pipe of 40 mm 6 dia and length of 450mm. The termination box is also provided with teak wood plank of size 25 mm thicknesses for fixing of terminals. Necessary bolts, nuts and screws are to be provided for fabrication of termination box.The termination box is to be painted double coat with approved quality of paint black enamel on to the outside and to be painted with white enamel in to inside of the box (All materials are to be procured by the contractor).
Supply and laying of 50Sqmm insulated copper cale in suitable PVC pipe. All other materials required for installation to be arranged by contractor. (This item is for coventional lightning arretser). Inspection: Consigneee.
Supply, installation, testing and commissioning of Heat and smoke multi sensor as per 16 RDSO/SPN/217/2025 ver-3.1 or latest. along with its base, backbox and all accessories in compliance with IS:2175 and IS:11360 standards and Underwriters Laboratory (UL) listed. (As per RDSO TAN 3009 Ver 1.0, Document No.STS/E/TAN/3009 dated 17.02.2025 or latest).(INSPECTION: RDSO)
Supply of Analogue LHS cable as per RDSO/SPN/217/2025 ver-3.1 or latest (INSPECTION: RDSO)
Supply, Installation, testing and commissioning of linear heat sensing interface module, (Monitor module) for LHS cable with backbox and all other accessories as per RDSO/SPN/217/2025 ver-3.1 or latest in compliance with IS standards and Underwriters Laboratory (UL) listed.(INSPECTION: RDSO)
Supply of Fire survival cable 2c x 1.5 sq.mm unarmored as per RDSO/SPN/217/2025 ver-3.1 or latest.(INSPECTION: RDSO)
Supply, installation, testing and commissioning of Networkable single loop addressable Fire alarm Control panel expandable upto 4 loops with GSM interface (without GSM module) as per RDSO/SPN/217/2025 ver-3.1 or latest. This work involves supply, fixing, installation and testing of 21 control panel. The control panel shall be networkable to Zonal /Divisional headquarters preferably over TCP/lP and shall have clock synchronization facility. This includes Networking module (TCP/IP) for control panel along with power supply unit and battery set of required capacity for 24 hours backup as per RDSO specification. The panel should support degrade mode operation in compliance with IS: 2189 , EN 54 standards and Underwriters Laboratory (UL) listed.(INSPECTION: RDSO)
Supply, installation, testing and commissioning of GSM module for Control panel with backbox and all other accessories as per RDSO/SPN/217/2025 ver-3.1 or latest. with auto dialer function to SMS during failure or fire situation.(INSPECTION:RDSO)
Supply, installation, testing and commissioning of Manual call point (resettable) with backbox and all other accessories as per RDSO/SPN/217/2025 ver-3.1 or latest.(INSPECTION:RDSO)
Supply, installation, testing and commissioning of Relay module with backbox and all other accessories as per RDSO/SPN/217/2025 ver-3.1 or latest.(INSPECTION:RDSO)
Supply, installation, testing and commissioning of Hooter and Visual strobe alarm units with backbox and all other accessories as per RDSO/SPN/217/2025 ver-3.1 or latest along with its power supply unit.(INSPECTION:RDSO)
Supply, installation, testing and commissioning of Control module with backbox and all other accessories as per RDSO/SPN/217/2025 ver-3.1 or latest.(INSPECTION:RDSO)
Supply, installation, testing and commissioning of EOL as per RDSO/SPN/217/2025 ver- 3.1 or latest as directed by the site engineers.(INSPECTION:RDSO)
Supply, installation, testing and commissioning of Monitor module for 3rd party with backbox and all other accessories as per RDSO/SPN/217/2025 ver-3.1 or latest.( INSPECTION:RDSO)
Laying / drawing of various type of cables on PVC pipe / capping casing, or cable trays, ladder, shelter etc as instructed by Railway engineer at site. (Indoor cables to be drawn through pipe, outdoor cables if required to be clamped on wall/floor etc.(INSPECTION:CONSIGNEE)
CO2 Fire Extinguisher: Supply, installation, testing and commissioning of CO2 fire extinguisher 6.5 kg capacity conforming to IS 15683 with ISI mark provided with all fittings and accessories. Make Safex/Bharat or similar.(INSPECTION:CONSIGNEE)