| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.5 LAccepted-Finance | L1 | Accepted-Finance Evaluated | |
| 2 | L2₹38.8 L+₹5.4 L (16.1%)Accepted-Finance | L2 | Accepted-Finance Evaluated | |
| 3 | L3₹39.5 L+₹6.1 L (18.1%)Accepted-Finance SHOP NO 2 JANKI PLAZA BHAGWAN MAHAVIR PATH KOPARGAON AHMEDNAGAR MAHARASHTRA 423 601 | KOPARGAON | AHMEDNAGAR | MAHARASHTRA | 423601 | L3 | Accepted-Finance Evaluated | |
| 4 | L4₹40.0 L+₹6.5 L (19.4%)Accepted-Finance | L4 | Accepted-Finance Evaluated | |
| 5 | L5₹40.6 L+₹7.1 L (21.3%)Accepted-Finance | L5 | Accepted-Finance Evaluated |
Tender Value
₹43.6 L
EMD Value
₹87,200
Closing Date
25 Sept 2021, 6:00 pmClosed
Garrison Engineer North Ahmdnagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
Special Repairs to Old KV Building of KV No 1 at GE (N) Ahmednagar
2021_MES_471791_1
8560 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Ahmednagar
Class D Cat a (i)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmednagar
₹87,200
Yes
27 Sept 2021
1 Sept 2021
27 Sept 2021
1 Sept 2021
25 Sept 2021
15 Sept 2021
Amount
Dismantling of stone slab & tiles of any description in floor, approx laid, bedded & pointed in any mortar in any situation etc complete all as specified and directed by Engineer-in-Charge
M&L for Mirror polished machine cut kota stone slab flooring 20-25mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete over and including screed bed 15mm thick in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge
M&L Dark shaded Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, as in skirting, area of each tiles not xceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including in cement and sand mortar (1:4) including dismantling etc complete all as specified and directed by Engineer-in-Charge
M&L for 60 mm thick, PCC pavers interlocking tiles of glossy finish, pointed with white cement and pigment ,any shape & size conforming to IS 15658 of 2006. M-35 grade made up with 12.5mm graded mechanically crushed stone aggregates, factory made over and incl 30mm thick sand cushioning and joints filled with fine sand including leveled with plate vibrator & sweeping etc complete all as specified and directed by Engineer-in-Charge
M&L for 80 mm thick, PCC pavers interlocking tiles of glossy finish, pointed with white cement and pigment ,any shape & size conforming to IS 15658 of 2006. M-35 grade made up with 12.5mm graded mechanically crushed stone aggregates, factory made over and incl 30mm thick sand cushioning and joints filled with fine sand incl leveled with plate vibrator & sweeping etc complete all as specified and directed by Engineer-in-Charge
Demolition of cement concrete (un-reinforced) in ground floor & paving n.exc. 15cm thick below or above ground level etc complete all as specified and directed by Engineer-in-Charge
M&L for providing 75mm thick plain cement concrete 1:4:8 type D2 (40mm graded stone aggregate) as in sub base etc complete all as specified and directed by Engineer-in-Charge
M & L for 75mm thick PCC (1:3:6) type C-2 using 40mm graded mechanically crushed stone aggregate as in plinth protection surface finished even and smooth without using extra cement with & including 10mm wide, 30mm deep joints at the rate of 3.00 mt centre to centre and at every turning & filling the joints with bitumen & sand mixture etc complete all as specified and directed by Engineer-in-Charge
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed by Engineer-in-Charge
Material and labour for rendering, 10 mm thick on stone / concrete surfaces in cement and sand mortar (1:6) surfaces finished even and smooth with using extra cement in chhajja etc complete all as specified and directed by Engineer-in-Charge
M&L for rendering, 15 mm thick on stone/brick / concrete surfaces in cement and sand mortar (1:4) surface finished even and fair without using extra cement with using water proofing compound @ 3% of cement used etc complete all as specified and directed by Engineer-in-Charge.
M&L for newly plastered surface of walls and applying two coats of cement based paint (any tint) on walls over a coat of primer, at any height etc complete all as specified and directed by Engineer-in-Charge
M & L for complete removal of existing treatment by pressure washing of wall/Ceiling/Roof surfaces of any description and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces etc complete all as specified and directed by Engineer-in-Charge
M&L for Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work over a coat of cement base putty to maske surface even and smooth etc complete all as specified and directed by Engineer-in-Charge
M & L 6mm thick asbestos cement, corrugated or semi corrugated sheets in roof walls fixed with 'L' type or 'J' type or cranked hook bolts, washer etc including dismantling etc complete all as specified and directed by Engineer-in-Charge
Fixing only 6mm thick asbestos cement, corrugated or semi corrugated sheets in roof walls fixed with 'L' type or 'J' type or cranked hook bolts, washer etc including dismantling etc complete all as specified and directed by Engineer-in-Charge
S&F 4 mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws etc complete all as specified and directed by Engineer-in-Charge
M&L for 16mm to 18mm thick pre-polished granite stone slab of approved shade and colour Jet Black / Telephone Black as in top table, top of WHB, kitchen slab/platform, steps, gate pillars, cills etc or on vertical surfaces including vertical projection, full round moulding the edge including 10 mm thick backing coat in cement and sand mortar (1:3) jointing & pointing in white cement (1:2 ) using marble dust with admixture of pigment to match the shade of granite rubbing etc complete all as specified and directed by Engineer-in-Charge
M & L Digitally printed glazed ceramic tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry over and including 10mm thick backing coat in cement and sand mortar (1:3) and pointed in white or colour cement to match the shade of tiles etc complete all as specified and directed by Engineer-in-Charge
M & L for pre-cast cement concrete solid blocks, exc. 10 cm in width type C-1 (1:3:6) using 20 mm graded aggregates and setting in cement and sand mortar (1:6) including demolition etc complete all as specified and directed by Engineer-in-Charge
M & L for preparing new plastered surfaces of walls and applying two coats of OBD over a layer of putty surface finished with roller finish on plastered surfaces of walls including preparation of surfaces etc complete all as specified and directed by Engineer-in-Charge
M & L for preparing old untreated/ treated surfaces of ceiling and applying two coats of distemper oil emulsion, including removing ceiling boards from frame work and refixing the same after distempering and touch up as and where required after fixing the ceiling boards to the framework.
Taking down carefully copper/aluminum point wiring (light/fan/bell/socket, power point etc) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors, etc complete all as specified and directed by Engineer-in-Charge
M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable drawn in and incl PVC Casing and capping ISI Marked with its accessories with provn of PVC boxes and fixed with brass screws cup washer for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable as earth continuity conductor to common earth & connecting to earth dolly for the following, etc complete all as specified and directed by Engineer-in-Charge. Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, bulkhead lights, bldg security light etc
One light point controlled by one piano type switch 5 Amp single pole, one way
One fan point controlled by one piano type switch 5 Amp single pole, one way
One 3 pin 5 Amp socket outlet on same board controlled by one piano type switch 5 Amp single pole one way
One 3 pin 5 Amps socket outlet on independent board controlled by one No piano type switch 5 Amps single pole one way
One bell point on independent board controlled by one piano type switch 5 Amp single pole, one way
All as per Item No 24 here-in-before but with 2.5 Sqmm Copper conductor cable for one 3 pin, 15 Amp socket outlet on independent board
S&F Modular Switch, 6 Amp, one way, one Module. etc complete all as specified and directed by Engineer-in-Charge
S&F Modular Switch, 16 Amp, one way, one Module. etc complete all as specified and directed by Engineer-in-Charge
S&F Modular Socket Outlet 6 Amp, 2/3 pin, combined two module etc complete all as specified and directed by Engineer-in-Charge.
S&F Modular Socket Outlet 6 Amp / 16 Amp - 2/3 pin combined two module etc complete all as specified and directed by Engineer-in-Charge
S&F bell Ding dong type elelctric 230V AC single pole etc complete all as specified and directed by Engineer-in-Charge
S&F Modular Bell push, 6 Amp, one module etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting etc complete all as specified & directed by Engineer-in-Charge
Supply & fixing Bulb 9 Watt (cool day light) having colour temp 6500 K and lumen output 950 suitable to fix on batten holder and wall light etc complete all as specified and directed by Engineer-in-Charge
M&L for ceiling rose 3 terminal / PVC/ polycarbonate, isolated body etc complete all as speccified and directed by Engineer-in-Charge
S&F in replacement double door Sheet metal enclosures factory madeVertical concealed in wall DBs 4 way, (TPN DB's) 415 volts including 63 Amp MCCBs incomer, protection class IP-42, suitable for fixing MCBs, etc, conforming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 200 Amp rated copper Busbar, With Neutral bar, Earthbar and Cable ties for Cable management, Fully shrouded, Neutral bars, Prefitted masking sheet etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement double door Sheet metal enclosures factory made DBs 8 way, (SPN DB's) 240 volts protection class IP-42, suitable for fixing MCBs, etc, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 200 Amps rated copper Busbar, With Neutral bar, Earthbar and Cable lies for Cable management, Fully shrouded, Neutral bars, Prefitted masking sheet etc complete all as specified and directed by Engineer-in-Charge
S&F in replacement double door Sheet metal enclosures factory made DBs 4 way, (SPN DB's) 240 volts protection class IP-42, suitable for fixing MCCBs, etc, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 200 Amps rated copper Busbar, With Neutral bar, Earthbar and Cable lies for Cable management, Fully shrouded, Neutral bars, Prefitted masking sheet etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing MCB , SP, AC, 240 volts of 06 to 40 Amp, 16 KA Capacity, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing MCB, TPN, AC, 415 volts of 63 Amps, 16 KA Capacity, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing MCB, SPN, AC, 240 volts of 40 Amps, 16 KA Capacity, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing MCB, SPN, AC, 240 volts of 63 Amps, 16 KA Capacity, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
S&F Slim line advance square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack LED Tube light fitiing 30 Watt with LED light source 6500 K with uniform light output, with all accessories including its connection with 2 core seathed copper conductor cable of size 0.5 Sqmm with complete with all accessories etc complete all as specified and directed by Engineer-in-Charge
S & F Lumeno LED Bulb 10 Watt (cool day light) having colour temp 6500 K and lumen output 950 suitable for "B-22 type to fix on batten holder and wall light etc complete all as specified and directed by Engineer-in-Charge
S&F in replacement energy saving and environmental friendly long life LED street light 25 Watt (Bldg security light) made up of pressure die cast aluminium housing with mild power LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP65 protection and impact resistance of IK07 fixed on wall with GI pipe of suitable dia with all fixing accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V , 50 HZ etc complete all as specified and directed by Engineer-in-Charge
S&F Suspended architectural LED lumininaire provides soft -light and glare free symmetrical illumination with continuous mounting end cap of capacity20 Watt Make -Havell's Cat Part: (CONSTA1144LP20WLED840SPCWH) or equivalent make mentioned in list of makes in Appendix `C'
S&F sub main wiring with two single core PVC insulated,unsheathed, FRLS stranded copper conductor cable 6 Sqmm with 4 Sqmm PVC insulated, unsheathed, FRLS stranded copper conductor cable as earth wire drawn through in and incl PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge Note : 1. Porper colour coding shall be added for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) Note: Two run of 6 sq.mm cable i.e for one run for phase, one run for neutal with one run of 4 sq.mm cable for earth and one run of PVC Casing & caping shall be measured as one unit
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. Earth pit not less than 2.25mtr depth and top edge of the earth plate not less than 1.5mtr below normal ground level connected to galvanised earth lead wire 4.0Sqmm dia by means of nuts,bolts & washer etc. Earth wire connected upto main earth point/DBs alongwith 15mm dia earth protection pipe from top edge of the earth plate to main earth point to be connected and 20mm dia watering pipe light grade with funnel and provn of PCC using cement concrete (1:2:4) mix type B1 ( using 20 mm graded stone agregate) and RCC pit cover 50 mm thick precost RCC (1:2:4) mix type B1 duly reinforced with 8 mm dia of ms bar @ 15 mm CIC with both way lifting arrangement complete including all necessary excavation & earth work etc complete all as specified and directed by Engineer-in-Charge
Supply and installing testing and commissioning factory made Polycarbonate (shock proof, rust free, corrosion free, acid and chemical resistant, fire retardant, having high impact, made of halogen and silica free recyclable material), UV resistant, having high grade gasket made of Polyurethane, should withstand glow wire test at 960C should be flame retardant,thickness of panel should be 3.15 mm and the feeder pillar panel should hold type Test certificate (CPRI) with switchgear assemblies as per IEC 60 439-1. following tests performed and passed and satisfactory : (a) Temperature Rise (2) Dielectric properties (3) short circuit withstand current- Rated peak & shor time withstand current and Rated conditional short circuit current (4) Effectiveness of Protective circuits. (5) Clearance & creep age distance (6) Mechanical operation, Complete with necessary foundation work as directed at site by Engineer-in-charge and making proper electric connection complete .(Busbar connected in incoming to outgoing MCCB and also provide outgoing Cable Chamber provided to suitable space for cable connection) etc complete all as specified and directed by Engineer-in-Charge
Installation- Outdoor/floor mounting System voltage-415V, 3 phase, 4 wire, 50 Hz Bus bar rating- 200 A/phase
Cable entry (Incoming & Outgoing) - from bottom
Incoming :- (a) MCCB 100 Amp25 KA rating 4 Pole 440 volts with megnatic setting and thermal release - 01 No
Outgoing (a) MCCB 63 Amp 25 KA rating 4 pole 440 volts with magnatic setting and thermal release-03 Nos
Supply and laying or fixing or passing in trenches/ on pole / through pipes, 1100 volts grade XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor of cross sectional area 35 sq mm 3.5 core including connection with cable glands & lugs etc and testing on completion etc complete all as specified and directed by Engineer-in-Charge
Supply and laying or fixing or passing in trenches/ on pole / through pipes, 1100 volts grade XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor of cross sectional area 70 sq mm 3.5 core including connection with cable glands & lugs etc and testing on completion complete all as specified and directed.
Excavation in trenches n. exc 1.5 m wide and n. exc 1.5 m in depth and getting out in hard/dense soil etc complete all as specified and directed by Engineer-in-Charge
Returnig, filling in including spreading, levelling, watering and well ramming in layers, n exc 25 cm thick in soil etc complete all as specified and directed by Engineer-in-Charge
Removing exacavated soil to a distance n. exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting point etc complete all as specified and directed by Engineer-in-Charge
Supply & Lay HDPE pipe 40 mm bore light weight with 0.95 gm/cm2 IS: 4984(1995) PN 2.5 for laying of LT cable complete with all accessores etc complete all as specified and directed by Engineer-in-Charge
Taking out/down and opening of existing ceiling fans 1200 mm sweep,from any position, of any make etc & refixing at the desired location after reassembling and after servicing/overhauling by thouroghly cleaning the shaft,rotor,stator and applying lubricant/grease to bearings and one coat of super enamelled varnish over winding to improve the insulation resistance including repair /replacement of spare parts/ material /items , making connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.50 Sqmm upto 0.50 Mtr length including using material/parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional complete all as specified and directed.
Material and labour for preperation of ceiling fans 1200 mm sweep, of any make by cleaning of metal surfaces including painting with spray painting on required gloss with white synthetic enamel paint on complete body of fans and writing No with black synthetic enamel paint etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep etc complete all as specified and directed by Engineer-in-Charge.
An amount of Rs 62,591.00 shall be deducted from BOQ on account of schedule of credit
S.k ENTERPRISES
sunway associates
Manak landmarks
M/s. A P INFRA
M/s AG PATHAN
M/S-B.R.SONAWANE
M/S MAHESHWARI ENTERPRISES
M/s Meher Construction
Arihant Construction
Ms. M.D. Auty
Priyadeep Construction
OM SAI ASSOCIATES
G. K. Engineering And Fabricators
M/s. N D Karande
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .