| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-AOC | L1 | Accepted-AOC being lowest tender reasonable | |
| 2 | L2₹21.3 L+₹1.2 L (5.78%)Rejected-Finance | L2 | Rejected-Finance being not lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
13 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE JORHAT
Military Engineer Services Garrison Engineer Jorhat Post Rowriah Dist Jorhat PIN 785 005 Assam
COMPREHENSIVE MAINTENANCE OF VARIOUS TYPES AIR CONDITIONINGS AND REFERIGERATIONS EQPT AND CONNECTED MAINT WORKS UNDER GE JORHAT.
2021_MES_483321_2
8036/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JORHAT-785005
Please refer tender details
6 documents required · 6 mandatory
₹500
Yes
GE JORHAT
₹40,000
Yes
12 Feb 2022
24 Nov 2021
14 Dec 2021
24 Nov 2021
13 Dec 2021
1 Dec 2021
24 Nov 2021 - 27 Nov 2021
60 days
Amount
NOTE :The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
M&L for removing , refixing , re-installation and re-commissioning including providing suitable mode of transportation for carrying window type AC upto 2 TR from site to civil workshop for repair / replacement to corroded body by replacing with Pre Engineering coloured sheet for side / top and 3 mm MS plate in bottom of AC including replacement of unserviceable spares and return to MES store yard etc complete all as per OEM and as directed.
M&L for removing , refixing , re-installation and re-commissioning including providing suitable mode of transportation for carrying split type AC upto 2 TR from site to civil workshop for repair / replacement to corroded body by replacing with Pre Engineering coloured sheet for side / top and 3 mm MS plate in bottom of AC including replacement of unserviceable spares and return to MES store yard etc complete all as per OEM and as directed.
Comprehensive maintenance of AC of various capacity and make of split type / window type and rectification of defects including necessary dismantling, pumping down if required and taking out for repairing and refixing at site, replacing minor spare parts as required such as wire terminals, soldering / crimping required at site for proper functioning of the equipment etc complete all as per OEM and as directed.. Note : Unserviceable major spares parts shall be measured and paid seperately under Supply only items here in after.
Supply only starting capacitor 100 to 150 MFD suitable for window/Split type AC complete all as per OEM and as directed..
Supply only running capacitor 36 MFD suitable for window/ Split type AC complete all as per OEM and as directed..
Supply only running capacitor 45+2.5 MFD/50+6 MFD suitable for split/ window type AC complete all as per OEM and as directed..
Supply only running capacitor 3/4 MFD for fan motor of window type AC complete all as per OEM and as directed..
Supply only fan motor 1/5 HP long shaft suitable for window type AC of any capacity, as per sample complete all as per OEM and as directed..
Supply only fan motor 1/5 HP suitable for out door unit of split type AC 1.5 / 2.0 Ton capacity etc. as per sample complete all as per OEM and as directed..
Supply only fan blade suitable for out door unit of split type type AC 1.5/2.0 Ton capacity complete all as per OEM and as directed..
Supply only thermostat switch suitable for window type ACs as per existing specification complete all as per OEM and as directed..
Supply only starting relay pin type for window / split type ACs as per existing specification complete all as per OEM and as directed..
Supply only prime control remote board (PCB) and tempreture digital display sensor suitable for split type AC 1.5/2.0 Ton capacity etc complete all as per OEM and as directed.
Supply only remote for A/C split type 1.5/2.0 Ton capacity of existing specification and make complete all as per OEM and as directed.
S&F Nitrile rubber insulation of size 7''/ 8" for suction and liquid refrigerant line for split type AC etc complete all as per OEM and as directed. Make-A-flex,Totaline or equivalent and approved.
Supply and fix copper tube 1/4" suitable for window ACs of any capacity complete all as per OEM and as directed.Make - Totaline or equivalent
Supply and fix copper tube 3/8" suitable for ACs complete all as per OEM and as directed. Make - Totaline or quivalent and approved
Supply and fix copper tube 5/8" suitable for ACs ( window / split ) etc complete all as per OEM and as directed. Make - Totaline or quivalent and approved
Supply and fix copper tube 1/2" complete all as specified and directed. (Make - Totaline/Carrier)
Supply and fix Condensing coil with copper tube and aluminium fins suitable for capacity 2.00 TR Split AC etc complete all as per OEM and as directed.
Supply and fix condensing coil with copper tube and aluminium fins suitable for capacity 1.5 TR Split AC . etc complete all as per OEM and as directed.
Supply and fix Cooling coil with copper tube suitable for indoor unit of split AC of capacity 1.5 /2.00 TR . etc complete all as per OEM and as directed.
Supply and fix fiber body complete suitable for indoor unit of split AC 1.5/2.0 TR etc complete all as per OEM and as directed.
Supply and fix factory made stand suitable for outer unit of split AC as per existing specification and make complete as per OEM and as directed.
Comprehensive maintenance of Split AC by taking out / down unit from wall / stand of any capacity , pumping down gas ,cleaning / washing of chocked condensing fins and tubes with water and solvent materials by using mechinical pressure after cleaning ,servicing , refixing of unit, leak testing including filling of nitrogen gas for pressure testing, vaccumissing the gas and bracing of leaked copper pipes, connecting the cables and testing for smooth functioning of unit complete as per OEM and as directed. Note:- Each unit shall be serviced only single time throughout the Contract period and the payment shall be done accordingly.
Comprehensive maintenance of Window AC by taking out / down unit from wall / stand of any capacity , pumping down gas ,cleaning / washing of chocked condensing fins and tubes with water and solvent materials by using mechinical pressure after cleaning ,servicing , refixing of unit, leak testing including filling of nitrogen gas for pressure testing, vaccumissing the gas and bracing of leaked copper pipes, connecting the cables and testing for smooth functioning of unit complete as per OEM and as directed. Note:- Each unit shall be serviced only single time throughout the Contract period and the payment shall be done accordingly.
S&F in repair thermatically sealed compressor unit of window / split type ACs of 1.5 TR capacity including initial charging of gas and oil all complete all as per OEM and as directed.
S&F in repair thermatically sealed compressor unit of window / split type ACs of 2.0 TR capacity including initial charging of gas and oil all complete all as per OEM and as directed.
Taking down and removing the existing window /split type AC unit of any size complete including all accessories and closing the existing opening of wall with brick work in cement mortar 1:4 and rendering with cement mortar (1:4),whitewash /distempering to match with surrounding and handing over the unit at MES store complete all as directed.
Fixing only Window AC / Split type AC including all accessories, making suitable size opening in existing wall suitable for fixing of air conditioner (AC) including making good the disturbed surfaces with cement plaster ( 1:4 ) and necessary distemper to match with existing etc complete all as per OEM ,specified and as directed.
Supply and filling of Refrigerant gas R- 22 C in different cooling unit etc complete all as per OEM and as directed. NOTE ;- ( Referigerent gas shall only be supplied in sealed cylinders and the empty gas cylinders shall be returned to contractor after use.)
Supply and filling of Refrigerant gas R- 134A in different cooling unit etc complete all as per OEM and as directed. NOTE ;- ( Referigerent gas shall only be supplied in sealed cylinders and the empty gas cylinders shall be returned to contractor after use.)
Repairs to voltage stabilizer of capacity 5/3 KVA of any make/model including rewinding of main transformer with copper wire , replacement of sensing transformer, connector, 30 Amps power relay and 3 core multistranded PVC insulated flexible etc complete all as per OEM and as directed.
Repairs to voltage stabilizer of capacity 2/1 KVA of any make/model including rewinding of main transformer with copper wire , replacement of sensing transformer, connector, 30 Amps power relay and 3 core multistranded PVC insulated flexible etc complete all as per OEM and as directed.
Comprehensive maintenance Water Coolers and Refrigerator of various capacity and make and rectification of defects including necessary dismantling and taking out repairing and refixing at site, replacing minor spares such as small pieces of wire terminals, necessary soldering / crimping required on site for proper functioning of the equipment etc complete all as per existing OEM and as directed. NOTE : Unserviceable spares shall be measured and paid seperately under relevant items here in after.
M&L for transportation of Refrigerators of capacity 180/286 ltr , from site to local workshop for tinkering of unserviceable body with 22 SWG MS sheet by soldering /welding ,spray painting of complete refrigerator with two coat of synthetic enamel paint of existing colours over one coat of primer/red oxide,supply and fix broken legs ,tray, hinges, door beeding & handle, and transportation of refrigerators back to AGE E&M yard and necessary testing & commissioning etc complete all as per existing OEM and as directed.
M&L for transportation of water cooler of capacity 40 / 60 / 80 / 120 ltr , from site to local workshop for tinkering with 22 SWG MS sheet by solding / weldering ,spray painting of complete with two coats of synthetic enamel paint of existing colours over and including one coat of red oxide primer,supply and fixing broken legs ,tray, hinges, door beeding & handle as per existing and transportation back of repaired water cooler back to AGE E&M yard and necessary testing & commissioning etc complete all as per existing OEM and as directed.
Supply only Fan motor 1/3 HP with blade etc complete all as per OEM and as directed.
Supply only relay of 1/3 HP compressor etc complete all as per existing OEM and as directed.
Supply only Over load Proctector relay for 1/3 HP compressor complete all as per existing OEM and as directed.
Supply only Thermostatic switch for water cooler of any capacity complete all as per existing OEM and as directed.
Supply only Starting Capacitor 40-60 MFD complete all as per existing OEM and as directed.
Supply only Running Capacitor 10 MFD complete all as per existing OEM and as directed.
Supply only Push button Tap for water cooler as per sample. complete all as per existing OEM and as directed.
Supply only Float valve 1/2" PVC complete all as per existing OEM and as directed.
Supply only PVC connection 1/2", 1 mtr length complete all as per existing OEM and as directed.
Supply only Plug top 15 / 16 Amps 3 pin , 240V etc complete all as per existing OEM and as directed.
Supply only Plug top 5 / 6 Amps 3 pin , 240V etc complete all as per existing OEM and as directed.
Supply only Cooling coil unit of Aluminium for freezer unit for 230/300 Litres complete all as per existing OEM and as directed.
Supply only Cooling coil unit of Aluminium for freezer unit for upto 220 Litres complete all as per existing OEM and as directed.
Supply only Relay suitable for refrigerator 1/8 HP compressor complete all as per existing OEM and as directed.
Supply only copper Capillary tube for refrigerator any capacity complete all as per existing OEM and as directed.
Supply only Door lining (magnetic) for refrigerator 230/310 Litres capacity complete all as per existing OEM and as directed.
Supply only Door lining (magnetic) for refrigerator upto 220 Litres capacity complete all as per existing OEM and as directed.
Supply only PVC stand for Refrigerator of any make and capacity etc complete all as directed.
Supply only Relay switch suitable for refrigerator 1/6 Hp compressor capacity complete all as per existing OEM and as directed.
Supply only Over load protector relay suitable for refrigerator complete all as per existing OEM and as directed.
Supply only Cabinet lamp for refrigerator as per sample complete all as per existing OEM and as directed.
Supply only Thermostatic switch for Refrigerator complete all as per existing OEM and as directed.
Note for item nos 3 to 59 ( Except supply only items ) :- (i) Unit rates shall be deemed to be inclusive of taking down unserviceable parts/accessories and refixing the same after minor repairs as required, adjustments of settings, cleaning down etc and replacement with new spare parts as and when required and including plant operations such as back washing, rinsing of filter and regeneration of resin, rinsing and blending for smooth and efficient functioning of the plant. (ii) Repair of plant shall be carried out by authorized competent persons of OEMs or their accredited/ authorised agencies and contractor shall be submitted supporting document of authorized representative of existing OEM of equipment to Engg-in-charge . The service charge of OEM shall deem to be included in above quoted rate. (iii) Blank (iv) Labour component required for the repalcement of unserviceable parts shall be deemed to be included in the unit rate quoted against this item . (v)The Contractor shall maintain service reports for all visits & breakdown visits & copy of the same will be submitted every month to the Engineer in Charge. (vi)Above major parts only shall be measured and paid separately and other parts if required for funcationing of plants shall be provided by the contractor and the cost thereof shall be deemed to be included in the unit rate quoted against above items . (viii) The cost of transportation and other necessary equipment shall be arranged/brought by the contractor in this effect , hence the bidder/tenderer is advised to visit the site and assess the quantum of the work to be carried out in the contract and quoted there rate accordingly
S&F new sealed compressor unit of water coolers of 40 / 80 / 60 / 120 ltr capacity including intial charging of gas and oil including taking down old unserviceable one complete all as per existing OEM and as directed.
Supply and fix new sealed compressor 1/6 HP suitable for refrigerators.including taking down old unservicable one complete all as per existing OEM and as directed.
Supply and fix new sealed compressor 1/8HP suitable for refrigerators including taking down unserviceable one etc complete all as per OEM and as directed.
M&L for sub main wiring complete with two runs of 6 sqmm single core PVC insulated unsheathed cable 1100 volts grade with multistranded FRLSH copper conductor drawn in medium grade PVC conduit 20mm dia / PVC casing caping on walls/roofs incl one run of 4.0 Sqmm (Nominal area) PVC insulated unsheathed multi stranded (Green colour) copper conductor cable for earth continuity conductor connected to common earth dolly.including making good to the disturbed surfaces including taking down old unserviceable one complete all as specified and directed. (Note : Casing caping and its accessories including 2 runs of 6 sqmm cable & 1 run of 6 sqmm earth continuity conductor cable unsheathed shall be measured and paid as single unit).
M&L for removing , re-installation and re-commissioning including providing suitable mode of transportation for carrying Deep freezer capacity 300 ltr to 420 ltr form AGE E/M workshop to local workshop for repair to body by tinkering with 22 SWG MS sheet ,spray painting of complete deep freezer with two coat of synthetic enamel paint of existing colours over and including a coat of red oxide,replacement of broken legs , hinges, complete top beeding ,inside puff insulation and transportation back to AGE E/M yard and testing etc complete all as per existing OEM and as directed. Note:- Spares parts replaced under the said item shall be measured and paid seperately under relevant items here in after.
Supply only Relay for 1/3 Hp compressor(1208) etc complete all as per existing OEM and as directed.
Supply only Over load proctector relay for 1/3 HP compressor etc complete all as per existing OEM and as directed.
S&F in repair new sealed compressor of deep freezer of capacity 1/3 HP unit etc complete all as per OEM and as directed.
Material and labour for spray painting of refrigerator / water cooler externally with two coats of Duco paint of approved shade after necessary preparation of surfaces including denting, and re installing or refixing at same place.etc complete all as per OEM and as directed (a) Refrigerator of capacity 300 / 310 Lit
All as per item No 69.00 here in before but Refrigerator of capacity 200/220/230 Lit
All as per item No 69.00 here-in-before but Refrigerator of capacity 165/175 Lit
All as per item No 69.00 here-in-before but Water Cooler of capacity 155/150,150/100 Lit
All as per item No 69.00 here-in-before but Water Cooler of capacity 40/80 Lit
M&L for Point wiring with 4 Sqmm (Nominal area) PVC insulated, unsheathed, stranded FRLSH copper conductor cable (1100 Volts grade) drawn in and including PVC casing and caping with all fittings and accessories for one 5 Amps socket point controlled by one switch along with PVC insulated cable with stranded FRLSH copper conductor (green in colour) of size 2.5 Sqmm and connected to earth dolly including fixing of 1.2mm thick MS sunk terminal box of appropriate size suitably flushed to wall with 3mm thick plastic laminated/ebonite sheet cover fixed with brass screws and cup washers incl. making good the disturbed surfaces and taking down old unserviceable one complete all as specified and directed.
Supply and filling refrigerant gas R- 410 for package type AC ,complete all as sper OEM and as directed. NOTE ;- ( Supply of Referegent gas shall be done in sealed cylinder and empty cylinders shall be returned to contractor after use.)
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs __________ mentioned on Page No _______ shall be deducted from the total quoted amount of BOQ.
FREEZCON
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .