| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹99.2 LAccepted-AOC 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | ₹99.2 L Quoted ₹1.0 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹1.0 Cr+₹2.1 L (2.02%)Rejected-Finance | ₹1.0 Cr+₹2.1 L (2.02%) | L2 | Rejected-Finance Being other than lowest |
| 3 | L3₹1.1 Cr+₹10.4 L (10.1%)Rejected-Finance 1 2 GR FLOOR VITHALKUNJ NO 3 V P ROAD ANDHERI WEST MUMBAI 400 058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | ₹1.1 Cr+₹10.4 L (10.1%) | L3 | Rejected-Finance Being other than lowest |
| 4 | L4₹1.3 Cr+₹23.1 L (22.5%)Rejected-Finance NOT AVAILABLE | ₹1.3 Cr+₹23.1 L (22.5%) | L4 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹2.1 L
Closing Date
19 Jul 2023, 6:00 pmClosed
GE (NW) Navy Nagar, Colaba, Mumbai
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR MAINT OF CEILING FAN EXHAUST FAN WITH CONNECTED ACCESSORIES INCLUDING INTERNAL WIRING FITTINGS AND FIXTURE OF LOW RISE BUILDING AND REPAIR MAINT OF SUBMAIN WIRING METER CABIN AT VARIOUS BUILDINGS AND LIFT MACHINE ROOM OF LOW RISE BUILDING OF O
2023_MES_601869_1
8281/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (NW) Navy Nagar, Colaba
Class B and category b(i)
8 documents required · 8 mandatory
₹1,000
GE NW NAVY NAGAR COLABA MUMBAI
₹2.1 L
Yes
21 Aug 2023
7 Jun 2023
20 Jul 2023
7 Jun 2023
19 Jul 2023
28 Jun 2023
7 Jun 2023 - 12 Jul 2023
Amount
Taking down ceiling fans of 1200/1400mm sweep from site for repair complete all as specified and directed by Engr-in-Charge.
Rewinding of ceiling fan any size 1200mm size as per IS-13730 using super enameled copper wire of same guage complete and directed.
Overhauling of ceiling fan any size and Make, dismantling parts, properly cleaning/removing old existing grease oil and applying new oil grease, varnishing of winding, cleaning dust rust and assembling and connecting complete with copper conductor multi stranded 3 core wire of size 14/0.0076, and testing after refixing at site complete all as specified and as directed by Engr-in-Charge. Note: Canopy, bushes, bearing cap and down rod measured and paid separately.
Supply and fix Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet in provision for fixing complete all as required and as specified.
Supply only ceiling fan canopy suitable for 15mm dia rod with fixing Nuts and Bolts as approved by Engr-in-Charge.
Supply only gun metal bush suitable for any sweep fan of any make
Supply only capacitor 2.5Mfd. Make : USHA /ASIAN/EPCOS
Supply only ball bearing suitable for 230/300/380/450mm sweep Exhaust Fan. Make : TATA/NBC/SKF
Supply and Fix and replacement of 15mm dia clamp assembly with Nut, Bolts & rubber bush suitable for down rods and split pins as approved by Engr-in-Charge.
Supply and fixing ceiling fan down rod of length 300mm, inner diameter 15mm and thickness not less than 1.5mm with clamps Nuts, Bolts and washers for existing ceiling fan as approved by Engr-in-Charge
Supply only ceiling fan blade (set of 3) suitable to any sweep and makes complete all as specified and as directed. Make : USHA/Kaitan/CG
M & L for fabrication of fan hook made out of 12mm dia MS rod suitable for fan hook bend to shape 'S' including 12mm dia SS fastner as required at site and as directed by Engr in Charge.
M & L for preparing ceiling fan surfaces for painting by removing/cleaning dust and deposited material and applying one coat of white enamelled paint by spray to fan blades, body and down rod, canopy of ceiling fans complete all as specified and as directed.
Taking out unserviceable ceiling fan and deposit to MES Store, supply and replacement with ceiling fan 230V, 50 Hz, AC, 1200mm sweep, min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete with hanging arrangement by down rod alongwith steel wire rope for additional safety in ceiling fan with all allied accessories and connecting up with three core, 0.75 sqmm PVC insulated copper conductor cable complete all as specified.
Taking down Exhaust fan of any sweep for repairs complete all as specified and directed by Engr-in-Charge.
Overhauling of Exhaust fan any size and Make, dismantling parts, properly cleaning/removing old existing grease, oil and applying new oil grease, varnishing for winding, cleaning dust, rust and replacing petty items with new as required such as Nuts, Bolts, washers, bushes, ball bearing, cap, fan shaft, rotor, capacitor 2.5/4 Mfd, body cover etc and reassembling, connecting with copper conductor multi stranded 3 core wire of size 14/0.0076 complete and testing after refixing at site. Note: Rate of petty items to be replace shall be included in quoted rate.
Taking down deteriorted louvers and supplying and fix new louvers fixed type made out of 16SWG GI sheet with machine pressed cut for horizontal ventilation, bending into shape of size 45cmx45cm (outer) with 20x3mm flat iron base of size 45cmx45cm complete all as specified and directed by Engr-in-Charge
M & L for rewinding of exhaust fan with super enamelled copper wire of same size/gauge, no of turns as per existing, varnishing, oiling and greasing of any make of size 230/300/380mm sweep by dismantling its parts and replacing petty items with new as required such as Nuts, Bolts, washers, bushes, ball bearing, cap, fan shaft, rotor, capacitor 2.5/4 Mfd, body cover and cleaning of exhaust fan body and its blade by cleaning agent, assembling, and connecting complete with copper conductor multi stranded 3 core wire of size 14/0.0076, and testing after refixing at site. Note: Rate of petty items to be replace shall be included in quoted rate
S & F Exhaust fan blade suitable to any sweep exhaust fan and makes complete all as specified and as directed by Engr-in-charge. Make : USHA/Kaitahn/CG
M&L for preparing exhaust fan of any size surfaces for painting by removing/cleaning dust and deposited material and applying one coats of grey enamelled paint by spray to Exhaust fan body, blades and louvers complete all as specified and as directed by Engr-in-Charge
Cutting hole in existing concrete or brick wall suitable for fixing 300mm sweep exhaust fan making good the hole including proper internal plaster work and surface finish in side and outside the hole as per site requirement complete all as specified and directed by Engr-in-Charge
Taking out unserviceable and S&F Exhaust fan, 4 blade, heavy duty, double ball bearing, 230V, 50Hz,300mm sweep having power input 70W speed 1440RPM, with protective bird guard including connection as required at site with flexible copper cable all as per specified and directed.
Inspection / checking of serviceability for ceiling fan to avoid any accident on site a job shall be done as taking down ceiling fan from its position, checking and replacement of minor unserviceable and minor defective spare parts responsible for any accident (i.e 'S' hook, split pin, cotter pins, rubber bush etc) servicing the fan completely after removing of old grease from bearing and hanging it to its same loaction after complete assurence of any defects as specified inspecting fan for proper working, connecting complete with copper conductor multi stranded 3 core wire of size 14/0.0076 all as specified and as directed by Engr-in-charge. Note (a) Complaint pertains to unserviceable Ceiling fan/Exhaust Fan/Energy Meter as given by the Engr-in-Charge shall be attended within 48hrs from the day of complaint assigned to the representative of the firm as directed by Engr-in-Charge upto the satisfactory level and on failing which the penality shall be imposed @ Rs 250/- per day per item of Schedule (BOQ) (b) The Contractor or the accredited representative of the firm shall report to the JE concerned at the E/M Complaint Cell i.e Sub Station No -07 and RS-1 Colaba resp for receiving the complaints at 0900 to 1000hrs daily excluding Sunday and Holiday.
Taking down carefully copper/ aluminium point wiring i.e. light, fan, socket or power/points complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of ceiling, walls, floors, etc.
M & L for point wiring with PVC insulated unsheathed single core multi stranded copper conductor 1.5 sqmm, 1100 volts grade cable, FRLS, passing through PVC casing caping including accessories and provision of PVC box for mounting of modular Switchs & Sockets as required at site as directed by Engineer-in-Charge including one run of PVC insulated unsheathed multistranded copper conductor cable 1.5 sqmm (green colour) FRLS earth wire and connected to earth dolly for the following:- NOTE : Circuit conductor from MCB DB to Switch boards should not be less than 2.5sqmm.
One light/Exhaust/Ceiling fan point controlled by one switch.
One 3 pin switch socket combination 5 Amps on the same board with other switches.
One 3 pin switch socket combination 5 Amps, independent.
One bell point controlled by one push button
All as per item No 25.00 above but with 2.5 sqmm cable for one three pin 15 Amps socket out let controlled by one switch.
S & F in replacement with modular switch, 1 module, single pole one way 6 Amp conforming to IS:3854 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy).
S & F in replacement with modular switch, 1 module, single pole one way 16 Amp conforming to IS:3854 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy).
S & F in replacement with ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body of size 60x50mm
S & F in replacement with modular socket 6A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy).
S & F in replacement with modular socket 6/16A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy).
S & F in replacement with modular bell push switch, 1 module, single pole one way 6Amp ISI marked. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy).
S & F in replacement with modular electric bell ding dong, AC, 230V single pole.
S & F in replacement with modular stepped type fan regulator, 2 module, single pole one way ISI marked. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy).
Supply & Fixing Retrofit LED lamp 7 Watts complete all as specified and directed.
Supply & Fixing Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Taking out old wooden/PVC board and disconnecting all electric connection from switches, board and S & F modular PVC Gang box, screwless of 8 module for mounting of modular switches and sockets including blank plate for blank module. Make -Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy).
All as per Item No- 37.00 above but of modular PVC Gang box, 6 module.
All as per Item No- 37.00 above but of modular PVC Gang box, 3 module.
All as per Item No- 37.00 above but of modular PVC Gang box, 2 module.
All as per Item No- 37.00 above but of modular PVC Gang box, 1 module.
S&F modular white cover plate with frame, 8 module.
S&F modular white cover plate with frame, 6 module.
S&F modular white cover plate with frame, 3 module.
S&F modular white cover plate with frame, 2 module.
S&F modular white cover plate with frame, 1 module.
Taking down unserviceable FTL/batten fittings with supply and fix LED Aluminium housing of batten fitting 20 Watt, 240V, 4ft CDL/NW comprises of aluminium extruded channel in thermally conductive material with decorative end cap and high translucent serration milky white diffuser of high optically efficient plastic FR grade. The luminaire is pre-wired with high efficiency electronic driver having operating voltage 140-270V, P.F >0.95, THD <20% and IP20 protected alongwith provision of two Nos of PVC box of size 75x75x20mm for mounting light fittings including ceiling rose. The contractor shall provide test certificate from authorized lab. Make of Light Fitting : Wipro, Bajaj, Cropmton/Philips
Taking down unserviceable FTL/batten fittings with supply and fix LED integrated polycarbonate housing of batten of 10 Watt 2ft LED give minimum output lumen 1150 lm, efficiency >110, CCT 4000/6500K, CRI >80, power factor >0.9, operating temperature 45 degree celcious, THD <20% of housing polycarbonate extrusion with LED dimension 603mmx22mmx36mm upto 50% energy saving. Make of Light Fitting : Wipro, Bajaj, Crompton/Philips
Taking out any type of FTL fitting and S&F 10W LED batten with inbuilt smart motion sensor, 230 Volt , 50 Hz , 2 feet, polycarbonate extruted channel, powder coated with diffuser for glare free light, Inbuilt motion sensor prewired with 25% dimmer illuminous in ideal time with all accessories including two Nos of PVC box of size 75x75x20mm for mounting light fittings including ceiling rose complete with following specification. (i) housing-polycarbonate extrusion,diffuser- opal- polymer, LED type- MID power ,Light distribition- general Spread, LED efficiency - > 130 lumen/Watt, System effieciency- > 100 lumen/Watt, Driver efficiency - more than 85%, power factor- more than 0.95, THD - <10%, Mounting/Fixing- Wall/Ceiling, Ingress Protection - IP-20, Sensor type- HF inbuilt integral occupancy/movement sensor, sensor range- upto 5 mtrs(cone formation ), Dimming operation- default operation at 25% of the is rated value. On detection of motion, light output rises to 100% for upto 20 sec . in absence of otion switches back to default operation, LED life- upto 30,000 Hrs.Surge Protection- not less than 2KV. Note:- (i) contractor shall submit LM79 report LM 80Test certificates before claiming for payment .(ii) Warranty certificate for minimum 2 years to be submitted from OEM. Make: Bajaj/Polycab/Jaquar/Halonix.
S&F MCB DB SPN confirming to IP 43 - IK 09 with acrylic door, 8 way complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces by plastering or PCC work inclding distembering to the affetced to walls. Make:- ABB/Legrand/Siemens.
Taking out Old U/S and S&F MCB SPN, 32 Amp, 10 KA, 230 Volt.Make:- ABB/Legrand/Siemens.
Taking out Old U/S and S&F MCB,single pole, upto 20 Amp, 10 KA, 230 Volt.Make:- ABB/Legrand/Siemens.
S&F in relplacement with new cable PVC insulated three core over all PVC sheathed 2.5 Sqmm stranded copper conductor cable for connecion from DB to connector junction box for power supply to security light fittings drawn in PVC conduit not less than 20mm including taking out old one all as directed. Make of wire - Polycab/Plaza/Finolex/ Havells/L&T.
S & F junction box of size not less than 4x4 inch with connector encloser, 3 terminal/ PVC/ polycarbonate, isolated body including taking out old one.
S&F street light bracket bend to shape made as required of 40mm dia 1.0 mtr long GI pipe light grade fixed to pole/ Wall including M&L for fixing with the help of flat iron clamp of size 40x6mm two numbers with the help of nuts and bolts for fixing of street light fitting on the wall complete after taking out old U/S one all as specified and as directed.
Taking out old unsv security light fitting and S&F new bldg security light 60 watt with inbuilt smart motion sensor with with 25% dimmer illuminous in ideal time with all accessories comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) Min 60 watt roadway luminaire type with ingress protection IP 65/66 and SPD of capacity 10 KV etc complete with following specification. (i) housing- epoxy powder coated housing, enclosed with glass cover , LED type- High Power LED ,Light distribution- Bat wing, LED efficiency - > 130 lumen/Watt, System effieciency- > 100 lumen/Watt, Driver efficiency - more than 85%, power factor- more than 0.95 to 0.98, THD - <10%, Mounting/Fixing- GI Bracket, Ingress Protection - IP-65/66, Sensor type- HF inbuilt integral occupancy/movement sensor, Sensor type – Dusk Dawn sensor mounted on LED PCB, sensor range- upto 5 mtrs(cone formation ), Dimming operation- default operation at 25% of the is rated value. On detection of motion, light output rises to 100% for upto 20 sec . in absence of motion switches back to default operation, LED life- upto 50,000 Hrs. Surge Protection - 4 to 10 KV. Note:- (i) contractor shall submit LM79 report LM 80Test certificates before claiming for payment .(ii) Warranty certificate for minimum 2 years to be submitted from OEM. Make: Bajaj/Polycab/Shakti/Jaquar/Crompton.
S&F Wall fan, made of sturdy Engineering plastic, voltage 230V, 50 Hz, RPM 1350 Copper winding of sweep 400 mm including connection as required at site.
Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amp, 240 volts complete all as specified and directed.
Supply and fixing GI safety wire rope (SWR) with locking arrangement for ceiling fan including all accessories complete all as specified and as directed.
Supply, install, testing and commissioning of meter cabin panel mounted on angle iron frame 40x40x5 mm grouted on floor,cubical indoor type for 415V, 3 phase, 4 wire made out of 2 mm thick CRCA sheet weather, vermin proof factory fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 200 Amps rated copper bus bar(All in equal size), top and bottom cable entry with proper size glands including disconnecting cable connections and electronic meters from old meter cabin panel and fixing & connecting in new installed panel with provisions of thimble/lugs and making provisions of vision glasses for meter readings, one spare MCCB compartment, and including PCC on 1:2:4 type B-1 for fixing meter cabin at old meter cabin place complete all as specified and as directed comprising of the following :- Make:- ABB/Legrand/Electro power control/L&T
(a) MCCB 100A, 4 pole, 415 volt, thermal magnatic release type, Ics=100% Icu, 25 kA - 01 Nos, Cat No-4200 55 of Make-Legrand/Siemens/L&T/Schneider. (b) MCCB 63A, 4 pole, 415 volt, thermal magnatic release type, Ics=100% Icu, 25 kA-02 Nos, Cat No-4200 53 of Make-Legrand/Siemens/L&T/Schneider. (c) Supply & fix of single phase smart meter , tamper proof, static meter of class 1.0, 240V, 50Hz, 10-60A anti temper feature as per IS 16444. - 10 Nos. Make L&T/Elmeasure/Panasonic (Anchor)/Siemens (d) MCB SPN 32 Amps- 10 Nos Make-Legrand Cat No-4086 17 or eqivalent to L&T/Schnider/ABB. (e) Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V, A, F, PF, KW, kVAR, kWH etc of make :- L&T, Cat Ref -WL441010OOOO-01 set or equivalent in Legrand/Schnieder/ABB. (f) Phase indicator lamp R,Y & B - (01 Set of three). (g) Copper Bus bar, 200 Amps Rated - R,Y,B & N - (01Set of four). (h) Reconnecting of submain cable 2 core 4/ 6 Sqmm copper conductor with outgoing of energy meter. (i) Making good the disturbed surface of meter cabin room if any damages occures during shifting of panel. Note :- Before fabrication of panel the contractor has to take approval from accepting officer on drawing.
All as per Item No 60.00 above but comprising of the following :- (a) MCCB 63A, 4 pole, 415 volt, thermal magnatic release type, Ics=100% Icu, 25 kA-02 Nos, Cat No-4200 53 of Make-Legrand/Siemens/L&T/Schneider (b) MCB SPN 32 Amps- 10 Nos Make-Legrand Cat No-4086 17 or eqivalent to L&T/Schnider/ABB (c) Supply & fix of single phase smart meter , tamper proof, static meter of class 1.0, 240V, 50Hz, 10-60A anti temper feature as per IS 16444. - 10 Nos. Make L&T/Elmeasure/Panasonic (Anchor)/Siemens (d) Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V, A, F, PF, KW, kVAR, kWH etc of make :- L&T, Cat Ref -WL441010OOOO-01 set or equivalent in Legrand/Schnieder/ABB. (e) Phase indicator lamp R,Y & B - (01 Set of three). (f) Copper Bus bar, 100 Amps Rated - R,Y,B & N - (01Set of four). (g) Reconnecting of submain cable 2 core 4/ 6 Sqmm copper conductor with outgoing of energy meter. (h) Making good the disturbed surface of meter cabin room if any damages occures during shifting of panel. Note :- Before fabrication of panel the contractor has to take approval from accepting officer on drawing.
Taking out old u/s and Supply, installing, testing and commissioning of LT feeder pillar box factory made cubical outdoor type, fabricated out of 2.00 mm thick CRCA sheet with angle iron base frame made of 40x40x6mm, 45cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415V 3 phase 4 wire weather proof with IP-66 protection, with separate hinge door for each compartment for incoming and out going MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with copper busbar (TPN), suitable double compression copper cable glands complete in all respect for bay work station and including provn of the following:- Make:- ABB/Legrand/Electro power control/L&T
(a) S&F MCCB 100 Amps, 4 Pole, 25 kA, thermal magnetic release, Ics=100% Icu - 01 Nos,
(b) S&F MCCB 63 Amps, 4 Pole, 16 kA, thermal magnetic release, Ics=100% Icu - 01 Nos,
(c) S&F RCBO's 63 Amps, 4 Pole 300mA - 01 Nos,
(d) S&F MCB SPN 40 Amps, 10 kA, - 01 Nos,
(e) Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V,A,F,PF,KW,kVAR,kWH etc of
(f) Phase indicator lamp R,Y & B (Set of 3)- 01 Set
(g) S&F Copper Bus bar 250 Amps of suitable size, all are in equal size - Set 1(R, Y, B, N)
Note: All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engr-in-Charge.
Supply and installation of Smart Single Phase Meter with the following specifications: (i) AC Single phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC standards with inbuilt 865-867 MHz Radio Frequency communication facility with self-healing Mesh network with defalult and on demand display, biling date generation facility, anti-tamper features. Microprocessor and LED/LCD based circuitry. (ii) Meter should support the following data : 30 min instaneous data for voltage, current, power factor, power, cumulative energy and frequency, 30 load survey date for energy, mopntly billing survey for cumulative energy and Max Demand. (iii) Meter should have connect/disconnect functionality operable from prepaid billing software. (iv) The meter should support open communication protocol DLMS with the software. MAKE: Secure, L&T, Schneider and HPL,Elmeasure. Note: (a) The contractor would be responsible from removing the existing meter, noting down the reading and depositing it with the MES. (b) It would be possible to run the meter in both prepaid and postpaid mode. (c) The meters would carry 5 year warranty.
S & F cable PVC insulated, PVC sheathed, armoured, FRLS, 1100V grade, 2 core 6 sqmm stranded copper conductor electric cable laid on wall/ roof/ duct complete with proper saddling and connecting to DBs with glands including taking out existing unserviceable cable complete all as specified.
M & L for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth strip 32 X 6mm by means of bolts, nuts and washers of galvanized iron or steel upto the test point all as shown in electrical plate No.3 of SSR Part-I connected toExisting earth strip including PCC earth pit with CI cover, GI funnel with wire mesh, GI protection pipe of 40 mm dia for earth lead and 20mm GI pipe for watering, excavation and earth work in any type of soil, filling the pit with charcoal and common salt surrounding the earth plate complete all as specified and directed by Engr-in-Charge including testing on completion.
M&L of aluminium strip 25x3.15mm with saddles and fixing screws etc. for roof conductors above ground.
M&L of test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex head screw
M&L scrapping old worn out paint from complete indoor type meter cabin panels and painting with one coats of synthetic enamel paint (incl front door in side and indl compartment outer side etc also) over a coat of primer and spray painting complete including fixing sticker danger sign board suitable for LT panel board and replacement of brocken glass of any size all as specified and as directed by engr-in-charge.
M & L for snap-on trunking system including cover, angles bends and all accessories and fitting of size 50x80 mm fixing on wall complete all specified and directed. Make: Legrand/Obbo/Honeywell
Excavation in trenches not exc 1.5 mtr wide and not exc1.5 mtr in depth for laying of cables etc. in any type of soil and getting out all as specified and directed by Engineer-in-Charge. Note : Rate includes removing of paver blocks carefully and stack properly for refixing after laying of cables .
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils.
Removing excavated material from the site of work and transporting out of Station/site of work suitable to the contractor all as specified.
Supply, filling, spreading levelling and well ramming the river sand around cable in trenches for cable cushioning all as specified and directed.
Material and labour for 60 mm thick coloured interlocking paver tiles/ blocks, lacquer finish of size 250x250 mm having compressive strength of 35N/Sqmm, zig-zag (uni-paver) shape in flooring tested as per IS : 15658-2006, with and including layer of 50 mm thick natural river sand bed compacted complete as specified and directed.
Supply, laying un-reinforced precast concrete cable cover class LV type 1 flat size 250mm x 150 mmx 40 mm.
Cutting existing road surfaces or hard standing 0.45 mtr depth (22 thick comprising bituminuous topping) for laying of pipes/cables and making good disturbed surfaces to match with existing surfaces.
Material and labour for cement concrete type C-2, 1:3:6 (40mm graded stone aggregate), for coping and finished surface without using extra cement.
Supplying and laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size 400 sqmm 3.5 core laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles and taking out old u/s damaged cables.Make : Finolex/Havells/Polycab.
All as per Item No-78.00 here in before but of sizes, 300 sqmm, 3.5 core.
All as per Item No-78.00 here in before but of sizes, 240 sqmm, 3.5 core.
All as per Item No-78.00 here in before but of sizes, 185 sqmm, 3.5 core.
All as per Item No-78.00 here in before but of sizes, 150 sqmm, 3.5 core.
All as per Item No-78.00 here in before but of sizes, 120 sqmm, 3.5 core.
All as per Item No-78.00 here in before but of sizes, 95 sqmm, 3.5 core.
All as per Item No-78.00 here in before but of sizes, 70 sqmm, 3.5 core.
M&L for 110mm dia High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, for road crossing of cable or for cable protection laid in trenches or above ground surface all as specified and directed.
All as per Item No-86.00 here in before but of HDPE sizes 90mm.
All as per Item No-86.00 here in before but of HDPE sizes 75mm.
M&L for GI pipe ,light grade 100mm dia for road crossing or in hard standing for protection of cable above or under ground surface including taking out old one all as specified and directed.
M &L for DWC (Double wall Corrugated) HDPE Pipe including accessories for road crossing of Size 100/110 mm.
Supply, installing, testing and commissioning of LT feeder pillar box factory made cubical outdoor type, slopy canopy fabricated out of 3.15mm thick CRCA sheet with angle iron base frame made of 40x40x6mm, 45cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415V 3 phase 4 wire weather proof with IP-66 protection, with separate hinge door for each compartment for incoming and out going MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with copper busbar (TPN), suitable double compression copper cable glands complete in all respect for bay work station and including provn of the following:- Make of panel and MCCB:- ABB/Legrand/Siemens.
(a) S&F MCCB 630 Amps, 4 Pole, 36 kA, thermal magnetic release, Ics=100% Icu - 01 Nos,
(b) S&F MCCB 200 Amps, 4 Pole, 25 kA, thermal magnetic release, Ics=100% Icu - 06 Nos,
(c) S&F MCCB 100 Amps, 4 Pole, 16 kA, thermal magnetic release, Ics=100% Icu - 02 Nos,
(d) S&F MCB SPN 32 Amps, 10 kA, - 05 Nos,
(e) Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V,A,F,PF,KW,kVAR,kWH etc of
(f) Phase indicator lamp R,Y & B (Set of 3)- 01 Set
(g) S&F Copper Bus bar 800 Amps of suitable size, all are in equal size - Set 1(R, Y, B, N)
(h) S & F sheet metal enclosure with plug , socket and MCB 20 Amps complete all as direcred.
Note: All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge.
All as per Item No 91.00 above but comprising of the following :-
(a) MCCB 400A, 36KA, FP withThermal magnetic release,lcs=100% lcs -01 Nos,
(b) MCCB 200A, 25KA, FP withThermal magnetic release,lcs=100% lcs -01 Nos,
(c) MCCB 100Amp,16KA, FP with Thermal magnetic release, lcs=100% lcs-04 Nos,
(d) MCCB 63Amp,16KA, 4P with Thermal magnetic release, lcs=100% lcs-03 Nos
(e) Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V,A,F,PF,KW,kVAR,kWH etc of
(f) Phase indicator lamp R,Y & B (Set of 3)- 01 Set
(g) Analog Time switch Micro Rex QT31 - 01 Nos
(h) Power Contactor 63A, 4 NO Contactor - 01 Nos
(j) S&F Copper Bus bar 600Amps of suitable size, all are in equal size - Set(R,Y,B,N)
(k) S & F sheet metal enclosure with plug , socket and MCB 20 Amps complete all as direcred.
All as per Item No 91.00 above but comprising of the following :-
(a) MCCB 200A, 25KA, FP withThermal magnetic release,lcs=100% lcs -01 Nos
(b) MCCB 63A, 16KA, FP withThermal magnetic release,lcs=100% lcs -04 Nos
(c) S&F MCB DP 40 Amps, 10 kA, - 04 Nos
(d) Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V,A,F,PF,KW,kVAR,kWH etc of
(e) Phase indicator lamp R,Y & B (Set of 3)- 01 Set
(f) S&F Copper Bus bar 200Amps of suitable size, all are in equal size - Set(R,Y,B,N)
(g) S & F sheet metal enclosure with plug , socket and MCB 20 Amps complete all as direcred.
All as per Item No 91.00 above but comprising of the following :-
(a) ACB 800A, 50KA, FP withThermal magnetic release,lcs=100% lcs -01 Nos,
(b) MCCB 630A, 36KA, FP withThermal magnetic release,lcs=100% lcs -01 Nos,
(c) MCCB 100Amp,25KA, FP with Thermal magnetic release, lcs=100% lcs-05 Nos,
(e) Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V,A,F,PF,KW,kVAR,kWH etc of
(f) Phase indicator lamp R,Y & B (Set of 3)- 01 Set
(g) S&F Copper Bus bar 1200Amps of suitable size, all are in equal size - Set(R,Y,B,N)
(h) S & F sheet metal enclosure with plug , socket and MCB 20 Amps complete all as direcred.
Note: All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge.
All as per Item No 91.00 above but comprising of the following :-
(a) ACB 800A, 50KA, FP withThermal magnetic release,lcs=100% lcs -03 Nos,
(b) Change over switch 800A, 50KA, FP -01 Nos
(c) MCCB 100Amp,25KA, FP with Thermal magnetic release, lcs=100% lcs-05 Nos,
(d) Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V,A,F,PF,KW,kVAR,kWH etc of
(e) Analog Time switch Micro Rex QT31 - 01 Nos
(f) Power Contactor 63A, 4 NO Contactor - 02 Nos
(g) Phase indicator lamp R,Y & B (Set of 3)- 02 Set
(h) S&F Copper Bus bar 1200Amps of suitable size, all are in equal size - Set(R,Y,B,N)
(j) S & F sheet metal enclosure with plug , socket and MCB 20 Amps complete all as direcred.
All as per Item No 91.00 above but comprising of the following :-
(a) MCCB 630A, 36KA, FP withThermal magnetic release,lcs=100% lcs -01 Nos,
(b) MCCB 400A, 36KA, FP withThermal magnetic release,lcs=100% lcs -01 Nos,
(c) MCCB 250Amp,36KA, FP with Thermal magnetic release, lcs=100% lcs-01 Nos,
(d) MCCB 100Amp,16KA, FP with Thermal magnetic release, lcs=100% lcs-06 Nos,
(e) Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V,A,F,PF,KW,kVAR,kWH etc of
(f) Phase indicator lamp R,Y & B (Set of 3)- 01 Set
(g) S&F Copper Bus bar 800Amps of suitable size, all are in equal size - Set(R,Y,B,N)
(h) S & F sheet metal enclosure with plug , socket and MCB 20 Amps complete all as direcred.
Note for ser item No 91.00 to 96.00 : Before fabrication of panel, the contractor has to take approval from accepting officer on drawing.
S&F in repair, MCCBs in existing FP/panel, connecting to bus-bar with all connecting accessories and modification in busbar (if Necessary), connection complete and testing after completion, all as specified and directed, of following capacities :-
(a)MCCB 63 Amps,16 kA,FP, 50 Hz,Thermal magnetic release,lcs=100% lcu.
(b)MCCB 100 Amps,16 kA,FP,50 Hz,Thermal magnetic release,lcs=100% lcu.
(c)MCCB 160 Amps,25 kA,FP,50 Hz,Thermal magnetic release,lcs=100% lcu.
(d)MCCB 200 Amps,25 kA,FP,50 Hz,Thermal magnetic release,lcs=100% lcu.
(e)MCCB 250 Amps,36 kA,FP,50 Hz,Thermal magnetic release,lcs=100% lcu.
(f)MCCB 320 Amps,36 kA,FP,50 Hz,Thermal magnetic release,lcs=100% lcu.
(g) MCCB 400 Amps,36 kA,FP,50Hz,Thermal magnetic release,lcs=100% lcu.
(h) MCCB 630 Amps,36 kA,FP,50Hz,Thermal magnetic release,lcs=100% lcu.
(j) MCB 800 Amps,50 kA,FP,50Hz,Thermal magnetic release,lcs=100% lcu.
(k) MCB 1000 Amps,50 kA,FP,50Hz,Thermal magnetic release,lcs=100% lcu.
(l) MCB 1250 Amps,50 kA,FP,50Hz,Thermal magnetic release,lcs=100% lcu.
(m) MCB 1600 Amps,50 kA,FP,50Hz,Thermal magnetic release,lcs=100% lcu.
S&F on load changeover switch having capacity 63/100 Amps,415V 4 Pole with open execution with front handle
M&L for shifting of LT panel of any size with all accessories and fixing it to other location as directed by Engr-in-Charge at site, connecting cable connection with connecting accessories, incl foundation in PCC 1:3:6 type C2 all as specified and directed.
M&L for straight through joint, heat shrinkable tubular type of size 25 to 50 sqmm,3.5 core, 1100 volts grade complete all as specified and directed.Make- M-Seal/3MDenson
All as per Item No-99.00 here in before but of sizes, 70 to 120 sqmm, 3.5 core.
All as per Item No-99.00 here in before but of sizes, 15 to 185 sqmm, 3.5 core.
All as per Item No-99.00 here in before but of sizes, 240 to 300 sqmm, 3.5 core.
NOEL ENGINEERS
Darpan Construction
SHREE JAGDISH FURNITURE CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .