Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹6.2 LAccepted-AOC | L 1 | Accepted-AOC As per the chart generated L1 is accepted and AOC issued to L 1 | |
| 2 | L 2₹6.9 L+₹66,968 (10.8%)Rejected-Finance NO 23 JEEVANANDAM STREET PUDUCHERRY 605 001 | PUDUCHERRY | PUDUCHERRY | PUDUCHERRY | 605001 | L 2 | Rejected-Finance Second Least | |
| 3 | L 3₹7.2 L+₹96,480 (15.5%)Rejected-Finance PUDUCHERRY | KARAIKAL | PUDUCHERRY | 609607 | L 3 | Rejected-Finance Third Least | |
| 4 | L 4₹7.7 L+₹1.5 L (23.7%)Rejected-Finance NO 14 MARIAMMAN KOIL STREET EAST PANITHITTU PUDUCHERRY 607 402 | PONDICHERRY | PUDUCHERRY | 607402 | L 4 | Rejected-Finance Forth Least | |
| 5 | Not Admitted-Fee/PreQual/Technical NO 14 VINAYAGAR KOIL STREET KURUMBAPET PUDUCHERRY 605 009 | PONDICHERRY | PUDUCHERRY | 605009 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
Closing Date
1 Jul 2021, 4:00 pmClosed
Executive Engineer, SBDI, PWD, Puducherry.
Executive Engineer, SBDI, PWD, Puducherry.
Construction of Yoga Hall and compound wall at Sub Centre at J.J.Nagar, Reddiarpalayam, Puducherry.
2021_PWDC1_8224_1
04/SBDI/2021-22/3
Open Tender
Civil Works
Item Rate
90 days
Puducherry
Please refer Tender documents.
2 documents required · 2 mandatory
₹525
Exempted
16 Sept 2021
25 Jun 2021
2 Jul 2021
25 Jun 2021
1 Jul 2021
25 Jun 2021
Amount
Earthwork in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed , within a lead of 50m - all kinds of soil.
Filling available excavated earth (excluding rock) in trenches,plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5m.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30cm measured at a height of 1m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plinth level - 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete , excluding the cost of centering, shuttering , finsishing and reinforcement - All work upto plinth level 1:1.5:3 (1cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters , buttresses, plinth and string courses , fillets, columns , pillars,piers, abutments, posts and struts etc.upto floor five level excluding cost of centering,shuttering,finishing and reinforcement:1:1.5:3 (1 cement : 1.5coarse sand : 3 graded stone aggregate 20mm nominal size)
Centering and shuttering including strutting, propping etc and removal of form for - foundations, footings, bases of columns etc for mass concrete.
Centering and shuttering including strutting, propping etc and removal of form for - Lintels, beams, plinth beams, girders, bressumers and catilevers.
Centering and shuttering including strutting, propping etc and removal of form for - Columns, Pillars, Piers, Abutments, Posts and Struts.
Providing , hoisting and fixing upto floor five level precast reinforced cement concrete in small lintels not exceeding 1.5 m clear span upto floor five level, including the cost of required centering, shuttering but excluding the cost of reinforcement, with 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level - Thermo -Mechanically treated bars (TISCON / VIZAG / IISCO / SAIL / JSW) Fe - 415 or more.
Brick work with common burnt clay F.P.S. (non modular ) bricks of class designation 7.5 in foundation and plinth in - cement mortar 1:4 (1 cement : 4 coarse sand).
Brick work with common burnt clay F.P.S (non modular ) bricks of class designation 7.5 in superstructure above plinth level upto floor five level in all shapes and sizes in - cement mortar 1:4 ( 1 cement : 4 coarse sand).
Brick work with common burnt clay F.P.S (non modular ) bricks of class designation 7.5 in superstructure above plinth level upto floor five level in all shapes and sizes in - cement mortar 1:6 ( 1 cement : 6 coarse sand).
Steel work in built up tubular (round,square or rectanglar hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete - electric resistance or induction butt welded tubes.
Steel work welded in built up sections / framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required - in gratings, frames, guard bar, ladder, railings, brackets,gates and similar works.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete - 40mm thick with 20mm nominal size stone aggregate.
Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including finishing complete.
Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes - 110 mm diameter.
Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - bend 87.5 degree - 110 mm bend.
Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - shoe (plain) - 110mm shoe.
Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc., complete - 110mm.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.5mm (+0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both sides of the sheet and polyster top coat 15-18 microns using self drilling / self tapping screws complete - Crimp curve.
Providing and fixing colour coated galvalume sheet of 550 M.P.A. yield of AZ 150 strength formed as per patterned steel rib profile with the depth of 31 mm pitch of 250 mm and overall width of 1060 mm and thickness 0.5mm with required J or C hook bolts and nuts 8mm dia G.S.paint and working etc., complete excluding the cost of purlin, rafter and truss etc.,
12mm cement plaster of mix -1:6 ( 1 cement : 6 fine sand).
15mm cement plaster on the rough side of single or half brick wall of mix - 1:6 (1cement : 6 fine sand).
cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement - 20mm cement plaster.
Applying one coat of water thinnable cement primer of approved brand and manufacturer on wall surface - water thinnable cement primer.
Finishing walls with textured exterior paint of required shade - New work (Two or more coats applied @ 3.28 ltr / 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm.
Applying priming coat - with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron / steel works.
Painting with synthetic enamel paint of approved brand and manufacutre to give an even shade - Two or more coats on new work.
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq.metres and under including cutiing the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 metres lead - with cement mortar 1:4 (1 cement : 4 coarse sand).
Flush pointing with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement for flat tile bricks on top of mud phaska - with F.P.S. brick tiles.
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scrarches etc.complete.
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc complete.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade - One or more coats on old work.
Finishing walls with water proofing cement paint of required shade - old work (one or more coats applied @2.20 kg/10sqm) over priming coat of primer applied @0.8 litres / 10 sqm complete including cost of priming coat.
Finishing walls with premium acrylic smooth exterior paint with silicon additives of required shade - old work (two or more coats applied @ 1.43 ltr / 10 sqm) over existing cement paint surface.
Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same.
Cleaning of under ground sump , Over Head R.C.C. tank (independent staging) including disposal of slit and rubbish . The cleaning shall consist following operations: i) Tank shall emptied of water by pumping and bottom shall be cleaned of slit and other deposits. Ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. Iii) Chlorination of RCC internal surface by liquid Chlorine.iv) the treated surface shall be dried using air jetting and all loose particles shall be removal from the surface.v)Finally the surfcae shall be treated with ultraviolet radition etc.
Demolishing R.C.C work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead.
Supplying fixing and commisioning of Suguna / Texmo / Sharp 1 HP monoblock pumpset slow speed single phase motor. The rate include the cost of pumpset, pumpset fixing in position and test run etc.complete.
Acid cleaning for the existing Mosaic floors , glazed tiles work and removing the stains and decays to give a glassy look etc complte (The Acid used shall be 32% concentrated hydrochloric acid after taking on the precautionary measures).
Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete - flexible pipe - 32mm dia.
Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing . This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall ) - 20mm nominal outer dia pipes.
Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall ) - 32mm nominal outer dia pipes.
Providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete - 20mm nominal bore.
Providing and fixing gun metal non -return valve of approved quality (screwed end) - 32 mm nominal bore -Vertical.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI: 12701 marked , with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank - Circular Tank
Providing and fixing C.P.brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms - 15 mm nominal bore.
Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 8931- 15 mm nominal bore.
Providing and fixing PTMT stop cock of approved quality and colour 20mm nominal bore, 89mm long, weighing not less than 88 gms.
Providing and fixing PTMT pillar cock of approved quality and colour - 15mm nominal bore, 107 mm long, weighing not less than110 gms.
Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour - 20 mm nominal bore, weighing not less than 40 gms.
Providing and fixing in position G.I. union (UNIQUE/R Brand/HB Brand/UI Brand) conforming to IS 1239 part II and ISI marked, including labour charges for jointing, jointing materials etc, complete-20 mm dia.
sabastinmartial
Naidu Engineering Works
D Boopalan
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .