Odisha
Rate Contract for Construction of 11KV & LT Line under PMJUGA & PM-AJAY
TPNODL-OT-2026-27--2500001311
TPNODL/OT/2026-27/2500001311 dtd.06.11.2026
Limited Tender
construction
Tender Notice
Odisha
₹1,000
TP Northern Odisha Distribution Limited (TPNODL)
₹1,000
Yes
Online / as specified in tender document
7 Nov 2026
7 Nov 2026
20 Nov 2026
TATA POWER NORTHERN ODISHA DISTRIBUTION LIMITED
SCHEDULE _Supply of Equipment/Materials (Line) Price Break-up against NIT /TPNODL/PM JUGA, PM AAGY, BGJY New Connection & Solar Defunct Case.
DETAIL REQUIREMENT (To be quoted)
Part A. Supply of Materials Required for Construction of 11kV line, Sub-Station, LT Line and Meter
1 Material Code Supply of Material required for Construction of 11kV OH line with Covered Conductor, as per technical specification and scope of work. UoM Proposed Qty.
1 601000828 WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.) EA 7604.0
2 601000603 9 Mtr. long 300 Kg. PSC Pole (For Raising of LT ABC) EA 20744.0
3 401000484 3Cx400mm2 11KV XLPE Cable (Armoured), A2XWY MTR 7600.0
4 401000859 Heat shrinkable jointing kit for 3Cx 400mm2 11 KV XLPE Cable(outdoor type) EA 16.0
5 401000860 Heat shrinkable jointing kit for 3Cx400 mm2 11 KV XLPE Cable(straight type) EA 36.0
6 401000673 Conductor Covered 11KV 100 Sqmm AAA MTR 680797.3
7 601001762 Dead end assembly with crosss arm accessories for Covered Conductor EA 4524.0
8 601000797 IPC for 100 sq.mm AAA conductor (For covered conductor) EA 4524.0
9 601000792 Non Metallic Ties 11KV (For covered conductor) EA 21198.0
10 401000775 Midspan Joint for 100 Sqmm AAAC XLPE Covered Conductor EA 648.0
11 301000341 Gi Pipe Earthing 40mm. 3 Mtr. Long EA 2409.0
12 401000938 4x50+1x50+1x16 Sqmm LT AB Cable MTR 134463.4
13 401000277 3x50+1x35+1x16 Sqmm LT AB Cable MTR 263947.8
14 401000072 1x35+1x25 Sqmm LT AB Cable MTR 338990.5
15 601000524 Pole clamp for EYE hook for (XLPE Aerial bunched Cable) PAA 28486.0
16 601000190 EYE hook for XLPE Aerial bunched Cable EA 13437.0
17 601000070 Dead End Clamp suitable for messenger XLPE Aerial bunched Cable EA 13437.0
18 601000628 Suspension Clamp with EYE hook for ABC (25-70 sq.mm) EA 15049.0
19 401001003 Insulated piercing connector Type-B-main 16 to 95 sq.mm & Tap-16 to 95 sq.mm EA 31058.0
20 501000671 Cable 1.1kV AI 3.5Cx35 Sqmm Un-Armoured MTR 32500.0
21 601000189 LT Distribution Box Polycarbonate (10Way) EA 8019.0
22 601000586 LT Stay set Complete SET 6450.0
23 601000390 LT stay Clamp ( 1.40Kg/pair) PAA 6450.0
24 601000153 LT Stay insulator EA 6450.0
25 701000012 7/12 SWG GI stay wire, Grade -2 KG 77400.0
26 101000347 100 KVA , 11/ 0.4 KV (AL) Transformer BIS Energy level II EA 13.0
27 101000333 63 KVA , 11/ 0.4 KV (AL) Transformer BIS Energy level II EA 117.0
28 101000328 25 KVA , 11/ 0.4 KV (AL) Transformer BIS Energy level II EA 139.0
29 601000231 LT Distribution Box with MCCB, Aluminium Busbar of single Bay with kit kat fuse for 100 KVA S/S EA 13.0
30 601000187 LT Distribution Box with MCCB, Aluminium Busbar of single Bay with kit kat fuse for 63 KVA S/S EA 117.0
31 601000186 LT Distribution Box with MCCB, Aluminium Busbar of single Bay with kit kat fuse for 25 KVA S/S EA 139.0
32 401000306 4 Cx 150 mm2 LT XLPE Cable(Armoured) - FOR 100 KVA Trf. MTR 650.0
33 401000307 4 Cx 95 mm2 LT XLPE Cable(Armoured) - FOR 63 KVA Trf. MTR 5850.0
34 401000731 4 Cx 50 mm2 LT XLPE Cable(Armoured) - FOR 25 KVA Trf. MTR 6950.0
35 401000147 PG Clamp for 100 sq.mm AAA conductor EA 1614.0
36 301000006 AB Switch(11KV,200A.3pole,50Hz) "Vertical Type" SET 269.0
37 301000357 DD Fuse with Barrel (11KV.200A.3Pole) SET 269.0
38 301003643 10 AMP Fuse Link EA 807.0
39 301002185 DTR Name plate EA 538.0
40 501000064 GI Nut , Bolt & Washer of different size KG 35597.9
41 501000165 50x6mm GI Flat for earthing, 2.36kg/mtr. KG 33355.5
42 501000164 25x6mm GI Flat for earthing, 1.25kg/mtr. KG 5817.1
43 501000411 No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing KG 7215.7
44 601000029 11kv Local language Danger Plate, 1 no's. EA 7604.0
45 601000031 Local language LT Danger Plate, 1 no's. EA 20475.0
46 601000773 Back Clamp for danger Plate 25X3 mm. flat KG 10575.1
47 601000052 Top Channel 100X50X6mm, 9.56 KG/Mtr. KG 75149.8
48 501000090 GI Bracing Angle 50x50x6mm., 4.5Kg./mtr. KG 40754.2
49 501000093 Belting Channel 75X40X 4.8mm., 7.14KG/Mtr. KG 65577.8
50 601000067 Lightning Arrester(12KV,10KA) Station Class EA 831.0
51 601000152 11 KV V cross Arm (10.2 K.g. each ) EA 6352.0
52 Back Clamp GI Back Clamp for V cross arm (11KV) ( 0.85 kg each) EA 6352.0
53 601000465 F bracket 100x50X6 mm GI channel (2kg each) EA 6352.0
54 601000581 11 KV pin insulator polymer EA 22005.0
55 601000174 Disc insulator (B&S) 70 KN polymer EA 5331.0
56 601000197 H W fitting (B&S)70KN(3bolted) EA 807.0
57 601000420 H.T. stay set complete SET 3156.0
58 601000404 HT stay Clamp (1.9Kg/pair) PAA 3156.0
59 601000419 H.T. Stay Insulator Type-C EA 3156.0
60 501000406 7/10 SWG Stay Wire 15kg /stay KG 47340.0
61 601000593 Earthing of Support ( Coil Type ) EA 28348.0
62 501000448 GI Barbed wire/Anticlimbing device (3Kg /Pole) KG 83430.0
63 601000772 Back Clamp for anticlimbing device 25X3 mm. flat KG 33795.9
64 601000367 Single Phase Meter 1P 10-60 Amp With Box EA 23682.0
65 Meter Seal Polycarbonate Green Colour Seal EA 71046.0
66 Solar Standalone Solar EA 1823.0
Part B. Erection, Testing & Commissioning of Construction of 11kV line, Sub-Station, LT Line and Meter
1 Service Code Erection, Testing & Commissioning for Construction of 11kV OH line with Covered Conductor, as per technical specification and scope of work. UoM Proposed Qty.
1 Installation/Erection of 11 Mtr long, WPB-Pole including loading and unloading, transportation from site/tent upto 3 Km., excavation, refilling, flooding with water, ramming/compacting of foundation as per TPNODL specifications and drawing including removal & disposal of extra malba as per instruction of EIC. The scope of work include providing & laying of 1:1.5:3 , M20, concrete of size - 500(B)x500(W)X1800(H) , and cooping of 500(B)x500(W)x450(H), Scope of work also includes 5 days curing and zebra painting (In Black & Yellow Strips/Zebra) .As per drawing. As per TPNODL Specification. EA 7604.00
2 ITC of 9 MTR PSC Pole including loading and unloading, transportation from site/tent upto 3 Kms., excavation,Includes and civil work. The scope also includes providing of all civil material for concreting . Transportation, loading and unloading of Pole from Nearest division/store/site office to site(maximum upto 3KM), Excavation for grouting, including concreting as per standards and drawings.Concreting to be done with PCC-1:1.5:3. of size - 500x500x1500 Muffing and ,Padding 500x500x75mm. 500(B)x500(W)x300(H) Scope of work also includes 5 days curing and zebra painting (In Black & Yellow Strips/Zebra) as per drawing EA 20744.00
3 Supply & Laying of PIPE HDPE 200 MM DIA PN8 , PE 80 through HDD method .Scope of work also includes making Trenchless ducts with 200 mm Dia HDPE pipe casing using HDD machine including supply of HDPE pipe as per IS 4984, (Providing parabolic graph included in the scope) MTR 7300.00
4 Supply & Laying/Mounting and fixing of HDPE Pipe -200mm Dia ( PN-8,Grade PE-80)and sealing of the same for LT/HT Cables. Scope also includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe. (Excavation is excluded) MTR 200.00
5 Lay-1.1KV Cbl(16-630 sqmm)-Trench/Pipe As per TPNODL Specification. MTR 7600.00
6 BA will excavate the cable trench length by providing all necessary tool, Manpower, pump etc suitable for HT & LT Cable laying and Back fill the same earth soil BA will supply neccessry barricades at the excavation site. CUM 72.00
7 Earth Work-hard rock.Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and Engineer-in charge. Note- All kind of excavation work with different size for plinth, Structu re & other works will be considered under this line items Hard rock.%_1 CUM 30.00
8 Supplying and spreading, filling other works with fine sand under floors,ground etc as per EIC instruction. Scope of work also includes watering, ramming, consolidating and dressing complete and other works if required at site . CUM 12.00
9 Supply, laying & fixing of RCC type Precast slab any types of work( Cable Laying etc) including Caution tape, Sand as per approved drawing EA 200.00
10 Supply and Installation of cable Route marker including transportation from site/tent, excavation, refilling, disposing of malba, flooding with water, ramming/compacting of foundation as per specifications and drawing. EA 78.00
11 Demolishing stone rubble masonry manually/ RCC/BRICK WORK/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : In cement mortar. CUM 48.00
12 ITC of jointing kit of 11kV 3Cx 400 sq mm with Heat Shrink and providing jointing services as per Standards, GTP, Drawing and specifications. Approved Make- Raychem & 3M. (straight through) EA 36.00
13 ITC of jointing kit of 11kV 3Cx 400 sq mm with Heat Shrink and providing jointing services as per Standards, GTP, Drawing and specifications. Approved Make- Raychem & 3M. (Outdoor Termination) EA 16.00
14 Stringing of 11KV insulated Conductor size from 55sqmm to 100sqmm.etc.BA has to provide necessary Tools , manpower for stringing &Jumpering. MTR 680797.30
15 ITC of Dead end assembly with accessories for Covered Conductor EA 4524.00
16 ITC of 11 KV IPC, suitable for 100 sqmm covered conductor as per design EA 4524.00
17 ITC of Non Metallic Ties 11KV (For covered conductor) EA 21198.00
18 Fixing of Mid Span Compression Joints suitable for AAAC/ACSR Conductor. As per TPNODL Specification. EA 648.00
19 Installation of Earthing pipe with 40mm dia 3 Mtr long Class-B GI Pipe(Jindal/Tata/Sail/Rinl) without earth chamber. The Scope include to excavation & installation of incuding earthingpipe dia up to 100mm dia., Fixing of Nutbolt, 25 Kg Bentonide Power, connection & welding with incoming earth flat. Each pit resistance will be measured and recorded and shall be as per IS. the levelling & ramming of earth and removal of extra malba. The work to be executed as per TPNODL drawing & design EA 2409.00
20 ITC of LT AB Cable 4x50+1x50+1x16 Sqmm BA will provide necessary manpower, tools, machinery etc, ladder etc for stringing activities. As per TPNODL Specification. MTR 134463.41
21 ITC of LT AB Cable 3x50+1x35+1x16 Sqmm BA will provide necessary manpower, tools, machinery etc, ladder etc for stringing activities. As per TPNODL Specification. MTR 263947.80
22 ITC of LT AB Cable 1x35+1x25 Sqmm BA will provide necessary manpower, tools, machinery etc, ladder etc for stringing activities As per TPNODL Specification. MTR 338990.51
23 ITC of Pole Clamp for with all necessary nutbolt for fixing eye hook suitable different size of LT ABC Cable / Stay etc suitable for PSC pole. BA will provide necessary tool, manpower, nubolt as per TPNODL specification. EA 28486.00
24 ITC of Eye Hook for supporting of Dead end & Suspension LT ABC Cable. BA will provide necessary tool, manpower, nubolt as per TPNODL specification. EA 13437.00
25 ITC of Dead end clamp for stringing LT ABC Cable.BA will provide necessary tool, manpower, nubolt as per TPNODL specification. EA 13437.00
26 ITC of suspension clamp for stringing LT ABC Cable.BA will provide necessary tool, manpower, nubolt as per TPNODL specification. EA 15049.00
27 ITC of All type of Connector IPC, Connector. EA 31058.00
28 ITC of 1.1kV AlI 3.5Cx35 Sqmm Un-Armoured Cable, BA will provide necessary manpower, tools, machinery etc, ladder etc for stringing activities As per TPNODL Specification. MTR 32500.00
29 ITC of LTDB box in pole for releasing power supply to LT 1ph & 3ph consumer. Scope includes provide necessary GI clamp arrangement for fixing LTDB to pole.Termination of incoming & outgoing cable in LT Dist Box as per TPNODL Specification. EA 8019.00
30 ITC of Complete LT Stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts BA will do the excvation including excvation, supply of 0.5Cum cement concrete foundation 1:1.5:3 size ( 500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPNODL Drawing & Standard. EA 6450.00
31 ITC of 11/0.4kV, 100kVA 3-Phase Distribution Transformer on existing structure as per specification including loading, unloading,Testing of Transformer at Site. shifting/transportation from site /tent. Scope of work includes jumpering/connection at HT and LT side & Earthing Connections. EA 13.00
32 ITC of 11/0.4kV, 63kVA 3-Phase Distribution Transformer on existing structure as per specification including loading, unloading,Testing of Transformer at Site. shifting/transportation from site /tent upto15KM. Scope of work includes jumpering/connection at HT and LT side & Earthing Connections..BA will provide necessary control cable ferruling, control cable schedule, connectors, lugs & cable gland at both end of terminations of control cable. EA 117.00
33 ITC of 11/0.4kV, 25kVA 3-Phase Distribution Transformer on existing structure as per specification including loading, unloading, Testing of Transformer at Site.shifting/transportation from site /tent upto15KM. Scope of work includes jumpering/connection at HT and LT side & Earthing Connections..BA will provide necessary control cable ferruling, control cable schedule, connectors, lugs & cable gland at both end of terminations of control cable. EA 139.00
34 ITC of Outdoor Type LT Distribution Box with MCCB for 11/0.4kV,100kVA Three Phase Transformer on existing structure as per specification EA 13.00
35 ITC of Outdoor Type LT Distribution Box with MCCB for 11/0.4kV,63kVA Three Phase Transformer on existing structure as per specification EA 117.00
36 ITC of Outdoor Type LT Distribution Box with MCCB for 11/0.4kV,25kVA Three Phase Transformer on existing structure as per specification EA 139.00
37 ITC of LT XLPE Cable(Armoured) - form DTR to Distribution Box. BA will provide necessary manpower, tools, machinery etc, ladder etc for stringing activities. As per TPNODL Specification. MTR 13450.00
38 ITC of PG Clamp for 100 sq.mm AAA conductor EA 1614.00
39 ITC of at 11KV 3pole AB Switch 200Amp in existing structure providing necessary manpower, nutbolt,Terminal connection, earthing connection, site minor modification, alignment, welding, cutting of Ms channel & AB switch pipe etc as per site requirement ,as per EIC & drawing SET 269.00
40 ITC of DO Fuse with link wire set in existing structure providing necessary manpower, nutbolt,Terminal connection, earthing connection, site minor modification, welding,Ms channel etc SET 269.00
41 ITC of Installation of LT/HT Danger Board along with back clamp as per specification EA 28348.00
42 ITC of Barbed Wire with clamp (to avoid the climbing at pole) for 9Mtr/11Mtr/13 Meter pole/H Pole as per TPNODL specification and drawing. EA 28348.00
43 Fixing of complete 11KV line Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts BA will do the excvation including excvation, supply of 0.5Cum cement concrete foundation 1:1.5:3 size ( 500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPNODL Drawing & Standard. EA 3156.00
44 ITC of Different type of channel & angle, installation,welding & fabication work of different size GI Channel (100x50x6mm, 75x75x6mm, 50x50x6mm,75X40X4.6mm, etc) as per size requirement KG 181481.76
45 ITC of Different type of channel & angle, installation,welding & fabication work of different size Flat (25x6 & 50x6) as per size requirement KG 39172.66
46 Installation of different size of GI Nut ,bolt & washers, As per TPNODL Specification. KG 35597.90
47 Erection of earthing coil (8 SWG wire dia) along with 8 SWG Wire, Nut -bolt & other accessories to earth the pole as per TPNODL Design .Scope of work also includes the excavation of earth upto 1.2 Mtr depth for erection of earthing coil and disposal of extra malba up to 150Mtr as EIC instructions.As per TPNODL Specification. EA 28348.00
48 Installation of 11KV Polymer Insulator along with Nutbolts for 11KV line.Nutbolts will be paid separately EA 22005.00
49 ITC of Disc insulator (B&S) 70 KN polymer EA 5331.00
50 ITC of H W fitting (B&S)70KN(3bolted) EA 807.00
51 Installation of V cross arm/Top bracket with back clamp on pole along with Nut bolts for 11KV line. Nutbolts will be paid separately, As per TPNODL Specification. EA 6352.00
52 ITC of the Lighting arrester (single phase) in existing structure providing necessary manpower, nutbolt,Terminal connection, earthing connection, site minor modification, welding,Ms channel etc As per TPNODL Specification. EA 831.00
53 SITC including loading , unloading & transportation of TIE PLASTIC BLACK SIZE 7.6 MM X 150MM as per specification. EA 11061.00
54 SITC including loading , unloading & transportation of LT AB Cable End Cap as per specification EA 7374.00
55 ITC of All types of GI Wire for LV Line MTR 7215.74
56 SITC of installation including loading , unloading & transportation of HDPE Pipe - 40 mm dia for Wire/Cable protection. Scope also include supply and erection of all required accessories for fixing it with pole/structure such as GI clamp (12X3 mm) at every interval of 1.5 mtr ,Nut & Bolt ,sealing of the pipe ,collar fixing as per specification. MTR 4035.00
57 SITC of Laying/Mounting and fixing of HDPE Pipe -110mm dia ( PN-4,Grade PE-80)and sealing of the same for LT/HT Cables. Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe. (Excavation is excluded) MTR 4035.00
58 SITC of Wooden Cleat set, MS strip and hard ware for fixing cable including painting one coat of red oxide & two coats of black paint for Distribution Transformer. Scope also includes supply of ISI marked paint. (Price per set ) Set 269.00
59 SITC including loading, unloading & transportation of Plaster of Paris (PoP) Kg 672.50
60 SITC of AL Lugs with Double Compresion Gland suitable for 50- 150 sq mm cable/conductor, Crimping with cable and Fixing/connecting as per Specification .Scope also include supply and erection of PVC Tape as per voltage requirement.The crimping shall be done with haudralic crimping machine. EA 4035.00
61 BA will supply & Install Jointing KIT Heat Shrinkable , Approved Make for Jointing Kit- Raychem or 3M for 1.1KV XLPE Cable 50Sqmm-120 SQMM XLPE 4 core cable .No extra rate will be paid for Jointing services. Strainght through joints EA 256.00
62 BA will supply & Install Jointing KIT Heat Shrinkable , Approved Make for Jointing Kit-Raychem or 3M for 1.1KV XLPE Cable 120Sqmm-240 SQMM XLPE 4 core cable.No extra rate will be paid for Jointing services.Strainght through joints EA 13.00
63 Supplying and spreading, filling other works with fine sand under floors,ground etc as per EIC instruction. Scope of work also includes watering, ramming, consolidating and dressing complete and other works if required at site . CUM 269.00
64 Supplying, Laying, spreading and compacting with hand roller stone aggregate of specified sizes: 63 mm to 45 mm size stone aggregate to WBM specifications in uniform thickness, hand picking to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . .Scope of work also includes of jungle such as grass,small tree,plant etc. CUM 403.50
65 SITC of Boundary Fencing with Gate as per specifications. Civil works including site clearing and vegetation removal, earthwork excavation, sand filling, stone soling, PCC works, brick masonry, internal plastering, painting works, fabrication and erection of structural steel, installation of MS gates, and GI barbed wire fencing complete in all respects as per approved specifications and drawings. RM 4842.00
66 ITC of Single Phase Meter with Box (10-60) -1 No & Meter Seal-3 Nos. SET 23682.00
67 SITC Each Service connection kit with following items i)Service cable(4 sq. mm twin core PVC Al. Wire - up to 25 Mtr ) ii) 10 SWG G.I. supporting Wire (75 gm/Mtr) (Insulated)-up to 25 Mtr. iii)PorceilineSpool - 02 nos., Link Clip - 10 nos. iv) GI Bend Pipe (bracket) 20 mm dia.(NB) 2.8 Mtr.long - 1 no. SET 23682.00
68 SITC House Wiring Materials for each HH i) Miniature Circuit Breaker 16A-2 nos, ii) 4 x4"Wooden/PVC Board -1no, iii)8"x 6"Wooden/PVC Board along with 2 no. 5Amp Switch & 1 no. 5Amp Socket, iv) 6"x4" Wooden/PVC Board-1 no, SET 23682.00
69 SITC Earthing(Coil Earthing-1no & Insulated G.I. Wire-400gm/earthing) for earting of 1 PH meter No 23682.00
70 SITC LED Lamp 9Watt- 1 Nos. No 23682.00
Part C. For additional work as per requirment
1 Detail Survey of HT/LT lines profile plotting, pole spotting and preparation of pole schedule and GIS Mapping, indexing/numbering of Poles as per GIS format, scope also include site survey for GIS indexing as per requirement. Km 880.00
2 Loading, transportation and Unloading of JOIST /WPB/ RLP & other type of poles of 10-11 Mtr long from store/site to other site or vice versa (above 3 km upto 10 km) - price per Pole.Note:- This line items applicable when full trailer pole shifting not required. EA 496
3 Transportation of various items from TPNODL store/site to other site or vice versa in TPNODL operational area - Trailer with labours as required (price per trip). Scope of work also include loading and unloading of materials heavy items like, 14 mt Rail Pole, PCC Pole, HT Panel, Transformer, Cable Drum, LT Board. Item whose loading& unloading is to be done with crane, charges for crane will be paid separately.(Full Trailer) upto 70 Km. EA 992
4 Transportation of various items from store/site to other site or vice versa in operational area - Trailer per KM beyond 70KM with labours as required (price per trip). Scope of work also include loading and unloading of materials heavy items like, 14 mt Rail Pole, PCC Pole, HT Panel, Transformer, Cable Drum, LT Board . Item whose loading& unloading is to be done with crane , charges for crane will be paid separately. (Full Trailer) KM 496
5 Transportation of various items from TPNODL store/site to other site or vice versa in TPNODL operational area - Tractor with labours as required (price per trip). Scope of work also include loading and unloading of materials heavy items like, Rail Pole, PCC Pole, HT Panel, Transformer, Cable Drum, LT Board. Item whose loading& unloading is to be done with crane, charges for crane will be paid separately.upto 40.0 Km EA 1488
6 Transportation of various items from store/site to other site or vice versa in operational area - Tractor per KM beyond 40 KM with labours as required (price per trip). Scope of work also include loading and unloading of materials heavy items like, Rail Pole, PCC Pole, HT Panel, Transformer, Cable Drum, LT Board . Item whose loading& unloading is to be done with crane , charges for crane will be paid separately. KM 496
7 Transportation of various items from TPNODL store/site to other site or vice versa in TPNODL operational area - Full body Truck with labours as required (price per trip). Scope of work also include loading and unloading of materials except heavy items like HT Panel, Transformer, Cable Drum, LT Board where loading, unloading is to be done with crane and will be paid separately (Full Truck), upto 70.0 Km EA 1488
8 Transportation of various items from store/site to other site or vice versa in operational area - Full Body Truck per KM beyond 70 KM with labours as required (price per trip). Scope of work also include loading and unloading of materials heavy items like, Rail Pole, PCC Pole, HT Panel, Transformer, Cable Drum, LT Board . Item whose loading& unloading is to be done with crane , charges for crane will be paid separately. KM 496
9 Transportation of various items from TPNODL store/site to other site or vice versa in TPNODL operational area - Tempo 407 with labours as required (price per trip). Scope of work also include loading and unloading of materials except heavy items like HT Panel, Transformer, Cable Drum, LT Board where loading, unloading is to be done with crane and will be paid separately. EA 496
10 Trimming of tree branches in the vicinity of 33/11/LT lines and remaoval of branches from site to suitable place EA 103
11 PROVD/OPERT Farana 7.5 Ton for 12Hr for loading & unloading of material.Farana will be used at Store/Site &same farana will be used at site for unloading. EA 50
12 Providing and laying Plain Cement Concrete (PCC) of proportion (1:1.5:3) in foudations and plin ths using approved quality of cement, 20mm size hard crusher broken granite stone metal and scr eened, washed sharp sand for mortar of approved quality and frosting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels in layers not exceeding 15cm thick in each layer including cost, conveyance, loading, unloadin g, royalties and taxes, cess, of all materials & cost of all laber machinaries required for the work etc., as directed by Engineer-in-Charge.%_1 M3 20
13 PCC(Lean Concrete) in the ratio 1:3:6(Grade M-10). Rates quoted shall be inclusive of necessary levelling%_1 M3 15
14 Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in Cement mortar 1:6 (1 Cement : 6 Coarse sand) as per specifcation. Scope includes supply of all material%_1 M3 20
15 15 mm Cement Plaster on the rough side of single or half brick wall of mix-1:6 (1 Cement : 6 Fi ne sand (50 % fine :50% coarse)) as per specification. Scope includes supply of all material.%_ 1 M2 15
16 BA will suppply the paint <(>&<)> will carry out Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand and manufacture. M2 500
17 Dismantling of 11/13 Mtr. Joist/WPB Pole- 150X150 mm/ 160X160 mm (Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 10km /site store and refilling the pit withng removal and disposal of malba at proper location as per instruction of EIC. Transportation w ith adequete vehicle load/capacity shall be only paid seperately%_1 EA 100
18 Dismantling of 9/11 PCC (Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 10km / site store and refilling the pit with loose earth and ramming inmalba at proper location as per instruction of EIC. Transportation with adequete vehicle load/ capacity shall be only paid seperately%_1 EA 100
Part A. Supply of Materials Required for Construction of 11kV line, Sub-Station, LT Line and Meter
Description UoM Qty Unit price GST Unit Price with GST Total Amount
1 WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.) EA 7604.0
2 9 Mtr. long 300 Kg. PSC Pole (For Raising of LT ABC) EA 20744.0
3 3Cx400mm2 11KV XLPE Cable (Armoured), A2XWY MTR 7600.0
4 Heat shrinkable jointing kit for 3Cx 400mm2 11 KV XLPE Cable(outdoor type) EA 16.0
5 Heat shrinkable jointing kit for 3Cx400 mm2 11 KV XLPE Cable(straight type) EA 36.0
6 Conductor Covered 11KV 100 Sqmm AAA MTR 680797.3
7 Dead end assembly with crosss arm accessories for Covered Conductor EA 4524.0
8 IPC for 100 sq.mm AAA conductor (For covered conductor) EA 4524.0
9 Non Metallic Ties 11KV (For covered conductor) EA 21198.0
10 Midspan Joint for 100 Sqmm AAAC XLPE Covered Conductor EA 648.0
11 Gi Pipe Earthing 40mm. 3 Mtr. Long EA 2409.0
12 4x50+1x50+1x16 Sqmm LT AB Cable MTR 134463.4
13 3x50+1x35+1x16 Sqmm LT AB Cable MTR 263947.8
14 1x35+1x25 Sqmm LT AB Cable MTR 338990.5
15 Pole clamp for EYE hook for (XLPE Aerial bunched Cable) PAA 28486.0
16 EYE hook for XLPE Aerial bunched Cable EA 13437.0
17 Dead End Clamp suitable for messenger XLPE Aerial bunched Cable EA 13437.0
18 Suspension Clamp with EYE hook for ABC (25-70 sq.mm) EA 15049.0
19 Insulated piercing connector Type-B-main 16 to 95 sq.mm & Tap-16 to 95 sq.mm EA 31058.0
20 Cable 1.1kV AI 3.5Cx35 Sqmm Un-Armoured MTR 32500.0
21 LT Distribution Box Polycarbonate (10Way) EA 8019.0
22 LT Stay set Complete SET 6450.0
23 LT stay Clamp ( 1.40Kg/pair) PAA 6450.0
24 LT Stay insulator EA 6450.0
25 7/12 SWG GI stay wire, Grade -2 KG 77400.0
26 100 KVA , 11/ 0.4 KV (AL) Transformer BIS Energy level II EA 13.0
27 63 KVA , 11/ 0.4 KV (AL) Transformer BIS Energy level II EA 117.0
28 25 KVA , 11/ 0.4 KV (AL) Transformer BIS Energy level II EA 139.0
29 LT Distribution Box with MCCB, Aluminium Busbar of single Bay with kit kat fuse for 100 KVA S/S EA 13.0
30 LT Distribution Box with MCCB, Aluminium Busbar of single Bay with kit kat fuse for 63 KVA S/S EA 117.0
31 LT Distribution Box with MCCB, Aluminium Busbar of single Bay with kit kat fuse for 25 KVA S/S EA 139.0
32 4 Cx 150 mm2 LT XLPE Cable(Armoured) - FOR 100 KVA Trf. MTR 650.0
33 4 Cx 95 mm2 LT XLPE Cable(Armoured) - FOR 63 KVA Trf. MTR 5850.0
34 4 Cx 50 mm2 LT XLPE Cable(Armoured) - FOR 25 KVA Trf. MTR 6950.0
35 PG Clamp for 100 sq.mm AAA conductor EA 1614.0
36 AB Switch(11KV,200A.3pole,50Hz) "Vertical Type" SET 269.0
37 DD Fuse with Barrel (11KV.200A.3Pole) SET 269.0
38 10 AMP Fuse Link EA 807.0
39 DTR Name plate EA 538.0
40 GI Nut , Bolt & Washer of different size KG 35597.9
41 50x6mm GI Flat for earthing, 2.36kg/mtr. KG 33355.5
42 25x6mm GI Flat for earthing, 1.25kg/mtr. KG 5817.1
43 No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing KG 7215.7
44 11kv Local language Danger Plate, 1 no's. EA 7604.0
45 Local language LT Danger Plate, 1 no's. EA 20475.0
46 Back Clamp for danger Plate 25X3 mm. flat KG 10575.1
47 Top Channel 100X50X6mm, 9.56 KG/Mtr. KG 75149.8
48 GI Bracing Angle 50x50x6mm., 4.5Kg./mtr. KG 40754.2
49 Belting Channel 75X40X 4.8mm., 7.14KG/Mtr. KG 65577.8
50 Lightning Arrester(12KV,10KA) Station Class EA 831.0
51 11 KV V cross Arm (10.2 K.g. each ) EA 6352.0
52 GI Back Clamp for V cross arm (11KV) ( 0.85 kg each) EA 6352.0
53 F bracket 100x50X6 mm GI channel (2kg each) EA 6352.0
54 11 KV pin insulator polymer EA 22005.0
55 Disc insulator (B&S) 70 KN polymer EA 5331.0
56 H W fitting (B&S)70KN(3bolted) EA 807.0
57 H.T. stay set complete SET 3156.0
58 HT stay Clamp (1.9Kg/pair) PAA 3156.0
59 H.T. Stay Insulator Type-C EA 3156.0
60 7/10 SWG Stay Wire 15kg /stay KG 47340.0
61 Earthing of Support ( Coil Type ) EA 28348.0
62 GI Barbed wire/Anticlimbing device (3Kg /Pole) KG 83430.0
63 Back Clamp for anticlimbing device 25X3 mm. flat KG 33795.9
64 Single Phase Meter 1P 10-60 Amp With Box EA 23682.0
65 Polycarbonate Green Colour Seal EA 71046.0
Part B. Erection, Testing & Commissioning of Construction of 11kV line, Sub-Station, LT Line and Meter
1 Erection, Testing & Commissioning for Construction of 11kV OH line with Covered Conductor, as per technical specification and scope of work. UoM Qty
1 Installation/Erection of 11 Mtr long, WPB-Pole including loading and unloading, transportation from site/tent upto 3 Km., excavation, refilling, flooding with water, ramming/compacting of foundation as per TPNODL specifications and drawing including removal & disposal of extra malba as per instruction of EIC. The scope of work include providing & laying of 1:1.5:3 , M20, concrete of size - 500(B)x500(W)X1800(H) , and cooping of 500(B)x500(W)x450(H), Scope of work also includes 5 days curing and zebra painting (In Black & Yellow Strips/Zebra) .As per drawing. As per TPNODL Specification. EA 7604.00
2 ITC of 9 MTR PSC Pole including loading and unloading, transportation from site/tent upto 3 Kms., excavation,Includes and civil work. The scope also includes providing of all civil material for concreting . Transportation, loading and unloading of Pole from Nearest division/store/site office to site(maximum upto 3KM), Excavation for grouting, including concreting as per standards and drawings.Concreting to be done with PCC-1:1.5:3. of size - 500x500x1500 Muffing and ,Padding 500x500x75mm. 500(B)x500(W)x300(H) Scope of work also includes 5 days curing and zebra painting (In Black & Yellow Strips/Zebra) as per drawing EA 20744.00
3 Supply & Laying of PIPE HDPE 200 MM DIA PN8 , PE 80 through HDD method .Scope of work also includes making Trenchless ducts with 200 mm Dia HDPE pipe casing using HDD machine including supply of HDPE pipe as per IS 4984, (Providing parabolic graph included in the scope) MTR 7300.00
4 Supply & Laying/Mounting and fixing of HDPE Pipe -200mm Dia ( PN-8,Grade PE-80)and sealing of the same for LT/HT Cables. Scope also includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe. (Excavation is excluded) MTR 200.00
5 Lay-1.1KV Cbl(16-630 sqmm)-Trench/Pipe As per TPNODL Specification. MTR 7600.00
6 BA will excavate the cable trench length by providing all necessary tool, Manpower, pump etc suitable for HT & LT Cable laying and Back fill the same earth soil BA will supply neccessry barricades at the excavation site. CUM 72.00
7 Earth Work-hard rock.Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and Engineer-in charge. Note- All kind of excavation work with different size for plinth, Structu re & other works will be considered under this line items Hard rock.%_1 CUM 30.00
8 Supplying and spreading, filling other works with fine sand under floors,ground etc as per EIC instruction. Scope of work also includes watering, ramming, consolidating and dressing complete and other works if required at site . CUM 12.00
9 Supply, laying & fixing of RCC type Precast slab any types of work( Cable Laying etc) including Caution tape, Sand as per approved drawing EA 200.00
10 Supply and Installation of cable Route marker including transportation from site/tent, excavation, refilling, disposing of malba, flooding with water, ramming/compacting of foundation as per specifications and drawing. EA 78.00
11 Demolishing stone rubble masonry manually/ RCC/BRICK WORK/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : In cement mortar. CUM 48.00
12 ITC of jointing kit of 11kV 3Cx 400 sq mm with Heat Shrink and providing jointing services as per Standards, GTP, Drawing and specifications. Approved Make- Raychem & 3M. (straight through) EA 36.00
13 ITC of jointing kit of 11kV 3Cx 400 sq mm with Heat Shrink and providing jointing services as per Standards, GTP, Drawing and specifications. Approved Make- Raychem & 3M. (Outdoor Termination) EA 16.00
14 Stringing of 11KV insulated Conductor size from 55sqmm to 100sqmm.etc.BA has to provide necessary Tools , manpower for stringing &Jumpering. MTR 680797.30
15 ITC of Dead end assembly with accessories for Covered Conductor EA 4524.00
16 ITC of 11 KV IPC, suitable for 100 sqmm covered conductor as per design EA 4524.00
17 ITC of Non Metallic Ties 11KV (For covered conductor) EA 21198.00
18 Fixing of Mid Span Compression Joints suitable for AAAC/ACSR Conductor. As per TPNODL Specification. EA 648.00
19 Installation of Earthing pipe with 40mm dia 3 Mtr long Class-B GI Pipe(Jindal/Tata/Sail/Rinl) without earth chamber. The Scope include to excavation & installation of incuding earthingpipe dia up to 100mm dia., Fixing of Nutbolt, 25 Kg Bentonide Power, connection & welding with incoming earth flat. Each pit resistance will be measured and recorded and shall be as per IS. the levelling & ramming of earth and removal of extra malba. The work to be executed as per TPNODL drawing & design EA 2409.00
20 ITC of LT AB Cable 4x50+1x50+1x16 Sqmm BA will provide necessary manpower, tools, machinery etc, ladder etc for stringing activities. As per TPNODL Specification. MTR 134463.41
21 ITC of LT AB Cable 3x50+1x35+1x16 Sqmm BA will provide necessary manpower, tools, machinery etc, ladder etc for stringing activities. As per TPNODL Specification. MTR 263947.80
22 ITC of LT AB Cable 1x35+1x25 Sqmm BA will provide necessary manpower, tools, machinery etc, ladder etc for stringing activities As per TPNODL Specification. MTR 338990.51
23 ITC of Pole Clamp for with all necessary nutbolt for fixing eye hook suitable different size of LT ABC Cable / Stay etc suitable for PSC pole. BA will provide necessary tool, manpower, nubolt as per TPNODL specification. EA 28486.00
24 ITC of Eye Hook for supporting of Dead end & Suspension LT ABC Cable. BA will provide necessary tool, manpower, nubolt as per TPNODL specification. EA 13437.00
25 ITC of Dead end clamp for stringing LT ABC Cable.BA will provide necessary tool, manpower, nubolt as per TPNODL specification. EA 13437.00
26 ITC of suspension clamp for stringing LT ABC Cable.BA will provide necessary tool, manpower, nubolt as per TPNODL specification. EA 15049.00
27 ITC of All type of Connector IPC, Connector. EA 31058.00
28 ITC of 1.1kV AlI 3.5Cx35 Sqmm Un-Armoured Cable, BA will provide necessary manpower, tools, machinery etc, ladder etc for stringing activities As per TPNODL Specification. MTR 32500.00
29 ITC of LTDB box in pole for releasing power supply to LT 1ph & 3ph consumer. Scope includes provide necessary GI clamp arrangement for fixing LTDB to pole.Termination of incoming & outgoing cable in LT Dist Box as per TPNODL Specification. EA 8019.00
30 ITC of Complete LT Stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts BA will do the excvation including excvation, supply of 0.5Cum cement concrete foundation 1:1.5:3 size ( 500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPNODL Drawing & Standard. EA 6450.00
31 ITC of 11/0.4kV, 100kVA 3-Phase Distribution Transformer on existing structure as per specification including loading, unloading,Testing of Transformer at Site. shifting/transportation from site /tent. Scope of work includes jumpering/connection at HT and LT side & Earthing Connections. EA 13.00
32 ITC of 11/0.4kV, 63kVA 3-Phase Distribution Transformer on existing structure as per specification including loading, unloading,Testing of Transformer at Site. shifting/transportation from site /tent upto15KM. Scope of work includes jumpering/connection at HT and LT side & Earthing Connections..BA will provide necessary control cable ferruling, control cable schedule, connectors, lugs & cable gland at both end of terminations of control cable. EA 117.00
33 ITC of 11/0.4kV, 25kVA 3-Phase Distribution Transformer on existing structure as per specification including loading, unloading, Testing of Transformer at Site.shifting/transportation from site /tent upto15KM. Scope of work includes jumpering/connection at HT and LT side & Earthing Connections..BA will provide necessary control cable ferruling, control cable schedule, connectors, lugs & cable gland at both end of terminations of control cable. EA 139.00
34 ITC of Outdoor Type LT Distribution Box with MCCB for 11/0.4kV,100kVA Three Phase Transformer on existing structure as per specification EA 13.00
35 ITC of Outdoor Type LT Distribution Box with MCCB for 11/0.4kV,63kVA Three Phase Transformer on existing structure as per specification EA 117.00
36 ITC of Outdoor Type LT Distribution Box with MCCB for 11/0.4kV,25kVA Three Phase Transformer on existing structure as per specification EA 139.00
37 ITC of LT XLPE Cable(Armoured) - form DTR to Distribution Box. BA will provide necessary manpower, tools, machinery etc, ladder etc for stringing activities. As per TPNODL Specification. MTR 13450.00
38 ITC of PG Clamp for 100 sq.mm AAA conductor EA 1614.00
39 ITC of at 11KV 3pole AB Switch 200Amp in existing structure providing necessary manpower, nutbolt,Terminal connection, earthing connection, site minor modification, alignment, welding, cutting of Ms channel & AB switch pipe etc as per site requirement ,as per EIC & drawing SET 269.00
40 ITC of DO Fuse with link wire set in existing structure providing necessary manpower, nutbolt,Terminal connection, earthing connection, site minor modification, welding,Ms channel etc SET 269.00
41 ITC of Installation of LT/HT Danger Board along with back clamp as per specification EA 28348.00
42 ITC of Barbed Wire with clamp (to avoid the climbing at pole) for 9Mtr/11Mtr/13 Meter pole/H Pole as per TPNODL specification and drawing. EA 28348.00
43 Fixing of complete 11KV line Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts BA will do the excvation including excvation, supply of 0.5Cum cement concrete foundation 1:1.5:3 size ( 500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPNODL Drawing & Standard. EA 3156.00
44 ITC of Different type of channel & angle, installation,welding & fabication work of different size GI Channel (100x50x6mm, 75x75x6mm, 50x50x6mm,75X40X4.6mm, etc) as per size requirement KG 181481.76
45 ITC of Different type of channel & angle, installation,welding & fabication work of different size Flat (25x6 & 50x6) as per size requirement KG 39172.66
46 Installation of different size of GI Nut ,bolt & washers, As per TPNODL Specification. KG 35597.90
47 Erection of earthing coil (8 SWG wire dia) along with 8 SWG Wire, Nut -bolt & other accessories to earth the pole as per TPNODL Design .Scope of work also includes the excavation of earth upto 1.2 Mtr depth for erection of earthing coil and disposal of extra malba up to 150Mtr as EIC instructions.As per TPNODL Specification. EA 28348.00
48 Installation of 11KV Polymer Insulator along with Nutbolts for 11KV line.Nutbolts will be paid separately EA 22005.00
49 ITC of Disc insulator (B&S) 70 KN polymer EA 5331.00
50 ITC of H W fitting (B&S)70KN(3bolted) EA 807.00
51 Installation of V cross arm/Top bracket with back clamp on pole along with Nut bolts for 11KV line. Nutbolts will be paid separately, As per TPNODL Specification. EA 6352.00
52 ITC of the Lighting arrester (single phase) in existing structure providing necessary manpower, nutbolt,Terminal connection, earthing connection, site minor modification, welding,Ms channel etc As per TPNODL Specification. EA 831.00
53 SITC including loading , unloading & transportation of TIE PLASTIC BLACK SIZE 7.6 MM X 150MM as per specification. EA 11061.00
54 SITC including loading , unloading & transportation of LT AB Cable End Cap as per specification EA 7374.00
55 ITC of All types of GI Wire for LV Line MTR 7215.74
56 SITC of installation including loading , unloading & transportation of HDPE Pipe - 40 mm dia for Wire/Cable protection. Scope also include supply and erection of all required accessories for fixing it with pole/structure such as GI clamp (12X3 mm) at every interval of 1.5 mtr ,Nut & Bolt ,sealing of the pipe ,collar fixing as per specification. MTR 4035.00
57 SITC of Laying/Mounting and fixing of HDPE Pipe -110mm dia ( PN-4,Grade PE-80)and sealing of the same for LT/HT Cables. Scope aIso includes providing and laying all required consumable etc. for collar fixing and sealing of Pipe. (Excavation is excluded) MTR 4035.00
58 SITC of Wooden Cleat set, MS strip and hard ware for fixing cable including painting one coat of red oxide & two coats of black paint for Distribution Transformer. Scope also includes supply of ISI marked paint. (Price per set ) Set 269.00
59 SITC including loading, unloading & transportation of Plaster of Paris (PoP) Kg 672.50
60 SITC of AL Lugs with Double Compresion Gland suitable for 50- 150 sq mm cable/conductor, Crimping with cable and Fixing/connecting as per Specification .Scope also include supply and erection of PVC Tape as per voltage requirement.The crimping shall be done with haudralic crimping machine. EA 4035.00
61 BA will supply & Install Jointing KIT Heat Shrinkable , Approved Make for Jointing Kit- Raychem or 3M for 1.1KV XLPE Cable 50Sqmm-120 SQMM XLPE 4 core cable .No extra rate will be paid for Jointing services. Strainght through joints EA 256.00
62 BA will supply & Install Jointing KIT Heat Shrinkable , Approved Make for Jointing Kit-Raychem or 3M for 1.1KV XLPE Cable 120Sqmm-240 SQMM XLPE 4 core cable.No extra rate will be paid for Jointing services.Strainght through joints EA 13.00
63 Supplying and spreading, filling other works with fine sand under floors,ground etc as per EIC instruction. Scope of work also includes watering, ramming, consolidating and dressing complete and other works if required at site . CUM 269.00
64 Supplying, Laying, spreading and compacting with hand roller stone aggregate of specified sizes: 63 mm to 45 mm size stone aggregate to WBM specifications in uniform thickness, hand picking to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . .Scope of work also includes of jungle such as grass,small tree,plant etc. CUM 403.50
65 SITC of Boundary Fencing with Gate as per specifications. Civil works including site clearing and vegetation removal, earthwork excavation, sand filling, stone soling, PCC works, brick masonry, internal plastering, painting works, fabrication and erection of structural steel, installation of MS gates, and GI barbed wire fencing complete in all respects as per approved specifications and drawings. RM 4842.00
66 ITC of Single Phase Meter with Box (10-60) -1 No & Meter Seal-3 Nos. SET 23682.00
67 SITC Each Service connection kit with following items i)Service cable(4 sq. mm twin core PVC Al. Wire - up to 25 Mtr ) ii) 10 SWG G.I. supporting Wire (75 gm/Mtr) (Insulated)-up to 25 Mtr. iii)PorceilineSpool - 02 nos., Link Clip - 10 nos. iv) GI Bend Pipe (bracket) 20 mm dia.(NB) 2.8 Mtr.long - 1 no. SET 23682.00
68 SITC House Wiring Materials for each HH i) Miniature Circuit Breaker 16A-2 nos, ii) 4 x4"Wooden/PVC Board -1no, iii)8"x 6"Wooden/PVC Board along with 2 no. 5Amp Switch & 1 no. 5Amp Socket, iv) 6"x4" Wooden/PVC Board-1 no, SET 23682.00
69 SITC Earthing(Coil Earthing-1no & Insulated G.I. Wire-400gm/earthing) for earting of 1 PH meter No 23682.00
70 SITC LED Lamp 9Watt- 1 Nos. No 23682.00
Part C. For additional work as per requirment
1 Detail Survey of HT/LT lines profile plotting, pole spotting and preparation of pole schedule and GIS Mapping, indexing/numbering of Poles as per GIS format, scope also include site survey for GIS indexing as per requirement. Km 880.00
2 Loading, transportation and Unloading of JOIST /WPB/ RLP & other type of poles of 10-11 Mtr long from store/site to other site or vice versa (above 3 km upto 10 km) - price per Pole.Note:- This line items applicable when full trailer pole shifting not required. EA 496
3 Transportation of various items from TPNODL store/site to other site or vice versa in TPNODL operational area - Trailer with labours as required (price per trip). Scope of work also include loading and unloading of materials heavy items like, 14 mt Rail Pole, PCC Pole, HT Panel, Transformer, Cable Drum, LT Board. Item whose loading& unloading is to be done with crane, charges for crane will be paid separately.(Full Trailer) upto 70 Km. EA 992
4 Transportation of various items from store/site to other site or vice versa in operational area - Trailer per KM beyond 70KM with labours as required (price per trip). Scope of work also include loading and unloading of materials heavy items like, 14 mt Rail Pole, PCC Pole, HT Panel, Transformer, Cable Drum, LT Board . Item whose loading& unloading is to be done with crane , charges for crane will be paid separately. (Full Trailer) KM 496
5 Transportation of various items from TPNODL store/site to other site or vice versa in TPNODL operational area - Tractor with labours as required (price per trip). Scope of work also include loading and unloading of materials heavy items like, Rail Pole, PCC Pole, HT Panel, Transformer, Cable Drum, LT Board. Item whose loading& unloading is to be done with crane, charges for crane will be paid separately.upto 40.0 Km EA 1488
6 Transportation of various items from store/site to other site or vice versa in operational area - Tractor per KM beyond 40 KM with labours as required (price per trip). Scope of work also include loading and unloading of materials heavy items like, Rail Pole, PCC Pole, HT Panel, Transformer, Cable Drum, LT Board . Item whose loading& unloading is to be done with crane , charges for crane will be paid separately. KM 496
7 Transportation of various items from TPNODL store/site to other site or vice versa in TPNODL operational area - Full body Truck with labours as required (price per trip). Scope of work also include loading and unloading of materials except heavy items like HT Panel, Transformer, Cable Drum, LT Board where loading, unloading is to be done with crane and will be paid separately (Full Truck), upto 70.0 Km EA 1488
8 Transportation of various items from store/site to other site or vice versa in operational area - Full Body Truck per KM beyond 70 KM with labours as required (price per trip). Scope of work also include loading and unloading of materials heavy items like, Rail Pole, PCC Pole, HT Panel, Transformer, Cable Drum, LT Board . Item whose loading& unloading is to be done with crane , charges for crane will be paid separately. KM 496
9 Transportation of various items from TPNODL store/site to other site or vice versa in TPNODL operational area - Tempo 407 with labours as required (price per trip). Scope of work also include loading and unloading of materials except heavy items like HT Panel, Transformer, Cable Drum, LT Board where loading, unloading is to be done with crane and will be paid separately. EA 496
10 Trimming of tree branches in the vicinity of 33/11/LT lines and remaoval of branches from site to suitable place EA 103
11 PROVD/OPERT Farana 7.5 Ton for 12Hr for loading & unloading of material.Farana will be used at Store/Site &same farana will be used at site for unloading. EA 50
12 Providing and laying Plain Cement Concrete (PCC) of proportion (1:1.5:3) in foudations and plin ths using approved quality of cement, 20mm size hard crusher broken granite stone metal and scr eened, washed sharp sand for mortar of approved quality and frosting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels in layers not exceeding 15cm thick in each layer including cost, conveyance, loading, unloadin g, royalties and taxes, cess, of all materials & cost of all laber machinaries required for the work etc., as directed by Engineer-in-Charge.%_1 M3 20
13 PCC(Lean Concrete) in the ratio 1:3:6(Grade M-10). Rates quoted shall be inclusive of necessary levelling%_1 M3 15
14 Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in Cement mortar 1:6 (1 Cement : 6 Coarse sand) as per specifcation. Scope includes supply of all material%_1 M3 20
15 15 mm Cement Plaster on the rough side of single or half brick wall of mix-1:6 (1 Cement : 6 Fi ne sand (50 % fine :50% coarse)) as per specification. Scope includes supply of all material.%_ 1 M2 15
16 BA will suppply the paint <(>&<)> will carry out Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand and manufacture. M2 500
17 Dismantling of 11/13 Mtr. Joist/WPB Pole- 150X150 mm/ 160X160 mm (Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 10km /site store and refilling the pit withng removal and disposal of malba at proper location as per instruction of EIC. Transportation w ith adequete vehicle load/capacity shall be only paid seperately%_1 EA 100
18 Dismantling of 9/11 PCC (Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 10km / site store and refilling the pit with loose earth and ramming inmalba at proper location as per instruction of EIC. Transportation with adequete vehicle load/ capacity shall be only paid seperately%_1 EA 100
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
listing-row.html
html • 0.00 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_1Ph Smart meter 5 - 30 Amp_compressed.pdf
pdf • 15.97 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_2. ENG-GEN-4000 (A) Specification For Polycarbonate Meter Seal.pdf
pdf • 0.39 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_2a. Tech Spec ENG-LV-3024-LTDB 25,63,100 KVA Rev-1.pdf
pdf • 1.21 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_ENG - GEN - 011 Covered conductor accessories.pdf
pdf • 0.61 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_ENG - GEN - 218 Drop down fuse along with mounting arrangment & fuse link.pdf
pdf • 0.58 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_ENG -HV-2027 11KV 5KN PIN INSULATOR.pdf
pdf • 0.29 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_ENG-GEN-012 GI Barbed Wire along with back clamp.pdf
pdf • 0.36 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_ENG-GEN-052-R1_Vertical 11kV AB Switch 400A & 200A.pdf
pdf • 1.36 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_ENG-GEN-168 Danger board clamp.pdf
pdf • 0.98 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_ENG-GEN-193 11KV & 33KV F clamp.pdf
pdf • 0.37 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_ENG-GEN-4027.pdf
pdf • 1.03 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_ENG-GEN-4028.pdf
pdf • 0.85 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_ENG-GEN-4038 Specification for GI wires of various sizes.pdf
pdf • 0.58 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_ENG-GEN-4039 Specification for GT stay wires.pdf
pdf • 0.58 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_ENG-HV-2024 Technical Specification For HT Stay set including Clamp.pdf
pdf • 1.31 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_ENG-HV-2026 Technical Specification For V cross Arm 11 KV.pdf
pdf • 1.19 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_ENG-LV-013 1Ph LT(1.1KV) AB cable.pdf
pdf • 0.42 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_ENG-LV-020 3Ph LT(1.1KV) AB cable.pdf
pdf • 0.44 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_ENG-LV-3029.pdf
pdf • 0.45 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_ENG-LV-74 AB cable accessories.pdf
pdf • 0.68 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_PM_JUGA+AAGY_BGJY_Solar_New Coonection-Keonjhar_TPNODL_R3.xlsx
xlsx • 0.03 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_TPU-D-ENG-HV-20050 11KV Termination Kit.pdf
pdf • 0.56 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_TPU-D-ENG-HV-20062 11KV XLPE UG cable.pdf
pdf • 0.87 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_TPU-D-ENG-HV-20068 11 KV Covered Conductor.pdf
pdf • 0.65 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_TPU-D-ENG-HV-20068.pdf
pdf • 0.65 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_TPU-D-ENG-HV-20069 Technical Specification for Distribution Transformer rated 25KVA to 100KVA (11KV-0.433KV)(Al Win.pdf
pdf • 1.66 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_TPU-D-ENG-LV-30001 LT POWER CABLE.pdf
pdf • 0.46 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_TPU-D-ENG-LV-30002 LT Control cable & lower size PVC power cable.pdf
pdf • 0.39 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_TPU-D-ENG-LV-30002 LT Control Cable.pdf
pdf • 0.39 MB
22a25a4a153e49cda9c82ead2f0d73ce_2. Technical Specifications_TPU-D-ENG-LV-30003 LT AB Cable.pdf
pdf • 0.41 MB
22a25a4a153e49cda9c82ead2f0d73ce_3. Drawings_11MTR WPB POLE DRAWINGS_11 Mtr Pole 90° Cut point GA Drawing.pdf
pdf • 2.00 MB
22a25a4a153e49cda9c82ead2f0d73ce_3. Drawings_11MTR WPB POLE DRAWINGS_11KV LINE DP ON 11MTR WPB-Model (2).pdf
pdf • 0.49 MB
22a25a4a153e49cda9c82ead2f0d73ce_3. Drawings_11MTR WPB POLE DRAWINGS_11KV LINE ON11MTR WPB SP WITH 180' CUT POINT-Model.pdf
pdf • 0.56 MB
22a25a4a153e49cda9c82ead2f0d73ce_3. Drawings_11MTR WPB POLE DRAWINGS_11MTR POLE MOUNTED DTR WITH VERTICAL AB & DO FUSE-Model.pdf
pdf • 0.37 MB
22a25a4a153e49cda9c82ead2f0d73ce_3. Drawings_11MTR WPB POLE DRAWINGS_11MTR SP WPB WITH V-CROSS ARM-Model.pdf
pdf • 0.63 MB
22a25a4a153e49cda9c82ead2f0d73ce_3. Drawings_11MTR WPB POLE DRAWINGS_8-11MTR WPB pole Foundation.pdf
pdf • 0.17 MB
22a25a4a153e49cda9c82ead2f0d73ce_3. Drawings_9MTR PSC POLE DRAWINGS_1-Concreate type psc pole with Couping foundation.pdf
pdf • 0.13 MB
22a25a4a153e49cda9c82ead2f0d73ce_3. Drawings_9MTR PSC POLE DRAWINGS_5-LT cable string psc pole-Model.pdf
pdf • 0.34 MB
22a25a4a153e49cda9c82ead2f0d73ce_3. Drawings_9MTR PSC POLE DRAWINGS_Composite Ckt for 11kv & LT ABC-Model.pdf
pdf • 0.21 MB
22a25a4a153e49cda9c82ead2f0d73ce_3. Drawings_Boundary Wall Fencing1-Model.pdf
pdf • 0.53 MB
22a25a4a153e49cda9c82ead2f0d73ce_3. Drawings_Covered Conductor Accessories Fitting-Model.pdf
pdf • 0.55 MB
22a25a4a153e49cda9c82ead2f0d73ce_3. Drawings_DTR EARTHING REVISED Drawing1-Model.pdf
pdf • 0.33 MB
22a25a4a153e49cda9c82ead2f0d73ce_3. Drawings_HDD_33 11 KV CABLE TRENCH HDD METHOD-Model.pdf
pdf • 0.33 MB
22a25a4a153e49cda9c82ead2f0d73ce_3. Drawings_OPEN TRENCH DRAWING_IDENTIFICATION OF TAG IN POWER CABLE-Model.pdf
pdf • 0.20 MB
22a25a4a153e49cda9c82ead2f0d73ce_3. Drawings_OPEN TRENCH DRAWING_PRECAST CABLE COVER FOR 11-33KV CABLE TRENCH OPEN METHOD-Model.pdf
pdf • 0.29 MB
22a25a4a153e49cda9c82ead2f0d73ce_3. Drawings_OPEN TRENCH DRAWING_Revised 33KV UG CABLE LAYING FOR OPEN TRENCH METHOD-Model.pdf
pdf • 0.45 MB
22a25a4a153e49cda9c82ead2f0d73ce_3. Drawings_OPEN TRENCH DRAWING_ROUTE MARKER CUM JOINT MARKER FOR HT XLPE UG CABLE (11-33KV )-Model.pdf
pdf • 0.35 MB
22a25a4a153e49cda9c82ead2f0d73ce_3. Drawings_OPEN TRENCH DRAWING_WARNING TAPE FOR 33-11KV CABLE LAYING-Model.pdf
pdf • 0.19 MB
22a25a4a153e49cda9c82ead2f0d73ce_3. Drawings_ROUTE MARKER CUM JOINT MARKER FOR HT XLPE UG CABLE (11-33KV )-Model.pdf
pdf • 0.35 MB
22a25a4a153e49cda9c82ead2f0d73ce_3. Drawings_TPNODL-SID-GEN-0012 Service connection and HH wiring under BGJY.jpg
jpg • 0.45 MB
22a25a4a153e49cda9c82ead2f0d73ce_1. Tender Documents_2500001311_PM JUGA with GCC.pdf
pdf • 5.90 MB
22a25a4a153e49cda9c82ead2f0d73ce_4. Annexure-1(Price Bid).xlsx
xlsx • 0.03 MB
22a25a4a153e49cda9c82ead2f0d73ce_5. Annexure- X - Tata Code of Conduct.pdf
pdf • 0.60 MB
22a25a4a153e49cda9c82ead2f0d73ce_6. Helath and Safety Policy.pdf
pdf • 0.40 MB
22a25a4a153e49cda9c82ead2f0d73ce_7. Approved Vendor List.pdf
pdf • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .