GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
ALLIED SERVICES TO VARIOUS MISC EXTERNAL FACILITIES, HOIST EQUIPMENTS, DG SETS AT RESTRICTED AREA UNDER RCMA, ATC, PAPU AND NEWLY TAKEN OVER ASSETS FROM CCE AT KANCHAANBAGH
2024_MES_636953_1
8705/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Kaancnhanbagh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹94,000
Yes
13 Mar 2024
11 Jan 2024
2 Feb 2024
11 Jan 2024
31 Jan 2024
25 Jan 2024
11 Jan 2024 - 18 Jan 2024
Amount
Supply only Power Contactor 32 to 40 Amps type with 110 Volt coil voltage, three phase.
Supply only Power Contactor 40 to 70 Amps type with 110 Volt coil voltage, three phase.
Supply only spare kit for 32 to 40 Amps contactor
Supply only spare kit for 60 to 70 Amps contactor
Supply only push button of any type, Make : L&T/GE.
Supply only Flexible geared coupling of any type/size
Supply only Bimetal over load relays for contactors Make for srl item No. 1 to 7 : BCH/L&T/C&S/Telemech.
Supply only push button assembly pendent type complete with all accessories including support hanging wire up to 10 mtrs suitable for 5 Ton to 10 Ton, Make : L&T/GE/Cranex.
Supply only of 1.5 sqmm 12 core Copper conductor cable PVC insulated & PVC sheathed flexible multistranded 1100 volts grade with in suitable with PVC conduit with clamps to fix on wall/railing complete as per site requirement
Supply only 2.5 Sqmm, 10 core Copper conductor cable PVC insulated & PVC sheathed flexible multistranded 1100 volts grade with PVC conduit with clamps to fix on wall/railing complete as per site requirement
Supply only 6 Sqmm, 8 core copper conductor cable PVC insulated & PVC sheathed flexible multistranded 1100 volts grade with PVC conduit with clamps to fix on wall/railing complete as per site requirement
Supply only 10 Sqmm, 6 core Copper conductor cable PVC insulated & PVC sheathed flexible multistranded 1100 volts grade with PVC conduit with clamps to fix on wall/railing complete as per site requirement Make:- Plaza/Polycab/Finecab/Finolex/Havells.
Supply only thruster break oil for hydraulic thruster break for long/cross travel/Hoist, Make : Servo/IOC/Bharat.
Supply only steel wire rope flexible type 6 sqmm for pendent push button box with necessary clamps/clips etc complete all specified and as directed.
Supply only electro magnetic break with break drum for break disk or break coil of any size/type . Make:- BCH/Speed-O-Control or equivalent
Supply only Main Hoist steel wire rope (as per existing size) suitable to 10 Ton EOT crane of adequate length and size including accessories.
Supply only Main Hoist steel wire rope (as per existing size) suitable to 5 Ton EOT crane of adequate length and size including accessories.
Material and labour for taking the gear box mechanism with necessary equipments carefully without any damage to exising structurer and taking out to authorized workshop/OEM service center if necessary and repair/replacement of gear oil, oil seal, pinion, reduction pinion, main gear, secondary reduction gear, shaft, bearing, coupling and other spares as required for proper functioning and refixing the same in its original position making all connections testing all parameters like CT & LT suitable for cranes up to 10 Ton and complete all as specified and directed. Note : Transportation to and from the site to work shopand the cost for the same is deemed to be included in quoted rate.
All as per item No. 18 here-in-before but for 15 to 20 Ton capacity Lifting Equipments
Material and labour for taking down wheel set carefully using hydraulic jack without any damage and taking out to the authorized workshop/OEM service center if necessary or repair/replacement of Bearing, pinion, wheel teeth to be make for grip and other spares as required for proper functioning and apply greasing wherever required parts assembling the complete wheel set with connected item suitable for 3 ton to 10 Lifting Equipments and complete all as directed.
All as per item No. 20 here-in-before but for 15 to 20 Ton capacity Lifting Equipments
Supply and fix in repairs VVVF drive of Lifting Equipments up to 5 ton capacity should be suitable for the existing crane including removing the unserviceable VFD drive complete all as directed.
All as per item No. 22 here-in-before but for 5 to 10 Ton capacity Lifting Equipments
Supply and fix in repairs VVVF drive control card of crane up to 10 ton capacity drive control card should be suitable for the existing crane including removing the unserviceable VFD drive control card complete all as directed.
All as per item No.24 here-in-before but for more than to 10 Ton up to to 25 Ton capacity Lifting Equipments
Renewal of burnt out control wiring for 5 to 25 Ton Lift with suitable size of copper cable and replacement of connectors, lugs, fuses etc and testing complete all as directed.
Removing the existing burnt out flame proof main switch and supply and fix flame proof main switch 32 Amps, TP&N, 415 volts with necessary connections complete all as directed.
Rewinding of Thruster motor of Lifting Equipments 10 to 25 Ton capacity with super enameled copper conductor of same existing gauge complete all as directed.
Supply & fix HRC fuse 16A with fuse carrier complete including removing the unserviceable HRC fuse complete all as directed. Make : GE/L&T/BCH.
Supply & fix HRC fuse 63A with fuse carrier complete including removing the unserviceable HRC fuse complete all as directed Make : GE/L&T/BCH.
Periodical maintenance by the EOM every month to various Fire Alarm systems including checking, testing, cleaning of Smoke Detectors, Heat Detectors, manual call points, Hooters, Sirens etc.. by carrying out preventive Maintenance and corrective Maintenance for trouble free and efficient functioning of entire system, replacement of the accessories connected to the Fire Alarm systems for the buildings at Main building , New admin & ETC The work is to be carried out all as directed. Note : Spares if any required shall be measured and paid under the relevant items of schedule. and labour element is deemed to be included in rate quoted.
Supply, installation, testing including removing the unserviceable old following spares required for the efficient functioning of the Conventional Fire Alarm systems :-
Photo electric (optical) Smoke detector with isolator base. Make : Godrej-VDS/Apollo/System Sensor
Heat detector with isolator base. Make : Godrej-VDS/Apollo/System Sensor
Ionization Smoke detector with base. Make : Godrej-VDS/Apollo/System Sensor
Electronic Hooter Make : GST/Agni/System Sensor
Manual call point . Make : Godrej-VDS/Agni/System Sensor/Securico
Response indicator Make : Godrej-VDS/Agni/Securico
Hooter . Make : Godrej-VDS/Agni/Securico
Maintenance free Battery 12V, 7AH Make : Exide/Amco
Manual call point switches. Make : Agni/Honeywell.
Manual call point glass. Make : Agni/GST.
24 volts potential free relay. Make : L&T/Siemens/Omran
Siren controller contactor . Make : L&T / SIEMENS / GE
Assorted Fuses. Make : GE/FTC.
Supply, installation, testing, complete including removing the old unserviceable following spares required for the efficient functioning of the Analogue Addressable Fire Alarm systems :-
Photo electric (optical) Smoke detector with isolator base. Make :Godrej-VDS/ Apollo/Morley IAS/GST
Ionization Smoke detector with base Make : Godrej-VDS/Apollo/Morley IAS/GST
Heat detector. Make : Godrej-VDS/Apollo/Morley/GST
Electronic Hooter Make : Apollo/Morley IAS/GST
Manual call point Make : Apollo/Morley IAS/GST
Fault Isolators Make : Apollo/Morley IAS/GST
Loop driver card Make : Apollo/Morley IAS/GST
Data/Ribbon cable with connector. Make : Apollo/GST.
M&L for 1.5 sqmm, 2 core copper conductor multistranded PVC insulated, sheathed FRLS cable conforming to IS specification with and including PVC conduit of suitable size suitable for Fire Alarm system complete including removing the unserviceable cable complete all as directed. Make : Godrej-VDS/FINOLEX/ORBIT/NEOLEX
M&L for 2.5 sqmm , 2 core copper conductor multistranded PVC insulated, sheathed FRLS cable conforming to IS specification suitable with and including PVC conduit of suitable for Fire Alarm system complete including removing the unserviceable cable complete all as directed. Make : Godrej-VDS/FINOLEX/ORBIT/NEOLEX
M&L for PVC conduit 15mm dia medium grade FRLS type suitable for Fire Alarm/street light poles from Looping box to GI bracket system including clamps and removing the unserviceable PVC conduit complete all as directed. Make : Godrej-VDS/FINOLEX/ORBIT/NEOLEX
S&F addressable 1/2 loop microprocessor based master fire alarm panel with its own battery charger, battery for 24 hours backup including testing and removing the unserviceable fire alarm panel, complete all as directed. Make : Boss/Honeywell/Agni.
M&L for Power supply and Battery charging board for 4 zone micro processor based Fire Alarm panel including removing the unserviceable battery charging board complete all as directed. Make : Ravel/GST/Agni
M&L for power supply and Battery charging board for 8 zone micro processor based Fire Alarm system including removing the unserviceable battery charging board complete all as directed. Make : Ravel/GST/Agni
M&L for display and control mother board for 4 zone micro processor based Fire Alarm system complete including removing the unserviceable display and control board complete all as directed. Make : Ravel/GST/Agni
M&L for display and control mother board for 8 zone micro processor based Fire Alarm panel complete including removing the unserviceable display and control board complete all as directed. Make : P100/GST/Agni
Suppy and fixing in repair 4 zone Fire Alarm panel complete including removing the unserviceable panel complete all as directed. Make : Ravel/GST/Agni
Suppy and fixing in repair 8 zone Fire Alarm panel complete including removing the unserviceable panel complete all as directed. Make : Ravel/GST/Agni
Disconnecting and removing of unserviceable levelling/stopping/slowing sensors and Supply and Fix of new levelling/stopping/slowing sensor complete all as directed.
Disconnecting and removing of unserviceable Mechanical switches stopping/slowing and Supply and Fix new Mechanical switches stopping/slowing complete all as directed.
Disconnecting and removing of unserviceable Break coil and Supply and Fix of new Break coil complete all as directed.
Maintenance of DG set and carrying out ‘B’ check and replacement of ‘B’ check kit filters such as Oil filter, by pass filter, fuel filter, CR element and CR plates complete with ‘O’ rings and draining of Engine oil and topping up with the new engine oil complete testing all as specified and directed by the Engr-in-Charge for the following capacity DG sets:- Note :- 1. Engine oil shall be measured and paid separately. 2. B Cheak to be carried out every after 250 hrs run or 6 months whichever is earlier. Make: KIRLOSKER/ CUMINS /GREAVES
20 KVA DG Set
40 KVA DG Set
125 KVA DG Set
250 KVA DG Set
320 KVA DG Set
400 KVA DG Set
500 KVA DG Set
625 KVA DG Set
62.5 KVA DG set (RCMA)
Renewal of unserviceable batteries with maintenance free batteries of 180 AH, 12V including connecting to DG set complete all as directed. Make:- EXIDE/ AMARON
Attending the breakdown of any capacity/make DG Sets, AMF Panels, by Technician & helper for checking all components and identifying and rectifying the faults and give report to concerned JE complete all as directed. Note :- Spare Parts for rectifying the fault shall be measured and paid seperately.
S&F in repairs automatic voltage regulator (AVR) up to 62.5KVA DG set and testing complete all as directed. Make:- As per OEM make.
S&F in repairs automatic voltage regulator (AVR) 125 to 250 KVA DG set and testing complete all as directed. Make:- As per OEM make.
S&F in repairs automatic voltage regulator (AVR) 320KVA to 630 KVA DG set and testing complete all as directed. Make:- As per OEM make.
Dismantling of exhaust pipe of the DG set by unscrewing nuts and bolts and taking down the pipe with muffler, removing the burnt out asbestos rope and well wrapping with new aluminium metal cladding with glass wool including cleaning the silencer, and fixing the same in its original position complete all as directed for the following capacity DG Sets.
125KV to 250 KVA DG set.
320 KV to 630 KVA DG set.
Disconnecting all electrical connections from the unserviceable self starter of any make/ capacity model 24 volts, 180 /200 AH and taking down the self starter and transporting to civil workshop for carrying out repairs, complete overhauling the system including replacing the unserviceable parts such as bearing, carbon brushes, clutch plates etc refixing the self starter in its original position, testing and commissioning complete all as directed. Note:- Supply only Armature coil, field coil shall be measured and paid separately under relevant items of this Schedule fixing included in this item.
Supply only Armature coil for self starter of any make of any capacity and of any model 24 Volts, 180/200 AH complete all as directed.
Supply only of field coil for self starter of any make, any capacity and any model 24 Volts, 180 /200AH complete all as directed .
Disconnecting all electrical connections from the unserviceable self starter of any make/capacity/model 12 volts, 180, 200 AH and taking down the self starter and transporting to civil workshop for carrying out repairs, complete overhauling the system including replacing the unserviceable parts bearing, carbon brushes, clutch plates etc refixing the self starter in its original position, testing and commissioning complete all as directed. Note:- Supply of Armature coil, field coil shall be measured & paid separately under relevant items of this Schedule.
Supply only Armature coil for self starter of any make, any capacity and any model 12 Volts, 180/200 AH complete all as directed.
Supply only of field coil for self starter of any make, any capacity and any model 12 Volts, 180/200 AH complete all as directed.
Disconnecting the oil cooler of 110 KVA to 250 KVA DG set of any make/ model from the existing locations duly removing of all mechanical connections and taking down the same for complete servicing opening the parts and cleaning thoroughly by using suitable cleaning material and acid and reassembling and refixing in its original position, testing and commissioning complete all as directed.
S&F in repairs air cleaning element inner and outer with necessary ‘O’ rings for the DG sets of following capacities as that of existing make and model complete all as directed.
Upto 40KVA DG Set
125 KVA to 250 KVA DG Set
320 KVA to 630 KVA DG Set
Disconnecting all the incoming and outgoing rubber hoses and draining out the water from the choked radiator assembly of the existing make and model and of various capacities of DG sets and taking down the radiator assembly by unscrewing all mechanical connections from the existing mounting, transporting the same to civil workshop for carrying out servicing, opening the top and bottom covers of radiator assembly cleaning thoroughly the chocked pipe of the radiator by using detergent, lime caustic soda, cotton etc., cleaning of all the deposited sediments in the pipes/tubes including arresting of leakage by means of soldering, brazing and transporting back to site and refixing the same in its original position with suitable size nuts, bolts and washers etc., complete all as directed for the following DG sets:-
Upto 62.5 KVA DG Set
125 KVA to 250 KVA DG Set
320 KVA to 630 KVA DG Set
Renewal of battery cable leads of copper conductor with brass lugs terminal, for the 12V 180 /200 AH batteries for self starter as that of existing size and length complete all as directed.
S&F in repairs automatic cut off Battery Charger suitable for 110V, up to 40 Amp Battery complete all as directed . Make SMPS/ Phonix
S&F in repairs automatic cut off Battery Charger suitable for 12/24 V, up to 40 Amp Battery complete all as directed. Make SMPS/ Phonix
Renewal of 'V' belts for the following capacity DG sets as per existing size and model complete all as directed. Make :- FENNER/ DUNLOP
Upto 62.5 KVA DG Set
125 KVA to 250 KVA DG Set
320 KVA to 630 KVA DG Set
Renewal of existing unserviceable water temperature gauge for the DG set of any description complete all as directed.
Renewal of existing unserviceable lubricant oil temperature gauge for the DG set of any capacity complete all as directed.
Renewal of existing unserviceable oil pressure gauge for the DG SET of any capacity complete all as directed .
Renewal of unserviceable Solenoid switch for DG set of any make and any capacity complete all as directed. Make :- RUSTON/ GREAVES COTTON/Kirloskar/CUMMINS.
Supply and filling the new engine oil 15W/40 for toping up, up to the required level complete all as directed. Make :- CASTROL/ INDIAN OIL/ SERVO
Drain out the fuel from the fuel tank of DG set of capacity 600 Ltrs and above and keeping it in separate container safely, disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank for cleaning, internally and externally by removing all the accumulated dirt/ sediment, leak testing the tank and welding/ brazing including one coat of synthetic enamel paint, refixing the tank in its original position, replacing the drain plug and PVC pipe, calibrating the fuel tank, refilling the drained out fuel back into the tank and marking of liters in gauge and provision of locking arrangements complete all as directed.
Removing of defective engine oil control pressure switch and supply & fix new engine oil control pressure switch suitable for up to 250 KVA set complete all as directed. Make Kirloskar- Cummins
Renewal of defective wiring with copper wire of existing size including replacement of electrical/ electronic parts of AMF panel & DG Set, complete all as directed. Note: - Supply only Electrical/ Electronic spare parts shall be measured and paid separately. Supply only of following spare parts :
Auxiliary contactor 240 Volts, (2NO.+2NC).
ON and OFF delay timer 240 V AC and 24 V DC.
Over load relay.
ML - 4 contactor.
Earth Fault Relay IRII-31-E1-WD Suitable for 250 V, AC. Make: C&S
Single phase preventer
Auxiliary Relays 24Volts / 6A
PLC based AMF relay unit
Low lube oil safety switch
Booster Relay 24Volts / 10A
Battery charger 24 V /10A panel mounting type
Coolant temperature sensor
LED indicating Lamp
Push buttons
Removing the defective charging dynamo of capacity 24 Volt DC any make, model, any capacity and opening it, by removing all nuts and bolts, cleaning with necessary cleaning agent and overhauling lubricating of the same replacing of armature, field coils reconnecting the same, refixing back, in original position testing and commissioning complete all as directed.
Supply & topping up of Inhibitor corrosion (coolant additive concentrate) as required (TVS Make) complete all as directed.
Supply and topping up of distilled water suitable for lead acid batteries of 12 volts complete all as directed.
Dismantling/taking out old unserviceable alternator (charging of battery) and taking out worn out spares such as ammeter, brush and field winding and repair the same by replacing ammeter, brush and rewinding of field coil with same gauge of copper wire and testing complete all as directed .
Calibration of PT pump and replacement of PT Pump kit, gear gasket, etc whichever is required for smooth functioning of DG Set complete all as directed.
Calibration of injectors by replacing injector cup, barrel plunger for smooth functioning of engine, testing complete all as directed .
S&F PVC insulated, heavy duty, unsheathed , multi Stranded Copper Cable of 35 Sqmm single core with suitable size lugs crimped on both side complete all as directed.
S&F Flexible Bellow suitable up to 125 KVA Gen Set. Make as per OEM
Disconnecting of alternator from 125 KVA to 250 KVA capacity DG set, after Disconnecting from Generator shifting to civil workshop, taking out burnt out winding from Stator & Rotator, Cleaning thoroughly and rewinding the stator, rotor with suitable gauge of super enameled copper conductor similar to that of existing size including necessary insulating material varnishing, heating, replacing bearings in rotor and stator side, reassembling of alternator, bringing back to the site refixing and installation over foundation with proper alignment, testing and commission complete all as directed. Note :- cost of taking up and down from the site to workshop vice versa with vehicle and necessary labour shall be deemed to be included in quoted rates.
All as per above item No.87 but for 320KVA to 630 KVA DG Set
Supply, fix and test run the Fly-wheel Ring of existing model, size suitable for DG set of capacity 63 to 250 KVA including taking down old unserviceable fly wheel ring complete all as directed.
Supply and fixing repairs Stanguard Auto Transfer switch (ATS) with enclouser of capacity 200 Amp 4 pole with automatic/manual with complete protection all accessorices complete all as directed.
Supply, Fix & test run the DG set after replacing Diesel feeder Pump of existing model, size suitable to DG Set of capacity up to 400 KVA including taking down old unserviceable diesel feeder pump complete all as directed.
Supply, Fix & test run the DG set after replacing Diesel feeder Pump of existing model, size suitable to DG Set of capacity 500 to 630 KVA including taking down old unserviceable diesel feeder pump complete all as directed.
M&L for removing old rusted painted from complete DG Set surfaces of the DG Set of capacity up to 125 KVA complete with one coat of Primer and two coats of (DECO) spray painting with existing colour paint synthetic enamel type including writing Ser No of DG set complete all as specified and directed.
Renewal of 3 pole 415 volts 50Hz Power Contractors of the following capacity including Connecting & testing complete all as directed by engineer-in Charge.
MNX 25 Contractor or its Equivalent
MNX 40 Contractor or its Equivalent
S&F Repair/ replacement of timer 0 to 60 min complete all as directed.
Comprehensive Annual Maintenance including rectification of any faults of various Fire Alarm Systems installed at DMRL,& ATC ,RCMA area including checking, testing, cleaning of Smoke Detectors, Heat Detectors, Beam Masters, Hooters, Manual Call Points, spirit bulbs etc. by carrying out preventive Maintenance and Corrective Maintenance rectifying defects in existing system and making the entire system trouble free and efficient functioning with all accessories connected to the Fire Alarm systems complete all as directed.
Note: (i) Spares if any required shall be measured and paid under the relevant items of schedule and cost of labour/Fire fighting Technician/ Engineer, element like Tools/Empty, cleaning agents etc are deemed to be included in the quoted rate. (ii) The preventive maintenance schedule shall be as follows:- (a) MONTHLY - Checking of all cards (control card, zone card, fail card, charger card etc) in control panel for their healthily working condition. Testing of all zones by checking smoke detectors at random with smoke testing of Hooters and MCPs. (b) QUARTERLY - cleaning of all smoke detectors, heat detectors, response indicators, hooters, MCPs and Beam masters and testing of all smoke detectors with smoke and heat detectors with heat. (iii) Service report is to be generated for the above monthly and quarterly maintenance for all the systems and submitting to Engr-in- Charge. (iv) Breakdown should be rectified as and when the system brakes down.
Testing and Refilling of Foam type Fire Extinguisher 9 Ltrs. Capacity complete fully charged gunmetal cap heavy inner container with wall mounting brackets etc. confirming to IS: 933. Make: Safex / Geo /Konex
Testing and Refilling of Dry Chemical Powder type Fire Extinguisher 5 Kg. Capacity powder and CO2 gas cartridge of 120 gms. Capacity confirming to IS: 2171.
Testing and Refilling of Dry Chemical Powder type Fire Extinguisher 9 Kg. Capacity powder and CO2 gas cartridge of 180 gms. Capacity confirming to IS: 2171.
Testing and Refilling of Carbon – Di – Oxide type Fire Extinguisher 4. 5 Kg. Capacity CO2 gas confirming to IS: 2878
Taking down old unserviceable hydrant valve and Supply, Installation, Testing and Commissioning of Single Headed Hydrant valve confirming to IS 5290 with ISI mark of size 63 mm dia oblique type with instantaneous hose coupling adaptor etc. with all necessary fitting materials complete required.
Taking down old unserviceable hydrant hose pipe and Supply, Installation, Testing and Commissioning of Hydrant hose pipe, 63 mm dia and 2x15 mtrs long RRL type with Gunmetal 63 mm size male coupling at one end and female coupling at the other end. It should with stand a bursting pressure of 450 psi, rot proofed, with ISI mark. Hose shall comply to IS 636
Taking down old unserviceable hose reel pipe and Supply, Installation, Testing and Commissioning of Fire Hose Reel pipe 20 mm dia. X 30 mtr. Long, high pressure with 5 mm out let GM nozzle with shut off valve(IS: 884 - 1969) includes stop cock and chromium plated nozzle with all necessary fixing materials complete all as directed.
S&F in repairs sprinkler bulb Spirit type 60 to 70 degree temperature fusible range suitable for fire fighting sprinkler system complete all as directed.
M&L for Scrapping of old existing paint of pipe lines for Fire fighting system of any sizes and applying two coats of enamel paint to match with the existing shade complete all as directed. Note - Rate quoted shall be deemed to include cost of Paint & tools.
Scrapping of old existing paint of Fire cabinet of size 0.75 X 0.6 X 0.25 (inside & outside) for Fire fighting system of any sizes and applying two coats of Red postal colour enamel paint. Note -Rate quoted shall be deemed to be include rates of Paint & tools.
M&L for rewinding of the electric motor of 60 HP capacity duly disconnecting and taking down electric motor from the existing position and inspecting the same, transporting to workshop for repairs and bringing back. Cutting and removing the burnt out winding conductors rewinding the same with same gauge and weight of insulated super enameled copper conductor and providing cotton insulated sleeves, varnishing, drying, refixing in position checking the alignment along with pump set connecting up with the electrical system, testing and commissioning complete all as directed.
Repair and servicing of 60 to 100 HP Fire Fighting Pump and motor including all connecting parts by replacing gland, greasing & oiling and rectification of alignment of pump and motor, cleaning the carbon from the electrical connections and commissioning complete all as directed.
Repair and servicing of 7.5 to 12.5 HP Fire Fighting Pump and motor including all connecting parts by replacing gland, greasing & oiling and rectification of alignment of pump and motor, cleaning the carbon from the electrical connections and commissioning complete all as directed.
S&F of following parts of Fire fighting system with all necessary electrical connection with lugs of any size and testing commissioning including taking down the same complete all as directed.
Contactor for fire Panel MNX 70 3Pole Make : L&T/C&S
Electronic Timers Type ET 100 ML-6, 9-30 Sec, 415V, 50 Hz Make : L&T/C&S
High Pressure control gauge 02-14 Bar, 0-55 PSI , KP-36 Make : Denfoss
S&F DWC pipe 40 mm HDPE double wall corrugated pipe cable ducting, underground electrical conduits complete all as specified and directed.
Periodical examination, normal and routine maintenance including cleaning of all parts and carrying out corrective maintenance for trouble free working repairs and replacement of spares in place of old unserviceable items including greasing of EOT/HOT Lifting Equipments of any make and model as available at site for the following capacities :-
EOT Lifting Equipments of 15 to 20 Ton capacity -04 Nos
EOT Lifting Equipements of 10 to 15 ton capacity -03 Nos
EOT Lifting Equipments of 5 to 10 ton capacity-02 Nos
EOT Lifting Equipments up to 5 ton capacity - 18 Nos (two No at ATC Devatalagutta)
HOT Lifting Equipments of up to 5 ton capacity -01 No Note for srl item Nos.1.01 to 1.05:- Supply only spares required will be measured and paid separately under relevant items. Fixing element is deemed to be included in the quoted rate.
Conducting of load and deflection test for the EOT and HOT Lifting Equipments of following capacities and submitting the test report to Engineer-in-Charge.
5 Ton to 10 Ton
10 Ton & up to 20 Ton
20 Ton & up to 25 Ton Note for item No 2.01 to 2.03 :- (a) The required loads are to be arranged by the contractor under his own arrangements including transporting to and fro the site without any extra cost to the department. (b) Lifting Equipments testing is to be carried out by the authorized inspector as per factory act. and the test certificate duly signed by authorized inspector will be submitted to Engr in charge.
M&L Gear Oil of suitable for Lifting Equipments gear assembly. Make:- Servo/Castrol or equivalent.
S&F in replacement PVC Junction box of size 250x200x100mm,light weight pole mounting including MCB SP 10Amps including necessary busbar MCB mounting arrangement and necessary connector for looping in and looping out cable connection and suitable glands including taking down old unserviceable junction box complete all as directed. Make :- SINTEX or techno commercially equal in Hensil and C&S
S&F in repairs GI street light with 4 feet mast arm for poles SP-25 to SP-31 as per the site requirements fixing on top of the pole with necessary nuts and bolts including shifting the existing street light from the bracket and connecting up with three core flexible cable by making necessary holes on the poles complete for passing the copper cable concealed in the pole including removing of spikes installed on existing pole complete all as directed.
Supply and fix in repairs Stanguard ON-LOAD Change over switch of capacity 200 amps to 400 Amp with advance neutral along with sheet steel enclosure/ panel mounted type as per site reqiurement (W/E) , AC23A ,415V, 50Hz, confirming to IS:13947-3 complete all as directed.
Supply and fix in repairs Stanguard ON-LOAD Change over switch of capacity 800 to 1000 amps with advance neutral along with sheet steel enclosure/ panel mounted type as per site reqiurement (W/E) , AC23A ,415V, 50Hz, confirming to IS:13947-3 complete all as directed.
S&F repair LED down light 12 W high colour rendering index (CRI>90) lumen efficacy of 100 Lm/W 2.5 KV voltage surg protection power factor > 0.9 housing made from powder coated die casted aluminium day light (5000K) complete all as specified and directed. Make:- BAJAJ CAT NO. BPSLR12WNW OR EQUIVALENT
S&F repair Mount LED Bollard light 10W Sturdy Imp 65 LED bollard with excellent light out put through its PMMA window ensuring maximum illumination aspect in surrounding including base foundation and nuts, bolts connections complete all as specified and directed. Make:- Shakti CAT NO SZPGBMX010 orHavells CAT NO. 10 W LED 857PSYMTOPPMMAM OR EQUIVALENT
S&F repair Mount Coral LED Post top Lamp 40W designed with symmetrical light distrubtion,spun aluminium landscape luminaries with high power LEDs as light source suitable for pole 40/50mm dia complete all as specified and directed. Make:- Shakti CAT NO SZPGMX0405 or Wipro OR EQUIVALENT
Supply & Laying, jointing & testing of XLPE UG LT cables, insulated, PVC sheathed aluminium conductor multi stranded armoured heavy duty 1100 Volt grade laid in trenches/ducts/along poles/through pipe under road etc with new aluminium lugs for the following cable sizes all as directed. Make: HAVELLS/UNIVERSAL/CCI/GLOSTER/KEI/POLYCAB/KEC INTERNATIONAL (RPG)
6 sqmm 4 core
10 sqmm 4 core
16 sqmm 4 core
25 sqmm 3.5 core
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables and getting out in soft/loose soil complete all as directed.
Returning, filiing in, including spreading, levelling watering and well ramming in layers not exceeding 25 cm thick each, using soil complete all as directed.
Removing excavated surplus soil obtained from excavation to a distance not exceeding 1.5 m above the starting point, complete all as specified.
S&F in repairs LED 90 watt street light fitting made up of pressure die cast housing with toughened glass and individual LEDs with street optics and IP 66 protection, 5700K including fixing to pole/wall with necessary copper wire twin core for connection from source to fitting, nuts, bolts and washers complete all as directed. Make Shakti Cat NO SZPSLPM090 or Havells, Model No:- ENDURAOMNIPLUSSL90WLED757SASYTOPC / Wipro Cat par No. LR02-102-XXX-57-G2 or Equivalent in Philips/ Crompton greaves/ Polycab
S&F in repairs of LED 45 watt street light fitting made up of pressure die cast housing with toughened glass and individual LEDs with street optics and IP 66 protection, 6500K including fixed to pole/wall with necessary copper wire twin core for connection from source to fitting, MS clamp & accessories complete all as directed. Make:- Shakti Cat NO SZPSLPM090 Havells cat part No: ENDURASUNDOWNSL45WLED765PASYBOPC / Wipro cat part No. LR-02-501-XXX-57-XX or Equivalent in Philips/ Crompton greaves/ Polycab
S&F in repairs LED street light 60 W secondary optics made in pressure die cast housing and heat shrink in aluminium extrusion and IP 66 protection, 5700K color temperature fixing to the bracket or street light pole with necessary copper wire twin core for connection from source to fitting nuts and bolts as required at site complete all as directed. Make:-Shakti Cat NO SZPSLPM060 or Havells cat part No: ENDURAOMNIPLUSSL60WLED757SASYTOPC /Wipro Cat part No.LR02-331-XXX-67-XX or Equivalent in Philips/ Crompton greaves / Polycab
S&F in repairs LED street light 100 W secondary optics made in pressure die cast housing and heat shrink in aluminium extrusion and IP 66 protection, 5700K color temperature fixing to the bracket or street light pole with necessary copper wire twin core for connection from source to fitting nuts and bolts as required at site complete all as specified and directed. Make:- Shakti Cat NO SZPSLPM100 or Havells Model No: ENDURAOMNIPLUSSL100WLED757SASYTOPC / Wipro Cat part No.LR06-311-XXX-67-XX or Equivalent in Philips/ Crompton greaves/ Polycab
S&F in repairs LED 250 watt high mast/flood light fitting made up of pressure die cast housing with toughened glass and individual LEDs with IP 66 protection, 5700K including fixing to High mass pole/truss with necessary copper wire twin core for connection from source to fitting nuts, bolts and washers complete all as directed. Make Shakti SZCFLPH250 or Philips, Model No:- BVP483 LED185 CW SWB PSU GR or Equivalent in Havell's Crompton greaves / Polycab
S&F in repairs LED 150 watt high mast/flood light fitting made up of pressure die cast housing with toughened glass and individual LEDs with IP 66 protection, 5700K including fixing to High mass pole/truss with necessary copper wire twin core for connection from source to fitting nuts, bolts and washers complete all as directed. Make Shakti SZCFLPH150 or Philips, Model No:- BVP483 LED185 CW SWB PSU GR or Equivalent in Havell's Crompton greaves /Polycab
S&F in repairs LED 100 watt high mast/flood light fitting made up of pressure die cast housing with toughened glass and individual LEDs with IP 66 protection, 5700K including fixing to High mass pole/truss with necessary copper wire twin core for connection from source to fitting nuts, bolts and washers complete all as directed. Make Shakti SZCFLPH100 or Philips, Model No:- BVP483 LED185 CW SWB PSU GR or Equivalent in Havell's Crompton greaves / Polycab
S&F in repairs LED 120 watt highbay light fitting made up of pressure die cast housing with toughened glass and individual LEDs with IP 66 protection, 5700K including fixing to High mass pole/truss with necessary copper wire twin core for connection from source to fitting nuts, bolts and washers complete all as directed. Make Shakti SZHHCPX120 or Havells, Model No:- SAUCERGENXHBP120WLED757P90DBOLTG or Equivalent in Philips/ Crompton greaves / Polycab
S&F in repairs LED 150 watt highbay light fiitting made up of pressure die cast housing with toughened glass and individual LEDs with IP 66 protection, 5700K including fixing to High mass pole/truss with necessary copper wire twin core for connection from source to fitting nuts, bolts and washers complete all as directed. Make Shakti SZHHCPX150 Havells, Model No:- CERGENXHBP150WLED857PNBBORL or Equivalent in Philips/ Crompton greaves / Polycab
Re-stringing, tightening and fixing in position, the existing OH ACSR conductor LT Line phase with neutral and earth wire 230V, 2/3 wire by loosening and taking down existing binding wire from the insulator of any size of ACSR conductor and bringing it to required sag including provision of new binding wire and tightening of cross arms on each pole and required trimming of tree branches Note: 1.Span length (for each conductor)of conductor shall be measured in running meter unit. 2.Unit rate quoted by the contractor shall be deemed to include for cutting and trimming branches of the trees coming in contact with ACSR conductor and separators as directed.
Cutting/ trimming / punning tree branches overhanging or interfering or obstructing electrical pole or street lights in such a way that the clearance between Street light pole and tree branches should not be less than 3 mtrs around the Pole/Fitting complete all as directed. (Note: Quoted rate is deemed to include necessary hydraulic ladder arrangement and tree cutting machine and tools required at site.)
M&L for scrapping down and removing of old deteriorated paint from steel tubular poles LT preparing surface for painting and applying black & yellow paint strips of 30 cms each up to 1.5 m above the PCC and applying one coat of red oxide and two coats of aluminium paint for the remaining height of pole including MS clamps, GI bracket, fittings etc and marking of pole No, 2m above the PCC muff, letter shall not be more than 6 cm height with 16 cm dia circle around the marked No. complete all as directed. Note : Quoted rate is deemed to include removal of any type of boards, direction plates etc and refixing the same after painting, in its original position with necessary bolts and nuts.
S&F in repairs automatic timer switch distribution board, factory assembled in powder coated sheet steel enclosure, 3Phase, suitable up to 12KW load, comprising of 32 Amps, 3 Pole, MCB TPN, 40A power contactor and 415V digital timer switch for controlling street lights outdoor type, including angle iron base and stand for fixing the panel with suitable PCC foundation as per site requirement . Make: Havells Cat Part: IHXSS01060 or equivalent in L&T/Legrand/Indo Asian
S&F in repairs automatic timer switch distribution board, factory assembled in powder coated sheet steel enclosure, suitable for up to 5KW load single phase comprising of 25 Amps SP MCB, 25A power contactor and 230V digital timer switch for controlling street lights, including angle iron base and stand for fixing the panel with suitable PCC foundation as per site requirement . Make: Havells Cat Part No : IHXTS09120 or equivalent in L&T/Legrand/Indo Asian Note:- Rate quoted shall be inclusive of necessary excavation & earth work and PCC foundation.
S&F in repairs polymer white , Grey or Green Pin type shakle type or any type LT as per site requirement insulator of 1.1KV grade including one galvanized mild steel strap washers, bolts, washers and nuts complete all as directed. Make - Rashtriya Electrical/ BHEL/ National
S&F, in repairs stay assembly complete with accessories as shown in electrical plate No.1 of SSR part I including loop type insulator, stay clamps, stay strands, excavation & earthwork and PCC work complete all as specified and directed. Note:- Rate quoted shall be inclusive of necessary excavation & earthwork and concrete as required.
M&L for painting the pole number on the LT/Street Light pole in circular shape with black synthetic enamel paint background and white synthetic enamel painted letters. Note:- The numbers and words shall be all as directed by the Engineer-in-charge.
S&F Electronic driver for 20/25 watts LED security light fittings Make : Is certified
S&F Electronic driver for 36/35 watts LED security light fittings Make : Is certified
S&F Electronic driver for 45/50 watts LED road way/Flood light/post top Make : Is certified
S&F Electronic driver for 60/70 watts LED road way/Flood light/post top Make : Is certified
S&F Electronic driver for 90/100 watts LED road way/Flood light/post top Make : Is certified
S&F Electronic driver suitable for 120watts LED street light/Flood light fittings. Make : Is certified
S&F Electronic driver suitable for 150watts LED street light/Flood light fittings. Make : Is certified
M&L for MS plate/sheet plain or cheuered,4.00 mm thick cut to pieces as required and fixed to MS frame work by means of electric arc/gas welding all as directed and specified including dismantling existing MS work .
M&L for Preparation of metal surfaces of any description, applying two coat of synthetic enamel paint of color as directed by the Engr-in-charge over a coat of red oxide primer complete.
Supply and spreading of natural, clean, dry, river sand in trenches for cable protection / transformer yard/ two pole structure yard complete all as directed. Note:- Punned thickness only shall be measured for payment purpose.
M&L for laying of common burnt bricks, sub class 'B', old size 230 x 115 x 75 mm in trenches for cable protection complete all as directed.
Supply and fix GI tubing 50 mm Tubes, 'light grad', galvanized, with all fitting; laid in trenches complete all as directed.
S.S.ENGINEERING CORPORATION
UNITY ENGINEERING TRADERS
Richcon Engineers
vvcenterprises
Anjana corporation
shyam engineerings
Venkat Sai Enterprises
ELEVATORS MAINTENANCE ENGINEER WORKS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .