| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC | L1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L2₹22.0 L+₹2.2 L (11.1%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹23.7 L+₹3.9 L (19.5%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹24.3 L+₹4.5 L (22.9%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹25.0 L+₹5.2 L (26.2%)Rejected-AOC 01 DUDWAN KUPWARA DUDWAN KUPWARA JAMMU KASHMIR 193222 UDYAM JK 12 0031214 | KUPWARA | JAMMU AND KASHMIR | 193222 | L5 | Rejected-AOC Rejected |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
3 Jun 2023, 6:00 pmClosed
GE AF SRINAGAR
GE AF SRINAGAR AF STN SRINAGAR 190007
REPAIR/REPLACEMENT TO ALUMINIUM DOORS, WINDOWS, FALSE CEILING, STEEL GATES AND OTHER MISC WORK UNDER GE (AF) SRINAGAR.
2023_MES_594416_1
GE(AF)SGR- 08 OF 2023-24
Open Tender
Civil Works
Item Rate
365 days
GE AF SRINAGAR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE AF Srinagar
₹50,000
Yes
20 Jul 2023
10 May 2023
5 Jun 2023
10 May 2023
3 Jun 2023
27 May 2023
Amount
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.50 Sqm each complete all as specified and as directed by the Engineer-in-Charge
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.50 Sqm but n exc 4.00 Sqm each complete all as specified and as directed by the Engineer-in-Charge.
Taking down shutters of any description exc 1 Sqm and n exc 2 sqm.
Taking down, easing, adjusting of old wooden shutters of any description exc. 1 Sqm and not exc. 2 Sqm each and refixing in same opening after tiling work complete all as directed by Engr-in-charge.
M & L for Easing of Aluminium Door /shutters/CB/ Sliding windows (One unit shall comprise of one window/CB/Showcase irrespective of number of leaves) for properly closing/opening, tightening of thing, adjustement of tower bolts, sliding bolt etc replacement of rubber beading complete all as specified and directed.
S&F Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified complete all as specified and directed by Engineer-in-Charge
M & L for Anodised aluminium door shutters, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, 150 mm handles 2 Nos in each door shutter, 100 mm hinges-03 Nos, 150mm tower bolt -02 nos in each shutter anodised aluminium snap beading, screws etc. complete all as specified and directed by Engineer-in-Charge.
M & L for Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinge type B-21, 100mm long (2 no) suitable handle (1 no), complete all as specified and directed by Engineer-in-Charge.
S & F sheet glass 5.5mm thick, ordinary quality and glazing with aluminium glazing clips and rubber neosprine gasket in square or rectangular, complete all as specified and directed by Engineer-in-Charge.
S&F aluminium composite panels, 5mm thick as in doors, of any colour, shape, size and design fixed on aluminium frame work including all necessary fittings and fixtures and necessary taping, complete all as per manufactures instructions, complete all as specified.
S & F in repair 12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work
S&F sheet glass 3mm thick, ordinary quality and glazing with oil putty/wooden beads/ aluminium beading in square or rectangular in section n exc 0.5 sq.m in each pane including Hacking out old broken glass complete all as specified and directed by Engineer-in-Charge.
S & Fin repair Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples
S & F Figured Glass pin head type 4mm thick n exc 0.5 Sqm and glazing with oil putty, Complete all as specified and directed by Engineer-in-Charge
S&F 100 mm size butt hinges, Stainless Steel complete all as specified and as directed by Engineer-in-Charge.
S&F 150 mm long aluminium anodized barrel tower bolts of extruded section complete .
S&F 150 mm size, aluminium anodized handles, cast type complete all as specified and directed by Engineer-In-Charge.
S & F 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
S & F in repair stainless steel lock for aluminium door, size 100 mm , 2 levers complete all as specified and directed by Engineer-in-Charge
S & F sheet glass 5.5mm thick, ordinary quality and glazing with aluminium glazing clips and rubber neosprine gasket in square or rectangular including hacking out old broken glass, complete all as specified and directed by Engineer-in-Charge.
S&F in repair Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring fixed in floor of Overall length of cover plate 140 mm all as specified and directed by Engineer-in-Charge
S&F in repair Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel over, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed by Engineer-in-Charge
S & F in repair Aluminium (Extruded Section body) Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed
M & L for wooden panelling of second class softwood 12mm thick with tongue and groove joint fixed in any position over and including wooden framework in second class softwood with plain fillets square or sectional area exc 13 Sqcm and n exc 25 Sqcm at n exc 90 cm centre to centre in both direction and including two or more coat of french polishing on all the exposed surfaces wooden panelling including taking down existing electrical fittings and re-fixing the same locations as directed complete all as specified and as directed by Engineer-in-Charge.
M & L ACP wall cladding 4mm thick fixing with 25x40mm aluminium tube section or as per manufacturer instruction including joint filling and taping, necessary arrangement and colour will be as approved by GE, including taking down existing PGI sheets complete all as specified and directed.
S & F stainless steel alphabets letters (not less than 2.5mm thick) of height of letter exc 200 but not exc 300 mm and width 25 to 30 mm including fixing arrangements (Font of letters as directed by Engr-in Charge) complete all as specified and directed.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed by Engineer-in-Charge.
M & L for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre, complete all as specified and directed by Engineer-in-Charge.
M &L for Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions including necessary jointing and taping, and applying 1mm thick putty to receive finishes complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 12mm thick Particle board for insulation purposes as in false ceiling, fixed with nails to timber framework design and pattern of board as approved by Engr-in-Charge.
S&F snap grid for false ceiling of size 600 mm x 600 mm grid EXPOSED GRID SYSTEM fabricated with glavanised iron powder coated section all as shown on serial page No 185 of SSR part II (2020 print) complete all as specified directed by the Engineer-in-Charge.
M &L for 12mm thick Perforated particle board/ tiles for insulation and accoustic purposes, 60x60 cm in size, fixed with nails to timber frame workorwith staples on snap grid complete all as specified and directed by Engineer-in-Charge.
S & F in repair 6mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws putty to receive finishes complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old ceiling surface and applying one coats of distemper oil emulsion (OBD) including complete all as specified and as directed by Engineer-in-Charge
M & L for second class hardwood fillets bullnosed, splayed, chamfered or rounded on one edge or face of exc 13 Sqcm but not exc 25 sqcm in repairs, secured with nails or screws in repairs , complete all as specified and directed by Engineer-in-Charge.
M & L for second class hardwood plain fillets, square or rectangular or triangular in section clean sawn exc 6 Sqcm but not exc 13 sqcm in repairs, secured with nails or screws in repairs , complete all as specified and directed by Engineer-in-Charge.
M&L for 6mm thick Non asbestos fibre cement building fixed or laid/inserted to timber/GI/Aluminium framework with screws to ceiling flat or sloping, fixed in repair complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new or previouly untreated plaster/ AC sheet/Gypsum board surfaces of ceiling including cornices and applying two coats of oil bound distemper colour/tint complete all as specified and directed by Engineer-in-Charge.
Demolition of Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
M & L for hardcore of gauge not exceeding 63 mm of broken stone, deposited, spread and levelled layers not exceeding 15 cm thick, watered and rammed to a true surface.Completed all as specified and directed.
M&L for Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete.
M & L for Providing and laying at or near ground level factory made kerb stone of PCC 1:2:4 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete completed all as specified and directed.
M&L for glossy finished rubber moulded machine pressed precast concrete coloured interlocking paver block 60mm thick rubber moulded any shape and size over and incl 25 mm thick sand layer conforming to IS 15658-2006 of grade M-35 with grey cement and no pigments complete all as specified.
M&L for 75mm thick cement concrete1:3:6 type C1 using 20mm graded stone aggregate as in plinth protection joint filled with bitumen sand mixer finished even and smooth without using extra cement.
M & L Cement concrete Type D2 1:4:8 (40 mm graded aggergate) in foundations, filling and mass concrete
Demolition of brickwork built in cement mortar including all quoins, arches, pillars etc incl removal of rubbish out of defence land complete all as specified and as directed by Engineer-in-Charge.
M & L for Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1: 6, using old size bricks complete all as specified and as directed by Engineer-in-Charge.
All as per item No 47 above here-in-before but except bricks.
M & L for Brick work with sub class ‘B’ bricks, straight or curved on plan any radius in half brick thick wall built in cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge.
Taking down cement plaster/cast in situ terrazo of any description on brick walls or concrete surfaces etc. including racking out joints, hacking for key, scrubbing down with water complete all as specified and directed by the Engineer-In-Charge. (The rate quoted by the contractor shall included for welded mesh, scaffolding and necessary formwork upto triple storey bldg).
M & L for rendering 15 mm thick on other than fair faces of brick wall finished fair & even in CM 1:6 complete all as specified and directed.
M & L for rendering 15 mm thick on fair faces of brick wall finished fair & even in CM 1:4 complete all as specified and directed.
M & L for rendering 10 mm thick on brick or concrete surface of ceiling finished fair & even in CM 1:3 complete all as specified and directed.
M & L preparation of newly plastered surfaces of ceiling and applying three coats of white wash on ceiling, complete all as specified and directed.
M & L preparation of newly plastered surfaces of wall and applying two coats of OBD over a coat of putty filling including preparation of surfaces on walls as specified and directed .
M & L preparation of newly plastered surfaces of wall and applying three coats of white wash, complete all as specified and directed.
M&L Preparing of new surface of wall and applying two coats of cement based paint over one coat of primer.
Dismantling floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish off the premises.
M&L Coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick Screed bed or bedding layer of mortar for laying floor finishes in CM 1:6
All as per item No 59 above here-in-before but in Skirting including 10 mm thick backing coat cement mortar 1:4.
M& L Double Charged Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick Screed bed or bedding layer of mortar for laying floor finishes in CM 1:6.
All as per item No 61 above here-in-before but in Skirting including 10 mm thick backing coat cement mortar 1:4.
Material and labour 1st quality vitrified parking tiles in approved shade in minimum 12 mm thickness from meteor series, area of each tile exceeding 0.08 sqm but not exceeding 0.18 sqm in floors etc, set & jointed in neat cement slurry & pointed in matching coloured polymer cement based grout to match including 15 mm thick Screed bed or bedding layer of mortar for laying floor finishes in CM 1:6 complete all as specified and directed by Engineer-in-Charge. Make :Johnson Endura meteor (Korneto Biege) or equivalent make in Appx A.
S & F in repair 1.5mm thick Polycarbonate sheet fixed with self tapping stainless steel screw and washer complete all as specified and directed by Engineer-in-Charge.
S & F Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers
S & F 12mm thick toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required
M & L for etching on toughened glass designed and pattern as approved by Engr-in-Charge
S & F stainless steel handle 450mm size & 25mm dia suitable for toughened glass door complete all as specified and directed by Engineer-in-Charge.
S& F 2 levers stainless steel floor lock suitable for toughened glass door complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for
M & L Framed work as Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc. Fe- 410 (Gde E- 250) (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
M&L for preparation of new steel surface and iron surfaces and applying two coat of synthetic enamel paint over one coat red oxide primer of any description over 10cm width or girth complete all as specified and directed by Engineer-in-Charge
S & F Powder coated superior quality venetian blinds horizontal or vertical type complete all as specified and directed by Engineer-in-Charge.
Blank
Taking down existing hangar/BP door shutter size exc 12 sqm but n.exc 50 sqm each, cutting through gas welding with necessary arrangements for lifting door through jack for removing hangar door top/bottom wheel and refixing after making good as per existing for smooth functional of door complete all as specified and directed. Note: - Any accessories required shall be measured and paid separately
S & F of hangar/BP door wheel of size upto 300 mm dia of the Ball bearing of size as per existing wheel inside the top wheel/Bottom wheel assembly properly with greasing etc. complete all as specified and directed.
M/S MAQBOOL BHAT & SONS
M/S GULZAR ENTERPRISES
M/S BASHIR AND SONS
M/S WANI AND SONS
M/S LUCKY BUILDERS
M/S Thakur & Sons
M/S RATHER CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .