Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 LAccepted-Finance H NO 193 2 MINTRA BARAR TALEIGAO | ₹3.9 L | L1 | Accepted-Finance Lowest Amount Quoted. |
| 2 | L2₹4.3 LRejected-Finance | ₹4.3 L | L2 | Rejected-Finance Rejected. |
| 3 | L3₹4.6 LRejected-Finance | ₹4.6 L | L3 | Rejected-Finance Rejected. |
| 4 | Rejected-Technical 466 ST DOMINGOS CABESA SANTA CRUZ TISWADI GOA | SANTA CRUZ | TISWADI | GOA | - | - | Rejected-Technical Self-Decleration not as per the circular, hence rejected. |
Tender Value
₹4.9 L
EMD Value
₹9,787
Closing Date
27 Apr 2026, 3:00 pmClosed
Executive Engineer I
Executive Engineer I, WDI(Bldgs.) PWD, Panaji Goa.
Urgent repairs to C-0-6, C-0-2 and I-1-1 B type qtrs at Bhatlem.
2026_PWD_28778_1
PWD/WDI/ASW-17/2026-27/04/08
Open Tender
Civil Works - Buildings
45 days
Executive Engineer I, WDI(Bldgs.) PWD, Panaji Goa.
Please refer Tender documents.
3 documents required · 3 mandatory
₹4,000
₹9,787
12 May 2026
17 Apr 2026
28 Apr 2026
17 Apr 2026
27 Apr 2026
17 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Repairs to plaster in patches of 2.5 sq.m. and under including cutting the patch in proper shape and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50m lead.;With cement mortar 1:4 (1 cement : 4 fine sand) | - | sq.m | - | - | itemcode01 |
| 2 | Removing old loose bottom or side cover of RCC slab beam columns etc. rubbing surface of concrete steel using wire brush and applying 2 coats of Alkaline rust converting primer (Feovert) after a waiting time of 6 hrs between coats and then applying another anti corrosive protective coating system ) for reinforcement bars (IPNet-RB) Conforms to IS-2770 Part-1 (Pull out Test) ASTM-3963-86 (Adhesion Test) and then applying concrete penetrating corrosion inhibitor (EPCO-KP100) and applying bonding new to old concrete (Epibond) Conforms to ASTM-C-882-87 and plastering on the fresh bond coat with Polymer Modified Mortar (Monobond) with 20mm C.M 1:3 and finishing coat of 6mm C.P 1:3 (1 Cement : 3 Sand ) incl. cost of transport etc. as per dir of EIC. All the chemicals will be of Krishna Conchem Products Pvt. Ltd. or Equivalent. | - | sq.m | - | - | itemcode02 |
| 3 | Crack filler for plasters IPS cement sand screeds and non – structural cracks. Do Not open the cracks Clean the cracks so as to free them from oil dust loose particles etc. Moisten the surface with water Fill cracks with EPCO – ACR using spatula or a putty knife. While applying avoid formation of cavity or bubbles. After filling allow the surface to dry for at least 24 hours. Apply in layers at 24 hours interval. If the depth of the crack is more than 10mm. incl. cost of scaffolding transport etc. as per dir of EIC. All the chemicals will be of Krishna Conchem Products Pvt. Ltd. or Equivalen. | - | Metre | - | - | itemcode03 |
| 4 | Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer over the plastered wall surface to prepare the surface even and smooth complete. | - | sq.m. | - | - | itemcode04 |
| 5 | Removing dry or oil bound distemper by scrapping sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. | - | sq.m | - | - | itemcode05 |
| 6 | Distempering two or more coats with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade. | - | sq.m | - | - | itemcode06 |
| 7 | Providing and fixing anodised aluminium shutters in accordance with the specification annexed herewith including transportation, scaffolding and handling etc. complete as per direction of the Engineer-in-charge: Adjustable louvered windows.;Figured glass | - | sq.m | - | - | itemcode07 |
| 8 | Providing and and laying Ceramic glazed floor tiles 300 x 300 (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make in colours such as white ivory grey fume red brown laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc. complete | - | sq.m | - | - | itemcode08 |
| 9 | Providing and fixing anodised aluminium shutters in accordance with the specification annexed herewith including transportation, scaffolding and handling etc. complete as per direction of the Engineer-in-charge: windows with two sliding shutters using 18 mm series shutters section.;Figured glass | - | sq.m | - | - | itemcode09 |
| 10 | Extra for powder coating with pure polyester powder of shade of required colour on the aluminium section | - | sq.m | - | - | itemcode10 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
Tendernotice_2.pdf
PDF • 1.65 MB
BOQ_29217.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid