Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.0 LAccepted-AOC | ₹40.0 L Quoted ₹42.0 L | L1 | Accepted-AOC Lowest Bid Value |
| 2 | L2₹43.7 LRejected-AOC | ₹43.7 L | L2 | Rejected-AOC Higher bid value |
| 3 | L3₹45.0 LRejected-AOC | ₹45.0 L | L3 | Rejected-AOC Higher bid value |
| 4 | L4₹45.7 LRejected-AOC | ₹45.7 L | L4 | Rejected-AOC Higher bid value |
| 5 | L5₹47.5 LRejected-AOC HOUSE NO 99 3RD FLOOR SK JAIN BUILDING KALIBARI ROAD DIMAPUR 797112 NAGALAND | DIMAPUR | DIMAPUR | NAGALAND | 797112 | ₹47.5 L | L5 | Rejected-AOC Higher bid value |
| Sl No | Description | Qty | Unit | PERFECT BUILDERS AND SUPPLIERS L6 | M/S Lucky Builders L2 | SHRIi Bachulal shah L8 | M/s K P Enterprises L7 | commercial enterprises L3 | VAISHNO ASSOCIATES L5 | M/S VIKASH TRADERS L1 | Rameshwar Prasad L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, erecting, commissioning and testing new factory made LT panel board cubical out door type in repairs/replacement of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement panel base of angle iron 50x50x6 mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including TPN Aluminium bus bar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeves and shall be mounted on F class insulators. All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN Aluminium bus bar of rating not less than 1.5 times rated capacity of of individual outgoing feeders. All control wiring shall be with FRLS PVC insulated 6 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm and complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of copper lugs and suitable size chrome plated glands provided for incoming and out-going cables comprising the following :- | 3 | Each | 1,98,220 ₹5.9 L | 1,90,820 ₹5.7 L | 1,80,000 ₹5.4 L | 1,89,560 ₹5.7 L | 1,88,000 ₹5.6 L | 1,97,451 ₹5.9 L | 1,88,110 ₹5.6 L | 1,89,120 ₹5.7 L |
| 1.01Item 01 Contd.. INCOMING MCCB (a) 200 Amp 4 pole, 36 KA breaking capacity with adjustable thermal magnetic setting with earth fault protection Ics= 100% Icu, - 01 Nos. OUTGOING MCCB (a) 100 Amp 4 pole MCCB 36 KA breaking capacity with adjustable thermal magnetic setting with Ics= 100% Icu - 04 Nos. (b) 32 Amp MCB TPN - 01 No (c) Spare space for MCCB - 01 No Metering: a) AC digital voltmeter 0-500 volts Size 4"X4" with 3 Ph selector switch-01 Nos b) 0-500 digital Amp meter with suitable Size 4"X4" with 3 Ph selector switch- 01 Set. c) LED Indicating lamps RYB set of three -01 Sets Note : (a) Cable Entery should be Incoming/outgoing from seperate cable galley. (b) All Incoming/Outgoing MCCBs provide suitable size of copper connection plates. (c) All Incoming/Out going MCCBs provide spreader Links - 04 Nos Each. (d) Provision of gland hole, brass glands as per direction of Engr-in-Charge. (e) All Incoming/out goings MCCBs should be Marking label/End plate/End clams/suitable size of Terminal Block Stud/screwless type etc (f) Main busbar/link bus bar should be full covered back size also. | |||||||||||
| 2.00 | Supply, installation, erecting, commissioning and testing new factory made LT panel board cubical out door type in repairs/replacement of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement panel base of angle iron 50x50x6 mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including TPN Aluminium bus bar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeves and shall be mounted on F class insulators. All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN Aluminium bus bar of rating not less than 1.5 times rated capacity of of individual outgoing feeders. All control wiring shall be with FRLS PVC insulated 6 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm and complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of copper lugs and suitable size chrome plated glands provided for incoming and out-going cables comprising the following :- | 2 | Each | 1,89,115 ₹3.8 L | 1,76,000 ₹3.5 L | 2,50,000 ₹5 L | 1,95,650 ₹3.9 L | 1,82,410 ₹3.6 L | 1,94,118 ₹3.9 L | 1,78,110 ₹3.6 L | 1,89,010 ₹3.8 L |
| 2.01Item 02 Contd.. INCOMING MCCB (a) 250 Amp 4 pole, 36 KA breaking capacity with adjustable thermal magnetic setting with earth fault protection with Ics= 100% Icu, - 01 Nos. OUTGOING MCCB (a) 100 Amp 4 pole MCCB 36 KA breaking capacity with adjustable thermal magnetic setting Ics= 100% Icu - 02 Nos. (a) 125 Amp 4 pole MCCB 36 KA breaking capacity with adjustable thermal magnetic setting Ics= 100% Icu - 02 Nos. (b) 32 Amp MCB TPN - 01 No (c) Spare space for MCCB - 01 No Metering: a) AC digital voltmeter 0-500 volts Size 4"X4" with 3 Ph selector switch-01 Nos b) 0-500 digital Amp meter with suitable Size 4"X4" with 3 Ph selector switch- 01 Set. c) LED Indicating lamps RYB set of three -01 Sets Note : (a) Cable Entery should be Incoming/out going from seperate cable galley. (b) All Incoming/Out going MCCBs provide suitable size of copper connection plates. (c) All Incoming/Out going MCCBs provide spreader Links - 04 Nos Each. (d) Provision of gland hole, brass glands as per direction of Engr-in-Charge. (e) All Incoming/out goings MCCBs should be Marking label/End plate/End clams/suitable size of Terminal Block Stud/screwless type etc (f) Main busbar/link bus bar should be full covered back size also. | |||||||||||
| 3.00 | Supply, installation, erecting, commissioning and testing new factory made Bus Bar panel board cubical out door type in repairs/replacement of size 0.750 MtrX 0.600mtrX0.500mtr for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement panel base of angle iron 50x50x6 mm upto 60 cm legs & bottom channel of size 75 x 40 mm for 433 volts, 3 phase, 4 wire system including TPN Aluminium bus bar of rating 250A, 4Pole The TPN bus bar shall be insulated with colour coded heat shrinkable sleeves and shall be mounted on F class insulators.
Note : Bus bar should be fixed on PCC and its rate included in quoted rate. | 5 | Each | 79,741 ₹4.0 L | 43,500 ₹2.2 L | 32,000 ₹1.6 L | 54,540 ₹2.7 L | 44,450 ₹2.2 L | 51,445 ₹2.6 L | 43,750 ₹2.2 L | 43,900 ₹2.2 L |
| 4.00 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft/ loose soil complete all as specified and as directed. | 513 | Cum | 415 ₹2.1 L | 450 ₹2.3 L | 1,050 ₹5.4 L | 390 ₹2.0 L | 460 ₹2.4 L | 410 ₹2.1 L | 340 ₹1.7 L | 390 ₹2.0 L |
| 5.00 | Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all complete all as specified and as directed. | 343 | Cum | 210 ₹72,030 | 180 ₹61,740 | 400 ₹1.4 L | 180 ₹61,740 | 190 ₹65,170 | 190 ₹65,170 | 130 ₹44,590 | 220 ₹75,460 |
| 6.00 | Removing of excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all complete all as specified and as directed. | 170 | Cum | 252 ₹42,840 | 230 ₹39,100 | 400 ₹68,000 | 260 ₹44,200 | 215 ₹36,550 | 233 ₹39,610 | 200 ₹34,000 | 230 ₹39,100 |
| 7.00 | M&L for spread fine river sand in trenches complete all as specified and as directed.
Note: Punned thickness shall be measured and paid. | 121.5 | Cum | 2,200 ₹2.7 L | 2,300 ₹2.8 L | 400 ₹48,600 | 2,600 ₹3.2 L | 2,400 ₹2.9 L | 1,900 ₹2.3 L | 2,148 ₹2.6 L | 2,380 ₹2.9 L |
| 8.00 | M&L for laying brick sub class 'B' (using old size burnt bricks) for cable protection of size 230mmx115mmx75mm complete all as specified and as directed | 15,200 | Each | 21 ₹3.2 L | 15 ₹2.3 L | 12 ₹1.8 L | 21 ₹3.2 L | 15 ₹2.3 L | 19 ₹2.9 L | 13 ₹2.0 L | 18 ₹2.7 L |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
20 Apr 2026, 6:00 pmClosed
GE 868 EWS
GE 868 EWS PIN- 913 868 C/o 99 APO
REPAIR OR MAINT OF LT BUS BAR FEEDER PILLAR BOXES MAINT OF SUB STNS PAINTING AND OTHER MISC WORKS
2026_MES_758527_1
8968/C/E8
Open Tender
Electrical and Maintenance Works
270 days
RANGAPAHAR
Class D, Category b(i)
2 documents required · 2 mandatory
₹500
GE 868 EWS
₹80,000
15 May 2026
30 Mar 2026
22 Apr 2026
30 Mar 2026
20 Apr 2026
13 Apr 2026
30 Mar 2026 - 6 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
Supply, installation, erecting, commissioning and testing new factory made LT panel board cubical out door type in repairs/replacement of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement panel base of angle iron 50x50x6 mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including TPN Aluminium bus bar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeves and shall be mounted on F class insulators. All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN Aluminium bus bar of rating not less than 1.5 times rated capacity of of individual outgoing feeders. All control wiring shall be with FRLS PVC insulated 6 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm and complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of copper lugs and suitable size chrome plated glands provided for incoming and out-going cables comprising the following :- | - | Each | - | - | |
Item 01 Contd..
INCOMING MCCB
(a) 200 Amp 4 pole, 36 KA breaking capacity with adjustable thermal magnetic setting with earth fault protection Ics= 100% Icu, - 01 Nos.
OUTGOING MCCB
(a) 100 Amp 4 pole MCCB 16 KA breaking capacity with adjustable thermal magnetic setting with Ics= 100% Icu - 04 Nos.
(b) 32 Amp MCB TPN - 01 No
(c) Spare space for MCCB - 01 No
Metering: a) AC digital voltmeter 0-500 volts Size 4"X4" with 3 Ph selector switch-01 Nos
b) 0-500 digital Amp meter with suitable Size 4"X4" with 3 Ph selector switch- 01 Set.
c) LED Indicating lamps RYB set of three -01 Sets
Note : (a) Cable Entery should be Incoming/outgoing from seperate cable galley.
(b) All Incoming/Outgoing MCCBs provide suitable size of copper connection plates.
(c) All Incoming/Out going MCCBs provide spreader Links - 04 Nos Each.
(d) Provision of gland hole, brass glands as per direction of Engr-in-Charge.
(e) All Incoming/out goings MCCBs should be Marking label/End plate/End clams/suitable size of Terminal Block Stud/screwless type etc
(f) Main busbar/link bus bar should be full covered back size also. | - | - | - | - | |
Supply, installation, erecting, commissioning and testing new factory made LT panel board cubical out door type in repairs/replacement of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement panel base of angle iron 50x50x6 mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including TPN Aluminium bus bar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeves and shall be mounted on F class insulators. All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN Aluminium bus bar of rating not less than 1.5 times rated capacity of of individual outgoing feeders. All control wiring shall be with FRLS PVC insulated 6 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm and complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of copper lugs and suitable size chrome plated glands provided for incoming and out-going cables comprising the following :- | - | Each | - | - | |
Item 02 Contd..
INCOMING MCCB
(a) 250 Amp 4 pole, 36 KA breaking capacity with adjustable thermal magnetic setting with earth fault protection with Ics= 100% Icu, - 01 Nos.
OUTGOING MCCB
(a) 100 Amp 4 pole MCCB 16 KA breaking capacity with adjustable thermal magnetic setting Ics= 100% Icu - 02 Nos.
(a) 125 Amp 4 pole MCCB 16 KA breaking capacity with adjustable thermal magnetic setting Ics= 100% Icu - 02 Nos.
(b) 32 Amp MCB TPN - 01 No
(c) Spare space for MCCB - 01 No
Metering: a) AC digital voltmeter 0-500 volts Size 4"X4" with 3 Ph selector switch-01 Nos
b) 0-500 digital Amp meter with suitable Size 4"X4" with 3 Ph selector switch- 01 Set.
c) LED Indicating lamps RYB set of three -01 Sets
Note : (a) Cable Entery should be Incoming/out going from seperate cable galley.
(b) All Incoming/Out going MCCBs provide suitable size of copper connection plates.
(c) All Incoming/Out going MCCBs provide spreader Links - 04 Nos Each.
(d) Provision of gland hole, brass glands as per direction of Engr-in-Charge.
(e) All Incoming/out goings MCCBs should be Marking label/End plate/End clams/suitable size of Terminal Block Stud/screwless type etc
(f) Main busbar/link bus bar should be full covered back size also. | - | - | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
Tender8968.pdf
Tender Documents • 1.47 MB
BOQ_849595.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid