| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAccepted-AOC SHREE KUNJ HOUSE NO 22B JIBAN KRISHNA PATH NEAR L P SCHOOL HENGRABARI GUWAHATI PIN 781036 | GUWAHATI | KAMRUP | ASSAM | 781036 | ₹2.0 Cr | L1 | Accepted-AOC Being L1 Bidder |
| 2 | L2₹2.1 Cr+₹14.4 L (7.20%)Rejected-Finance H NO 6 1ST FLOOR P B ROAD SUHAGPUR REBARARI GUWAHATI 08 | GUWAHATI | ₹2.1 Cr+₹14.4 L (7.20%) | L2 | Rejected-Finance Not being L1 Bidder |
| 3 | L3₹2.2 Cr+₹17.1 L (8.56%)Rejected-Finance H M APARTMENT FLAT NO 5C SJ ROAD ATHGAON GUWAHATI 781001 ASSAM | KAMRUP METRO | ASSAM | 781001 | ₹2.2 Cr+₹17.1 L (8.56%) | L3 | Rejected-Finance Not being L1 Bidder |
| 4 | L4₹2.6 Cr+₹57.2 L (28.7%)Rejected-Finance | ₹2.6 Cr+₹57.2 L (28.7%) | L4 | Rejected-Finance Not being L1 Bidder |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not being eligible bidder as per NIT conditions |
Tender Value
₹2.0 Cr
EMD Value
₹2.7 L
Closing Date
22 Oct 2022, 6:00 pmClosed
CHIEF ENGINEER AF SHILLONG
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
ADDN/ALTN TO AC PLANTS AT SHED NO. 58 AND 59 AT AF STN DIGARU
2022_MES_551085_1
88448/DIG/E8
Open Tender
Civil Works
Item Rate
DIGARU
Please refer tender documents
8 documents required · 8 mandatory
₹1,000
AGE I AF DIGARU
₹2.7 L
Yes
28 Nov 2022
9 Sept 2022
24 Oct 2022
9 Sept 2022
22 Oct 2022
8 Oct 2022
Amount
B/R PORTION
Taking down chowkhats or frames exc 1.5 sqm but not exc 4 sqm each with shutter (without taking of shutters from the frames) all as specified and as directed.
Taking down cement plaster of any description on brick or stone walls etc including racking out joints, hacking for keys, scrubbing down with water etc complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre,pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillets complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete as specified and directed.
M&L for Brick work with sub class 'B' bricks (old size) straight or curved on plan exc 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for preparation of newly plastered surfaces of internal walls, etc and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed.
S&F Anodised aluminium snap grid frame work main Tee & cross Tee size 25.40X25.40X1.63 mm supported at ends with 38.10X25.40X1.32 mm forming grid 600x600 mm for false ceiling, suspended with 6 mm GI wire , (upto 1200mm length). Adjusting level fixed to roof slab by means of ceilling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasterners 12.5mm dia 40 mm long complete as per manufacturer's instructions including fixing of nut, bolt and clamps with the help of drilling machine complete all as specified and as directed
M&L for providing and fixing gypsum board, 12 mm thick, in ceiling fixed with screws as per manufacturer instruction including preparation of surface and applying two coats of oil bound distemper over a coat of one mm thick wall care putty complete all as specified and directed.
S& F aluminium Zinc coated sheet of trapezoidal profile provided with PUF panels with 50 mm thick Puff sandwiched between top and bottom 0.5 TCT colour coated corrugated sheets with yield strength 550 N/Sqmm complete all as per manufacturer instruction and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/valley gutters/roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as directed. (Note:- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life.)
S&F 30mm thick single piece, coloured ABC (Acrylonitrile Brutadine Styrene) coated, PUF filled door shutters with PUF (Poly Urethane Foam) insulation of minimum density 40 Kg/Cum filled in between two ABS sheets of thickness 1.2mm (min), border covered with insitu pasted ABS strips of width equal to thickness of door shutters, 1.2mm thickness, reinforced with two number 10mm CTD bars, pre-embedded with wooden blocks of suitable sizes for receiving hinges, tower / sliding bolts, towel rails, handles etc, with/without embossed pattern complete all as specified and as directed.
S&F aluminium alloy, anodised, sliding door bolt, 250 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed.
S&F butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin,anodised, 125 mm long , type B-21 complete all as specified and as directed.
S&F extruded aluminium alloy handles, fabricated type, anodised, size of handle 150mm long complete all as specified and as directed.
M&L for 6 mm thick epoxy polyurethane flooring comprising of 2 mm epoxy based coloured flooring over 4 mm thick moisture barrier including making good to existing disturbed surfaces, joint cutting and filling work complete all as specified here-in-under:- A. Substrate preparation: Preparing the dry concrete surface using proper scarification equipment to remove any loose material, contamination such as oil and grease, mortar and splashes, laitance or curing compound residues to provide a sound/ gripping surface. Any traces of oil and grease shall be removed by grinding/ scarification. Any patch of area where repairing needs to be done shall be finished with epoxy screed. Cleaning of entire floor area shall be done by using powerful industrial vaccum cleaner. B. Epoxy based primer: Provide and apply one coat of epoxy resin based primer to the designated area @ 0.25 Kg/Sqm by brush or spray and wait to tack free condition. C. Moisture barrier screed: Provide and apply chemical and abrasion resistance epoxy resin modified cementitious screed of low VOC as an epoxy underlay of thickness 4 mm (weight nor less than 9 Kg/Sqm) on the designated area. The product shall be applied with V notch trowel and rolled by spike roller to release the entrapped air. The screed on curing @ 30 degree C shall achieve a minimum compressive strength of 70 N/Sqmm @ 7 days when tested as per BS 6319 Part-II, Flexural strength of 25 N/Sqmm when tested as per BS 6319 Part-III and Tensile strength of 12 N/Sqmm when tested as per BS 6319 Part-VII. D. Epoxy polyurethane topping: Provide and apply polyurethane self levelling flooring (epoxy, coloured heavy duty) as a floor topping at a thickness of 2 mm on the designated area. The product should be applied with V notch trowel and rolled by spike roller to release the entrapped air. The screed on curing @ 30 degree C should achieve a minimum compressive strength of 65 N/Sqmm @ 7 days when tested as per BS 6319 Part-II, Flexural strength of 28 N/Sqmm when tested as per BS 6319 Part-III and Tensile strength of 15 N/Sqmm when tested as per BS 6319 Part-VII. (Note: Work shall be got executed by authorised applicator as approved by E-in-C's Branch.)
M & L for hard core of gauge n. exc. 63mm, with broken stone or boulders, depasited, spread and leveled in layer n.exc 15 cm thick, wasted androlled/ rammed to a true surface complete all as specified and as directed.
M&L for factory made 100mm thick machine pressed precast cement concrete coloured interlocking paver blocks of Grade M-50 conforming to IS 15658-2006 of shape and size as directed, with grey cement and pigment laid over & including 100 mm thick sand cushioning, joints of blocks filled with dry sand and compacted with mechanical vibrator, complete all as specified and directed.
M&L for walling of random rubble uncoursed , well bonded stone massonary bedded and solidly hearted built in cement mortar 1:6, complete all as specified and as directed.
M&L for PCC (1:2:4) type B-0 (using 12.5mm graded stone aggregate), cast in situ, in benching, coping and the like etc including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
Extra over lime or sand stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surface n. exc. 40 mm to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses, complete all as specified and as directed.
M&L for raised pointing to random or polygonal rubble, uncoursed or brought upto courses, in cement mortar 1:4 complete all as specified and as directed.
M&L for pre-cast cement contrete 1:3:6 type C-1 using 20mm graded stone aggregate as in bond stone/ and set in cement mortar 1:4 complete icluding necessary form work complete all as specified and as directed.
S&F PVC (SWR) pipes 110 mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floor complete all as specified and directed.
M&L for broken stone or boulders, hand packing (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level complete all as specified and directed.
E/M PORTION
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, FLP fittings etc, removing serviceable materials to store and making good disturbed surfaces of walls, floors, etc.as per exsiting complete all as specified and directed.
Disconnecting the incoming and outgoing electrical connections and taking down carefully by unscrewing unserviceable DBs (SPN/TPN) any type/ any size complete from walls/ boards etc. complete all as specified and directed.
M & L for point wiring with 1.5 Sqmm FRLSH & PVC insulated unsheathed single core multi stranded copper conductor concealed type 1100 volt grade drawn in and including non-metalic PVC rigid conduit of minimum 20mm medium grade size for one light/ fan point point controlled by one switch including one 1.5 Sqmm PVC insulated unsheathed copper conductor for earth continuity conductor and connected to earth dolly and to be terminated to new sunken /pressed flush metal boxes of thickness 1.2mm covered with 3mm thick hylam sheet as per requirement at site for mounting switches, sockets, fan regulators etc including testing on completion including making good the disturbed surface with cement work with white washing/ colour washing / distempering to match the surface complete all as specified and as directed. (Note: Cost of metal flush box, cover plate and making good the surfaces shall be included in the item.)
All as per Srl Item No. 31.00 here-in-before but for one 6 pin multipurpose 5 Amp socket outlet indipendent complete.
All as per Srl Item No. 31.00 here-in-before but for one 15 Amp switch socket outlet independent, using 2.5 Sqmm FRLSH & PVC insulated unsheathed single core multi stranded copper conductor cable and one 2.5 Sqmm FRLSH & PVC insulated unsheathed copper conductor for earth continuity conductor for one 3 pin 5/15 Amp switch socket outlet independent complete.
M&L for flame proof point wiring complete with PVC insulated unsheathed FRLS-H multistranded copper conductor cable conforming to IS : 694 of size 1.5 Sqmm two single core drawn through in and including seamless ERW steel concealed conduit pipe 20mm/25mm dia heavy duty ISI Marked complete with one run of PVC insulated FRLS-H multistranded copper conductor cable 1.5 Sq mm single core green colour earth wire and connecting to earth dolly incl colour coding of cable shall be for phase, neutral and earth wire as specified in MES SSR Part I with provision of sunken galvanized iron not less than 1.2 mm thick sheet pressed terminal boxes concealed on wall, with 3 mm thick laminated sheet top cover ISI marked, as per requirement at site for mounting switches, sockets, fan regulators etc for One light/fan point controlled by one one way flame proof switch including testing on completion including making good the disturbed surface with cement work with white washing/ colour washing / distempering to match the surface complete all as specified and as directed. (Note: Cost of metal flush box, cover plate and making good the surfaces shall be included in the item.)
S & F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
S & F flame proof LED light fitting 2 x 16 Watt flame proof, CMRI certified, recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with and including three core flexible copper conductor cable of suitable size complete all as specified and directed.
S & F Switch piano flush type 6 Amps single pole one way, 230 volts AC including connection complete all as specified and as directed.
S & F Switch socket combination, flush type, suitable for 2/3 pin, 6 Amp including connection complete all as specified and as directed.
S & F Switch socket combination, 2 in 1, multipurpose, suitable for 6 pin, 6 Amp and 16 Amp flush type including connection complete all as specified and as directed.
S & F for polycarbonate isolated body ceiling rose surface type bakelite 65x50mm three terminal including connection complete all as specified and as directed.
S & F lamp holder insulated body with back plate for Angle holder including connection complete all as specified and as directed.
S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and directed.
S & F LED light fittings 1x 18W, 220V, AC decorative box type with driver, holder, including LED tube light connecting up with flexible 3 core flexible copper conductor cable of suitable size from ceiling rose complete all as specified.
S & F factory made sheet metal enclosure double door designed SPN 8 Way DB, made of sheet steel phosphatised, powder painted with 200 Amps rated copper busbar, grouted/ fixed flush in wall with and including suitable flat iron complete with, neutral link, dinrail suitable for mountaning MCB’s complete all as specified and as directed. (Note:- MCBs shall be measured and paid separately)
S&F MCB single pole of capacity 6 to 32 amps, C-curve, 10 KA breaking capacity and making connection with copper lugs complete all as specified and directed.
S & F MCB single pole and neutral of capacity 32 amps, C-curve, 10 KA breaking capacity and making connection with copper lugs complete all as specified and directed.
M&L for sub main wiring with two run single core 4.0 sqmm FRLS, ISI marked, PVC insulated multistranded, unsheathed copper conductor cable, in surface/recessed as required and one run single core unsheathed FRLS, ISI marked, PVC insulated multistranded copper conductor cable of size 4.0 sqmm green colour as earth wire, drawn through and including PVC heavy duty casing caping 20mm/ 25mm width complete with all accessories including taking down old unserviceable sub main wiring and making good the disturb surface with cement work with white washing/ colour washing / distempering to match the surface complete all as specified and as directed. (Note: Three runs of 4.0 sqmm cable and one run of PVC conduit shall be measured as one length).
S & F Exhaust fan, made of sturdy Engineering plastic complete with louvers shutter, 230 Volt, 50 Hz, 1200 RPM, copper winding of sweep 250 mm with and including louvers shutter, connecting up with and including three core flexible copper wire of suitable size from ceiling rose to exhaust fan complete all as specified and directed.
Taking down existing ceiling fan 1200/1400mm sweep dia, deposition in MES store and refixing the same in position including connection, after repair/renovation of the bldg complete all as specified and directed..
Supply, installation, commissioning and testing of commercial Air curtain unit for prevention of dust and conditioned air losses, three phase 440 V, 50Hz, made out of MS/CRCA sheet of minimum thickness 18 gauge finished with two coats of red oxide primer and final coat of synthetic enamel paint (oven baked) with MS -CRC 18 gauge square perforated suction grills, Aluminium alloy fans and single phase electric motor, nozzle etc, complete with fittings and accessories so as to produce 1- 1.5m/sec air velocity at floor level for door opening 64 inch x 90 inch complete all as specified and directed.
S & F LED street light fitting as a building security light 25W, with minimum 100 lumens per watt, AC 120-300 Volt operating range, 50 Hz, CRI more than 70, IP-65 degree of protection including including one 25 watt LED lamp, GI brackets made of 40mm bore medium grade GI pipe, 1.20 m long, bent to shape suitable for direct fixing on walls complete all as specified and directed.
Taking down old unserviceable LT under ground cable of any size and removing from site of work complete all as directed.
Supply, fixing/ laying, testing, connecting and commissioning of LT under ground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) of size 120 Sqmm, 3.5 Core as per IS:7098 (Pt-I), with multistranded aluminium conductor, 1100 Volts grade laid in trenches/ on wall/ poles/ ducts/ inside protection pipe including cable glands, lugs and MS saddle clips of suitable size (where ever cable laid on ceilings / walls without cable duct) complete all as specified and as directed. (Note: Excavation & earth work, cable cover, sand cushioning shall be measured and paid seperately under respective items.)
All as per Srl Item No. 53.00 here-in-before but for 185 Sqmm 3.5 core complete.
M & L for Cable jointing kit for 1.1 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 sqmm, complete all as specified and directed.
M & L for Cable jointing kit for 1.1 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm, complete all as specified and directed.
Excavation in trenches not. exc 1.5 m wide and not exceeding 1.5 m in depth for foundation etc drain, manhole, laying of cable not exceeding 10 Sqm on plan and not exceeding 1.5mtr in depth and getting out in soft/loose soil complete all as specified and directed. (Note: During excavation work, no mechanical excavator is permitted at site, excavation through manually only.)
Returning, filling in trenches including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil, complete, all as specified and directed.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level, not exceeding 1.5 metre above the starting point complete all as specified and directed.
Supply and spreading dry river sand in trenches for protection of underground electric cable, spread in uniform 23 cm thickness and punned down gently to 18 cm complete all as specified and as directed. (Note: Punned thickness shall be measured and paid.)
Supply and laying well burnt Sub Class 'B' locally available best quality laid in trenches perpendicular to UG cable above sand cushioning for cable protection complete all as specified and directed.
M&L for Earthing complete with GI earth plate elecrode of size 600 mm × 600 mm × 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to GI earth strip 32 mm x 6 mm by means of bolts, nuts, check nuts and washers of brass or HS steel all as shown in electrical plate No. 3 connected to earthing test point and and necessary excavation and earth work pre-cast RCC(1:2:4) type B-1 pit cover 50mm thick, reinforced with 8mm dia TMT bars @100 mm /C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab and PCC(1:2:4) type B-1 concrete pit and angle iron frame and opening arrangement ) incl providing charcoal or coke and common salt in alternate layer of 15 cm compacted thickness all around the earth electrode with funnel and 20 mm bore galvanized iron watering pipe (medium grade) wire mesh, copper lugs, complete in all respect, protected by 40 mm bore (light grade) galvanized iron pipe up to earthing test point as directed, incl disposal of surplus soil to a distance not exc 50 mtr and necessary testing on completion including dismantling of old unserviceable earthing complete all as specified and directed. [NOTE : (a) Proper earthing pit should be provided with pit cover. (b) Excavation/earthwork is deemed to be included in the quoted rate. (c) In case of desired test result is not achieved, the earthing shall be redone with out any extra cost to the department.]
M & L for Earthing complete with copper earth plate electrode 600mm x 600mm x 3.15mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to copper earth strip 20 x 3 mm earth lead by means of bolts, nuts, check nuts and washers of copper, all as shown in electrical plate No 3 of SSR Part-I including necessary excavation and earth work PCC 1:3:6 type C-1 with 50mm thick pre-cast RCC (1:2:4) type B-1 cover slab (reinforced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle of 10mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15cm compacted thickness all around earth electrode, with funnel and 20mm bore galvanised iron watering pipe (light grade), wire mesh, aluminum lugs, complete in all respect, Coper earth strip protected by 32mm bore (medium grade) galvanised iron pipe and other end connected with main switch board or earthing test point as directed, including disposal of surplus soil to a distance not exceeding 50 mtrs and necessary testing on completion including dismantling of old unserviceable earthing complete all as specified and directed. [NOTE : (a) Proper earthing pit should be provided with pit cover. (b) Excavation/earthwork is deemed to be included in the quoted rate. (c) In case of desired test result is not achieved, the earthing shall be redone with out any extra cost to the department.]
M & L for Chemical Earthing complete with copper earth plate electrode 900mm x 600mm x 5mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to copper earth strip 32x6 mm earth lead by means of bolts, nuts, check nuts and washers of copper, all as shown in electrical plate No 3 of SSR Part I including necessary excavation and earth work PCC 1:3:6 type C-1 with 50mm thick pre-cast RCC (1:2:4) type B-1 cover slab (reinforced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle of 10mm dia round bar), including providing hygroscopic chemical material of good conductivity all around earth electrode, with funnel and 20mm bore galvanised iron watering pipe (light grade), wire mesh, aluminum lugs, complete in all respect, Copper earth strip protected by 40mm bore (medium grade) galvanised iron pipe and other end connected with main switch board or Earthing test point as directed, including disposal of surplus soil to a distance not exceeding 50 mtrs and necessary testing on completion including dismantling of old unserviceable earthing complete all as specified and directed. [NOTE : (a) Proper earthing pit should be provided with pit cover. (b) Excavation/earthwork is deemed to be included in the quoted rate. (c) In case of desired test result is not achieved, the earthing shall be redone with out any extra cost to the department.]
Taking down old distribution transformer step down 125 KVA including disconnecting all connections and shifting to MES Store yard complete all as specified and directed.
Supply, install, testing and commissioning of outdoor type transformer step down, copper wounded having primary side for HT Three Phase 11 KV & secondary for 3 phase 433 Volts, 4 wire 50 Hz of capacity 160 KVA as per IS-1180 Part-I (as per latest amendmend) Level-II with and including the following specification:- (i) No load voltage ratio-11KV/ 0.433 KV, (ii) Nos of phase-three. (iii) Type of cooling- ONAN, (iv) Frequency-50 Hz, (v) Vector group-DYN 11, (vi) Two earthing terminals for body earthing and two additional for neutral, (vii) Oil level gauge indicating oil level with minimum and maximum indication, (viii) Lifting lugs rollers and MS terminal Box on both HT and LT side, (ix) Rating and terminal marking plates, (x) Dehydrating breathing device which would not permit ingress of moisture, rain water and insects (xi) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug, (xii) Thermometer pocket, (xiii) Oil filling hole( 1-1/4" Nominal size thread) with cover (transformer wih conservator), (xiv) Connection-Delta/Star, (xv) Temperature rise in oil-40 deg celcius, (xvi) Temperature rise in windings- 45 deg Celcius, (xvii) Material winding-Copper wound, (xviii) High voltage/low voltage with cable box, (xix) Service-Outoor type, (xx) Neutral- Internally conneted with earthing lead and bush, (xxi) On load tap changar (+5% to -5% in steps of -15% with 7 position), (xxii) First filling of transformer oil upto recommended level. NOTE:- 1. The contractor/manufacturer shall furnish original certificate (paid voucher and test certificate) of the CRGO manufacturer. 2. The manufacturer /contractor shall furnish the diameter of LV and HV copper winding and its total resistance. The stray losses shall be specified in percentage terms. 3. The contractor shall get the approval of AGE (I) for the make of the transformer they plan to procure. 4. Prior to manufacturing the general arrangement drawing design details of the transformer shall be got approved by AGE(I). 5. Transformer shall be dispatch only after inspection clearance by inspecting officer. 6. Necessary foundation with plinth shall be provided as per manufacturer's recommendation, quoted rate shall be deemed to be included accordingly in srl item No 67 herein after.
M&L for construction of brick masonary Platform of size 3m x 3m x 1.5 m for mounting base of Transformer complete with XPM fencing weight not less than 4Kg/Sqm and angle iron 50x50x6mm for support, gate with locking arrangement, PCC flooring 1:2:4 (type D-2 using 40mm graded stone aggregate) including excavation, earthwork, formwork, painting with two coats of cement based paint over a coat of primer over platform faces, two coat of synthetic enamelled paint over one coat of red oxide primer on steel surfaces complete all as specified and directed.
Supply, instalation, commissioning and testing of factory made type, dust and vermin proof, totally enclosed control panel outdoor type CPRI approved, fully comparted type, fabricated out of 3.15mm thick CRCA sheet, duly painted with epoxy powder coating with 10 tank process, IP-65 Protection, with provn of front double door shutter with locking arrangement mounted on MS angle iron frame of 50x50x5 mm and legs grouted on PCC foundation with PCC (1:2:4) type B1 (leg of LT panel be embedded not less than 15cm in PCC), foundation shall be 30cm below the ground and 20cm above the GL, including dismantling of existing unserviceable LT panel complete all as directed and comprising of the followings :- (i) Aluminium Bus bar TPN 500 Amp of suitable length and section covered with coloured heat shrinkable anti track insulation tape of finished thickness not more than 1mm and fixed on epoxy base post insulator of both dia and height not less than 40mm - 01 Set. (ii) MCCB 250 Amp Ics 36 KA , 4 Pole, 415 V, 50 Hz, with adjustable thermal and fixed magnetic release - 1 No. (incoming) (iii) MCCB 160 Amp, Ics 35 KA, 3 pole, 415 V, 50 Hz with adjustable thermal and fixed magnetic release- 2 Nos. (outgoing) (iv) MCCB 63 Amp, Ics 16 KA, 3 pole, 415 V, 50 Hz with adjustable thermal and fixed magnetic release- 1 No. (outgoing) (v) Indicator lamp RYB- 1 Set. (vi) Multifunction meter digital compatible to measure voltage, current, PF, frequency with 3 lines display LCD in 96x96 sqmm flush mounted case, accuracy class 1.0- 01 No. (vii) On load changeover switch 4 pole 300 amps 415 V AC, 50 Hz- 01 Nos. viii) Danger notice plate riveted on the outer body 440 volt. [Note:- (a) All existing and new connections of incoming/outgoing cables shall be done through appropriate size of copper thimbles. (b) Drawing, circuit diagram and all materials/instruments for panel shall be approved by AGE(I) before fabrication. (c) PCC foundation shall deemed to be included in the unit rate.]
Supply, instalation, commissioning and testing of factory made type, dust and vermin proof, totally enclosed control panel indoor type CPRI approved, fully comparted type, fabricated out of 3.15mm thick CRCA sheet, duly painted with epoxy powder coating with 10 tank process, IP-65 Protection, with provn of front double door shutter with locking arrangement mounted on MS angle iron frame of 50x50x5 mm and legs grouted on PCC foundation with PCC (1:2:4) type B1 (leg of LT panel be embedded not less than 15cm in PCC), foundation shall be 30cm below the ground and 20cm above the GL, including dismantling of existing unserviceable LT panel complete all as directed and comprising of the followings :- (i) Aluminium Bus bar TPN 300 Amp of suitable length and section covered with coloured heat shrinkable anti track insulation tape of finished thickness not more than 1mm and fixed on epoxy base post insulator of both dia and height not less than 40mm - 01 Set. (ii) MCCB 160 Amp Ics 36 KA , 4 Pole, 415 V, 50 Hz, with adjustable thermal and fixed magnetic release - 1 No. (incoming) (iii) MCCB 80 Amp, Ics 16 KA, 3 pole, 415 V, 50 Hz with adjustable thermal and fixed magnetic release- 3 Nos. (outgoing) (iv) MCCB 63 Amp, Ics 16 KA, 3 pole, 415 V, 50 Hz with adjustable thermal and fixed magnetic release- 1 No. (outgoing) (v) Indicator lamp RYB- 1 Set. (vi) Multifunction meter digital compatible to measure voltage, current, PF, frequency with 3 lines display LCD in 96 x96 sqmm flush mounted case, accuracy class 1.0 - 01 No. (vii) Danger notice plate riveted on the outer body 440 volt. [Note:- (a) All existing and new connections of incoming/outgoing cables shall be done through appropriate size of copper thimbles. (b) Drawing, circuit diagram and all materials/instruments for panel shall be approved by AGE(I) before fabrication. (c) PCC foundation shall deemed to be included in the unit rate.]
Dismantling existing old vintage central AC plant of capacity 10 TR x 3 by removing complete ducting from false ceiling, AHU, compressors, chiller, condensors, cooling tower, connected motor pump sets, connected pipeline and shifting to MES Store yard complete all as specified and directed
Design, Supply, installation, testing and commissioning of Air conditioning system to maintain the design condition 22 ± 3º C DB and 55 + 5% RH, consisting to 03 Nos 15 TR each scroll water cooled water machines (2 Workinh + 1 Standby), 03 Nos condenser water pumpset (2W + 1S), 03 Nos chilled water pumpset (2W + 1S), 03 Nos cooling air tower of suitable for 30 TR chiller, strip heater of 40 KW, air handiling units, chilled and condensing water piping, air distrubition system, Electric Control panels, cabling, wiring, control wiring and earthing including building management system for automatic operation of AC plant to maintain tempereture and humidity, complete all as specified and directed as per description (Design Data Sheet) of item indicated as per Annexure 'A' .
Serial Item No. 71.00 (Contd....) Note 1 :- (a) Contractors/ Bidders are advised to visit the site to check the desired inside design conditions carefully and submit the bid only after ascertaining the capacity of the AC plant required to acheive the inside design conditions. (b) Contractor / Bidder should submit complete design for the Central AC Plant including duct layout and comprising of heat load calculations, working drawings of complete AC plant supported with design/ calculations of each component duly vetted by IIT/NIT through GE/CWE for the approval of Accepting Officer before execution of the work. (c) Contractor/ Bidder shall be responsible for perfomance guarantee of complete AC plant to achieve the inside design conditions round the clock throughout the year with overall COP of the system not less than 03. (d) Design, Supply, installation, testing and commissioning of Air conditioning system shall be undertaken through Manufacturers/ Specialist Firm. Note 2 :- Rates quoted by the contractor shall be complete finished work including cost of all labour, material, scafffolding,, finishing as required with tools, plants, cartage, lift, taxes, tollage, octroi, royalties etc. All works shall be executed as per drawings and instructions of site-in-charge and shall include the supply and installation at site of all the equipment, ancillary materials as specified and all such items what-so-ever which may be required to fulfil the intent and purpose as laid down in the drawings. All materials shall be as per ISI specification and with IS certification marked wherever applicable. The material shall be duly approved by site-in-charge before incorporation in the actual work. Note 3 :- Rates quoted by the contractor shall deemed to be include for Manning & Operation of AC Plant during the period of seasonal tests.
S&F of Copper air termination rod 16mm dia 1.2 Mtr long with accessories to fix at the existing position, top of roof level including dismantling existing air termination rod from lightning arrestor mast complete all as specified and directed.
S & F Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screw complete all as specified and directed.
S&F Earth continuity conductor or main earthing lead made of Copper strip of size 32 mm x 6 mm as roof conductor/down conductor above ground level/ burried in ground fixed with saddles (made of Porcelain / PVC ) and screws at a distance of 30 cm complete all as specified and directed.
NOTE: Schedule of cedit amount of Rs 97,360.00 shall be deducted from the total quoted amount of BOQ.
RS COOLING APPLIANCES
M/s JK Jangid and Company
M.P. Khaitan
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .