Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹22.4 L+₹2.6 L (13.1%)Rejected-Finance | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹22.4 L+₹2.7 L (13.4%)Rejected-Finance NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹22.5 L+₹2.8 L (14.0%)Rejected-Finance BARIYAWAN BARIYAWAN BARIYAWAN BARIYAWAN AMBEDKAR NAGAR UTTAR PRADESH 224210 | AMBEDKAR NAGAR | UTTAR PRADESH | 224210 | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹23.0 L+₹3.2 L (16.4%)Rejected-Finance 137 D6 ARAVALI HEIGHTS DPL DWARIKADISH ROAD DHARUHERA REWARI HARYANA 123106 | REWARI | HARYANA | 123106 | L5 | Rejected-Finance Not lowest |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
21 Mar 2024, 6:00 pmClosed
GE South Delhi Cantt-10
GE South Delhi Cantt-10
PROVN OF DEFICIENT GEYSERS AGAINST INITIAL DEFICIENCY, 238 NOs EXHAUST FANS AT JCOs/ORs MD ACCN AT DUNDAHERA MIL STN AND ADDN/ALTN TO INTERNAL WIRING AT VRC UNDER AGE E/M OF GE (SOUTH) DELHI CANTT-10
2024_MES_643642_1
GE/DS-106/2023-24
Open Tender
Civil Works
Item Rate
120 days
GE South Delhi Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹68,000
Yes
15 Apr 2024
22 Feb 2024
23 Mar 2024
22 Feb 2024
21 Mar 2024
7 Mar 2024
Amount
Taking down carefully the old U/S Aluminium point wiring (light, fan, socket or power) complete fitting such as switches, ceiling roses, pendants, sockets, regulators, etc and making good disturbed surfaces of walls including necessary touch up with the adjoining surface of disturbed area ie with OBD/colour wash/white wash as the existing finish complete all as sepcified and as directed.
M&L for point wiring complete, stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in but with through suitable concealed PVC conduit and including replacement of modular sunken pressed steel terminal boxes 2mm thick of required size and modular white cover plate with all accessories including 1.5 sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete and making good to disturbed surface of walls including necessary touch up with adjoining surface of disturbed area i.e with OBD/colour work/white wash as existing finishes complete all as sepcified and as directed. Notes :- 1. The Rate is inclusive cutting/chasing and making good distrubed surface with CM 1:3 and same surface finishes with the adjoining surface of distribed area with ODB/colour wash/white wash complete. 2. At roof slab where there is burnt/blockage in the existing conduit wiring will be done through PVC conduit and rate are inclusive in above quoted item.
All as per Srl item No.2 above, but One Light/Fan/Exhaust/Bell point/security light controlled by one way switch.
All as per Srl item No.2 above, but One 3 pin socket outlet 5 amps on same board.
All as per Srl item No.2 above, but One 3 pin socket outlet 5 amps point independent board with cable 1.5 Sqmm for main current and 1.5 sqmm as earth wire as power point.
All as per Srl item No.2 above, but One 3 pin socket outlet, 15 amps on independent board with cable 2.5 Sqmm for main current and 2.5 sqmm as earth wire as power point.
All as per Srl item No.2 above, but One 3 pin socket outlet, 15 amps on independent board with cable 4 Sqmm for main current and 4 sqmm as earth wire as power point.
S&F Switch modular type, 1Module, 6 Amps one way complete all as sepcified and as directed.
S&F Socket outlet modular type 2M, 2/3 pin, 6 Amp complete all as sepcified and as directed.
S&F Switch modular type 1M, 16 Amp complete all as sepcified and as directed. Note:- Electrical switch for Geyser of 16 Amp shall be provided on main switch board of bath and socket outlet shell be provided near the Geyser will be masured as 16 Amp Point wiring against Srl item No.2 (d)
S&F socket outlet modular type 2M, 2/3 pin, 16 Amp complete all as sepcified and as directed.
S&F electric bell ding dong AC, 230 volts single phase complete all as sepcified and as directed.
S&F Bell push modular type 1M 5/6 Amp complete all as sepcified and as directed.
S&F in repairs wall mounted LED Integrated Batten 20 Watt - 4Ft White, indoor decorative PVC extruded LED battern-Integrated complete all as sepcified and as directed.
S&F in repairs wall mounted LED Integrated Batten 10 Watt-2 Ft White, indoor decorative PVC extruded LED battern-integrated type complete all as sepcified and as directed.
S&F in repairs battan of holder PVC insulated body complete all as sepcified and as directed.
S&F in repairs LED lamp 12 Watt LED Bulb complete all as sepcified and as directed.
S&F in repairs Electronic fan regulator, modular type 2M, 4 steps complete all as sepcified and as directed.
Taking down of ceiling fan and keeping in safe custody and refixing it back after completion of point wiring complete all as sepcified and as directed.
S&F BLDC (Brushless DIrect Current) Ceiling fan, 1200mm suitable for regulator, not less than 350 RPM, not less than Air delivery 215 cum/minute, voltage 220V, hihg air follow with silence operation, having full copper winding & ribbed blade 3 Nos A/M blades. The BLDC motor fan shall have 100% rust free blade. The fan shall be BEE 5 star rating and compliant with IS-374 and making necessary electric connection of suitable PVC copper wire from ceiling rose to ceiling fan all as specified and directed by Engr in charge including taking down old ceiling fan and depositing to MES store yard complete all as sepcified and as directed.
S&F in repairs wall mounting 12 Watt LED decorative wall light fixture made up of Polycarbonate, with suitable with all connection complete all as sepcified and as directed.
S&F in repairs 10 LED bulk head in engineering plastic housing with clear prismatic diffuser, 10W WHITE including all accessories connecting up twin core flexible copper conductor cable complete all as sepcified and as directed.
Taking down of exhaust fan and keeping in safe custody and refixing it back after completion of point wiring complete all as sepcified and as directed.
S&F ceiling rose surfaces bakelite minimum size 65x50mm with two/three terminals complete all as sepcified and as directed.
S&F water storage heater 25 ltr capacity, BEE 5 Star rated, vertical type, Glass line, AC, vertical type, AC, Single Phase electric, 230 Volt, complete with heating element 2 KW, thermostat, 3 core lead, Plug top, safety valve, including electric and water connection with suitable nut, bolts & washers and making good to disturbed surface complete all as sepcified and as directed.
S&F PVC connection with brass nipple 15mm x 600mm long with ISI marked, stainless steel, suitable for hot and cold water of 25 ltrs capacity of geyser as hot and cold water connection complete all as sepcified and as directed.
Taking down Electric/Electronic KWH meter and refixing it back after Submain wiring and connecting up complete all as sepcified and as directed.
S&F in repairs sheet metal enclosure of size 300 x 250 x 150 mm suitable for mounting Single phase electric meter fabricated from 2mm thick CRCA sheet with anti corrosive dust and vermin proof complete all as sepcified and as directed. Note:- The meter cover shall have a fully transparent window. The window shall be of transparent, high grade UV stabilized engineering plastic for easy reading of all the displayed values/parameters and observation of operation indicator. The window shall preferably be an integral part of meter cover.
S&F in repairs MCB DB SPN 12 Way with metal double door, (IP43 Protection) flush mounting epoxy powder control having 100 Apms rated bus bar complete all as sepcified and as directed.
S&F in repairs MCB SPN 'B' curve 40 to 63 Amps 240 Volts, 10 kA including electrical connection with suitable size of thimble complete all as sepcified and as directed.
S&F in repairs MCB SP 'B' curve 06 to 32 Amps 240 Volts 10 kA including electrical connection with suitable size of thimble complete all as sepcified and as directed.
S&F in repairs submain wiring of two runs of 6 Sqmm size for main cable and one run of 6 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked , drawn PVC existing conceiled conduit complete all as sepcified and as directed. Note:- The rates are inclusive of Cutting/chasing and making good to disturbed surface with CM 1:3 and same surface finishes with the adjoining surface of disturbed area with OBD/Colour wash /white wash complete.
M&L for opening of hole through out the wall as suitable for exhaust fan of size upto and including 300mm sweep and fixing of nut-bolts with 4" anchor fastner of suitable size and making food the disturbed surface and all as per site requirement complete all as sepcified and as directed. Note:- The rates are inclusive in respect of under this item as above hole opening civil work with MS faster bolt of 8mm dia and 100mm (minimum) long for fixing of exhaust fan and MS fastner clamps strip 38 mm wide and 5mm thick (min) to hold exhaust fan.
S&F metal body exhaust fan 300mm sweep, 230 Volts with louver and copper wound including opening of hall and necessary electric connection with appropriate size of PVC copper wire from ceiling rose/switch board to exhaust fan including fixing of nut-bolts of suitable size and making good the disturbed surface of wall with OBD/White wash to match with complete all as sepcified and as directed.
M&L for point wiring complete, stranded copper conductor 4 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in but with through suitable surface PVC conduit/casing caping and including replacement of modular sunken pressed steel terminal boxes 2mm thick of required size and modular white cover plate with all accessories including 4 sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete and making good to disturbed surface of walls including necessary touch up with adjoining surface of disturbed area i.e with OBD/colour work/white wash as existing finishes complete all as sepcified and as directed. Notes:- 1. The Rate is inclusive cutting/chasing and making good distrubed surface with CM 1:3 and same surface finishes with the adjoining surface of distribed area with ODB/colour wash/white wash complete. 2. One 3 pin socket outlet, 15 amps on independent board with cable 4 Sqmm for main current and 4 sqmm as earth wire as power point.
S&F 15mm bore pipe medium grade galvlanised iron pipe with all fitting fixed in wall/floor and making connections and making good the disturbed surface to match with the existing specifications complete all as sepcified and as directed.
S&F bib tap 15mm bore of cast coper alloy CP fancy type scrwed to iron pipe and fixed complete all as sepcified and as directed.
S&F stopcock concealed Angle type 15mm dia cast copper alloy CP fancy type screwed for iron pipe and fixed complete all as sepcified and as directed.
M&L for point wiring with PVC insulated unsheathed multi stranded FRLS type copper conductor cable of size 1.5 Sqmm 1100 V grade including one run of PVC insulated unsheathed multi stranded FRLS type copper conductor cable of size 1.5 sqmm as earth continuity conductor connected to common earth dolly in and including PVC concealed conduit of suitable dia medium grade ISI marked and its accessories including provn of MS new factory made sunken box of suitable size for housing the Piano switches, sockets, fan regulators. One Exhaust/Ceiling fan point controlled by one no, one way 5 Amp switch.
S&F 6 Amp rating single pole piano type flush mounted switch 230/250 volts grade one way complete all as sepcified and as directed.
S&F Metal exhaust fan 250 mm size suitable for 240V, 50 Hz single phase AC supply and necessary electrical connection from ceiling rose to fan connecter with three core sheathed wire of required length including ceiling rose complete all as specified and directed.
Note :- The contract sum shall be after deducting the amount of credit shown in Sch of Credit of this tender
Vijeta Solutions
Chaudhary Constructions
m/s VK construction company
Shrikanth Solutions
PARADISE INFRA POWER COMPANY
MOHIT ENTERPRISES
J V ENGINEERS / JAI SINGH
M/s Durga Traders
M/s Navansh Engineers & Consultants
Grid Infratech Pvt Ltd
M/S.M.S.Devi.Const.Co
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .