| 1 | L1₹1.6 CrAccepted-AOC NO 75 76 DHANALAKSHMI NAGAR EXTENSION GUNDUSALAI CUDDALORE 607001 | CUDDALORE | CUDDALORE | TAMIL NADU | 607001 | ₹1.6 Cr | L1 | Accepted-AOC Agreement accepted |
| 2 | L2₹1.7 Cr+₹1.6 L (0.99%)Rejected-Finance | ₹1.7 Cr+₹1.6 L (0.99%) | L2 | Rejected-Finance SECOND LOWEST TENDERER L2 |
| 3 | L3₹1.7 Cr+₹3.4 L (2.08%)Rejected-Finance | ₹1.7 Cr+₹3.4 L (2.08%) | L3 | Rejected-Finance THIRD LOWEST TENDERER L3 |
| Sl No | Description | Qty | Unit | MUTHUSWAMY CONSTRUCTION L1 | Meenu Industries PVT.LTD. L2 | VIJAYASANKAR R L3 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling, clearing away and carefully stacking materials useful for re-use Removal of cut stone slabs & RCC cover slabs etc., Complete and as directed by the departmental officers. | 204 | m2 | 570 ₹1,16,280 Lowest | 576 ₹1,17,504 | 582 ₹1,18,728 |
| 2.00 | Dismantling, clearing away and carefully stacking materials useful for re-use of Floor finish and dadooing walls in cement mortar with mosaic tiles / glazed tiles / cuddapah slabs etc., Complete and as directed by the departmental officers. | 1,055.45 | m2 | 68 ₹71,770.6 Lowest | 69 ₹72,826.05 | 69 ₹72,826.05 |
| 3.00 | Dismantling and Clean Removing of Ceiling and Wall Plastering carefully stacking materials within compound places etc.complete complying with standard specification. | 1,535 | m2 | 10 ₹15,350 Lowest | 11 ₹16,885 | 12 ₹18,420 |
| 4.00 | Dismantling, clearing away and carefully stacking materials useful for re-use of Pressed tiles etc., Complete and as directed by the departmental officers. | 329 | m2 | 50 ₹16,450 Lowest | 52 ₹17,108 | 52 ₹17,108 |
| 5.00 | Repairs of Doors & windows such as shakes, hookes, mending eyes etc.complete complying with standard specification. | 629 | m2 | 170 ₹1,06,930 Lowest | 173 ₹1,08,817 | 174 ₹1,09,446 |
| 6.00 | Paving the floor with best approved quality fine polished Kota stone slabs of size 600 x 600 of 18 / 20mm with machine cut edges and matching marble slab not less than 100mm width other than Adanga Marbles as border laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., | 204 | m2 | 1,600 ₹3,26,400 Lowest | 1,615 ₹3,29,460 | 1,631 ₹3,32,724 |
| 7.00 | Dadooing walls with following best approved quality, white / colour glazed tiles of following sizes set in Cement Mortar 1:2 (One Cement and Two crushed stone sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers. | 816.15 | m2 | 1,700 ₹13,87,455 Lowest | 1,710 ₹13,95,616.5 | 1,727 ₹14,09,491.05 |
| 8.00 | Flooring with ceramic tiles of following size and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. etc., complete complying with standard specification and as directed by the departmental officers. | 240 | m2 | 1,225 ₹2,94,000 Lowest | 1,236 ₹2,96,640 | 1,248 ₹2,99,520 |
| 9.00Brick work in following Cement Mortar using best quality Burnt Clay Brick of size 9" x 4 3/8" x 2 3/4" with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge. | ||||||
| 9.01 | b) Ground Floor | 37 | m3 | 8,000 ₹2,96,000 Lowest | 8,078 ₹2,98,886 | 8,155 ₹3,01,735 |
Tender Value
₹1.6 Cr
EMD Value
₹89,100
Closing Date
28 Aug 2025, 3:00 pmClosed
Superintending Engineer
Office of the Superintending Engineer, PWD., Building Construction and Maintenance Circle, Thanjavur-1
Renovation of UG Boys and Girls Hostel Building in Government Cuddalore Medical college at Chidambaram
2025_PWD_595992_1
28-12-2025-2026
Open Tender
Civil Works - Buildings
Lump-sum
120 days
Chidambaram
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹89,100
10 Dec 2025
22 Aug 2025
29 Aug 2025
22 Aug 2025
28 Aug 2025
22 Aug 2025
Amount
Dismantling, clearing away and carefully stacking materials useful for re-use Removal of cut stone slabs & RCC cover slabs etc., Complete and as directed by the departmental officers.
Dismantling, clearing away and carefully stacking materials useful for re-use of Floor finish and dadooing walls in cement mortar with mosaic tiles / glazed tiles / cuddapah slabs etc., Complete and as directed by the departmental officers.
Dismantling and Clean Removing of Ceiling and Wall Plastering carefully stacking materials within compound places etc.complete complying with standard specification.
Dismantling, clearing away and carefully stacking materials useful for re-use of Pressed tiles etc., Complete and as directed by the departmental officers.
Repairs of Doors & windows such as shakes, hookes, mending eyes etc.complete complying with standard specification.
Paving the floor with best approved quality fine polished Kota stone slabs of size 600 x 600 of 18 / 20mm with machine cut edges and matching marble slab not less than 100mm width other than Adanga Marbles as border laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc.,
Dadooing walls with following best approved quality, white / colour glazed tiles of following sizes set in Cement Mortar 1:2 (One Cement and Two crushed stone sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.
Flooring with ceramic tiles of following size and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. etc., complete complying with standard specification and as directed by the departmental officers.
Brick work in following Cement Mortar using best quality Burnt Clay Brick of size 9" x 4 3/8" x 2 3/4" with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge.
b) Ground Floor
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers.
Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
Providing and Applying high strength, hybrid polyurethane Waterproofing coating which is two component, cold applied, water based acrylic and UV resistant water proofing treatment to the Existing Roof screed surface applied @ 1.6 L/m2 in 3 coats to achieve 1mm DFT, having tensile strength with 45 gsm glass fibre mesh 10N/mm2, Elongation >200%, confirming to ASTM D 2370; Abrasion resistance 15mg confirming to ASTM D 4060 and Crack bridging ability up to 3mm, including surface preparation, ensure surface in SSD condition for first coat and spreading 45 gsm glass fibre mesh of 2.5mm x 2.5mm sanwiched between the first and second coat completely as per specification. The finished cost to include surface preparation, making coving as Junction, treatment of cracks completely as per specification
Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise and similar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
Supplying and fixing fine polished cuddapah slab of following thickness for cup-board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as direct. 38 / 40mm thick
Supplying , fixing and roofing with colour galvalume sheet of 0.47mm thick with all necessary accessories such as J/V bolt and nuts of suitable length with suitable bitumen washers complete complying with standard specification and as directed by the departmental officers.
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Painting the wall two coats with approved weather proof Exterior Emulsion paint over one primer coat of over cement plastered wall surface ect., complete complying with standard specification.
Painting old wood works such as doors, windows, ventilators, window bars, balustrades etc., with two coat of best approved first quality and colour of synthetic enamel paint over the existing priming coat in all floors excluding cost of priming coat etc., complete
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete
Supplying and fixing solid core flush shutter of following type with thickness with necessary T.W. internal lipping alround conforming to IS 2202-1(1999) including cost of wind appliances and furniture fittings such as 3 Nos SS 304 Grade Butt Hinges of size (125mm x 30mm) , 2 Nos .300x12mm aluminium tower bolt 1 No. 200x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 2 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete complying with standard specification and as directed by the departmental officers - Single leaf.
Supplying and fixing 30mm thick solid core PVC door shutter with PVC frame of size 50x45mm with suitable rebate for housing the shutter (Conforming to IS 4020 with updated amendment) consisting of frame made out of MS tubes 19 gauge thickness and size of 19 x 19mm for styles and 15x15mm for top and bottom rails. M.S. frame shall be covered with 5mm thick heat moulded PVC ‘C' channel of size 30 x 50mm forming styles, and 75x50mm for top rail, lock rail and bottom rail on either side and 10mm (5mm x 2) thick 20mm wide cross PVC sheet as gap insert for top rail, bottom rail. Paneling of 5mm thick PVC sheet bearing on either side and join together other side etc. An additional 5mm thick PVC strip of 20mm width is to be stack and the interior side of the ‘C' channel using PVC sealant adhesive including cost of all furniture fittings such as aluminium aldrop of size 250x16mm - 1No., aluminium tower bolt 250x12mm - 1No. aluminium D type handle 200mm etc. complete, as per direction of Engineer in charge and drawing. (Sliding arrangements with roller)
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
Supplying and fixing mild steel grills for windows, ventilators, etc., including priming coat. complete complying with standard specification and as directed by the departmental officers.
Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers.
Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with crushed stone sandcushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers.
Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm "P" or "S" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications.
Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification
Supplying, laying and jointing UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.
20mm dia
25mm dia
32mm dia
Supplying UPVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements
20mm dia Elbow
20mm dia Tee
20mm dia Coupling
15x20mm dia Reducer
25mm dia Elbow
25mm dia Tee
25mm dia Coupling
20x25mm dia Reducer
25x32mm dia Reducer
Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work.
a) 20mm dia
b) 25mm dia
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level
a) 75mm dia
b) 110mm dia
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification.
160mm dia
Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).
110mm PVC Elbow
110mm PVC Tee
110mm PVC Bend
Construction of INSPECTION CHAMBER following clear sizes including earth work excavation, CC 1:5:10 of 10 cm thick and brick work in Cement Mortar 1:5 [One cement and Five sand] using best quality of second class Table Mould Bricks of size 9" x 43/8" x 23/4" with Plastering with Cement Mortar 1:3 [One Cement and Three Plastering Sand] 12 mm thick to inner and outer sides and wearing coat 1:3:6 [One Cement, Three crushed stone sand and Six Aggregate] 15 cm thick and covered with precast slab 5 cm thick etc., complete complying as directed by the departmental officers as per standard specification.
ADD GST 18%
Meenu Industries PVT.LTD. (BID ID -1442051)
VIJAYASANKAR R (BID ID -1441573)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .