Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.2 LAccepted-AOC 76 CRIPER ROAD KONNAGAR HOOGHLY | KONNAGAR | HOOGHLY | WEST BENGAL | L1 | Accepted-AOC LOWEST RATE | |
| 2 | L2₹36.7 L+₹2.5 L (7.27%)Rejected-Finance 17 1 ABHOY HALDER LANE KOLKATA | KOLKATA | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹37.2 L+₹2.9 L (8.61%)Rejected-Finance PATRA MARKET KRISHANAGAR NADIA | KRISHANAGAR | NADIA | L3 | Rejected-Finance HIGH RATE |
Tender Value
Refer Docs
EMD Value
₹69,000
Closing Date
22 Mar 2023, 4:00 pmClosed
Executive Engineer, EMD, PHE Dte
P-16, India Exch. Place Extn., CIT Annexd Bldg.
Round the clock Operation Guarding of Pumping machinery, 200 KVA Boosting 415V Transformers, lighting arrangement and other allied works at INTAKE PUMPING STATION under Surface Water Based WS Scheme, Northern Sector, Part-I Kaliganj, Dist.- Nadia.
2023_PHED_480871_1
WBPHED/EE/EMD/NIET/41/2022-23
Open Tender
Miscellaneous Works
Item Rate
30 days
P-16, India Exch. Place Extn., CIT Annexd Bldg.
Please refer Tender documents.
5 documents required · 5 mandatory
₹69,000
Yes
31 Mar 2023
27 Feb 2023
24 Mar 2023
27 Feb 2023
22 Mar 2023
27 Feb 2023
Amount
Day to day Operation & guarding of installed pumping machinery, internal & external electrification, 200 KVA Boosting Transformers, pump , Incoming cable from WTP to Intake, LT control/Distribution panel, MCC panel, 7.5KVA DG set, periodical inspection and cheaking of other equipments like Starter, Electrical gadgets, valves, actuators compound lighting arrangement etc. by engaging skilled, semi-skilled and un-skilled workers round the clock including up-keepment of entire installation and sweeping charges at Intake Pumping Station as per direction of the EIC. Period: 366 days. Major Electro Mechanical machineries at the installation:- a) Centrifugal pump motor set - 45 KW X 3 nos. (2W + 1S) b) External and Internal lighting arrangement c) 7.5 KVA DG Set
Routine and periodical inspection for Pumps, Motors, valves with Actuators, Flow/ Level/ Pressure instruments, Gauges, Lightings, hoisting arrangements, Exhaust Fans & LT Panel Boards, Cable ends, capacitor, boosting Transformers, earthing system in compliance to the guide line as mentioned in the terms and conditions. The periodical chart in tabular format as per direction of the EIC and in comply to the specification enclosed herewith for the check points scheduled should be furnished to the Department for the period 366 days.
Cleaning of contacts twice in a month by CRC 226 SPRAY in the LT Panel Board, cleaning of all Terminal Sockets, Coils once in a month in presence of Electrical Supervisor / Electrician and to be recorded in the Log Book with date including supply of new gland packing, fuses, cotton waste, indicating lamps etc. 12 months.
Servicing, testing and calibration complete with submission of report (specify of set point) in compliance with the guide line as per specification for the ACBS, ammeters, voltmeters checking complete, wiring, testing CTs, PTs, Relay testing and calibration, insulation check once in half yearly (Twice in a year) = 366 days.
Consumption of diesel for 7.5KVA capacity DG set @ 2.5 ltr./hr. including all carriage & storage for 366 days X 2hr. run/day i.e. 730 hours [Measurement must be as per actual running Hr/log book.]
Consumption of Mobil oil including all carriage & storage for the 7.5KVA DG set for 366days x 2hrs. run/day. [Measurement must be as per actual running Hr/log book.]
Add: GST @ 18%
Add: LW Cess @ 1%
ORIENTAL ENGINEERING CO.
Tarun Kumar Bhattacharya
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .