Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹74.3 LAccepted-AOC NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹75.7 L+₹1.4 L (1.83%)Rejected-Finance P O P S MISSAMARI DIST SONITPUR ASSAM 784506 | SONITPUR | ASSAM | 784506 | L2 | Rejected-Finance HIGH BID VALUE | |
| 3 | Rejected-Technical VILL LAKHOPARA PO GARUBANDHA DISTT SONITPUR ASSAM 784506 | SONITPUR | ASSAM | 784506 | - | Rejected-Technical DOES NOT BELONG TO APPROPRIATE CATEGORY. |
Tender Value
₹80 L
EMD Value
₹1.4 L
Closing Date
28 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COL GANESH ZAPE
HQ CWE TENGA, PIN - 900194 C/O 99 APO
PROVISION OF POWER SUPPLY AND EXTERNAL WATER SUPPLY UNDER GE MISSAMARI
2023_MES_582390_1
8337/E8
Open Tender
Civil Works
Item Rate
270 days
GE MISSAMARI
C b(ii)
8 documents required · 8 mandatory
₹1,000
GE MISSAMARI
₹1.4 L
Yes
26 Apr 2023
22 Feb 2023
4 Apr 2023
22 Feb 2023
28 Mar 2023
15 Mar 2023
Amount
Supply, lay and testing cable XLPE insulated screened PVC bedded, galvnized steel strip or wire armoured , electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts (earth) grade, of size 95 sq mm 3 core complete all as specified and directed
Supply and fixing Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed.
Excavation in trenches not exc 1.5 metre wide and not exc 1.5 metre depth for laying of UG cable / pole etc getting out including forming bottom surface to required level and gradient in soft/loose soil complete all as specified and as directed.
Returning and filling in excavated soil including spreading leveling, watering, well ramming in layers not exc 25 Cm thick complete all as specified and directed
Removing of excavated materials not exceeding 50 metre and depositing where directed by Engr in Charge at a level not exceeding 1.5 metre above the starting point complete all as specified and directed
Supply and laying well burnt Bricks , locally available best quality (sub class "B" bricks) laid in trenches perpandicular to U/G cable for cable protection complete all as specified.
M & L Clean dry river sand in trenches/ducts for cushioning to cable, 8 cm in depth before laying the cable and 15 cm in depth after laying the cable complete all as specified.
Supply and laying un-reinforce precast concrete cable cover, class HV type-1 with peak, size 300 mm 180 mmx 40mm for protection of HT cable complete all as specified and as directed.
M & L for PCC (1:4:8) type D-2 (using 40 mm aggregate) as in foundation for pole etc.complete all as specified and as directed.
M & L for PCC (1:2:4) type B-1 (using 20 mm aggregate) as in coping of pole etc including form work & finishing the surfaces even & smooth with out using extra cement complete all as specified and as directed.
S&F switch air brake gang operated for 11 KV grade, Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps, mechanically operated machanism from Ground Level consisting of Operating Rod of GI Pipe, 25mm bore (dia) "light grade" of suitable length worked from ground level and with locking arrangement mild steel flat iron clamp 50x6mm complete all as specified and as directed Make:- Jaipuria/ Rashtriya/ABB/Packtil.
Supply and fix expulsion fuse, Triple pole, channel type/drop out type suitable as per site reqmt with working pressure 11 KV grade of capacity upto 200 Amps compete all as specified and as directed. Make:- Jaipuria/ Rashtriya/ABB/Packtil.
S&F Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for working pressure 11000 volts and connecting to earth with GI 32x6mm strip, completed with all as specified and directed.Make:- Lamco/ Oblum/Jaipuria.
M&L Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one alvanised iron nut, 50mm height, 65mm dia for 550 volts grade complete all as specified and as directed. Make:- Jaipuria/ Rashtriya/ABB.
S&F Disc type insulator porcelain, vitreous,145mm high and 255mm dia ball and socket Type white , brown or green insulator single Disc Assembly for tension with Tension Clamps for conductors working pressure 11000 Volts, complete all as specified and as directed.
Supply, errection and fixing steel tubular swaged poles complete with cast iron base plate , finial taper plug bolt nuts and washer 11.0 Mtr long type 410 SP -55 single swan neck including foundation, coping and painting with two coats of Aluminium paint over a coat of red oxide primer (Externally from top of coping) including writing MES Pole No with synthetic Enemal Paint complete all as specified and as directed. Note : Excavation, earthwork, PCC foundation and coping shall be measured and paid seperately. Make:- NTL/ calcutta poles/Nezon.
Supply and fixing GI Pipe light grade of size 50 mm bore with all fittings for passing of cables fixed to pole / wall / laid under floor or roads including all fixing accessories complete for protection of cable all as specified and directed . Make:- sail/ Hindustan/Nezon/JIndal.
Supply and fixing GI Pipe light grade of size 100 mm bore with all fittings for passing of cables fixed to pole / wall / laid under floor or roads including all fixing accessories complete for protection of cable all as specified and directed . Make:- sail/ Hindustan/Nezon/JIndal.
M & L for earthing complete with GI Earth Electrode 600mmX600mmx6mm thick buried directly in ground vertically to a depth not less 2.25 mtr below ground level with top edge of earth plate a depth not less than 1.50 mtr below Normal Ground level connection to GI strip 32x6 mm drawn through and including galvanised iron protection pipe 40 mm bore (dia)Light grade up to height of the transformer foundation where foundation situated by means of bolt Nuts check Nuts and washers etc earth plate surroumded by a packed thickness of charcoal or coke dust mixed with common salt in alternate layers of not exc 150 mm thick PCC pit in cement concreate 1:3:6 ( 20mm graded aggreage ) Pre cast RCC 1:2:4 (20 MM graded aggreagate Cover slab 350X350X50MM thick reinforce with including 8mm dia TMT Bars@10 CM centre to centre both ways GI Wire Mess,Funnel with GI watering pipe 20 MM bore diaMedium grade necessary excavation in soft loose soil returning fillingin and revoal of surplus soil upto a distance of 50 Mtr and all as shown in electrical plate No 3 of MES schedule Part -I and testing on completion complete all as specified and as directed. Note:- 02 Nos for Transformer Body and 02 Nos for main LT panel.
M & L for earthing complete with GI Earth Electrode 600mmX600mmx6mm thick buried directly in ground vertically to a depth not less 2.25 mtr below ground level with top edge of earth plate a depth not less than 1.50 mtr below Normal Ground level connection to galvanised iron as earth lead 4mm drawn through and including galvanised iron protection pipe 15 mm bore (dia)Light grade up to 1 .0 Mtr above the ground level of HT pole foundation where PCC pole situated by means of bolt Nuts check Nuts and washers etc earth plate surroumded by a packed thickness of charcoal or coke dust mixed with common salt in alternate layers of not exc 150 mm thick PCC pit in cement concreate 1:3:6 ( 20mm graded aggreage ) Pre cast RCC 1:2:4 (20 MM graded aggreagate Cover slab 350X350X50MM thick reinforce with including 8mm dia TMT Bars@10 CM centre to centre both ways GI Wire Mess,Funnel with GI watering pipe 20 MM bore diaMedium grade necessary excavation in soft loose soil returning fillingin and revoal of surplus soil upto a distance of 50 Mtr and all as shown in electrical plate No 3 of MES schedule Part -I and testing on completion complete all as specified and as directed.
M & L for earthing complete with copper Earth Electrode 600mmX600mmx6mm thick buried directly in ground vertically to a depth not less 2.25 mtr below ground level with top edge of earth plate a depth not less than 1.50 mtr below Normal Ground level connection to copper strip 20x3 mm drawn through and including galvanised iron protection pipe 40 mm bore (dia)Light grade up to height of the transformer foundation where foundation situated by means of bolt Nuts check Nuts and washers etc earth plate surroumded by a packed thickness of charcoal or coke dust mixed with common salt in alternate layers of not exc 150 mm thick PCC pit in cement concreate 1:3:6 ( 20mm graded aggreage ) Pre cast RCC 1:2:4 (20 MM graded aggreagate Cover slab 350X350X50MM thick reinforce with including 8mm dia TMT Bars@10 CM centre to centre both ways GI Wire Mess,Funnel with GI watering pipe 20 MM bore diaMedium grade necessary excavation in soft loose soil returning fillingin and revoal of surplus soil upto a distance of 50 Mtr and all as shown in electrical plate No 3 of MES schedule Part -I and testing on completion complete all as specified and as directed.
M &L Test point terminal block made of gun metal or phosphorus bronze size 75X75X25mm dnilled and screwed including 3 Nos 8 mm dia 25mm long hex head screw complete all as specified and directed by Engr-in-charge
Supply and fix Earthing continuity conductor or Main earthing lead fixed to wall or batten or reccessor chasses or buried in ground or drawn in conduit/pipe or fixed to poleor any other indicated situation for loop GI of size 32MMx6MM connectected to test point complete all as specified
Supply and lay cable XLPE Insulated screened Meter PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core. Make:- polycab/Havells/KEI
All as per Item Ser No. 24 above, but 25 sqmm x 4 core
All as per Item Ser No. 24 above, but 25 sqmm x 2 core
Supply, install, test and commission step down transformer, outdoor type, plinth mounted HT 11 KV, 3 phase 433 volts, 4 wire, 50 Hz, delta/star connected, vector group DYN -11 double copper wound, ONAN, manual type off load tap changing facility on HT side to vary secondary voltage from minus 7.5% to plus 7.5% in steps of 2.5 %, continuous rating, level-02 of capacity 100 KVA incl bushing on HT end cable box on LT side. The transformer shall be complete with all standard fittings and accessories, gauges, first fill of transformer oil, etc, and conforming to IS 1180 Part-1:2014 duly mounted on plinth and all as specified and as directed. (a) Oil conservator with filling hole, cap and drain plug (b) Silica gel breather with oil seal and first fills of dehydrating agent (c) Adequate Nos of thermometer pockets incl one No for accomodating bulb type thermometer (d) Drain cum bottom filter valve (e) Top filter valve (f) Prisomatic oil level gauge (g) Inspection cover (h) Cover fitting lugs (j) Jacking and fitting lugs (k) Separate neutral bushing brought out for earthing on LV side (l) Earthing terminal NNote: PCC platform / plinth for placing transformer is not included in the quoted rate and will be measured and paid under seperate item.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure.
Supply and lay PVC Insulated PVC sheathed LT cable unarmoured with stranded copper conductor of size 1.5 Sqmm x3 core drawn into steel pole for connection or security/street light fitting from junction box all as directed and specified
Supply and fixing security LED Luminaire 45 watt including GI brackets of suitable size with 1.5 Sqmm 3 core Cu wire for connection of security light all accessories and foundation etc Make:- polycab/Havells/KEI.
Supply and fixing Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-22 (9.0 metres) long)
S&F Aluminium Conductor Steel Reinforced (ACSR) (sizes as ordered) with permissible Sags and providing Jumper, etc., fixing on Electric Poles and binding to Insulators with Aluminium Binding Wire as in OH Conductors including stringing, tightening, etc., complete all as specified and as directed. NOTE : Cost of Binding Wire is deemed to be included in the quoted Unit Rate.
S&F Cradles, hexagonal/rectangular fabricated with Galvanised Steel Wire with 4.00mm dia including binding with Aluminium Binding Wire, complete all as specified and as directed. NOTE : Cost of Binding Wire is deemed to be included in the Quoted Unit Rate.
M&L Cross-arms, Bracings, Supports, Clamps and Back Plates fabricated from Structural Steel Sections including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ directed and inclusive of one coat of Aluminium Primer one Under Coat and One Finishing Coat of Aluminium Paint, complete all as specified and as directed.
Provn of chain link / Barbed wire fencing with I post as per TD drg No.CESZ/2019/TD-48 complete all as specified and as directed.
Supply, testing and commissioning as in replacement of Single phase 2 wire 240 V 10-60A Class 1.0 Prepaid Meter as per IS 15884, frequency 50 Hz, Complying to IP51 with LCD Display ,KWH LED, encrypted STS based token system with Home display Unit complete alongwith parallel consumer interface unit and soft token transfer device at house , with facility of meter to generate ABC code(Authenticated Billing Code) for monthly Energy usage bill generation ,numeric keypad for token entry with LED for credit status indication, push button for scroll and having features for load disconnection in case the credit limit become zero or increase of load then permissible limit ,reconnection and disconnection of load, buzzer at Consumer interface unit to give alarm in case of low credit and overloading and data download port for last 25 days (minimum) , Relays provided for phase and neutral disconnection, programmable friendly hours/day, holidays, slab/time -of-day tariff structure,optional consumer interface unit (CIU) available with USB dongle token carrier for recharging,temper event and load survey for last 45 days with all standard anti temper features all as specified and directed. Model :- Taurus, Make L&T Meters, and equivalent in ABB,Secure and Genus
S&F Polycarbonate Meter enclosure including Steel wire locking arrangement for Single phase prepaid meter as mentioned in item No 37 complete all as specified and directed.
Transaction/Vending charges inclusive of customer service by OEM, programming ,software update etc for prepaid meter complete all as specified.
M &L for anti-climbing device comprising 2.24mm dia galvanised steel 2 strand barbed wire with 2.24 mm dia barbs wrapped spirally round poles, to a length of 5 to 1.0 mtr clamed and properly secured or as ordered clamps measured separately. complete all as specified and as directed.
S&F Pre cast Reinforced Cement concrete 1:2:4 (20 MM graded aggregate) Type B-1 of size (.5MX.05X.1.0M) cable Route indicator including embossing Dangers/11KV cables/MES on both sides and painted Letter with approved colour burried in ground for a depth of 45 Cm including necessary Earth work complete all as specified and as directed.
Surface dressing in soft loose soil n exc 15 cm deep and getting out complete all as specified and as directed.
M&L for brick work with burnt old size bricks built in cement mortar 1:6 straight or curved on plan exceeding 6mtr mean radius and all as directed.
M&L rendering 15mm thick on other than fair faces of brick or concrete Surfaces in cement mortar 1:6 finished even and smooth complete all as specified and as directed.
M&L three coat of white wash on wall surface including preparation of surface complete all as specified and as directed.
Excavation in trenches exc. 1.5 metre and not exc. 3 metre deep and not exc 1.5 metre wide for laying of pole and getting out in soft/loose soil complete all as specified and as directed
S&F Cable End jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm Complete all as specified and directed.
Supply, install, test and commission step down transformer, outdoor type, plinth mounted HT 11 KV, 3 phase 433 volts, 4 wire, 50 Hz, delta/star connected, vector group DYN -11 double copper wound, ONAN, manual type off load tap changing facility on HT side to vary secondary voltage from minus 7.5% to plus 7.5% in steps of 2.5 %, continuous rating of capacity 160 KVA and of Level - 2 energy efficiency incl bushing on HT end cable box on LT side. The transformer shall be complete with all standard fittings and accessories, gauges, first fill of transformer oil, etc, and conforming to IS 1180 Part-1:2014 duly mounted on plinth and all as specified and as directed.Make- Voltamp/ Transformer and rectifier/ (a) Oil conservator with filling hole, cap and drain plug (b) Silica gel breather with oil seal and first fills of dehydrating agent (c) Adequate Nos of thermometer pockets incl one No for accomodating bulb type thermometer (d) Drain cum bottom filter valve (e) Top filter valve (f) Prisomatic oil level gauge (g) Inspection cover (h) Cover fitting lugs (j) Jacking and fitting lugs (k) Separate neutral bushing brought out for earthing on LV side (l) Earthing terminal Note :- (a) Cost of platform will be measured at appropriate items.
Supply & Laying, testing & commissioning of LT UG cable of size 3.5 core x 300 Sqmm, XLPE sheathed PVC insulated,screened PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade, laid in trenches/ surface of wall/ in GI pipe along with pole for connection to OH lines,including brass cable glands,clamps,etc including removal of existing unsv cable and making good damaged surfaces complete all as specified. ( From Transformer to LT Panel )
Supply and fixing GI Pipe light grade of size 80 mm bore with all fittings for passing of cables fixed to pole / wall / laid under floor or roads including all fixing accessories complete for protection of cable all as specified and directed .
Boring holes horizontally under Road without damaging the surface of Road (minimum 1.0 METRE below the Road Surface with the help of GI Tubing not exc. 80mm bore (dia) for passing of UG Cable, complete all as specified and as directed. Note : GI Pipe laid will be measured and paid separately under appropriate Item.
S&F Pre-cast Reinforced Cement Concrete 1:2:4 (20mm graded aggregate) Type B-1 of size (0.5M X 0.05MX1.0M) Cable Route Indicator including embossing 'DANGER/11KV CABLE/MES' on both sides and painted Letters with approved Colour, burried in ground for a depth of 45 Cm including necessary Earth Work, complete all as specified and as directed.
M &L for danger notice plate of 1.6mm thick mild steel sheet, vitereous enamelled white, with letters figures and conventional skull and bones in single red colour and fixed with MS clamps bolts and nuts of approved size, for HT, 25X20 cm.
Supply ,install , testing and commissioning of servo controlled voltage stabilizer (Conforming to BIS 9815 ,Part-1:1994),150 KVA, Three Phase ,50 Hz , Naturally Oil cooled, indoor, unbalanced type, copper wound , metallic body duly powder coated with lifting hooks two nos , digital display type ,relay free smooth and silent operation with 1st filling of transformer oil upto level having following specification :- (a) Input Voltage 360V-480 V , (b) Output Voltage stabilized by any designed /desired voltage 415 V +/- 1% (c) Rated Frequency 50 Hz (d) No distortion in waveform (e) Response time not to exceed 10 mili per seconds. (f) Sensitivity ( +/- )1% (g) Rate of correction 8 Volts/Second for single Phase and 20 V/Seconds for phase to phase. (h) Efficiency more than 95% (i) Type of load : three phase ,unbalanced type. (j) Digital display Voltmeter/Ammeter Protection:- 1 . Overload /Short Circuit Protections 2. High/Low Voltage Cut off 3. By pass arrangement in case of emergency. 4. Single Phase Sequence change protection. Make:- Volina / Voltamp / AE/ Andrew yule
Supply & Laying, testing & commissioning of LT UG cable of size 5 core x 16 Sqmm, XLPE sheathed PVC insulated,screened PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded Copper conductor 1100 volts grade, laid in trenches/ surface of wall/ in GI pipe along with pole for connection to OH lines,including brass cable glands,clamps,etc including removal of existing unsv cable and making good damaged surfaces complete all as specified. ( From Transformer to LT Panel )
Materials and labour for RCC M-25 (Design Mix) (using 20mm graded stone aggregate) as in foundation, footing of column, plinth beam, etc. complete all as specified and as directed.
Materials and labour for RCC M-25 (Design Mix) (using 20mm graded stone aggregate) as in column, pillars, piers, posts and struts complete all as specified and as directed.
Materials and labour for RCC M-25 (Design Mix) (using 20mm graded stone aggregate) as in beams, cantilevers, lintel over 1.5m span or bands complete all as specified and as directed.
Materials and labour for RCC M-25 (Design Mix) (using 20mm graded stone aggregate) as in chajjas and similar works complete all as specified and as directed.
Materials and labour for RCC M-25 (Design Mix) (using 20mm graded stone aggregate) as in slab supported on walls beams and column in floors, roofs landing,deck slabs and in shelves complete all as specified and as directed.
Material & labour for formwork to sides and suffit of suspended slabs such as roof slab, floor slabs, etc. with rough finished square/rectangular surfaces of concrete complete all as specified and as directed.
Material & labour for formwork to sides of concrete of foundation, footings, plinth beam, etc. with rough finished square/rectangular surfaces of concrete complete all as specified and as directed.
Material & labour for formwork to sides of concrete of columns, pillars, posts with rough finished square/rectangular surfaces of concrete complete all as specified and as directed.
Material & labour for formwork to sides and soffits of concrete of beam, lintels, cantilevers etc. with rough finished square/rectangular surfaces of concrete complete all as specified and as directed.
Material & labour for formwork to as in chajjas with rough finished square/rectangular surfaces of concrete complete all as specified and as directed.
Supply and fixing mild steel TMT bar 10mm dia and over, cut to length , bend to shape required, including cranking, bending, hooking end etc. including MS wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
Supply and fixing mild steel TMT bar 6mm to 8mm dia, cut to length , bend to shape required, including cranking, bending, hooking end etc. including MS wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
Supply and fixing mild steel TMT bar 5mm dia and over upto and including 10mm dia in stirrups, binders, cut to length, bend to shape required, including cranking, bending, hooking end etc. including MS wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
M&L Sand filling under floors or in foundations including watering and consolidation
Material and labour for 100mm thick PCC 1:4:8 type D2 as in sub base of floor complete all as specified and as directed.
M&L for filling of soil of approved quality with sand mixed at a ratio of( 1:1 )and spreading in layers n exc 30 cm thick;watering,ramming/rolling and finishing to required size,shape n exc 1.5 m high from base .
Material and labour for 25mm thick PCC 12:4 type B2 as in sub base of floor/Floor complete all as specified and as directed.
M& L for machine cut kota stone slab flooring 20-25mm thick over 20mm thick screed bed in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified as directed.
M& L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over 15mm thick cement screed in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified as directed.
M&L 05mm thick cement plaster on ceiling surfaces without using extra cement finishing fair and even in CM 1:3 including necessary scaffolding complete all as directed.
M & L for 20 mm thick plastering in two layers, 10 mm each in cement mortar 1:4 with water proofing compound (@ 2% by weight of cement or as per manufacture's instructions) on brick/stone walls or concrete surfaces finished even and fair ( upto any height) for external surfaces complete all as specified and directed. Note : Water Proofing compound shall be measured and paid separetly as "Supply only".
Supply only liquid water proofing compound
Preparation of new plastered surfaces and applying three coats of white wash on ceiling all as specified and directed.
M&L applying two coat of cement base paint over a coat of cement base primer on newly plastered surfaces of walls including preparation of surfaces.
M&L Hardcore of gaugeof broken stone n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered andnrammed to a true surface
M&L for 75 mm thick PCC type C2 (1:3:6) using 20mm graded crushed stone aggregate as in plinth protection , finishing cement concrete surfaces even & smooth without using extra cement.
Material and labour for 100mm thick PCC 1:3:6 type C2 as in foot path complete all as specified and as directed.
M&L Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing com• pound, Grade ‘A’
S& F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints including additional rebate for second shutter.
Supply and fixing 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides
Materials and labour for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in cills,copings, kneelers, apex stones,bed plates etc complete all as specified and as directed.
Supply and fixing mild steel hold fast for door/ window complete all as specified and as directed.
Supply and fixing 100mm long Mild steel butt hinges complete all as specified and as directed.
Supply and fixing small articles with 2nd class hard wood complete all as specified and as directed.
Supply and fix 50mm long Mild steel butt hinges complete all as specified and as directed.
Supply and fixing 150mm long aluminium bow handle complete all as specified and as directed.
Supply and fixing 150mm long aluminium tower bolt complete all as specified and as directed.
Supply and fixing 250mm long aluminium sliding door bolt complete all as specified and as directed.
Supply and fixing mild steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete all as specified and as directed.
S& F 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq m in each pane complete all as specified and directed.
S & F Mild steel 1.0mm thick rolling shutters, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; eerected in position as indicated, complete; push pull or manual type complete all as specified and directed
Material and labour for 2 coats of synthetic enamel paint over a coat of pink primer on wooden surface of doors including preparation of surfaces complete all as specified and as directed.
Material and labour for 2 coats of synthetic enamel paint over a coat of pink primer on wooden surface of treating small articles such as stop, covers, gully gratings, holdfasts, ends of posts, backs of chowkats, etc.,area n exc 0.1 sq. m each, including preparation of surfaces complete all as specified and as directed.
Material and labour for 2 coats of black japan paint on steel surface of treating Small articles such as knobs, fasteners, holdfast similar arti-cles, when unconne-cted with other pain-ting or when painted in a different tint complete all as specified and directed
M&L for preparation of new surfaces of steel or iron surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
M&L Framed Work such as Ornamental Grills, Gratings, etc. with ends of Bars shouldered and/or riveted, or forged into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Framework of Water Tanks and Similar Work, conforming to Fe-290, Gde-E-165, complete all as speci-fied and as directed.
Supply, laying, jointing & testing of Ductile Iron (DI) Pressure 150mm bore (dia) with Spigot & Socket Ends, Centrifugally Cast (Spun) with Cement Mortar Lining in Inner Side confirming to IS : 8392 /2000 in standard length for classification K-7 and other relevant standards and Metallic Zinc Coating followed by a finishing layer of Epoxy Paint in outer side, suitable for Push-on Joint (Rubber Gasket Joint) in any length and laid in Trenches, complete all as specified and as directed by Engr-in charge. Note- Excavation,DI Specials and rubber gasket joint shall be measured and paid separately .
Supply, laying, jointing & testing of Ductile Iron (DI) Pressure 100mm bore (dia) with Spigot & Socket Ends, Centrifugally Cast (Spun) with Cement Mortar Lining in Inner Side confirming to IS : 8392 /2000 in standard length for classification K-7 and other relevant standards and Metallic Zinc Coating followed by a finishing layer of Epoxy Paint in outer side, suitable for Push-on Joint (Rubber Gasket Joint) in any length and laid in Trenches, complete all as specified and as directed by Engr-in charge. Note- Excavation,DI Specials and rubber gasket joint shall be measured and paid separately .
Supply Laying and Fix 3 layered (outer green coloured UV stabalized , middle black coloured UV stabalized, and inner most layer white coloured with antimicrobial property) fusion welded PP-R ( Polypropyelene random copolymer) Pipes 90 mm dia outer dia ISI marked and fittings including plain PPR Fittings and brass threaded PPR fittings and cramping , cutting and making good to the damages of grade PN -16 SDR 7.4 including laid in trenches or surface , fixing on wall with clamps at 1.00m spacing including testing of joints complete all as specified and as directed by Engr-in-charge. Note - Excavation shall be measured and paid separately
Supply Laying and Fix 3 layered (outer green coloured UV stabalized , middle black coloured UV stabalized, and inner most layer white coloured with antimicrobial property) fusion welded PP-R ( Polypropyelene random copolymer) Pipes 63 mm dia outer dia ISI marked and fittings including plain PPR Fittings and brass threaded PPR fittings and cramping , cutting and making good to the damages of grade PN -16 SDR 7.4 including laid in trenches or surface , fixing on wall with clamps at 1.00m spacing including testing of joints complete all as specified and as directed by Engr-in-charge. Note - Excavation shall be measured and paid separately
Supply Laying and Fix 3 layered (outer green coloured UV stabalized , middle black coloured UV stabalized, and inner most layer white coloured with antimicrobial property) fusion welded PP-R ( Polypropyelene random copolymer) Pipes 50 mm dia outer dia ISI marked and fittings including plain PPR Fittings and brass threaded PPR fittings and cramping , cutting and making good to the damages of grade PN -16 SDR 7.4 including laid in trenches or surface , fixing on wall with clamps at 1.00m spacing including testing of joints complete all as specified and as directed by Engr-in-charge. Note - Excavation shall be measured and paid separately
Supply Laying and Fix 3 layered (outer green coloured UV stabalized , middle black coloured UV stabalized, and inner most layer white coloured with antimicrobial property) fusion welded PP-R ( Polypropyelene random copolymer) Pipes 40 mm dia outer dia ISI marked and fittings including plain PPR Fittings and brass threaded PPR fittings and cramping , cutting and making good to the damages of grade PN -16 SDR 7.4 including laid in trenches or surface , fixing on wall with clamps at 1.00m spacing including testing of joints complete all as specified and as directed by Engr-in-charge. Note - Excavation shall be measured and paid separately
Supply Laying and Fix 3 layered (outer green coloured UV stabalized , middle black coloured UV stabalized, and inner most layer white coloured with antimicrobial property) fusion welded PP-R ( Polypropyelene random copolymer) Pipes 32 mm dia outer dia ISI marked and fittings including plain PPR Fittings and brass threaded PPR fittings and cramping , cutting and making good to the damages of grade PN -16 SDR 7.4 including laid in trenches or surface , fixing on wall with clamps at 1.00m spacing including testing of joints complete all as specified and as directed by Engr-in-charge. Note - Excavation shall be measured and paid separately
Supply Laying and Fix 3 layered (outer green coloured UV stabalized , middle black coloured UV stabalized, and inner most layer white coloured with antimicrobial property) fusion welded PP-R ( Polypropyelene random copolymer) Pipes 25 mm dia outer dia ISI marked and fittings including plain PPR Fittings and brass threaded PPR fittings and cramping , cutting and making good to the damages of grade PN -16 SDR 7.4 including laid in trenches or surface , fixing on wall with clamps at 1.00m spacing including testing of joints complete all as specified and as directed by Engr-in-charge. Note - Excavation shall be measured and paid separately
M&L Cast Iron Sluice Valve 150 mm bore (dia), comply with IS:14846-2000, Class PN-1.6, both Ends Flanged, having Gun Metal Working Parts, Stainless Steel Spindle with Cast Iron Hand Wheel with all necessary fixing Arrangements such as Gaskets, Mild Steel Nuts, Bolts, Washers, etc. and testing including taking down unserviceable Sluice Valve, complete all as specified and as directed by Engr-in charge.Make- Kirloskar or equivalant Make of Sant/BIR/Leader/KVMC.
M&L Cast Iron Sluice Valve 100 mm bore (dia), comply with IS:14846-2000, Class PN-1.6, both Ends Flanged, having Gun Metal Working Parts, Stainless Steel Spindle with Cast Iron Hand Wheel with all necessary fixing Arrangements such as Gaskets, Mild Steel Nuts, Bolts, Washers, etc. and testing including taking down unserviceable Sluice Valve, complete all as specified and as directed by Engr-in charge.Make- Kirloskar or equivalant Make of Sant/BIR/Leader/KVMC.
S & F PP-R Gate valve (Brass insert) 3 layered (outer green coloured UV stabalized , middle black coloured UV stabalized, and inner most layer white coloured with antimicrobial property )fusion welded PP-R ( Polypropyelene random copolymer) gate valve brass 90 mm Outer dia light weight ISI marked as per pre requirement of the site with handle screwed both ends for PP-R Pipes or for unions fixed of grade PN-25 , SDR-7.4 complete all as specified and as directed by Engr-in-charge.
S & F PP-R Gate valve (Brass insert) 3 layered (outer green coloured UV stabalized , middle black coloured UV stabalized, and inner most layer white coloured with antimicrobial property )fusion welded PP-R ( Polypropyelene random copolymer) gate valve brass 63 mm Outer dia light weight ISI marked as per pre requirement of the site with handle screwed both ends for PP-R Pipes or for unions fixed of grade PN-25 , SDR-7.4 complete all as specified and as directed by Engr-in-charge.
S & F PP-R Gate valve (Brass insert) 3 layered (outer green coloured UV stabalized , middle black coloured UV stabalized, and inner most layer white coloured with antimicrobial property )fusion welded PP-R ( Polypropyelene random copolymer) gate valve brass 50 mm Outer dia light weight ISI marked as per pre requirement of the site with handle screwed both ends for PP-R Pipes or for unions fixed of grade PN-25 , SDR-7.4 complete all as specified and asdirected by Engr-in-charge.
S & F PP-R Gate valve (Brass insert) 3 layered (outer green coloured UV stabalized , middle black coloured UV stabalized, and inner most layer white coloured with antimicrobial property )fusion welded PP-R ( Polypropyelene random copolymer) gate valve brass 40 mm Outer dia light weight ISI marked as per pre requirement of the site with handle screwed both ends for PP-R Pipes or for unions fixed of grade PN-25 , SDR-7.4 complete all as specified and asdirected by Engr-in-charge.
S & F PP-R Gate valve (Brass insert) 3 layered (outer green coloured UV stabalized , middle black coloured UV stabalized, and inner most layer white coloured with antimicrobial property )fusion welded PP-R ( Polypropyelene random copolymer) gate valve brass 32 mm Outer dia light weight ISI marked as per pre requirement of the site with handle screwed both ends for PP-R Pipes or for unions fixed of grade PN-25 , SDR-7.4 complete all as specified and as directed by Engr-in-charge.
S & F PP-R Gate valve (Brass insert) 3 layered (outer green coloured UV stabalized , middle black coloured UV stabalized, and inner most layer white coloured with antimicrobial property )fusion welded PP-R ( Polypropyelene random copolymer) gate valve brass 25 mm Outer dia light weight ISI marked as per pre requirement of the site with handle screwed both ends for PP-R Pipes or for unions fixed of grade PN-25 , SDR-7.4 complete all as specified and as directed by Engr-in-charge.
Supply and fix PVC float valve of dia 25 mm for distribution tank with tank nipple complete with all acessories complete all as specified and as directed by Engr-in-charge.
M&L construction Brick Masonary valve pit of size 900x900x900 mm ( internal dimention) one each brick thick wall in cement mortar 1:4 on 100 mm thick PCC 1:4:8 ( 40mm graded aggre-gate) in job foundation, renderring 15mm thick internally and externally upto 150mm below GL , providing 3.15 mm thich MS Sheet valve pit cover , welded with 40x5mm flat iron frame all round including provision of hinges, handle with locking arrangement and 40x40x6 mm angle iron frame fixed on top of value pit by means of hold fast 150mm long, embedd-ed in PCC 1:2:4 20 mm graded aggregate bolck of size 230x200x100mm applying two coats of anti- corrosive paint to all expossed steel surface over acoat of red oxide zinc chrome primer after preparation of surfaces and necessay earth work in soaft/ loose soil includinding demolition of unserviceable value pit, complete all as specified and as directed by Engr-In- Charge.
M & L for DI Bends tapers, Tees, pieces (Single or double branch) any Type and angle/ radius and straight connecting pieces for Pipe upto 300mm bore complete all as specified and as directed by Engr-in charge.Make- Electrosteel casting ltd or equivalant Make of Tata/Electrotherm/Jindal/Kiswok/Kejriwal
M/S RANA ENGINEERING ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .