Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Tenderer | |
| 2 | L2₹21.5 L+₹61,706 (2.96%)Rejected-Finance 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹21.7 L+₹87,031 (4.17%)Rejected-Finance RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹24.8 L+₹3.9 L (18.9%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L4 | Rejected-Finance Other than lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
7 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
REPAIR AND MAINT OF DESERT COOLERS AND COOLING APPLIANCES INSTALLED AT RRRC,RECORDS RRRRC,202 BD COY,1 AHQ SIG REGT,1 CBPO,150 TA PUNJAB,105 TA RAJ RIF,1CIU,DELHI AREA PRO UNIT,HQ DELHI AREA SIG COY,HQ DELHI AREA, COMMAND HUTS,60 INF BDE ETC
2020_MES_350560_2
GE(U)/PM/D-25/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DELHI CANTT
MES contractor enlisted under class E category c(i) having deposited standing security of Rs 50000 with department. Contractor not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹50,000
Yes
16 Sept 2020
16 Jun 2020
9 Jul 2020
16 Jun 2020
7 Jul 2020
23 Jun 2020
60 days
Amount
Material and labour for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded, unsheathed 1100 volts grade in PVC casing caping (heavy grade) of adequit size with all fittings and casing caping accessories of surface type including one run 6 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694) as earth wire including taking down old unservisible sub main wiring complete all as specified and as directed.
Material and labour for sub main wiring with two runs of single core 4 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded, unsheathed 1100 volts grade in PVC casing caping (heavy grade) of adequit size with all fittings and casing caping accessories of surface type including one run 4 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694) as earth wire including taking down old unservisible sub main wiring complete all as specified and as directed. {Notes for item No. 1 & 2 :-(i) Two runs of cable with one runs earth wire and PVC casing caping shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the casing capping. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.} (iv) (Make of cable:- RR Kabel/Finolex/ Havells/ Polycab/ KEI Industries.) (v) (Make of PVC Casing caping:- FINOLEX / ANCHOR/ KALINGA/ SUPREME/ POLYCAB.)
Disconnecting from mains and taking down for servicing of Water Cooler of Capacity 40/80, 60/120, Ltrs including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc., and keeping the Water cooler unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and installation in same location complete all as specified and as directed by Engineer-in-Charge. Note :- (i). Replacement of defective spares for making the water cooler units in satisfactory working condition will be measured & paid separately under relevant items. (ii) Transportation charge if any & labour charges for taking down old spares and fixing of new spares shall deemed to be included in quoted rate.
Supply only over load protector relay suitable for 40/80 Ltrs capacity water coolers. (Make:- Renutrol/ Sri Ram/Microtech)
Supply only thermostat suitable for 40/80/120/150 Ltr capacity water coolers. (Make :- Indfoss/ Renutrol).
Supply only condenser motor fan blade suitable for 40/80/120/150 Ltr capacity water coolers. (Make: Tipcon/ Usha/Epcos/Keltron)
Supply only PVC flexible drain Hose Pipe 40 mm. (Make:- Prayag/ Polytuff/Supreme/ Prince)
Supply only waste water tray PVC for 40/80, 60/120, 150/150 Ltr capacity water coolers. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make water cooler).
Supply only chromium plated push taps suitable for 40/80/120/150 Ltr capacity water coolers all as directed. (Make : Parryware/ Prayag/ Cera/ Essco.)
Supply only PVC float valve of size 15mm dia complete suitable for 40/80/120/150 Ltr capacity water coolers including GI socket of same size all as directed. (Make:- Prayag/ Polytuff)
Supply only starting Capacitor 25 MFD. (Make :- Usha/Epcos/Keltron)
Supply only running Capacitor 10 MFD. (Make :- Usha/Epcos/Keltron)
Supply only Starting relay suitable for 40/80, 60/120, 150/150 Ltr. (Make:- Renutrol/Sri Ram/ Microtech). Note for item No 4 to 13:- Materials of item No 4 to 13 to be incorporated in item No 3 here-in-before.
Disconnecting the electric mains and taking out unserviceable condenser fan motor 1/16 HP from water cooler cap.60/120, 150/150 Ltr and supply & fixing new fan motor single phase AC 220 V of same capacity including reconnecting the electric connections and testing complete all as directed by Engr-in-Charge. (Make:- AUE/ Crompton Greaves / Cool Master)
-ditto- all as per item No.14 above but 1/32 HP Water cooler of Capacity 40/80 Ltrs. (Make:- AUE/ Crompton Greaves / Cool Master)
Disconnecting the electric and Water connections and taking out the existing unserviceable compressor of any make from water cooler storage type capacity 40/80 Ltrs from any location and supply installation & testing of new sealed unit compressor of similar capacity in same location alongwith test Certificate from manufacturer and cleaning of condenser by machine doing vacum the fully system and supply and charging of refrigerent gas R-22/134A and other necessary lubricants including reconnecting the electric and water connections, transportaion & testing complete all as directed by Engr-in-charge. (Make Tecumseh/Emerson/LG.)
Disconnecting the electric and Water connections and taking out the existing unserviceable compressor of any make from water cooler storage type capacity 60/120 Ltrs from any location and supply installation & testing of new sealed unit compressor of similar capacity in same location alongwith test Certificate from manufacturer and cleaning of condenser by machine doing vacum the fully system and supply and charging of refrigerent gas R-22/134A and other necessary lubricants including reconnecting the electric and water connections, transportaion & testing complete all as directed by Engr-in-charge. (Make Tecumseh/Emerson/LG.)
Disconnecting the electric and Water connections and taking out the existing unserviceable compressor of any make from water cooler storage type capacity 150/150 Ltrs from any location and supply installation & testing of new sealed unit compressor of similar capacity in same location alongwith test Certificate from manufacturer and cleaning of condenser by machine doing vacum the fully system and supply and charging of refrigerent gas R-22/134A and other necessary lubricants including reconnecting the electric and water connections, transportaion & testing complete all as directed by Engr-in-charge. (Make Tecumseh/Emerson/LG.)
Disconnecting the mains and taking out the unserviceable condenser coil and S&F new condenser coil as per existing size & patterns for Water Coolers of capacity 60/120, 150/150 Ltrs complete all as specified & as directed. (Make:- Universal/ CAIR/ ZECO)
Disconnecting the mains and taking out the unserviceable condenser coil and S&F new condenser coil as per existing size & patterns for Water/Coolers of capacity 40/80 Ltrs complete all as specified & as directed. (Make:- Universal/ CAIR/ ZECO)
Dismantling the evaporator/cooling coil of window type Air Conditioner of capacity 1.5/ 2TR, checking the leakages of gas and rectify the leakages by brazing or as other manner and refixing the same complete all as specified & as directed by Engr-in-Charge.
Supplying and fixing in repairs of stop valve 15mm bore dia, fancy type chromium plated with long shank and cup (concealed type), screwed both ends for iron pipe or for unions complete all as specified and as directed. (Make : Parryware/ Prayag/ Cera/ Essco.)
Taking down unserviceable PVC connection pipe and Supply & fixing of PVC connections pipe of 15 mm dia bore with PTMT nuts of length 900 mm complete all as specified & as directed. (Make:- Prayag/ Polytuff)
Disconnecting from mains and taking down the unserviceable compressor unit of Refrigerator of any make and type and providing New Compressor suitable for 165 to 210 ltr capacity alongwith test certificate from manufacturer including supply of the refrigerant gas R-22/ R-134A and filling and replacement of filter and put in working condition all as directed by Engineer-in-Charge. (Make :Tecumseh/LG/Godrej.) Note :- The rates quoted by the contractor shall deemed to include the transportation cost from site of installation to contractor's repair workshop and back.
Disconnecting from mains and taking down the unserviceable compressor unit of Refrigerator of any make and type and providing New Compressor suitable for 280 to 310 ltr capacity alongwith test certificate from manufacturer including supply of the refrigerant gas R-22/ R-134A and filling and replacement of filter and put in working condition all as directed by Engineer-in-Charge. (Make :Tecumseh/LG/Godrej.) Note :- The rates quoted by the contractor shall deemed to include the transportation cost from site of installation to contractor's repair workshop and back.
Disconnecting from mains and taking down for servicing of Refrigerator of Capacity 165/180/195/310 and 330 Ltrs including detecting the leakage of gas and refilling of refrigerant , cleaning of cooling coil, condenser, compressors, with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, etc., and keeping the Refrigerator unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required complete all as specified and as directed by Engineer-in-Charge. Note :- 1. Replacement of defective spares for making the Refrigerator units in satisfactory working condition will be measured & paid separately under relevant items and Labour charges for taking out old spares and fixing of new spares shall deemed to be included in unit rate quoted.
Supply only following new spare parts of Refrigerator of capacity 165/180/195/310 and 330 Ltrs:-
Supply only capillary tube of existing size including necessary brazing suitable for 165/180/195/310 and 330 Ltrs capacity refrigerator complete all as specified and directed.
Supply only over load protector relay suitable for 165/180/195/310 and 330 Ltrs capacity refrigerator all as directed. (Make:- Renutrol/Sri Ram/Microtech)
Supply only thermostat suitable for 165/180/195/310 and 330 Ltrs capacity refrigerators all as directed. (Make :- Indfoss/ Renutrol).
Freezer door suitable for 165/180/195/310 and 330 Ltrs capacity. ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
Supply only vegetable basket with glass suitable for 165/180/195/310 and 330 Ltrs capacity refrigerators. ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Water Cooler.)
Supply only PVC defrost tray suitable for 165/180/195/310 and 330 Ltrs capacity refrigerators. ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Water Cooler.)
Supply only door gasket suitable for upto 250 Ltrs capacity refrigerators. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Water Cooler.)
Supply only door gasket suitable for more than 250 Ltrs and upto 330 Ltrs capacity refrigerators. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Water Cooler.) Note for Item No. 27.01 to 27.08:- Material of item No. 27.01 to 27.08 to be incorporated in item No. 26 here-in-before.
Disconnecting from mains and taking down for servicing of Deep freezer of Capacity upto 500 Ltrs including detecting the leakage of gas and refilling of refrigerant , cleaning of cooling coil, condenser, compressors, with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, etc., and keeping the Refrigerator unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required complete all as specified and as directed by Engineer-in-Charge. Note :- 1. Replacement of defective spares for making the Deep Freezer units in satisfactory working condition will be measured & paid separately as 'Supply only' under relevant items and Labour charges for taking out old spares and fixing of new spares shall deemed to be included in unit rate quoted.
Supply only following new spare parts of Deep freezer 165/180/195/310/330/450 and 500 Ltrs capacity:-
Starting relay 1/6 H.P. Open type with O.L.P. ( Make :- Renutrol/ Sri Ram/ Microtech).
Starting relay 1/8 H.P. open type with O.L.P. ( Make :- Renutrol/ Sri Ram/ Microtech).
Over load protector device for deep freezer upto 500 ltrs capacity. (Make: Sri Ram/ Renutrol/ Micro Tech.)
Running capacitor for deep freezer upto 500 ltrs capacity. (Make- USHA/EPCOS/KELTRON)
Thermostat switch for deep freezer upto 500 ltrs capacity.( Make :- Indfoss/ Renutrol).
Starting capacitors for deep freezer upto 500 ltrs capacity. (Make:- Epcos/ Usha/ Keltron.)
Axial fan for deep freezer upto 500 ltrs capacity. Note for item No 29.01 to 29.07 :- Materials of item No 29.01 to 29.07 to be incorporated in item No 28 here-in-before.
Taking down defective compressor of deep freezer of capacity upto 300 Ltrs and any make and supplying and fixing new sealed unit compressor including brazing and with necessary nuts and bolts, copper filter, capillary and supply and charging of refrigerant gas Non CFC based or equivalent to Non CFC gas is required quantity and testing complete all as specified and directed by Engineer- in- Charge. (Make:- Emerson/ Tecumesh/ LG)
-ditto- all as per item No. 30 above but capacity above 300 Ltrs but upto 500 Ltrs deep freezer compressor. (Make:- Emerson/ Tecumesh/ LG)
Supply and fixing in repairs metal clad socket outlet with single pole and nuetral enclosure with two pin and earth plug socket complete with one single pole MCB 40 Amps iincluding taking down old unservisible metal clad socket complete all as specified and as directed. (Make : Schneider/ Legrand/ ABB/ Seimens/L&T)
M&L for dismantling the existing window type air conditioner complete of capacity 1.5/2.0 TR, and re-fixing to any other locatin after servicing including cutting of window grills, covering the open space of old locatin and new place of fitting with 4mm thick plywood including two coats of synthetic enamel paints over a coat of pink primer complete all as specified and directed by Engineer-in-Charge. ( Make of ply:- Century/ Dura/ Greenply/ Kitply) (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
M&L for dismantling the existing Split type air conditioner complete including indoor and outdoor units of capacity 1.5/2.0 TR, and re-fixing to any other location after servicing including gas charging as per requirement and other fixing accessories complete all as specified and directed by Engineer-in-Charge.
S&F in repairs desert cooler body of size 25 inch x 25 inch x 36 inch (height) with side panels (03 Nos) fabricated out of 20 SWG PGI Sheet alongwith PVC front grill, distribution switch, 5 Amp piano switch and tank of depth 11 inch. Painting the complete desert cooler i.e, side panel, bracket body with two coat of synthetic enamel paint (Ist grade quality) over a coat of red oxide zinc chrome primer and two coat of black water proof paint on reserve tank and marking with "GE (U) P&M (MES)" letter size of 50mm height in stencil in black/white all as specified and directed by Engr-in-Charge. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
M&L for taking down desert cooler of any type/size/model from any height / floor for servicing like changing of wood wool pads, kit motor, submersible pump, fan blade, front grill, wiring, capacitor, cleaning or any other repair work as specified and re-fixing to existing place after repair work/overhauling complete all as specified and directed. Note :- (i) The rates quoted by the contractor shall deemed to include the cost of T&P. (ii) Replacement of defective spares for making the Deep Freezer units in satisfactory working condition will be measured & paid separately as 'Supply only' under relevant items and Labour charges for taking out old spares and fixing of new spares shall deemed to be included in unit rate quoted.
Supply only wood wool pad approximate weight 800 - 900gms of size 24” sweep desert cooler complete all as specified and directed.
Supply only wood wool pad approximate weight 700 - 800gms and 20” sweep complete all as specified and directed. Note for item No 37 & 38:- Materials of item No 37 & 38 to be incorporated in item No 36 here-in-before.
Supply and fixing in repairs submersible pump motor 230 Volts , single phase, AC suitable for Plastic body/Steel body Desert cooler complete all as specified & as directed. (Make- Kirloskar/Bajaj/ Crompton Greaves/ KSS.)
Supply and fixing in repairs of desert cooler kit fan motor copper wounded single speed having 1450 RPM, 90 watts with suitable for operation on 230 volts, 50Hz, AC supply including nuts, bolts, washers etc. of suitable size and all other fixing accessories complete all as specified & as directed. (Make:- Khaitan/ Crompton/ Usha.)
Supply and fixing in repairs of exhaust fan motor copper wounded having 1400 RPM, 150 watts with 500mm sweep suitable for operation on 230 volts, 50Hz, AC supply including fan brackets/ clamps of suitable size and all fixing accessories complete all as specified & as directed. (Make:- Khaitan/ Crompton/ Cool master.)
Supply and fixing in repairs of front grill for desert cooler of approved make complete with 5 Amp switch, three speed regulator including indicator lamp complete all as specified and directed.
Supply & fixing in repairs of running capacitor of 4 MFD capacity complete all as directed. (Make- USHA/EPCOS/KELTRON)
Supply & fixing in repairs of running capacitor of 6 MFD capacity complete all as directed. (Make- USHA/EPCOS/KELTRON)
Supply & fixing in repairs of GI wire mesh (as per sample) for desert cooler pad (Set of Three).
Supply & fixing in repairs of PVC pipe for connecting pump and water distributor of size 15 mm complete all as specified & as directed. (Make:- Prayag/ Supreme/ Prince).
Supply & fixing in repairs of PVC elbow for desert cooler of suitable size complete all as specified & as directed. (Make:- Prayag/ Polytuff).
Supply & fixing in repairs of PVC 4 Way distribution cross for desert cooler complete all as specified & as directed. (Make:- Prayag/ Polytuff).
Supply & fixing in repairs of flexible copper conductor cable, 3 core PVC insulated & PVC sheathed of size 1.5sqmm complete all as specified and directed. (Make:- Polycab/ Kalinga Premium/Finolex/ RR Kabel/ Havells)
Supply & fixing in repairs of desert coolers fan blade of size 450mm (18 inch) sweep of aluminium body complete all as specified & as directed.
-ditto- all as per item No 50 here-in-before but 500mm (20 inch) sweep.
Supply and fixing in repairs of side panel of desert cooler of 500mm (20”) sweep made out with GI sheet of 20 SWG duly painted with two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide zinc chrome primer complete all as specified & as directed. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
Supply and fixing in repairs of switch piano flush type single pole one way 5Amp / 6 Amp 230 V for desert cooler all as directed (Make-Anchor/ Kinjal/ Havells).
Supply and fixing in repairs of 3 pin plug top 5 Amp, 230V for desert cooler complete all as specified and directed (Make-Anchor/Kinjal/Havells).
Supply and fixing in repairs of 3 pin plug top 15 Amp, 230V for desert cooler complete all as specified and directed (Make-Anchor/Kinjal/Havells).
Supply and fixing in repairs of cooler fan motor bracket sets made up as per existing including painting complete all as specified and directed.
Preparation for old painted surface of desert cooler of any capacity and any make on inner surface & outer surface. Repainting the complete desert coolers ie side panel, bracket, body & desert cooler stand with two coats of synthetic enameled paint (1st grade quality) including two coats of black water proof paint on reserve water tank & marking with “ GE(U) P&M (MES)” letter size of 50mm height in stencil in black/white including servicing and greasing of fan motor/pump and replacement of PVC pipe worn out nut, bolts and washers complete all as per site requirement. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
SNOWY ENGINEERING INC
P S TRADERS
RUCHIKA ENGG.WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .