Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAccepted-Finance 130 KALIKATALA PARK S P O BANSDRONI KOLKATA 700070 | KOLKATA | 24 PARAGANAS SOUTH | WEST BENGAL | 700070 | L1 | Accepted-Finance FIRST LOWEST | |
| 2 | L2₹4.3 L+₹1,078.35 (0.25%)Rejected-Finance | L2 | Rejected-Finance SECOND LOWEST | |
| 3 | L3₹4.3 L+₹2,113.31 (0.49%)Rejected-Finance 0 SATGACHIA BAZAR MEMARI ROAD SATGACHIA BAZAR PURAB BURDWAN WEST BENGAL 713422 | PURBA BARDHAMAN | WEST BENGAL | 713422 | L3 | Rejected-Finance THIRD LOWEST |
Tender Value
₹4.3 L
EMD Value
₹8,700
Closing Date
16 Aug 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
BDO, Kaliachak-I, Malda
Office of the Block Dev. Officer, Kaliachak-I Dev. Block, Malda
Conversion of Sub-Center to Su-Sasthya Kendra (HWC) at Balugram SC under Kaliachak-I Dev. Block,Malda.
2022_DMM_392645_2
N.I.E.T No. BDO/KCK-I/NIET- 01 (e) of 2022-2023
Open Tender
CIVIL WORKS
Item Rate
45 days
KALIACHAK
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹8,700
Yes
20 Sept 2022
1 Aug 2022
18 Aug 2022
1 Aug 2022
16 Aug 2022
1 Aug 2022
Amount
BUILDING WORKS
Stripping off worn out plaster and raking out joints of walls, celings etc upto any height and inany floor including removing rubbish within alead of 75m as directed.
125 mm thick brick work with 1st class bricks in cement morter (4:1)
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] i) With 6:1 cement Plaster. c) 15 mm thick plaster.
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (ii) Two coats (white in shade) (a) On timber or plastered surface : With super gloss (hi-gloss) -
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (ii) Two coats (white in shade) (b) On steel or other metal surface : With super gloss (hi-gloss) -
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC.In Ground Floor (b) Two coats.
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC.In First Floor (b) Two coats.
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer in Ground floor (Two Coat). c) Super Protective 100% Acrylic Emulsion
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer in First floor (Two Coat). c) Super Protective 100% Acrylic Emulsion
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (a) One Coat ii) Solvent based interior grade Acrylic Primer
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In First Floor) (a) One Coat ii) Solvent based interior grade Acrylic Primer
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats (Ground Floor)
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats (First Floor)
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg /Sq.m. (a) Area of each tile upto 0.09 Sq.m (i) Coloured decorative (KAJARIA, JONSON, CERA, SOMANI, ORIENT, RAK, NITCO)
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) Area of each tile upto 0.09 Sq.m (i) Coloured decorative (KAJARIA, JONSON, CERA, SOMANI, ORIENT, RAK, NITCO)
Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (A) Deep Colour & White (KAJARIA, JONSON, CERA, SOMANI, ORIENT, RAK, NITCO) IN FIRST FLOOR
Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding 'P' or 'S' trap (excluding cost of concrete for fixing). (i) 580 mm X 440 mm
Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. (a) Sink only (ii) 630 mm X 550 mm X 180 mm
Wash basin vitreous china of approved make (without fittings) supplied,fitted and fixed in position on 75mm X 75 mm X 75 mm wood blocks and C.I. brackets including two coats of painting of C.I. brackets. (ii) 550 mm X 400 mm size
Supplying, fitting and fixing pillar cock of approved make.
Supplying, fitting and fixing towel rail with two brackets. (a) C.P. over brass (ii) 25 mm dia. and 600 mm long
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm
Earthwork in excavation in foundation trenches or drain in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading & stacking the spoil within a lead of 75m as directed. The item includes necessary trimming the sides of trenches. Levelling, dressing and ramming the bottom, bailing out of water as required complete.
Cement concrete (1:3:6) with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety]
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (Rajmahal Variety)
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction (upto roof of ground floor)
Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paintin any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work (ii) 40 mm dia. medium quality
Supplying, fitting & fixing polycarbonate sheet of approved make & brand conforming to IS: 14443-1997 and having 50 micron UV protection layer under co-extrusion technology, Fire rating being B-s1 as per EN13501-1 certification, fitted and fixed with 60mm wide aluminium channel section top and bottom member in dry-glaze sandwitch system, (unit wt. of top and bottom members: 0.375 kg/m & 0.69 kg/m) of approved brand and profile, EPDM quality rubber gaskets, anti dust tape, end closer "C" channel and 75 mm long Self tapping screw being drilled through the centre leg of the bottom section with nuts placed at 300 mm apart without anyway puncturing the polycarbonate sheet, EPDM Washer 16 mm dia & 3 mm thick washer etc complete strictly as per manufacturers specification and direction of Engineer-inCharge. (Payment to be made on area of finished work) . In Roof:- Natural/ Blue/Green/Bronze/Opal/Metallic grey colour c)With 2 wall 10 mm overall thickness
Supplying, fitting and fixing glass reinforced polyester translucent fiber glass sheet to match with GCI Corrugation as per IS: 12866 - 1989 in roof fitted and fixed with 10 mm dia "J" or "L" hook, bolts and nuts, limpet and bitumen washers and putty with 150mm end lap and one corrugation minimum side lap complete. b) 2.0mm +/- 0.2 mm thick sheet.(3.25Kg/Sq.m) iii) Coloured other than natural white or tinted blue
As per S & P Schedule Page No-49 Item No-1. Labour for boring tubewell of required diameter by water jet system through any kind of soil i/c hire and labour charges for boring pipes, scafolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting fixing same complete i/c bucketing fixing of tubetubewell head in position and other related incidental works in the connection.The tubewell should have a min 50mm gap in between the outside of tubewell pipe and bore. For depth upto 150m, 50mm dia. tubewell with top enlargement 100mm dia. a) 50 mm dia. Boring.
As per S & P Schedule Page No-49 Item No-1. Labour for boring tubewell of required diameter by water jet system through any kind of soil i/c hire and labour charges for boring pipes, scafolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting fixing same complete i/c bucketing fixing of tubetubewell head in position and other related incidental works in the connection.The tubewell should have a min 50mm gap in between the outside of tubewell pipe and bore. For depth upto 150m, 50mm dia. tubewell with top enlargement 100mm dia. b) 100 mm dia. Boring.
As per S & P Schedule Page No-53 Item No-9. Supplying fitting fixing of steel cutter piece upto 450 mm long with sockets a) 40 mm dia.
As per S & P Schedule Page No-13 Item No-19(III) Supply P.V.C. rigid pipe & fittings (Medium Duty) conforming ASTMD -1785 & Threaded to match with GI- pipes as per IS: 1239 (Part-I) a) PVC rigid pipes (Dia) 40 mm
As per S & P Schedule Page No-13 Item No-19(III) Supply P.V.C. rigid pipe & fittings (Medium Duty) conforming ASTMD -1785 & Threaded to match with GI- pipes as per IS: 1239 (Part-I) b) PVC rigid pipes (Dia) 80 mm
As per S & P Schedule Page No-13 Item No-19(III) Supply P.V.C. rigid pipe & fittings (Medium Duty) conforming ASTMD -1785 & Threaded to match with GI- pipes as per IS: 1239 (Part-I) c)Threaded Adopter (Dia) 40 mm
As per S & P Schedule Page No-13 Item No-19(III) Supply P.V.C. rigid pipe & fittings (Medium Duty) conforming ASTMD -1785 & Threaded to match with GI- pipes as per IS: 1239 (Part-I) d) Reducing Sockets 40 x 80 mm dia
As per S & P Schedule Page No-110 Item No-16 Supplying fitting & fixing of G.I. reducing elbow. (x) 40 mm X 32 mm
As per S & P Schedule Page No-56 Item No-28 Supplying fitting & fixing of 200 mm centre guide. i) With Clamp
Non Schedule Item(Rate adopted from local Market price)- Supply and fitting 2.5 mm gauge water proofing cable wire for fitting submersable motors.
Non Schedule Item(Rate adopted from local Market price)- Supply,fittings, fixing 01 H.P. Submersable pump with motor of 100 mm dia of approved make and brand (Crompton) with panel box, cable and all necessary fittings.
Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required.
Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction.
Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-incharge including cost of all materials labour and equipment complete.
Packing annular space between the outside of the housing pipe and the bore with puddled clay balls of approved size as per direction of the Engineer -in-charge with cost of all materials and labour complete.
Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete.
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge.
Cost of Electrical Works as per Model Estimate
Goods and Service Tax @ 12%
Labour and Welfare Cess @ 1%
LOVELY ENTERPRISE
BISWAS ENTERPRISE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .