Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹17.5 L+₹2.0 L (12.7%)Rejected-Finance JOGESHWARI W 758 ADARS NEW LINK ROAD 758 ADARS MUMBAI 400101 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400101 | L2 | Rejected-Finance Other than L1 |
Tender Value
₹16.5 L
EMD Value
₹33,000
Closing Date
27 Apr 2021, 6:00 pmClosed
GE(AF) GORAKHPUR
GE(AF) GORAKHPUR Pin-273008
SPECIAL REPAIR TO PATIENT MESS AT 12 AFH AND PROVISION OF SHED NEAR SHOPPING COMPLEX AKASH VIHAR AT AIR FORCE STATION GORAKHPUR
2021_MES_434032_1
8783/E8
Open Tender
Civil Works
Item Rate
120 days
GE(AF) GORAKHPUR
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE(AF) GORAKHPUR
₹33,000
Yes
31 May 2021
1 Apr 2021
28 Apr 2021
1 Apr 2021
27 Apr 2021
15 Apr 2021
Amount
Taking down cement or cement lime plaster any description on brick or stone walls, etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified as directed.
M&L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces of wall, finished surface even and smooth without using extra cement complete all as specified as directed.
M&L for rendering 5mm thick in CM 1:3 on ceiling, surface finished even and smooth without using extra cement complete all as specified as directed.
M&L for preparation new plastered surface of wall and applying two coat of oil bound distemper and a coat of primer over a coat of 1mm thick Birla putty as base coat complete all as specified and directed.
M&L for preparation new plastered surface of ceiling and applying two coat of white wash complete all as specified and directed.
M&L for complete removal of existing treatment from surface of wall and applying two coat of oil bound distemper and a coat of primer over a coat of 1mm thick Birla putty as base coat complete all as specified and directed.
M&L for preparation old decorated surfaces of any description, including cornices and applying one coat of white wash on ceiling complete all as specified and as directed.
Taking down chawkhats or frame with shutter (without taking out shutter from the frame n.exc 1.50 sqm each and removing from site complete all as specified and directed.
All as per Item No. 8 above but exc 1.50 sqm and n.exc 4 sqm each.
Taking down shutter of any description exc 1 sqm and n.exc 2 sqm each and removing from site complete all as specified and directed
M&L second class hard wood plain, solid, chowkhat and frames wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified as directed.
S&F 30mm thick flush shutter, factory made, solid core construction with particle board care and plywood face panels commercial type on both side complete all as specified and as directed.
M&L for second class hard wood glazed and skeleton shutter 35mm thick, factory made, open rebated and prepared to receive glass/gauge etc, without sash bars, mitered and rebated, with edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass/gauge etc, sizes of stiles, rails etc as specified in Section 8, clause 8.24(a) of SSR part-I (2009).
S&F 75mm size mild steel butt hinges, medium weight cold rolled complete all as specified and directed.
S&F 100mm size mild steel butt hinges, medium weight cold rolled complete all as specified and directed.
S&F 150mm long aluminium anodized barrel tower bolt, complete all as specified and directed.
S&F aluminium anodized pressed handle, fabricated type of size 100mm, complete all as specified and directed.
S&F aluminium anodized pressed handle, fabricated type of size 150mm, complete all as specified and directed.
S&F 300mm long aluminium anodized sliding door bolt with hasp & staple (bolt type) fixing clips of sheet cast or extruded section & fixing bolts, sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed.
S&F 100mm size aluminium anodised hasp & staple safety type with hinge pin incl bolts to hinge plate fixed with screws complete all as specified and directed.
S&F in repair stainless steel wire cloth 0.36mm nominal dia of wire and avg width of aperture 1.40 mm fixed with tinned tacks or stainless steel wire staples complete all as specified and directed.
S&F mild steel helical door spring rat tail rod model including roller plate complete 300 mm long complete all as specified and directed.
S&F 150 mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring fixed in floor complete all as specified and directed.
M&L for preparation of old painted wooden surface of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of old painted steel surface of any description, over 10cm width or girth and apply one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of new or previously untreated surfaces of wood or wood based materials of any description, not other wise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of steel of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F in repair alumnium curtain rod (Dropery rod) plastic coated 20 mm dia including bracket, end Knobs fancy type nickel polished golden or sliver colour as per sample. complete all as specified as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for glazed ceramic tiles in vertical surface of size 450x 350x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tile over screed bed 10 mm thick in CM 1:3.
S&F non skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.11sqm and n.exc. 0.18 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over 15 mm thick screed bed in cement mortar 1:6 etc complete all as specified and directed.
S&F 18-20mm thick pre-polished varoda green stone slab of approved shade and colour as in steps, joints, cills, cooking platform etc or on vertical surfaces including vertical projection, laid over and including screed bed 15mm thick in CM 1:4, jointing, pointing complete as directed.
Rounding to edge of stone slab one edge, such on in stop, cooking platform, and other similar situation complete all as specified and directed.
Taking up or down steel tubing and connections 15mm bore complete all as specified and directed.
All as per item No. 34 above but 20mm bore.
S&F 15mm bore steel water tubes "medium grade" galvanized with all fittings such as bends, elbows tee etc and fixed to walls and ceiling in floor complete all as specified and directed.
All as per item No. 36 above but 20mm bore.
M&L for cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 for concealed water tubing/electrical wiring, cutting n.exc. 10cm girth complete all as specified and directed.
Taking down rain water pipes with fittings of 100mm dia complete all as specified and directed.
S&F 110mm bore PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber ring joints, fixed to walls or laid in trench complete all as specified and directed.
S&F 110 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F in repairs 75mm dia cast iron floor trap with CP grating including jointing to waste pipe complete all as specified and directed.
S&F in repair stainless steel sink with drainage board made out of 1mm thick steel sheet for kitchen with plug, washer waste pipe, MS cantilever bracket, waste coupling, waste pipe connection union overall size 915x460mm with bowl size 410x310x160mm complete all as specified and directed.
S&F in repair concealed stop valves 15 mm bore fancy type, chromium plated, with long shank and cup, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F in repairs 15 mm bore angle cock brass chromium plated fancy type, screwed for iron pipe complete all as specified and directed.
S&F in repair for 20mm bore gun metal, globe or gate valves, with iron wheel hand, screwed both ends for iron pipes complete all as specified directed.
Demolition of cement concrete un-reinforced in ground floors and paving not exc 15 cm thickness below or above ground level complete all as specified and as directed.
Dismantling brick or brick tiles laid bedded and pointed in any type of mortar as on roof etc complete all as specified and directed.
Dismantling/striping out of existing roof treatment (tarfelt & roof plaster etc) including PCC padding of any description, and any thickness including backing, and remove the debris complete all as specified and directed.
Roughening surfaces of old concrete floor by sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 Kg of cement per Sqm complete all as specified & directed.
M&L for cutting out cracks of roof in V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in roof padding to maintain proper slope mixed with water proofing compound @ 3% by weight of cement, complete all as specified and directed. Note:-WPC will be measured & paid separately)
M&L for 10 mm thick rendering on fair faces of brick work or on concrete surface in CM 1:3 finished surface even and smooth without using extra cement mixed with liquid water proofing compound @100 ml per 50 Kg of cement bag complete all as specified and directed. Note: WPC will be measured and paid separately.
M&L for providing roof treatment as per latest zonal specification specified:- (a) Applying a coat of bitumen primer @ 0.25 ltrs/sqmts and allow to dry. (b) Applying one coat of hot blown bitumen grade 85/25 @ 1.20 Kg/sqmts. (c) Applying APP modified polymeric membrane of weight not less than 3.0Kg/Sqm laid and bonded to the sub strata by heat process, over laps of 100mm shall be sealed/fused by flame torch application as per manufacturer instructions. (d) Screeding 15 mm thick in CM 1:4 as bedding layer using 100% coarse sand (e) S&F 40 mm thick brick tiles jointed and pointed in CM 1:4 mixed with linseed oil @ 5% by weight of cement.
M&L for water proofing treatment to roof surface complete all as specified and directed with the followings:- (a) Applying bituminous based primer confirming to IS:3384-1965 @ 0.25 litre per sqm (b) Applying a tack coat of hot blown bitumen grade 85/25 confirming to IS:702 @ 1.20 Kg per sqm (c) Applying APP modified polymeric membrane of weight not less than 3.6Kg per sqm laid and bonded to the sub strata by heat process, over laps of 100mm shall be sealed/fused by flame torch application as per manufacturer instructions. (d) Blinding with coarse sand dry @ 0.50 to 1.00 Kg/sqmts dusted over bitumen and applying one coat of aluminium paint.
M&L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in roof kerb or mud stops, rounded or chamfered on edges surface finished even and smooth without using extra cement, mixed with liquid water proofing compound @100 ml per 50 Kg of cement bag complete all as specified and directed. Note: WPC will be measured and paid separately.
Supply only integral liquid water proofing compound complete all as specified and directed. Make:- Dr Fixit Pidiproof LW+ or equivalent in specified make.
M&L for machine cut Kota stone slab 20 to 25mm thick (minimum size 30cmx 45cm) as in flooring, laid over and including cement screed bed 20mm thick in cement mortar 1:4, and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and granite polishing complete all as specified.
Excavation in post holes (or similar holes) each n.exc 0.5cum getting out, returning, filling in watering and ramming earth or broken rubble mixed with earth around in layers n.exc 25cm thick in soft/loose soil, making good surface and disposal of surfaces spoil to a distance not exc 50 Mtrs complete all as specified and as directed.
Excavation in trenches n.exc 1.5M wide and n.exc 1.5 M deep for foundation and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation filling or mass concrete complete all as specified and directed.
S&F mild steel posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron fillets (for securing wire mess etc) including all necessary drilling, bolting or riveting etc and similar work complete all as specified and directed.
S&F mild steel rolled work as in main and cross beams, hip, jack rafters, purlins connected to common rafter & running rails guides for sliding doors fixed with angle cleats and other plates distance pieces cleats etc of Fe-410 W (grade E-250) quality-B. complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick (BMT) of any colour having tensile strength of 550 Mpa as in valley gutter, ridge of roof covering/ cladding to wall, fixing with self tapping screws complete all as specified and directed.
M&L for brick work with sub class B bricks of old size, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and directed.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, 5 to 10mm dia of neck exc 5cm and n-exc 10cm long complete all as specified and directed.
Taking down carefully copper/aluminium point wiring light/fan/ bell/socket or power complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc are to be measured separately) and/or drawing out from existing conduit/batten and making good disturbed surfaces of walls/floors/ ceilings complete all as specified and directed .
M&L for point wiring for one light/fan point controlled by one switch with (FRLS) Fire retardant low smoke PVC insulated unsheathed cable 1.5 sqmm with stranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia medium grade with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc with provision of new GI terminal boxes of not less than 1.60mm wall thickness with decorative laminated sheet top cover 3 mm thick (Hylam) including (FRLS) Fire retardant low smoke PVC insulated copper earth conductor 1.50 sqmm connected to common earth and earth dolly complete all as specified and directed.
All as per item No. 70 above but for one socket outlet 3/5 pin 5/6 amps independent controlled by one switch.
All as per item No. 70 above but for one socket outlet 3/5 pin 5/6 amps independent controlled by one switch on same board.
M&L for point wiring with (FRLS) Fire retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of GI terminal boxes of not less than 1.6mm wall thickness with decorative laminated sheet top cover 3 mm thick (Hylam) including (FRLS) Fire retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly complete for 3/6 pin 15 Amps socket outlet on independent board complete all as specified and directed. Note for item Nos 70 to 73:-(i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface.(ii) Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately.
S&F switch piano, flush type 5/6 amp, single pole, one way 240 volt complete all as specified and directed.
S&F switch piano, flush type 15/16 amp, single pole, one way 240 volt complete all as specified and directed.
S&F socket outlet, 3/5 pin, 5/6 amps flush type complete all as specified and directed.
S&F socket outlet, two in one 3 pin, 5/6 & 15/16 amps flush type complete all as specified and directed.
S&F ceiling rose surface polycarbonate 65X50mm three terminals complete all as specified and directed.
S&F fan regulator electronic step up type, SP 230 volt complete all as specified and as directed.
M&L for replacement sub main wiring with 2 Nos single core PVC insulated unsheathed 2.5 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 1.5 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 2.5sqmm conductor cable, 1 No 1.5sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
M&L for replacement sub main wiring with 2 Nos single core PVC insulated unsheathed 4.0 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 2.5sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable concealed PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 4.0 sqmm conductor cable, 1 No 2.5sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
M&L for replacement sub main wiring with 2 Nos single core PVC insulated unsheathed 6.0 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 4.0 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable concealed PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 6.0 sqmm conductor cable, 1 No 4.0 sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
S&F in replacement sheet metal enclosure (MCB DBs) three phase and neutral with 200 Amps rated bus bar 4 way double door type complete all as specified and directed.
S&F in replacement sheet metal enclosure (MCB DBs) single phase and neutral with 200 Amps rated bus bar 8 way double door type complete all as specified and directed.
S&F in replacement sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified.
S&F in replacement MCB TPN 63 Amp 415 volts 10KA breaking capacity 'C' curve complete all as specified and directed .
S&F in replacement MCB, SPN, 32 to 40 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F in replacement MCB, SP, 10 to 32 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600mm X600mmX6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth strip 32x6 mm, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate no 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 6 mm dia MS bars both ways complete all as specified & directed. Note:(a) If less than 5.0 Ohm result has not achieved at site, the contractor is responsible to done grid system to achieve the desired result and no extra payment shall be claimed by the contractor to this effect. (b) Earth continuity conductor of length upto 7.50 mtr from electrode shall deemed to be included in the quoted rate.
S&F ceiling fan having copper winding motor, complete with electronic type regulator and accessories 230 V, 50 Hz AC, 1200 mm sweep BEE 5 star rated complete all as specified and directed. Make:- Bajaj Model Elegance 1200 mm or equivalent model of specified make
S&F exhaust fan single phase 230/240 volt AC 300mm sweep, 1400 RPM, metal body, including cutting holes of suitable size in wall, grouting of nuts and bolt etc required for fixing fan and making good to match the existing surface and making connation with twisted copper flexible wire 23/0.0076mm and writing MES No with black paint complete all as directed. Make: Havells/ Bajaj/ Almonard
S&F 20 watt LED light fitting engineering plastic batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Havells Cat part No.LHEXBXPNIN1W020 or equivalent in Bajaj /CG.
S&F 9 watt LED light fitting engineering plastic batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Havells Cat part No.LHEXBXPNIN1W009 or equivalent in Bajaj /CG.
S&F, installation, testing of electric Water heater storage type geyser (with EPAC Inner Tank & ABS Body with Metallic Finish Color Panel) of capacity 50litres suitable for single phase 230 Volts, AC, 50Hz, BEE 5 star rating complete with all mounting arrangement, Hot & Cold water connection pipe, 3 pin plug top etc as required at site complete all as specified and directed. Note:- Any disturbed surfaces of wall will be matched with existing colour surfaces. complete all as specified. Make: Model Pebble 50L of Make Havells or equivalent in V-Guard/ Bajaj/ Racold
S&F in repairs 15 mm bore bib tap brass chromium plated fancy type with crutch or butterfly handle screwed down, screwed for iron pipe complete all as specified and directed.
Supply, laying and testing in replacement 16 Sqmm, 4 core XLPE insulated, armoured heavy duty electric cable, screened PVC bedded, galvanised steel strip or wire, with aluminium conductor 1100 V grade, laid in trenches/ along poles, ducts or through sleeve complete all as specified and directed.
M&L for replacement sub main wiring with 2 Nos single core PVC insulated unsheathed 1.5 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 1.0 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 1.5sqmm conductor cable, 1 No 1.0sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
S&F in replacement integral building security LED light fittings with pressure dia cast aluminium of 25 watts and including and connecting up ceiling rose and fittings with 3 core, PVC insulated multistranded copper conductor cable of 1.5 Sqmm complete all as specified and directed. Make:- BAJAJ Model No. BRLEP 25W LED or equivalent in Havells/CG.
S&F in replacement brackets made out of 40/50mm dia medium grade GI pipe 1.50 mtr long bent to shape and size fixed on location using new 2 nos 30x5mm FI clamps made to shape incl nuts, bolts & washers complete all as specified and directed.
S&F in replacement PVC casing & capping of size 25mm run in wall/ surface for existing telephone cable/Lan cable complete all as specified and directed.
Disconnecting, taking down & removing carefully the existing ceiling fan, exhaust fans, wall bracket fans, air circulating fans and pedestal fans etc. of any description, any sweep and from any position/locations for repairs/servicing/numbering, dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing, fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades, hanging/fixing the repaired fans in position, connecting to existing electric sources and testing at site to the entire satisfaction of the department complete all as specified and directed.
M&L for painting of existing fans of any description (ceiling fan/exhaust fan/Air circulators/Wall mounted fans/Pedestal fan) with applying one coat of synthetic enamel paint (White) by spray machine including preparation of existing decorated surfaces of fans including engraving MES No. of fan in capital letters of height not less than 20 mm on fan body all as specified and directed.
DEEP ENTERPRISES
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .