Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 LAdmitted-Finance | ₹19.7 L | L1 | Admitted-Finance |
| 2 | L2₹20.7 L+₹98,337.20 (4.99%)Admitted-Finance | ₹20.7 L+₹98,337.20 (4.99%) | L2 | Admitted-Finance |
| 3 | L3₹21.2 L+₹1.5 L (7.62%)Admitted-Finance | ₹21.2 L+₹1.5 L (7.62%) | L3 | Admitted-Finance |
| 4 | L4₹22.5 L+₹2.8 L (14.3%)Admitted-Finance | ₹22.5 L+₹2.8 L (14.3%) | L4 | Admitted-Finance |
| 5 | L5₹25.0 L+₹5.3 L (27.1%)Admitted-Finance DIAMOND STREET 2ND STREET POTTAPEDU ROAD NSC BOSE NAGAR RAMAPURAM CHENNAI TAMIL NADU 600116 | THIRUVALLUR | TAMIL NADU | 600116 | ₹25.0 L+₹5.3 L (27.1%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | POWER TECH ENTEPRISES L3 | ESSENN POWER CONTROLS PVT LTD L1 | Madras Power Corporation L5 | AADHI ELECTRICAL AND CONSTRUCTION L4 | Delhi Electrical Construction L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C | 76 | Nos | 1,000 ₹76,000 Lowest | 1,350 ₹1,02,600 | 1,175 ₹89,300 | 1,000 ₹76,000 Lowest | 1,000 ₹76,000 Lowest |
| 2.00 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVCconduit, and earthing the point with 1.5 sq. mm FRLS/HFFRPVC insulated copper conductor single core cable etc. asrequired.. Group C | 36 | Nos | 1,400 ₹50,400 | 1,200 ₹43,200 | 865 ₹31,140 | 750 ₹27,000 Lowest | 792 ₹28,512 |
| 3.00Sockets:- | ||||||||
| 3.01 | Supplying and fixing suitable size GI box/PVC box suitable to mount in the CMS with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required. | 498 | Nos | 550 ₹2,73,900 | 345 ₹1,71,810 Lowest | 655 ₹3,26,190 | 650 ₹3,23,700 | 400 ₹1,99,200 |
| 3.02 | Supplying and fixing suitable size GI box/PVC box suitable to fix in the CMS with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. | 20 | Nos | 900 ₹18,000 | 450 ₹9,000 | 1,285 ₹25,700 | 825 ₹16,500 | 448 ₹8,960 Lowest |
| 4.00Supplying and fixing of following size MK premium base & lid CMS with accessories including end caps, flexible internal/external corners flat angles,Flat tee, joint cover wherever necessary with cable divider, required type of modular box etc as per the site requirements | ||||||||
| 4.01 | 100mm x 50mm | 300 | Metre | 1,000 ₹3,00,000 | 700 ₹2,10,000 Lowest | 740 ₹2,22,000 | 850 ₹2,55,000 | 805 ₹2,41,500 |
| 4.02 | 50mm x 50 mm | 100 | Metre | 600 ₹60,000 | 650 ₹65,000 | 485 ₹48,500 Lowest | 575 ₹57,500 | 526 ₹52,600 |
| 5.00Supply installation and testing and Following LED lights | ||||||||
| 5.01 | Crompton Make Model VECTOR I to VII LCTLRF (1 to 7)-36-CDL LED Fitting 6500k or equivalent in Philips | 20 | Nos | 3,500 ₹70,000 | 3,550 ₹71,000 | 1,835 ₹36,700 Lowest | 3,500 ₹70,000 | 3,469 ₹69,380 |
Tender Value
₹26.6 L
EMD Value
₹53,160
Closing Date
19 Jan 2026, 3:00 pmClosed
Executive Engineer (Electrical)
Engineering Unit, Admin Block 3rd Floor, IIT Madras CHENNAI-600036
Internal Electrification work at Library 3rd Floor East wing inside IIT Madras
2025_IITM_260868_1
35/2025-26/ELDB
Open Tender
Electrical Works
Item Rate
30 days
IIT MADRAS CHENNAI
All required documents as mentioned in the tender
2 documents required · 2 mandatory
₹0
₹53,160
2 Feb 2026
29 Dec 2025
20 Jan 2026
29 Dec 2025
19 Jan 2026
29 Dec 2025
29 Dec 2025 - 31 Dec 2025
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVCconduit, and earthing the point with 1.5 sq. mm FRLS/HFFRPVC insulated copper conductor single core cable etc. asrequired.. Group C
Sockets:-
Supplying and fixing suitable size GI box/PVC box suitable to mount in the CMS with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required.
Supplying and fixing suitable size GI box/PVC box suitable to fix in the CMS with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing of following size MK premium base & lid CMS with accessories including end caps, flexible internal/external corners flat angles,Flat tee, joint cover wherever necessary with cable divider, required type of modular box etc as per the site requirements
100mm x 50mm
50mm x 50 mm
Supply installation and testing and Following LED lights
Crompton Make Model VECTOR I to VII LCTLRF (1 to 7)-36-CDL LED Fitting 6500k or equivalent in Philips
18W LED Surface mounting fitting complete set. Crompton make Model LCDSPLN-R-18CDL Square or Round or eqivalent in Philips.
Supply and installation of Crompton Make Linear suspend Model TRENDZ CCP-143-36-57-SL-NWH LED Fitting 5700k-6500k or equivalent in Philips
Supply and installation of an Indoor 300mm dia hanging light fixture with 15 Watt classic bulb LHL201E27 ( LUKAR) or equivalent in Philips/Crompton
Supply of Indoor hanging light fixture with 36 Watt Crompton LUNAR LCSUR4-36-CDL or equivalent in in approved makes.
Supply of Indoor hanging light fixture with 36 Watt crompton-CAPELLA CCP-129-36-57-SL-NWH or equivalent in approved makes.
Supply of Indoor hanging light fixture crompton EPSILON CCP-128-36-57-SL-NWH or equivalent in approved makes.
Installation charges indoor hanging light fitting for item no :- 5.05, 5.06, 5.07. Including light fittings installtion with reuired accessories, connection, etc.
Supply, Installation, Testing and Commissioning of 1200mm, Brush Less Direct Current (BLDC) Motor the ceiling fan
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS/HFFR PVC insulated copperconductor, single core cable in surface/ recessed mediumclass PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing of 8 way (4 + 24), Double door surface/ recess mounting, vertical type, 415 V, TPN MCCB/MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar,din bar for mounting MCCB/MCBs (but without MCCB/MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
Supplying and fixing of 12 way, Double door way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Providing and fixing 100 A, 16 KA,TPMCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Double pole
Triple pole
Supply and fixing of GI floor junction box with necessary accessories
250mm X 250mm
150mm X 150 mm
Supply and fixing of 100x 50mm Aluminum/ GI floor race way with necessary accessories
Supply and fixing of LED profile lights with 23mm profile, LED strip 180 LED/mtr
Supplying and installing 150 mm width X 50 mm depth X 1.6 mm of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastner etc as required.
Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.20 MB
TenderNoT35.pdf
Tender Documents • 1.52 MB
PriceBidForViewT35.pdf
Other Document • 0.62 MB
BOQ_301740.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .