| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC | L1 | Accepted-AOC tenderaccepted | |
| 2 | L2₹13.8 L+₹32,862.30 (2.44%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹14.1 L+₹61,386 (4.55%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹15.0 L+₹1.5 L (11.0%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹17.3 L+₹3.8 L (28.5%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L5 | Rejected-Finance Not being L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
29 Nov 2019, 6:00 pmClosed
GE Faizabad
GE MES Faizabad
REPAIR MAINTENANCE OF LT PANELS MCCBS CABLES AND MISC WORKS AT FAIZABAD
2019_MES_291895_1
8925/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Faizabad
As per tender documents
7 documents required · 7 mandatory
₹500
GE Faizabad
₹40,000
Yes
7 Jan 2020
22 Oct 2019
2 Dec 2019
22 Oct 2019
29 Nov 2019
12 Nov 2019
Amount
Excavation in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation of poles, stays or for taking out/laying of cables and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in soft/loose soil complete all as specified and directed by Engr-in-Charge
Removing excavated materials (soil) to a distance n. exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
M & L for sand cushioning to underground cable with clean dry river sand complete all as specified and directed by Engr-in-Charge. Note:- Punned thickness only shall be measured & Paid.
Supply & Laying of sub class 'B'bricks locally available best quality laid flat (length of bricks laid across the length of cable) in tranches for protection of U/G cable complete all as specified and directed by Engr-in-Charge.
Hiring of cable fault detector, to detect exact position of fault for XLPE /PVC LT/HT cable, 1100/11000 Volts grade heavy duty aluminium conductor of any size including to and fro transporting charges etc. complete all as specified and directed by Engr-in-Charge.
S & F Straight through cable joint kit for LT UG cable of 16 Sqmm 4 Core size complete all as specified and directed by Engr-in-Charge.
S & F Straight through cable joint kit for LT UG cable of 25 to 50 Sqmm 3.5 Core size complete all as specified and directed by Engr-in-Charge.
S & F Straight through cable joint kit for LT UG cable of 70 to 150 Sqmm 3.5 Core size complete all as specified and directed by Engr-in-Charge.
S & F Straight through cable joint kit for LT UG cable of 185 to 240 Sqmm 3.5 Core size complete all as specified and directed by Engr-in-Charge.
S & F Straight through cable joint kit for LT UG cable of 300 to 400 Sqmm 3.5 Core size complete all as specified and directed by Engr-in-Charge.
Horizontal boring in soft/loose soil/under roads of any width by manual arrangements for inserting GI pipe up to 100mm bore for passing cables complete all as specified and directed by Engr-in-Charge. Note : GI pipe shall be measured and paid separately.
Supply & laying steel tubing of size GI Pipe 50mm dia, galvanized light grade bores, for passing LT/HT cable under road or PCC floor or fixed on wall/on pole or drain etc or whenever protection is required including necessary clamps and nut bolts with GI fitting complete all as directed and specified
Supply & laying steel tubing of size GI Pipe 80mm dia, galvanized light grade bores, for passing LT/HT cable under road or PCC floor or fixed on wall/on pole or drain etc or whenever protection is required including necessary clamps and nut bolts with GI fitting complete all as directed and specified
Taking out U/S LT UG cable of any size cable all as directed by Engr-In-Charge. Note:- Excavation and earth work shall be measured paid separately under respective item.
Supplying, laying, commissioning & testing LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of 4 Sqmm 2 Core size including taking out old unserviceable cables, protection pipes/bricks or precast concrete cable covers, etc. complete all as specified and directed by Engr-in-Charge.
Supplying, laying, commissioning & testing LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of 10 Sqmm 2 Core size including taking out old unserviceable cables, protection pipes/bricks or precast concrete cable covers, etc. complete all as specified and directed by Engr-in-Charge.
Supplying, laying, commissioning & testing LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of 16 Sqmm 4 Core size including taking out old unserviceable cables, protection pipes/bricks or precast concrete cable covers, etc. complete all as specified and directed by Engr-in-Charge.
Supplying, laying, commissioning & testing LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of 25 Sqmm 3.5 Core size including taking out old unserviceable cables, protection pipes/bricks or precast concrete cable covers, etc. complete all as specified and directed by Engr-in-Charge.
Supplying, laying, commissioning & testing LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of 50 Sqmm 3.5 Core size including taking out old unserviceable cables, protection pipes/bricks or precast concrete cable covers, etc. complete all as specified and directed by Engr-in-Charge.
Supplying, laying, commissioning & testing LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of 95 Sqmm 3.5 Core size including taking out old unserviceable cables, protection pipes/bricks or precast concrete cable covers, etc. complete all as specified and directed by Engr-in-Charge.
Supplying, laying, commissioning & testing LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of 120 Sqmm 3.5 Core size including taking out old unserviceable cables, protection pipes/bricks or precast concrete cable covers, etc. complete all as specified and directed by Engr-in-Charge.
Disconnecting electrically incomming and outgoing LT UG cable of LT panel of any size and replace burn/unsv suitable size of aluminium bus bar, Welding work for hinches and doors, fixing the locking arrangement including scraping outdoor/indoor side of LT Panel and one coat of redoxide, two coat of synthetic enamelled seimens gray spray of outdoor/Indoor side and reconnecting LT UG cable with fixing aluminium lugs by using crimping tool, nut, bolt washer etc and all necesary work required for smooth functioning of LT panel all specified and directed by Engr-in-Charge.
M&L for Indicator lamp LED type (R,Y,B) complete with bakelite fuse complete all as specified and directed by Engr-in-Charge. Make L&T/Havells/CG.
Labour for cutting/ trimming of tree branches up to 80mm thickness along the alignment of LT /HT over head electric line which are going/ touching or falling or ACSR conductor/ poles or near by sub stns etc at any height from GL and making ta leastlearance 1.5m form conductor and removing to a distance up to 100 mtr where directed by Engineer-In-Charge. Note:- (i) Trimming of the branches on one sides of the conductor. (ii) actual length of cutting will be measured. (iii) The distance as motioned above will be maintained during contract current period & same location subject to at least 6 months period between two trimming/leaping. (iv) Measurement will be taken including all conductor as one only.
Earthing complete with galvanised steel earth plate electrode 600 X 600 X 6mm thick buried directly in ground vertically to a depth not less than 2.25 meters deep below ground level with top edge of the earth plate not less than 1.5 meters deep below normal ground level, connected with and including galvanised iron strip of size 25 x 4mm connected to main test point as directed as earthing lead by means of nuts, bolts and washers of galvanised iron protected by 40mm dia (medium grade) GI tubing, funnel, wire mesh, 20mm bore GI tubing (light grade) watering pipe, including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:2:4) type B-1 cover slab of size 350 x 350 x 50mm reinforced with 8mm dia TMT bars @ 15cm c/c in both ways and 10mm dia MS handle (01 No) of suitable size for lifting of cover slab, charcoal and salt in alternate layers including necessary excavation and earth work in soft/loose soil all as shown in Electric plate No 3 of SSR Part-I and testing on completion complete all as specified and directed by Engr-in-Charge.
Taking out old US MCCB at site and making good disturbed surfaces etc complete all as specified and directed.
Supply & fix in replacement of MCCB, 4 pole, 100 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 25 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge. (Make :- L&T Cat No.CM90642OOLO or equivalent to Havells / Schneider.
Supply & fix in replacement of MCCB, 4 pole, 160 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 25 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge. (Make :- L&T Cat No.CM90642OONO or equivalent to Havells / Schneider.
Supply & fix in replacement of MCCB, 4 pole, 200 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge. (Make :- L&T Cat No.CM90642OONO or equivalent to Havells / Schneider..
Supply & fix in replacement of MCCB, 4 pole, 250 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge. (Make :- L&T Cat No.CM90642OOPO or equivalent to Havells / Schneider.
Supply & fix in replacement of MCCB, 4 pole, 400 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge. (Make :- L&T Cat No.CM98403OOROOG. or equivalent to Havells / Schneider.
Taking out old US/damaged LT Panel at site and making good disturbed surfaces etc complete all as specified and directed.
Ajanta Motor Store
Hindustan Power Corporation
His And Her Enterprises
Unnati Engineers
M/S AVADH ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .