| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | ₹17.7 L Quoted ₹18.2 L | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹18.3 L+₹12,560 (0.69%)Rejected-Finance | ₹18.3 L+₹12,560 (0.69%) | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹18.9 L+₹72,640 (3.99%)Rejected-Finance 39 SR LAYOUT MAIN ROAD NAL WING TUNNEL ROAD MURUGESH PALYA BANGALORE 560 017 | BENGALURU URBAN | KARNATAKA | 560017 | ₹18.9 L+₹72,640 (3.99%) | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹19.0 L+₹74,200 (4.07%)Rejected-Finance | ₹19.0 L+₹74,200 (4.07%) | L4 | Rejected-Finance Not Being L1 |
| 5 | L5₹19.1 L+₹85,350 (4.68%)Rejected-Finance | ₹19.1 L+₹85,350 (4.68%) | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
27 May 2023, 6:00 pmClosed
GARRISON ENGINEER CENTRAL BANGALORE
ASC CENTER AND COLLEGE AGRAM POST BANGALORE -560007
REPAIR MAINTENANCE OG BLDG EARTHING SYSTEM AND MISC ITEMS UNDER GE CENTRAL BANGALORE
2023_MES_593232_1
8292E
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GARRISON ENGINEER CENTRAL BANGALORE
Please refer tender documents
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER CENTRAL BANGALORE
₹40,000
Yes
5 Aug 2023
4 May 2023
29 May 2023
4 May 2023
27 May 2023
15 May 2023
4 May 2023 - 13 May 2023
Amount
M&L for air termination, single pointed, Aluminium rod 12 mm dia and 300 mm long including taking out/dismantling old air termination rod
M&L for earth continuity conductor or main earthing lead 32x6 mm GI strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation all as directed by Engineer-in Charge complete including insulators riveting and soldering or brazing including taking out/down /dismantling old earth continuity conductor.
All same as per item No 2 here-in-above but 25 x 3 mm Almunium strip -do-
S&F test point terminal block made out of Gun metal or phosphorous bronze of size 75x75x25mm thick with arrangement by making 12 Nos. holes suitable for and including 12 Nos 8mm dia 25mm long bolts and nuts hexagonal head including taking out/down/dismantling old test point terminal block
M&L for Earthing with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized iron earth wire 4 mm dia as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted to earth plate at one end and other end of earth wire connected to Pole / transformer / GOD / Panel / equipment body / test point, GI earth wire encased in and including 15mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed including taking out old earthing.. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner
M&L for Earthing including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 25x4 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected to test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed including dismantling & taking out old existing unserviceable earthing including taking out old earthing. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
S & F in repairs GI protection pipe 50 mm dia light grade cut to size & fixed in any description such as in roof etc for passing of Air termination rod fixed in MS clamps of size as orderd complete all as directed.
B5BUILDING SOLUTIONS
GKR and CO
SREE VARU ELECTRICALS
RAMSON TRADERS
M/S - KRUPA ELECTRICALS
SREE BALAJI CONSTRUCTIONS
M/S Jaiprakash Electrical and Engineering Works
kamadhenu Electricals
M.G. Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .