Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.5 LAccepted-AOC NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | ₹39.5 L Quoted ₹40.3 L | L1 | Accepted-AOC L1 |
| 2 | L2₹44.1 L+₹3.8 L (9.34%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | ₹44.1 L+₹3.8 L (9.34%) | L2 | Rejected-Finance OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹97,000
Closing Date
6 Oct 2022, 6:00 pmClosed
GE (UTILITIES)
GE (UTILITIES) UDHAMPUR, PO-GARHI, PIN-182121
Repair/Maint of DG Sets, feeder boxes, UG cable, street security lights and connected items in certain different locations under GE (Utilities) Udhampur.
2022_MES_550672_1
GE/U-43/20222-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (UTILITIES) UDHAMPUR
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE (UTILITIES) UDHAMPUR
₹97,000
Yes
6 Dec 2022
8 Sept 2022
8 Oct 2022
8 Sept 2022
6 Oct 2022
22 Sept 2022
Amount
Dehydration including filtration and cleaning of Voltage stabilizer oil by dehydrating machine including testing of sample before and after dehydration and filteration and replacement of silica gel all as specified and directed by Engr-in-Charge. Note:- Dehydration machine and testing kit will be provided by the Department but transpotation of machine is the responsibility of Contractor without any extra cost to the dept. Sample testing will be carried out in the presence of Engr-in-Charge on site.
Pouring of up to the appropriate level Voltage stabilizer oil of low viscosity having dielectric strength not less than 60 KV complete all as specified and as directed by Engr-in-Charge. Note:- Dielectric strength test shall be carried out at site before poring/filling in transformers in the presence of Engr-in-Charge on the site responsibility of Contractor without any extra cost to the deptt. Sample testing will be carried out in the presence of Engr-in-Charge on site.
Defect rectification of LT 1.1 KV cable laid in trenches by locating fault with help of electronic fault locating machine comprising of surge generator pules, ECHO fault locator with high frequency distance calculator for cable of any size XLPE 11 KV / 1.1 KV complete all as specified and directed by Engr-in-Charge.
Supply, jointing and testing Straight through cable joint heat shrinkable including all material and accessories suitable for 4 core X 25-95 Sqmm XLPE cable of 1100 volts (E)grade complete all as specified and directed by Engr-in-Charge. Note : Cost of Prepration of existing end deemed to be included in unit rate.
All as per item No 4.00 here-in-before but of size 3.5 core X120sqmm - 185 sqmm.
All as per item No 4.00 here-in-before but of size Above 3.5 core X185sqmm.
Comprehensive maintainance of oil cooled servo voltage stablizers of following capacities by isolating ,disconnecting of input/output ,supply cable,opening of top of voltage stablizers,detecting of fault ,u/s component in control panel /dimmerstat /PCB etc,cleaning of serviceable parts/ component ,including preparation of old painted surface of steel surface by brushing /cleaning strain grease /oily spots with tinner and two coats of spray painting with spray machine & replacement of worn out spare parts etc, if required complete all as specified and directed by Engr-in-Charge:-
Voltage stablizer of capacity 600 KVA three phase.
Voltage stablizer of capacity 400/450 KVA three phase.
Voltage stablizer of capacity 250/200 KVA three phase.
Voltage stablizer of capacity 100 KVA three phase.
Micro Processor based control card for each phase.
Servo synchronizing motor single phase AC 230 Volts, 3 Kg torque.
RC Net work for 3 Kg torque servo motor.
Carbon Brush of any capacity.
Dismantling existing ACSR conductor of any size/type from PCC/Steel poles including taking down MS works such as cross arms, clamps, hooks, stay etc from overhead line complete all as specified and directed by Engr-in-Charge.
Taking down/Removing existing PCC/Steel poles from site complete all as specified and directed by Engr-in- Charge. Note: Damaged poles shall be removed from site.
Taking down existing old cross arms of MS channel or angle sections etc complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable insulators any type and size from poles including for reuse or removal complete all as specefied and directed by Engr-in-Charge.
Lighteneing arrestors (in replacement) expulsion type complete with all fittings, suitable for 11000 Volts grade transmission class, discharge capacity 65KA including brackets, clamps, nuts, washers and connecting to 4mm dia GI earth wire complete all as specified and directed by Engr-in-Charge.
Aluminium conductor steel reinforced (ACSR) any size on poles, stretched on LT poles without any kink and bends of various sizes complete including fixing to insulator with Aluminium binding wire complete all as specefied and directed by Engr-in-Charge.
11000 volts grade disc type insulator porcelain vitreous 145mm heigh 255mm dia ball and socket type white or brown or green with tension clamps complete all as specified and directed by Engr-in-Charge .
Pin type porcelain vitreous white or brown or green insulator including one galvanized mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and directed by Engr-in-Charge.
MS Channel/angle iron/flat iron (in replacement ) of required size and bend to shape as cross arms, bracing and support including, MS clamps back plates with bolts, nuts, and washers drilled for insulators including painting two coats of synthetic enemel paint (Aluminium shade) over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
Steel tubular swaged poles erected to truly vertical or planted as strut complete with 6mm thick mild steel base plate(300mmx300mm), welded to pole, finial taper plug, bolts, nuts, and screws poles made out of ERW MS tubing conforming to IS-2713 Part-II Type 410 SP-55, 11.0 mtr long including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bitumenous paint internally and portion embedded in concrete, making five black & white bands at lower portion of pole each 300mm wide alternately upto the height and marking pole No. with black paint at suitable height including making two nos holes of suitable size in steel tubular pole by gas welding for passing PVC cable connection from junction box to security lights through pole where junction box to be fitted in pole, complete all as specified and directed by Engr-in-Charge. Note: Cost of Excavation, Earth Work and PCC in foundation are deem to be included in quoted rate.
MCCB 4 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA camplete all as specified and directed by Engr-in-Charge.
MCCB 4 Pole, 415 V, fixed type, 125 Amps with breaking capacity 16 KA camplete all as specified and directed by Engr-in-Charge.
MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA camplete all as specified and directed by Engr-in-Charge.
MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA camplete all as specified and directed by Engr-in-Charge.
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed by Engr-in-Charge.
Earthing complete (in replacement) with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 32 x 6mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common salt including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40x40x5mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 40 mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by Engr-in-Charge.
Note: - (i)On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge. (ii) Item includes the cost of 7.5 m GI pipe for protection of earth strip. (iii) PCC pits extra cost of addtional length of watering pipe, bends elbows etc.shall be deemed to be included in the quioted rate. (iv) Item includes the cost of 7.5 mtr length copper earth strip 25x3 mm.
Earth continuity conductor or main earthing lead fixed to wall on batton or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to pole or any other (in replacement) indicated situation for loop earthing etc as required with 32x6mm galvanised iron strip complete all as specified and directed by Engr-in-Charge.
LED Decorative Garden/post-top light for 360 degree indirect light IP-65 grade of proterction with High power LED of 10 watt (in replecement) with resistance to impact and corrosion. Glare free and better uniformity.Milky version .complete all as specified and as directed by Engr-in-Charge. Make:- Cat Part No. LBLS1-10 of CG CDL/ CG or its equivalent in Wipro/Phillips/Havells. Note : Foundation for fixing Garden light/Post top light shall be deemed to be included in the rates quoted by the Contractor.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled, screwed including 3 nos. 8mm dia 25mm long hexagenal head screw & brezing all joints complete all as specified and directed by Engr-in-Charge.
Taking down GI strip/ Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and as directed by Engr-in-Charge.
Taking down test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagenal head screw complete all as specified and as directed by Engr-in-Charge.
Disconnecting the bindings of loose overhead conductor of LT/HT lines from insulators and restringing the same for proper sag and rebinding with new aluminium binding wires at insulators, making all jumpers and inter connections of conductors at cut points as well as turnings using PG clamps of suitable size as per size of conductor for any type of conductor including restringing of continuous GI earth wire complete all as specified and directed by Engr-in-Charge. Note :- (i) Trimming of tree branches upto 3 m all around the conductors is deemed to be included in the rates quoted. (ii) Three ACSR conductors and two GI earth wire will be measured as one unit length for payment. (iii) Cost of PG clamps, aluminium winding wire and eye hook for GI earth wire are included in the rates coated for restringing.
Lead acid maintenance free Battry 12 Volts 180 AH (in replecement) of existing type & size complete all as specified and directed by Engr-in-Charge . Make : EXIDE/AMCO/AMRON including initial charging.
160 Amp, 415 Volts, 50 Hz Power contactor of coil voltage 240 Volts(in replecement), complete all as specified and directed by Engr-in-Charge. Make: L&T/Schineider/Havells.
LED indicator lamp for LT/HT panel (Red / Green/Blue/Yellow) complete all as specified and directed by Engr-in-Charge.
Multi function meter input 3 Phase 4 Wire, Voltage Range 300V AC (L-N)/520V AC(P-P), Display Paremeter : Voltage (p-p) (P-L), Amp (R,Y,B) Current : 0-5A , CT 05-6000A installed on LT panel including necessory wiring, CT of required size complete all as specified and directed by Engr-in-Charge. Make: Multispan Cat Pat No. AVF-19N or equIvalent in Schneider, L&T.
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 3.5 core X 300Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed by Engr-in-Charge.
All as per item No 37.00 here-in-before but of size 3.5 core X 185 sqmm.
All as per item No 37.00 here-in-before but of size 3.5 core X 120 sqmm.
All as per item No 37.00 here-in-before but of size 3.5 core X 95 sqmm.
All as per item No 37.00 here-in-before but of size 3.5 core X 50 sqmm.
All as per item No 37.00 here-in-before but of size 3.5 core X 35 sqmm.
All as per item No 37.00 here-in-before but of size 4 core X 25 sqmm.
Excavation in trenches not exceeding 1.5 m wide and and not exceeding 1.5 m depth in Hard/dense soil and getting out complete all as specified and directed by Engr-in-Charge.
Returning, filling in, with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed by Engr-in-Charge.
Removal of surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed by Engr-in-Charge.
DWC ( Double wall corruated ) pipe 120 x 103 mm conforming to IS 14930/ IS 16205 for protection of LT / HTCable of size 95 sqmm including neccesory Snap-Fit cuppler required for fixing complete all as specified and directed by Engr-in-Charge.
All as per serial item No 47.00 here-in-before but of size 90/76 mm for XLPE cable 3.5 core X 95 sqmm.
All as per serial item No 47.00 here-in-before but of size 77/63 mm for XLPE cable 3.5 core X 70 sqmm-10 smmm.
Taking down the existing cables from trenches of any size complete all as specified and directed by Engr-in-Charge.
Supply ,installation ,testing and commissioning (in replacement) of feeder pillar board Kiosk type ,LT(415 Volts, 50 Hz , 3-phase, 4 wire supply) floor mounted , factory assembled, outdoor type weather and vermin proof (Protection Class IP-54) made out of 40m x 40mm x 6mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet with front hinged opening, rubber lining, locking arrangement ,powder coated externally and internally after seven tanks treatment and lifting channel, fully compartmentalized design complete Bus Bar chamber comprising incomer MCCB 315 Amp, 4 Nos aluminium strip bus bars air insulated and PVC sheathed capacity 400 Amps with colour coding complete all as specified and as directed by Engr-in-Charge.
Preparation of old painted steel surface by brushing /cleaning strain grease /oily spots with thinner and two coats of spray painting with spray machine to LT panel board ,Bus bar Chamber ,feeder pillar box, load line DB and power factor panel etc including disconnecting of all incoming and out going cables and re connecting after painting. complete all as specified and directed by Engr-in-Charge.
On load change over switch FP 400 Amps, front handle, 415 Volt, 4 pole 50 Hz, including neccesory addition / altration in panel for mounting and providing Busbar, Nut bolts & Washers complete all as directed by Engr-in-Charge.
On load change over switch FP 200 Amps, front handle, 415 Volt, 4 pole 50 Hz, including neccesory addition / altration in panel for mounting and providing Busbar, Nut bolts & Washers complete all as directed by Engr-in-Charge.
170/160 Watt LED Flood light ( in replacement) with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 110 lumen/Watt (Minimum lumen output of luminarie should be 16500 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specified and directed by Engr-in-Charge.
All as per item No 55.00 but LED Flood light of 120 watt capacity.
All as per item No 55.00 but LED Street light of 90 watt capacity.
All as per item No 55.00 but LED Street light of 60 watt capacity.
Inverter based 90 Watt LED steet light (in replacement) with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 110 lumen/Watt (Minimum lumen output of luminarie should be 16500 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have inbuild maintenance free rechargable battery of min 2AH and AC DC adaptor of apropriate confrigation complete all as specified and directed by Engineer-in-Charge.
Bracket for street light fitting made of 40mm bore light grade GI tube bent to shape required, Sutable for fixing on pole including fixed with bolts, nuts, washers duly painting the bracket with two coats of aluminium paint over a coat of zinc chrome primer complete including taking down the existing bracket and refixing and connecting up the light fitting etc complete all as specified and directed by Engr-in-Charge.
Supply, laying and testing (in replacement ) cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 3.5 core x 70 Sq mm. complete all as specified and as directed by Engr-in-Charge. Note : Provision of suitable double crimpped lugs and glands deemed to be included in quoted rates.
All as per item No 61.00 here-in-before but of size 4 core 25 sqmm.
All as per item No 61.00 here-in-before but of size 4 core 16 sqmm.
Wiring with Three run single core PVC insulated, stranded, PVC sheathed copper cable conductor size 1.5 Sqmm x 3 core and drawing through pole including connected to street light & earth dolly complete all as specified and directed by Engr-in-Charge.
Automatic timer switch (in replacement) pole mounted enclosure consisting of ON/OFF switch based on LUX level, power contactor 40 Amps, 4 pole, MCB 40 Amps, TP - 03 Nos, enclosure made of rust proof, shock proof, conforming to IP -54 complete all as specifid and directed by Engr-in-Charge. Make : Kakatiya/Healer/Bajaj. Note: (i) Inlet/outlet connecting cable PVC insulated aluminium stranded conductor 6 Sqmm, 4 single core for incoming & outgoing up to 8 Mtr deemed to be included in the unit rate. (ii) Provn of glands and lugs shall be deemed to be included in the quoted rate.
Taking down carefully old unserviceable Street light/Security light/High Mast light fitting from pole/Structure and repair/replacement of worn out part such as Driver,cleaning of fittings,cover,copper wire,clamps ,nuts and bolts, mounting bracket and re assembling the same after repair,testing and refixing in pole/other location including provision of necessery T & P like ladder/Boom Vehicle, tools ets as required for taking down and refixing of street light complete all as specefied and directed by Engr-in-Charge. Note : Replacement of defective spare parts of fitting (to make functional ) will be measured and paid separately as supply only. However, cost of replacement screws, nuts, bolts, and cleaning of fittings shall be deemed to be included in quoted rate.
MCB 4 Pole, 415 V, fixed type, 32Amp with breaking capacity 16 KA complete all as specified and directed by Engr-in-Charge.
MCB 4 Pole, 415 V, fixed type, 63Amps with breaking capacity 16 KA complete all as specified and directed by Engr-in-Charge.
Driver for LED energy saving & enviornment area light fitting > 90 watts security light (in replacement) with active power factor correction (APFC) electronic driver. LED driver 90 Watt with operating voltage between 100-270 V of existing complete all as specified and directed by Engineer-in-Charge.
All as item No 69.00 here-in-before but for LED Street light 60 watt capacity.
Supply and installation (in replacement) Hot dipped Octagonal galvanized iron pole 8 mtr height, with necessary Foundation RCC 1:1:5:3 with 8Nos 16 mm dia tor bar as main bars and 8mm dia Tor bars strips@190mm c/c as this reinforcement shall conform to IS : 1786 latest edition.The foundation shall extend above surroundings ground/drive way level for 200 mm and have DWC 63 mm dia,PVC sleeve cast foundation for cable entry,Excavation,RCC and reinforcement etc as per manufacturer recommendation and the cost of necessary foundation , steel bars , strip as per Manufacturer instructions complete all as specified and directed by Engr-in-Charge.
Single arm bracket 1000 mm long made of 48mm OD pipe on pole of 8 Mtr height complete all as specified and directed by Engr-in-Charge.
Double arm bracket 1000 mm long made of 48mm OD pipe on pole of 8 Mtr height complete all as specified and directed by Engr-in-Charge.
Supply and Laying (in replacement) Galvanised iron steel tubes, ISI marked light grade of size 40 mm bore for cable protection along the poles under road under drains, laid in trenches/fixed on walls/poles with suitable clamps bolts nuts etc including taking down of old unserviceble pipe , complete all as specified and directed by Engr-in-Charge.
Cleaning the existing exposed surfaces of steel tubular pole of 9.0 mtr long including cross arms, brackets, clamps etc and painting with two coats of aluminium paint marking five black & white bands at lower portion of pole, each 300 mm wide alternately and marking pole No. with yellow paint on black base at suitable height complete all as specified and directed by Engr-in-Charge.
Cleaning the existing exposed surfaces of steel tubular/PCC pole of 11.0 mtr long including cross arms, brackets, clamps etc and painting with two coats of aluminium paint marking five black & white bands at lower portion of pole, each 300 mm wide alternately and marking pole No. with yellow paint on black base at suitable height complete all as specified and directed by Engr-in-Charge.
PVC sheathed Twin core Aluminium conductor (in replacement) cable 6 sqmm complete all as specified and directed by Engr-in-Charge.
PVC sheathed Twin core Aluminium conductor (in replacement ) cable 4 sqmm complete all as specified and directed by Engr-in-Charge.
Weather proof street light junction box of size 300 x 200 x 105mm including MCB SP 6 Amps and connecting terminals 4 way and fixing with street light poles using necessary MS clamps, nuts, bolts washers, lugs for incoming and out going cables, gland for cable etc of suitable size complete all as specified and directed by Engr-in-Charge. Make : Hensel/Sintex/Universal Switch Gear control. Note : The rates quoted are inclusive of provision and fixing of suitable lugs and glands for cable connection.
Carry out servicing from authorised rep or service engineer from the manufacturer of DG set of 320 KVA,capacity complete all as specified and directed by Engr-in-Charge. Make : Cummins all as per OEM instructions and directed by Engineer in Charge . Note : All the spare , parts , lubrication oil etc. has been measured and paid saperatly under respective item of schedule 'A' (BOQ).
All as per serial item No. 80.00 here-in-before but of size for DG set 320 KVA. Make: MWM
All as per serial item No.80.00 here-in-before but of size for DG set 250 KVA. Make: Cummins
All as per serial item No.80.00 here-in-before but of size for DG set 125 KVA. Make: Cummins
All as per serial item No.80.00 here in before but of size for DG set 100 KVA. Make: Kirloskar
All as per serial item No.80.00 here in before but of size for DG set 160 KVA. Make: MWM
All as per serial item No.80.00 here in before but of size for DG set 62.5 KVA. Make: Kirloskar
All as per item No.80.00 here in before but of size for DG set 15 KVA. Make: Kirloskar
Supply only fuel filter primary and secondary suitable for DG Set capacity 250KVA to 320KVA complete all as specified and directed by Engr-in-Charge. Make:Cat Part No : FS19634 of Feelgaurd or equivalent in Cummins .
Supply only lub oil filter body suitable for DG Set capacity 250KVA to 320KVA complete all as specified and directed by Engr-in-Charge. Make: Cat Part No.LF9009 of Feelgaurd or equivalent in Cummins.
Supply only Air cleaner element suitable DG Set for capacity 10KVA to 320KVA complete all as specified and directed by Engr-in-Charge. Make: Cat Part No.AF 26093 of Feelgaurd or equivalent in Cummins.
Supply only inner Air cleaner element suitable DG Set for capacity 10KVA to 320KVA complete all as specified and directed by Engr-in-Charge. Make: Cat Part No.AF 25911 of Feelgaurd or equivalent in Cummins.
Supply only water filter body suitable for DG Set capacity 250KVA to 320KVA complete all as specified and directed by Engr-in-Charge. Make: Cat Part No. 04.270.01.0 of kirloskar or equivalent Bosch.
Supply only fuel filter primary and secondary suitable for DG Set capacity 250KVA to 320KVA complete all as specified and directed by Engr-in-Charge. Make : Cat Part No : F002H20 306 of Bosch or equivalent kirloskar .
Supply only lub oil filter body suitable for DG Set capacity 250KVA to 320KVA complete all as specified and directed by Engr-in-Charge. Make:Cat Part No.06.436.01.0 of kirloskar or equivalent Bosch.
Supply only Air cleaner element suitable DG Set for capacity 10KVA to 320KVA complete all as specified and directed by Engr-in-Charge. Make: Cat Part No. 04.586.01000 of kirloskar or equivalent Bosch.
Supply and filling coolent for radiators. K Cool super Plus -50-50 premix.Cat part No.82.020.35.1.25. 25ltrs Packing complete all as specified and directed by Engr-in-Charge.
Replacement of Solenoied switch sutaible for 320 KVA DG Set complete all as specified and directed by Engr-in-Charge.
Replacement of water circulating pump, for DG set of capacity 320 KVA including air supply connection pipe, clip, replacement of repair kit, calibration/ testing system complete, fitted with DG set properly in original position, checking the allignment, making proper all connection, testing for smooth opreation from authorised rep or service engineer from the manufacturer complete all as specified and directed by Engr-in-Charge.
Control wiring for connecting all safety to controller/ AMF panel of 250 KVA DG set and 320 KVA DG set carrying out complete servicing control panel, including checking and rewiring electrical circuit using FRLS copper conductor, for DG Set of any type / make / capacity, making all electric connections and testing for smooth operation, complete all as specified and directed by Engr-in-Charge.
Replacement of low level water safety relay for DG set of capacity upto 320 KVA of any make complete all as specified and directed by Engr-in-Charge.
Replacement of over heat safety relay for DG set of capacity upto 320 KVA of any make complete all as specified and directed by Engr-in-Charge.
Replacement of Temprature Gauge for DG set of capacity 320 KVA of any make complete alll as specified and directed by Engr-in-Charge.
Replacement of RPM meter for DG set of capacity 320 KVA of any make complete all as specified and directed by Engr-in-Charge.
Replacement of Solenoied switch suitable for 250 KVA DG Set complete all as specified and directed by Engr-in-Charge.
Replacement of Ring gear of Flywheel suitable for DG set up to 320 kva complete all as specified and directed by Engr-in-Charge.
AVR S/F VARIABLE SPEED DCDG (in replacement) suitable for DG set with input voltage range 415 Volt AC with neutral & Out put DC voltage suitable for DG set upto 100 KVA complete all as specified and directed by Engr -in-Charge.
AVR S/F VARIABLE SPEED DCDG (in replacement) suitable for DG set with input voltage range 415 Volt AC with neutral & Out put DC voltage suitable for DG set above 125 KVA to 320 KVA complete all as specified and directed by Engr-in-Charge.
Supply, Fix and test run the DG set after replacing Diesel feeder Pump of existing model,size suitable for DG Set of capacity 15 to 320 KVA including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge.
Drain out the fuel from the fuel tank of DG set of any size/capacity and keeping it in separate container safely, disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank for cleaning, internally and externally by removing all the accumulated dirt/ sediment, leak testing the tank and welding/ brazing including one coat of synthetic enamel paint, refixing the tank in its original position, replacing the drain plug and PVC pipe, calibrating the fuel tank, refilling the drained out fuel back into the tank and marking of liters in gauge and provision of locking arrangements complete all as specified and directed by Engr-in-Charge.
Disconnected and opening of self starter assembly 12/24 volt for repair from DG set up to 320 KVA & repair unserveceable part of self starter suitable size as required on site complete all as specified and directed by Engr-in-Charge. Note :- Rate are deemed to be included all worn out parts including gear & winding.
Supply only the following items of DG Set of various capacity :-
Battery terminal, lug, bolts type suitable for heavy duty battery.
Battery leads for copper conductor multiwired 50 Sqmm Single Core.
Hinges for DG set door of any size, any type as required on site.
Supply and topping up of distilled water suitable for lead acid batteries of 12 volts complete all as specified directed by Engr-in-Charge.
Replacement of Lub oil pipe suitable for DG Set capacity 15KVA to 320KVA complete all as specified and directed by Engr-in-Charge. Make: Cat Part No.02.078.05.0.00.of Kirloskar or equivalent.
Replacement of tappet valve suitable for DG Set of capacity 15KVA to 320 KVA complete all as specified and directed by Engr-in-Charge. Make: Cat part No.181027 of Greaves or equivalent.
Replacement of Fuel Pipe for filter (7.5,14x14B,700PB) for BIO Diesel suitable for DG Set of capacity 15KVA to 320KVA complete all as specified and directed by Engr-in-Charge. Make: Cat Part No.02.102.03.0.00 of Kirloskar or equivalent.
Replacement of Fuel Pipe return ( FIP TO TANK) for BIO Diesel suitable for DG Set of capacity 15KVA to 320KVA complete all as specified and directed by Engr-in-Charge. Make:Cat Part No.02.102.13.0.00.of Kirloskar or equivalent.
Replacement of Residential Silencer suitable for DG Set of capacity upto 320KVA complete all as specified and directed by Engr-in-Charge. Make: Cat Part No.02.538.10.0.00 of Kirloskar or equivalent.
Supply only of engine oil 15 W 40 in sealed Packing complete all as specified and directed by Engr-in-Charge. Make: Castrol Super /valvolinre or equivalent .
Replacement of three phase Digital Voltmeter 0-500V AC complete all as specified and directed by Engr-in-Charge. Make : Schneider or equivalent in Havells size as per site requirement.
Replacement of three phase Digital Ammeter 30/5A(CTR) complete all as specified and directed by Engr-in-Charge. Make: Schneider or equivalent in Havells size as per site requirement.
Dismantling existing U/S battery charger & S/F of SMPS type battery charger suitable for 12 V DC with auto cut off from trickle to boost alongwith AC lead to charge the battery when DG Set is not in use complete all as specified and directed by Engr-in-Charge.
Replacement of V belt for fan pulley (set of 2Nos) for DG set upto 320 KVA DG Set complete all as specified and directed by Engr-in-Charge.
Replacement of V belt for alternator and water pump assembly for DG set upto 320 KVA complete all as specified and directed by Engr-in-Charge.
Carrying out complete overhauling / servicing of DG set panel / AMF panel / control panel, including checking and rewiring faulty electrical circuit using 2.5 sqmm FRLS copper conductor, for DG Set of any type / make / capacity, making all electric connections and testing for smooth operation, complete all as specified and directed by Engr-in-Charge.
Under/over voltage relay, 3 phase, 415 volts', for DG sets of capacity upto 320 KVA complete all as specified and directed by Engr-in-Charge.
Battery voltage relay 12 VDC (in replacement) complete all as specified and directed by Engr-in-Charge.
Battery 12volt 65/75 AH Code :- EP.15-12(12M15) ( in replacement) complete all as specified and directed by Engr-in-Charge. Make:- Exide/Amron/AMCO.
600 Amp, 4 pole, 415 Volts, 50 Hz Power contactor (MCX45), auxilary contact 2 NO + 2 NC, of coil voltage 240 Volts (in replacement), complete all as specified and directed by Engr-in-Charge. Make: Model No CS 97027 L&T/Schineider/Havells.
160 Amp,4pole, 415 Volts, 50 Hz Power contactor (MNX140) auxilary contact 2 NO + 2 NC, of coil voltage 240 Volts ( in replacement ), complete all as specified and directed by Engr-in-Charge. Make: Model No CS 94139 L&T/Schineider/Havells.
400 Amp,4pole, 415 Volts, 50 Hz Power contactor (MCX43) auxilary contact 2 NO + 2 NC, of coil voltage 240 Volts (in replacement ), complete all as specified and directed by Engr-in-Charge. Make: Model No CS 97025 L&T/Schineider/Havells.
Electronic Microprocessor based controller unit suitable for DG set controlls & commands of 62.5 KVA capacity (in replacement ) with all listed parameters as per recomendation including testing complete all as specified and directed by Engr-in-Charge. Make: 934 V2 Koel Green Gen Set.
Electronic Microprocessor based controller unit suitable for DG set controlls & commands capacity upto 250 KVA DG set (in replacement ) with all listed parameters as per recomendation including testing complete all as specified and directed by Engr-in-Charge. Make: Cummins
Supply and laying in trenches/wall/air armoured cable 1100 Volt multi stranded copper conductor cable of size 2.5 sqmm X 8 core for connection of AMF panel to DG set complete all as specified and directed by Engr-in-Charge.
Attending of any breakdown of standby supply in any location ,whenever required round the clock ,rectify the fault and restore the standby supply within three hour after receipt of complaint of any nature i.e. Engine, alternator,control panel,AMF panel etc complete all as specified and directed by Engr-in-Charge. Note -(i) The cost of replaced spare parts will be paid and measured seperatly. (ii) If complaint is not attended by contractor with in five hour the penality of Rs 500 / per hour to be imposed and amount of penality will be deducted from RAR. (iii) The cost of transportation (to and fro) for all kind of necessary equipment / T&P shall be arranged/brought by contractor to complete the job at site or at E/M yard and no extra cost shall be paid to the contractor to this effect. (iv) Complaint shall be lodged by telephonically ,so contractor to specify the telephone no who will receive the complaint round the clock.
Opening / taking out of injector of DG set of any type/make and capacity 15 KVA to 320 KVA disconnection and opening of fuel injector assembly, carrying complete overhauling/servicing fuel injection system with including replacement of injector repair kit ,including calibration of injector, checking of pressure complete for each injector and re-assembling the same, fitted with DG set properly in original location, checking the allignment, making proper fuel connection, testing for smooth opreatio complete all as specified and directed by Engr-in-Charge.
Unserviceable thermostat (in replacement ) with new thermostat alongwith complete assy for DG set connection testing complete all as specified and directed by Engr-in-Charge.
Complete overhauling,servicing of turbo charger, opening /taking out of turbo charger of DG set of 15 KVA to 320 KVA capacity ,disconnection of air supply connection pipe etc, including replacement of turbo charger repair kit, calibration/ testing of turbo charger system complete and re-assembling the same ,fitted with DG set properly in original position, checking the allignment, making proper all connection, testing for smooth opreation from authorised rep or service Engineer from the manufacturer complete all as specified and directed by Engr-in-Charge.
Turbo charger, for DG set of capacity 320 KVA including air supply connection pipe, clip, replacement of turbo charger repair kit, calibration/ testing of turbo charger system complete, fitted with DG set properly in original position, checking the allignment, making proper all connection, testing for smooth opreation from authorised rep or service engineer from the manufacturer complete all as specified and directed by Engr-in-Charge.
Capacity 15 to 320 KVA complete descaling of cooling system by radiwash with two times circulation of radiwash by means of running of engine & cleaning of fan blades, crankcase breather, radiator and its fins by means of high pressure air or water complete all as specified and directed by Engr-in-Charge.
Replacement of Copper tube (Thimbles) terminal heavy duty of size 185 Sqmm complete all as specified and directed by Engr-in-Charge.
Replacement of Copper tube (Thimbles) terminal heavy duty of size 150 Sqmm complete all as specified and directed by Engr-in-Charge.
Replacement of Copper tube (Thimbles) terminal heavy duty of size 120 Sqmm complete all as specified and directed by Engr-in-Charge.
Replacement of Copper tube (Thimbles) terminal heavy duty of size 95 Sqmm complete all as specified and directed by Engr-in-Charge.
Replacement of Copper tube (Thimbles) terminal heavy duty of size 70 Sqmm complete all as specified and directed by Engr-in-Charge.
Main switch with sheet steel enclosure 400 amps TPN, 415 volts with HRC/ re-wireable fuses complete all as specified and directed by Engr-in-Charge. Make :- HPL/Havelles/C&S.
Change over switch FP 200 Amps, side handle, 415 Volt (in replacement) 4 pole complete all as specified and directed by Engr-in-Charge. Make:-HPL/L&T/Havelles.
Change over switch FP 400 Amps, side handle, 415 Volt, 4 pole complete all as specified and directed by Engr-in-Charge. Make :-HPL/L&T/Havelles/C&S.
Single core, copper cable,70 sqmm, 1100 Volt suitable (in replacement) for existing DG set including propper connection from DG set to AMF Panel / Changeover complete all as specified and directed by Engr-in-Charge.
Supply and laying in trenches/wall/air XLPE armoured under ground cable 1100 Volt multi stranded aluminium conductor of 300 Sq mm 3.5 core (excavation and earth work will be measured and paid seperately) complete all as specified and directed by Engr-in-Charge. Make: Havells/Kalinga/Paragon.
All as per serial item No 151.00 here-in-before but of size 240 Sq mm 3.5 core.
All as per serial item No 151.00 here-in-before but of size 500 Sq mm single core.
Replacement of gasket for cyl head 1.22mm thick cat part No 6H 007.06.0.00 of Kirloskar or equivalent as per model complete all as specified and directed by Engr-in-Charge.
MOHAN LAL AND SONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .