| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 CrAccepted-AOC | ₹7.0 Cr Quoted ₹7.2 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹7.6 Cr+₹44.1 L (6.12%)Rejected-AOC BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | ₹7.6 Cr+₹44.1 L (6.12%) | L2 | Rejected-AOC OTHER THAN LOWEST |
| 3 | L3₹8.6 Cr+₹1.4 Cr (19.6%)Rejected-AOC | ₹8.6 Cr+₹1.4 Cr (19.6%) | L3 | Rejected-AOC OTHER THAN LOWEST |
| Sl No | Description | Qty | Unit | AGRAWAL ASSOCIATES L2 | HI TECH COLONISERS PRIVATE LIMITED L1 | Shetty Construction Co L3 |
|---|---|---|---|---|---|---|
| 1.00Notes : 1) The rates of below items includes necessary barricading of MS sheet upto 3 m ht around the bldg before carrying out repair works, and all safety measures including safety harnesses for working upto 9 th floor. 2) Work shall be executed as per Structural Audit report for reference (Copy of Structural report available with GE Office) 3) Rate shall be inclusive of steel scaffolding, No payment shall be made for scaffolding separetely in respective items. | ||||||
| 2.00 | Material & Labour for Relieving Structural members such as column, beam and slabs of their superimposed loads partially or fully by provision of adjustable steel props, frames etc. including providing necessary timber runners, bracing, jacking up arrangement all Complete to the satisfaction of Engineer in charge (Removing and redoing of brickwork, if required, shall be paid separately) complete all as specified and directed by Engr-In- Charge. | 2,500 | Each | 250 ₹6,25,000 | 90 ₹2,25,000 Lowest | 150 ₹3,75,000 |
| 3.00 | Material & Labour for Jacketing the existing column of size as shown in structural report with concrete of M30 grade design mix concrete. The aforesaid concrete shall be laid by the sides of the existing column with uniform thickness of 115mm or as specified, for jacketing purposes thereby increasing the sectional dimensions by 150 mm or as specified (excluding finishing) at any height with requisite shuttering, centring, scaffolding, propping, repairing the existing surface as specified and also removal of debris, curing etc. complete as per design and drawing etc. (NOTE:-Reinforcement and formwork will be paid separately under respective item of schedule) complete all as specified and directed by Engr-In- Charge. | 1.5 | Cum | 50,000 ₹75,000 | 13,500 ₹20,250 | 11,000 ₹16,500 Lowest |
| 4.00 | Material & Labour for chipping, removing carefully concrete work by low impact hammer, breaker without damaging the structure and cleaning and disposal of debris out side the MoD land etc complete as directed by Engr-in-charge. Hard concrete should not be removed by force including removal of debris outside MoD land complete all as specified and directed by Engr-In- Charge. | 2,790 | Sqm | 30 ₹83,700 Lowest | 63 ₹1,75,770 | 55 ₹1,53,450 |
| 5.00 | Providing and application of hitech concrete penetrating, water based, organic, Bi-polar, calcium nitrite free, migratory corrosion inhibitor on concrete surface having Ph 9.5 which migrates to a virtual extent of 100 mm inside concrete through pores, to inhibit the corrosion process on embedded steel at both anodize and cathodic ends by depassivating the Electro-chemical reaction in that region thereby protecting rebar on all sides complete all as specified and directed by Engr-In- Charge. | 2,790 | Sqm | 50 ₹1,39,500 Lowest | 162 ₹4,51,980 | 240 ₹6,69,600 |
| 6.00 | M & L for applying rust-remover and then applying anti corrosive protective paint of makes mentioned in list of approved makes to all exposed reinforcement bars complete all as per manufacturer's instruction and as directed by Engg-in-charge. | 2,790 | Sqm | 75 ₹2,09,250 Lowest | 135 ₹3,76,650 | 90 ₹2,51,100 |
| 7.00 | M & L for applying one coat of polymer bonding coat of approved make as specified to bind old concrete surfaces of soffit of slab, column, beam and similar structural members for new gunited/ cement surface complete all as per manufacturer's instructions and as directed by Engg-in-charge. | 2,790 | Sqm | 75 ₹2,09,250 Lowest | 207 ₹5,77,530 | 135 ₹3,76,650 |
| 8.00 | M&L for ready mix polymer (SBR latex) modified cement mortar 30+/-5 mm thick including trowelling with wooden tools on prepared concrete surfaces of parent material complete all as specified and directed by Engr-In- Charge.
(Note : Rate shall be inclusive of steel scaffolding. No payment shall be maid for scaffolding separetely) | 2,340 | Sqm | 400 ₹9,36,000 Lowest | 540 ₹12,63,600 | 700 ₹16,38,000 |
| 9.00 | M&L for Rebuilding the section of damaged RCC elements to desire size avg thickness 50-70 mm by providing and casting with micro concrete of grade M-40 and above . with supporting framework, all lead lift, mixing, placing, deshuttering, levelling the surface by grinding off cementitious slurry or construction joint differences if any to satisfaction of Engr in charge etc. complete. | 450 | Sqm | 3,500 ₹15,75,000 | 2,160 ₹9,72,000 | 850 ₹3,82,500 Lowest |
| 10.00 | M&L for GLASS FIBER WRAPPING SYSTEM:.Providing & laying applying glass fiber sheet wrap of minimum 600 gsm over structural members including.surface preparation: grinding / moulding concrete substrate, cleaning it with wire brush, removing oil, laitance if present, rounding sharp edges to min 25 mm radius etc., complete.profiling: applying primer on prepared substrate, filling holes and uneven surface with putty etc., complete.wrapping: wrapping the glass fibre wrap to structural element at desired orientation using tamping roller to avoid any air voids etc., repeat the same procedure for multiple layer with interval of 8 hours.sand pasting: applying saturant, rectify air voids if any, paste the river sand on it to make surface rough to take any further finishes.(mode of measurement: per sq.mt of fiber consume and not application of surface area.) | 50 | Sqm | 500 ₹25,000 Lowest | 3,600 ₹1,80,000 | 1,700 ₹85,000 |
Tender Value
₹8.5 Cr
EMD Value
₹7.5 L
Closing Date
15 Sept 2025, 6:00 pmClosed
CWE (NW) Mumbai
CWE (NW) Mumbai
SPECIAL REPAIR/ RENOVATION TO MD ACCN ACHARYA NIWAS (128 QTRS) AT NEW NAVY NAGAR, COLABA, MUMBAI
2025_MES_722606_1
8215/CWE(NW)Mumbai/E8
Open Tender
Civil Works
Item Rate
365 days
GE (NW) Navy Nagar
Class S
Category a(i)
8 documents required · 8 mandatory
₹3,000
GE (NW) Navy Nagar
₹7.5 L
Yes
29 Nov 2025
25 Jul 2025
17 Sept 2025
25 Jul 2025
15 Sept 2025
3 Sept 2025
25 Jul 2025 - 14 Aug 2025
Amount
Notes : 1) The rates of below items includes necessary barricading of MS sheet upto 3 m ht around the bldg before carrying out repair works, and all safety measures including safety harnesses for working upto 9 th floor. 2) Work shall be executed as per Structural Audit report for reference (Copy of Structural report available with GE Office) 3) Rate shall be inclusive of steel scaffolding, No payment shall be made for scaffolding separetely in respective items.
Material & Labour for Relieving Structural members such as column, beam and slabs of their superimposed loads partially or fully by provision of adjustable steel props, frames etc. including providing necessary timber runners, bracing, jacking up arrangement all Complete to the satisfaction of Engineer in charge (Removing and redoing of brickwork, if required, shall be paid separately) complete all as specified and directed by Engr-In- Charge.
Material & Labour for Jacketing the existing column of size as shown in structural report with concrete of M30 grade design mix concrete. The aforesaid concrete shall be laid by the sides of the existing column with uniform thickness of 115mm or as specified, for jacketing purposes thereby increasing the sectional dimensions by 150 mm or as specified (excluding finishing) at any height with requisite shuttering, centring, scaffolding, propping, repairing the existing surface as specified and also removal of debris, curing etc. complete as per design and drawing etc. (NOTE:-Reinforcement and formwork will be paid separately under respective item of schedule) complete all as specified and directed by Engr-In- Charge.
Material & Labour for chipping, removing carefully concrete work by low impact hammer, breaker without damaging the structure and cleaning and disposal of debris out side the MoD land etc complete as directed by Engr-in-charge. Hard concrete should not be removed by force including removal of debris outside MoD land complete all as specified and directed by Engr-In- Charge.
Providing and application of hitech concrete penetrating, water based, organic, Bi-polar, calcium nitrite free, migratory corrosion inhibitor on concrete surface having Ph 9.5 which migrates to a virtual extent of 100 mm inside concrete through pores, to inhibit the corrosion process on embedded steel at both anodize and cathodic ends by depassivating the Electro-chemical reaction in that region thereby protecting rebar on all sides complete all as specified and directed by Engr-In- Charge.
M & L for applying rust-remover and then applying anti corrosive protective paint of makes mentioned in list of approved makes to all exposed reinforcement bars complete all as per manufacturer's instruction and as directed by Engg-in-charge.
M & L for applying one coat of polymer bonding coat of approved make as specified to bind old concrete surfaces of soffit of slab, column, beam and similar structural members for new gunited/ cement surface complete all as per manufacturer's instructions and as directed by Engg-in-charge.
M&L for ready mix polymer (SBR latex) modified cement mortar 30+/-5 mm thick including trowelling with wooden tools on prepared concrete surfaces of parent material complete all as specified and directed by Engr-In- Charge. (Note : Rate shall be inclusive of steel scaffolding. No payment shall be maid for scaffolding separetely)
M&L for Rebuilding the section of damaged RCC elements to desire size avg thickness 50-70 mm by providing and casting with micro concrete of grade M-40 and above . with supporting framework, all lead lift, mixing, placing, deshuttering, levelling the surface by grinding off cementitious slurry or construction joint differences if any to satisfaction of Engr in charge etc. complete.
M&L for GLASS FIBER WRAPPING SYSTEM:.Providing & laying applying glass fiber sheet wrap of minimum 600 gsm over structural members including.surface preparation: grinding / moulding concrete substrate, cleaning it with wire brush, removing oil, laitance if present, rounding sharp edges to min 25 mm radius etc., complete.profiling: applying primer on prepared substrate, filling holes and uneven surface with putty etc., complete.wrapping: wrapping the glass fibre wrap to structural element at desired orientation using tamping roller to avoid any air voids etc., repeat the same procedure for multiple layer with interval of 8 hours.sand pasting: applying saturant, rectify air voids if any, paste the river sand on it to make surface rough to take any further finishes.(mode of measurement: per sq.mt of fiber consume and not application of surface area.)
Use and waste of water tight formwork to sides of pillars, posts, struts, piers, columns and stanchions of square,rectangular or polygonal shape for roughed finish concrete surface complete all as specified and directed by Engr-In- Charge.
M&L for Providing and fixing MS/TS dowel pins/staple/shear pins including drilling holes in concrete including grouting the pins using polyster resin based grouting materials for grouting the pins sourced from manufacturer's such as Fosroc or Krishna Conchem complete all as specified and directed by Engr-In- Charge.
M&L for applying water based wax emulsion curing compound on concrete surface @ 3-5 Sqm/litre complete all as specified and directed by Engr-In- Charge.
M&L for Drilling Holes of 12mm dia, upto 100mm deep holes in structural members at the intervals of 300 to 500mm in staggered manner or along the crack as directed by the Engr-in-charge in RC structural element including Cleaning of the holes by air blower and Inserting 12mm dia. Teflon nozzles compatible with epoxy injector and having machined external end to receive outlet of grouting gun. Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing and allow to cure the system for min.8 hrs before grouting including removing nozzle projections, excess putty if any over concrete element grinding, levelling and finishing the external surface, after completion of the work, etc complete all as specified and directed by Engr-In- Charge. Note : Epoxy putty cost shall be included in the rate quoted by the bidder.
M&L for Grouting Injecting low viscosity high molecular weight thermostat polymer Monopol 250 H by pressure and using pressure epoxy injector with accessories till nozzles refused to accept the grout, Including Mixing material components part a and part b in required quantities as per mfg instruction by weigh batching Filling the grouting gun with monopol 250 H and maintaining desired pressure in the gun, air compressor and at exit (minimum 3 to 4 kg/Cm2) by a mechanism to monitor both pressure gauges and controlling the same by release valves and release the grout as per requirement simultaneously to grout the structural element through prefixed nozzles till its refusal. Seal the nozzle with thixotropic epoxy putty after the refusal. Note : leakages through other nozzles or cracks are required to be monitored while grouting and such points to be sealed as and when required without any extra cost.complete all as specified and directed by Engr-In- Charge.
Supplying, Drilling/Cleaning hole and injecting Hilti make ETA Approved HY 200-R chemical. Application to be designed separately for Rebar's as Simply Supported, Moment or Splice Connection as per EC2/TR023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDEA22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate diameter and embedment of rebar's to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebar's. HY200-10 mm dia 200mm depth complete all as specified and directed by Engr-In- Charge.
M&L for Opening the Separation Cracks at the Junction of RCC and Masonary where ever directed and instructed into ‘’V’’ Grooves 2’’ to 3’’ from the either side of the cracks by carefully marking the areas to be opened up using a Cutting machine and skilfully /carefully Chiselling with a well sharpened chisel and hammer as directed including Wire brushing and washing of concrete Substrata and masonry walls with water jet to the surfaces thus prepared to the entire satisfaction of the Consultant as instructed and directed.
M&L for Moistening the Cracks, Providing and applying priming/bonding coat of slurry made out of “Polyalk EP”and cement (or equivalent as specified in the List of Brand names) in proportion 1:1 to surfaces prepared as instructed and directed. Filling the Cracks /Grooves by Providing and applying “Polyalk EP” Polymer modified cement mortar (or equivalent as specified in the List of Brand names) in Proportion of 1: 5: 15 (Polyalk EP: Cement: Graded sand/quartz sand) on the prepared surfaces and finishing it in level with the existing plaster Including Hand packing, curing and making the surface similar to the external plastering using wooden floats/punch etc. complete all as specified and directed by Engr-In- Charge. Note for 2.00 to 17.00: Work shall be carried out through approved applicator of the manufacturer and certificate shall be submitted alongwith RAR/FB
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for and remove the debris outside from MoD land complete all as specified and directed by Engr-In- Charge.
M&L for RCC M30 Design Mix using 20 mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like for height upto 9th floor complete all as specified and directed by Engr-In- Charge.
M&L for TMT (CRS) bars 10mm dia & over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and directed by the Engineer-in-charge.
M&L for TMT(CRS) bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and directed by Engr-In- Charge.
M&L for for Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for fair finished surface of concrete flatcomplete all as specified and directed by Engr-In- Charge.
M&L for Form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor & roofs n exc 20 cm wide & sides of RCC/PCC bands in walls, horizontal or sloping & similar work exc 10cm but n exc 20cm wide for Roughed finished surface of concrete flat complete all as specified and directed by Engr-In- Charge.
M&L for Plain/ Reinforced Cement Concrete Type B1 1:2:4 (using 20 mm graded stone aggregate) cast in situ in lintels up to 1.5 M span, cills and other similar bands, plinth courses, parapets, copings, bed plates and the like including weathering, slightly rounded or chamfered angles and throating, as directed. including form work etc complete all as specified and directed by Engr-In- Charge.
Demolition of concrete of any description and in any position not otherwise specifically provided for etc. removing the debris from MoD land complete upto 9 Storey complete all as specified and directed by Engr-In- Charge.
M&L for roughening the surfaces of old cement concrete floor by picking, cleaning and washing down with water to remove dust etc. rendering 15 mm thick in ready mix mortar and applying two coats of hot bitumen 85/25 grade @ 1.50 Kg/Sqm over vertical sides of sunken floors. complete all as specified and directed by Engr-In- Charge.
M&L for cement concrete 1:7:12 with 40mm graded stone coarse aggregate in sunken floor complete all as specified and directed by Engr-In- Charge.
S & F in repairs Extended Wall Hung Closet of size 660 x 365x730 mm white, with integral wall rests including flushing cistern and flush pipe , seat cover complete all as specified and directed by Engr-In- Charge. KEROVIT CAT PART NO:AXEL-KS129 or technocommercial equivalent make given in Appx B
Supply & Fixing in repair 110mm PVC (SWR) ‘P’ or ‘S’ Traps jointed with solvent fixed to wall or floor including all fittings complete all as specified and directed by Engr-In- Charge.
S&F 40mm UPVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors including necessary coupler and bends etc.complete all as specified and directed by Engr-In- Charge.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
S & F in repair PVC connectors of 15 mm size with PTMT nuts of 600 mm length complete all as specified and directed by Engr-In- Charge.
S & F in repair PVC connectors of 15 mm size with PTMT nuts of 450 mm length complete all as specified and directed by Engr-In- Charge.
Taking down rainwater or waste pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by Engr-In- Charge.
S&F 110mm PVC (SWR) pipes single socket-ed in any length with rubber ring joints fixed to walls complete all as specified and directed by Engr-In- Charge.
S & F for Pipe Supporting Clamping - Single Pipe of dia 110 mm (4") down take pipe fixing done with Clamping System consists of Profile Bracket + Continuous Slotted C Channel + U Bolt Rubber Sleeve mounted System running vertically with wall distance 75 mm (3") Material Qty. for one unit : 1. Profile Bracket Wall distance 75 mm (3") - 2 Nos. 2. Continuous Slotted C Channel of Size 250 mm (10") - 1 No.; 3. U Bolt Rubber sleeve mounted for 110 mm (4") CI or PVC Pipe Dia. - 1 No.; and 4. Fixing Nail Zn coated of thickness 6.5 mm and length 63 mm (2 1/2") - 4 nos. All other detail as specified in Chief Engineer Navy Mumbai Technical Drawing (TD) of Pipe Supporting System No. TD/2023/01. complete all as specified and as directed (upto 9 Storey).
S&F 75mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed by Engr-In- Charge.
S&F for Pipe Supporting Clamping - Single Pipe of dia 75mm (3") down take pipe fixing done with Clamping System consists of Profile Bracket + Continuous Slotted C Channel + U Bolt Rubber Sleeve mounted System running vertically with wall distance 75 mm (3") Material Qty. for one unit : 1. Profile Bracket Wall distance 75 mm (3") - 2 Nos. 2. Continuous Slotted C Channel of Size 250 mm (10") - 1 No.; 3. U Bolt Rubber sleeve mounted for 75mm (3") PVC Pipe Dia. - 1 No.; and 4. Fixing Nail Zn coated of thickness 6.5 mm and length 63 mm (2 1/2") - 4 nos. All other detail as specified in Chief Engineer Navy Mumbai Technical Drawing (TD) of Pipe Supporting System No. TD/2023/01. complete all as specified and directed by Engr-In- Charge.
S&F PVC (SWR) reducers 110mm bore complete all as specified and directed by Engr-In- Charge.
S&F PVC (SWR) bend any radius with oval access door 110mm bore complete all as specified and directed by Engr-In- Charge.
S&F PVC (SWR) bend any radius 110mm bore complete all as specified and directed by Engr-In- Charge.
S&F PVC (SWR) branch pieces, single (single Y) equal or unequal 110 mm bore without oval access door complete all as specified and directed by Engr-In- Charge.
S&F PVC (SWR) branch pieces, single (double Y) equal or unequal 110 mm bore without oval access door complete all as specified and directed by Engr-In- Charge.
S&F PVC (SWR) vent cowl 110 mm bore with cement joints complete all as specified and directed by Engr-In- Charge.
S & F PVC (SWR) branch piece, Single (single T) equal or unequal for 110 mm bore with oval access door complete all as specified and directed by Engr-In- Charge.
S&F PVC (SWR) floor trap, plain with grating including jointing with solvent cement for 75 mm outlet pipe complete all as specified and directed by Engr-In- Charge.
S&F 125mm x125mm square Stainless steel cockroach trap with white cement in floor trap complete all as specified and as directed (upto 9 Storey).
S&F 160mm PVC (SWR) pipes single socket-ed in any length with rubber ring joints fixed to walls complete all as specified and as directed (upto 9 Storey).
S & F for Pipe Supporting Clamping - Single pipe of dia 6" (160 mm) down take pipe fixing done with Clamping System consists of Profile Bracket + Continuous Slotted C Channel + U Bolt Rubber Sleeve mounted System running vertically with wall distance 75 mm (3"): Material Qty. for one unit : 1. Profile Bracket Wall distance 75 mm (3") - 2 Nos. 2. Continuous Slotted C Channel of Size 300 mm (12") - 1 No.; 3. U Bolt Rubber Sleeve mounted for 160 mm (6") CI or PVC Pipe Dia. - 1 No.; and 4. Fixing Nail Zn coated of thickness 6.5 mm and length 63 mm (2 1/2") - 4 nos. All other details as specified in Chief Engineer Navy Mumbai Technical Drawing (TD) of Pipe Supporting System No. TD/2023/01. complete all as specified and as directed (upto 9 Storey).
S&F 160mm bore PVC (SWR) bends complete all as specified and as directed (upto 9 Storey) complete all as specified and directed
Supply & Fixing Stainless steel SS 302 towel rail/rack, nickel chrome finished, water proof, corrrossion resistant 600mm long 220 mm wide and 15 mm dia rod including necessary brackets/ wall plugs complete all as specified and as directed
S &F chromium plated brass towel ring nominal dia of rod 18 mm all as specified and directed.
S & F in repair Vitreous China wash basin, white, flat back, size 450 x 300 mm excluding water taps waste chain plugs and porcelain stopper but including brackets upto 9 storey
S&F in repair CP brass swan neck pillar tap 15mm, screwed down high pressure fancy type all as specified and directed.
S & F in repair sinks made of stainless steel 1mm thick, kitchen with plugs, washers & wastes, incl bedding in cement mortar on to dwarf fixing cantilever brackets & connecting union to pipe overall size 495mm X 420mm bowl size 410mmX 330mm X160mm all as specified and directed
S&F 32 mm dia Waste coupling, brass chromium plated suitable for glazed ware sinks, wash basins etc with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed by Engr-in-Charge.
S & F PVC corrugated waste pipe of 32 mm dia 900 mm long complete all as specified and directed.
S & F stainless steel plate rack 0.63mm thick stainless steel sheet overall size stainless steel plate rack 24"x24"x10" kitchen rack of approved pattern & make fixed to wall with CP brass screws complete all as specified and directed by Engr-in-Charge.
S & F stainless steel glossy finish double Soap dish fixed to wall with chromium plated brass screws complete all as specified and as directed by Engr-in-Charge.
S&F PVC cabinet size 300x450 mm with looking mirror in white colour complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M&L for 25mm thick Cement concrete type B-0, 1:2:4 using(12.5 mm grade stone aggregate) as in sub base floor, upto 9 Storey.
M&L Non - skid coloured ceramic tiles 7 to 8 mm thick of size area of each tile 300mmx300mm in floors over and including set and jointed in neat cement slurry and fixing of tiles in tiles adhesive (Note : Cost of factory made tiles adhesive screed bed are included) upto 9 Storey.
M&L glazed ceramic tiles in vertical surface 450x300x 7 to 8 mm thick set and jointed in neat cement paste over and including 10 mm thick tiles adhesive and pointed in white or colour cement to match (Note : The rates include the cost of 10mm thick tiles adhesive ) upto 9 Storey.
M&L stone face ceramic tiles in vertical surface 450x300x 7 to 8 mm thick set and jointed in neat cement slurry over and including 10 mm thick tiles adhesive and pointed in white or colour cement to match (Note : The rates include the cost of 10mm thick tiles adhesive ) upto 9 Storey.
M&L Double charged Glazed Vitrified tiles of size 600mm x 600mm x 9 to 10 mm thick in floors or as skirting over and including 10 mm thick tiles adhesive and jointed in neat cement slurry upto 9 Storey complete all as specified and directed
Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar including removing debris outside MoD land complete all as specified and directed upto 9 Storey complete all as specified and directed
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, upto 9 storey complete all as specified and directed
M&L for 18-20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like over 15 mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including grinding and polishing complete upto 9 Storey complete all as specified and directed
M&L for machine cut pre-polished kota stone slab flooring 20-25mm thick over and including 15 mm thick cement screed base (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete (Note : The rate includes the cost of cement screed bed) upto 9 Storey complete all as specified and directed
M&L for 12mm thick full body anti skid vitrified tiles in flooring and skirting set and jointed in neat cement slurry over and including 10 mm thick tiles adhesive and pointed in white or colour cement to match upto 9 storey complete all as specified and directed
M&L 15mm thick full body anti skid staircase vitrified tiles in riser of steps, skirting, dado with double bull nose and anti skid grooves on tread set and jointed in neat cement slurry over and including 10 mm thick tiles adhesive and pointed in white or colour cement to match upto 9 storey complete all as specified and directed
Rounding to edges of stone slabs (kota/granite etc) one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed
Taking down chowkhats or frame (w/o taking off shutters from the frames) but not exc 1.50 each complete all as specified and directed
Taking down chowkhats or frame (w/o taking off shutters from the frames) but exc 1.50 Sqm but n.exc 4.00 Sqm each upto 9 storey complete all as specified and directed
Taking down Shutters of any description exc 1 Sqm and n exc 2 Sqm each complete all as specified upto 9 storey complete all as specified and directed
Taking down shutters of any description n. exc 1 Sq. M upto 9 storey complete all as specified and directed
S&F coloured anodized aluminium frame/track or shutters for windows, ventilators etc with one or more rebates incl joining cleat for fixing etc. fixed or sliding type/louvered window or ventilator without sash bar, aluminium including necessary joining cleats glazing clips rubber packing, anodized aluminium snap beading screws locking arrangements etc. including necessary working platform (scaffolding) and safety measures Complete all as specified and as directed by Engr-in-Charge (upto 9 storey)
M&L for aluminium grill with suitable aluminium anodized frame section of F section of size 23.4x15.3x4 mm thick manufactured by M/S Deco grill pattern DG-102(7.50 mm width and aperture 50 mm ) Complete all as specified and as directed by Engr-in-Charge (upto 09 storey).
S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple
S&F 4.8 mm thick plain sheet glass area n.exc 0.5 sqm ordinary quality and glazing with aluminium and neoprene beads in each pane Complete all as specified and as directed for upto 9 storey.
S&F 4.8 mm thick frosted glass ordinary quality in square n.exc 0.50 sqm each fixed to aluminium window frame complete all as specified and directed by Engr-In- Charge.
S&F for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 90 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with mitre joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with SS dash fasteners of required dia and lengthcomplete all as specified and directed by Engr-In- Charge.
S&F factory made single extruded WPC solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. Note: stainless steel butt hinges shall be paid separately complete all as specified and directed by Engr-In- Charge.
S&F 2nd class hard wood (Sal) plain, solid straight chowkats and frames, wrought framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed by Engr-In- Charge.
S&F 2nd class hard wood (Sal) 35mm thick factory made plain framed, panelled shutters (two panels) with lock rail and panel of 9mm BWP commercial or 12mm veneered particle board with commercial veneer on both faces the size of rail and stile as per IS 1003 (Part-I) kiln seasoned and chemically pressured treated upto 9 storey complete all as specified and directed
S & F 2nd class hardwood (Sal) 35mm skeleton shutters, open rebated and prepared to receive wire mesh edge of framing plain, chamfer-ed or rounded, fitted with cut and mitred beds for securing mesh, etc.; sizes of members of shutters complete all as specified and directed by Engr-In- Charge.
S&F 2nd class hardwood (Sal) bull nosed splayed, chamfered or rounded on edge fillets rectangular in section, sectional area exc 13 but n. exc 25 Sqcm complete all as specified and directed by Engr-In- Charge.
S & F 35 mm thick single side decorative face veneer with lipping/frame to match flush shutters, solid core construction, with block board core and plywood face panels, commercial type on other sides complete all as specified and directed by Engr-In- Charge.
S & F 125 mm hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified and directed by Engr-In- Charge.
Re securing or easing & adjusting wooden door shutters of any description, without taking down exc 1 Sqm and n exc 2 Sqm each complete all as specified and directed by Engr-In- Charge.
Supply & Fixing in repair 100mm size SS butt hinges medium weight fixed with SS screws complete all as specified and directed by Engr-In- Charge.
Supply & Fixing 100mm size SS butt hinges medium weight fixed with SS screws complete all as specified and directed by Engr-In- Charge.
S & F 150 mm long Aluminium, anodized, barrel tower bolts of extruded section complete all as specified and directed by Engr-In- Charge.
S & F in repairs 150 mm long Aluminium, anodized, barrel tower bolts of extruded section complete all as specified and directed by Engr-In- Charge.
S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodized complete all as specified and directed by Engr-In- Charge.
S & F in repairs 150 mm long Extruded Aluminium alloy handles, fabricated type, anodized complete all as specified and directed by Engr-In- Charge.
S & F 300 mm long Aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and directed by Engr-In- Charge.
S & F 200 mm long Aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and directed by Engr-In- Charge.
S & F in repairs 300 mm long Aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and directed by Engr-In- Charge.
S & F stainless steel magnetic wall door stopper complete all as specified and directed by Engr-In- Charge.
S & F stainless steel magnetic door catcher for cupboard/cabinet complete all as specified and directed by Engr-In- Charge.
S&F factory made Almirah/ Kitchen cabinet shutter made of 18mm thick Marine plywood, BP grade architect ply as per IS 710 ( Greenply/ century/ Kitply) with 1.0 mm thick high gloss laminate in front of shutter and 0.8mm plain laminate for rear side, colour and pattern as approved and fixed with approved adhesive as per manufacturers instructions, all shutter shall have PVC edge bands on all side with rounding moulding on vertical edges, Finish of PVC edge shall be same as per shutter finish, including fixtures and fastening for fixing of steel racks complete all as specified and directed by Engr -in- Charge.
S&F factory made Kitchen partition for 18mm thick Marine plywood, grade BWP, type BB with both side 0.9mm thick plain laminate type 1 of surface finish, colour and pattern as approved and fixed with approved adhesive as per manufacturer's instruction, fixed with screws to timber frame work0.9mm laminate lipping all edges etc complete all as specified and directed by Engr -in- Charge.
Supply and fixing stainless steel kitchen baskets for storage of plates, cups, bottles etc., made out of stainless steel of grade SS 304 not less than 6 to 8 Kg each using square hollow tubes of size 12mm x 12mm x 1.25mm thick for framework as required and solid round bars / 26 gauge thick sheet to make desired pattern, suitable for sliding under kitchen platform on a pair of channels, including fixing with steel screws, fixed in repairs, complete all as specified and directed by Engr -in- Charge. Note : Telescopic channels shall be measured and paid under separate item.
Supply and fixing stainless steel soft closing 90 to 110 degree hinges complete all as specified and directed by Engr -in- Charge.
Supply & Fixing of stainless steel handles decorative type 100 mm size for kitchen cabinet shutters,
Supply and fixing stainless steel Telescopic channels, with ball bearings, suitable for Sliding stainless steel kitchen basket 45cm long standard width; complete all as specified and directed by Engr-In- Charge.
Supply and fixing of 04 pieces pulley operated Cloths Drying system casting of Aluminium pipe of outer dia 22 mm inner dia 19.8 mm and channel pair of length 2.50 mtr with pulley made up of Devil mounted and fixd with self tapping screw. Rope will be HDPE double core of 4 mm with rope Guide at locking system to hide rope. Channel to be dia of minimum weight of pipe shall not b less than 0.20 kg/Rm and maximum weight of pipe in one unit not less than 2 kg. Weight of rope shall be not less than the 550 Gms / Mtrs.
M&L for Machine cut cudappah stone slab 20-25mm thick over 15 mm thick cement screed base in CM 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engr-In- Charge.
M & L for preparing new wood or wooden surfaces over 10 cm of width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engr-In- Charge.
M & L for preparing old or previously untreated wooden surfaces over 10 cm of width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engr-In- Charge.
Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.including removal of debris outside MoD land complete all as specified and directed by Engr-In- Charge.
M & L for Providing and applying dubbing coat avg 20mm thick plaster with readymix prepacked proportioned dry mix mortar, blended with PP fibers, on other than fair faces of brick wall or concrete surfaces by means of gunniting method, on external surfaces including transporting of material, mixing, curing, etc.complete as per direction of Engr-in-charge.
M & L for Providing and applying sand face 10mm thick plaster with readymix prepacked proportioned dry mix mortar, blended with PP fibers, mixed with liquid water proofing compound on other than fair faces of brick wall or concrete surfaces additives, on external surfaces including transporting of material, mixing, curing, etc.complete as per direction of Engr-in-charge.
M & L Providing and applying fair finish 15mm thick plaster with ready mix prepacked proportioned dry mix mortar fair faces of brick wall or concrete surfaces , on internal surfaces including transporting of material, mixing, curing, etc.complete all as specified and directed by Engr-In- Charge.
M & L Providing and applying 10mm thick plaster with ready mix prepacked proportioned dry mix mortar, blended with PP fibres, on fair faces of brick wall or concrete surfaces additives, on ceiling surfaces including transporting of material, mixing, curing, etc.complete all as specified and directed by Engr-In- Charge.
M & L Providing and applying fair finish 20mm thick plaster with ready mix prepacked proportioned dry mix mortar mixed with PP fibre fair faces of brick wall or concrete surfaces , on external surfaces including transporting of material, mixing, curing, scaffoldings etc upto 9 th floor complete all as specified and directed by Engr-In- Charge.
M&L Complete removal of existing treatment on wall surface complete all as specified and directed by Engr-In- Charge.
M & L Providing & applying anti algal water-based elastomeric exterior wall finish on old/newly plastered surfaces including surface preparation, applying suitable wall prime seal primer coverage area as per manufacture instruction and application of two coats (base coat & top coat coverage area per manufacture instruction) & of paint by roller etc. complete all as specified and directed by the Engineer-in-charge. Notes:- 1. Work will be executed by authorized applicator of approved manufacturer. 2. Every coat of finish will be approved by GE before starting new layer/coat. 3. Building vintage 1985 and are structurally sound. 4. Contractor to submit minimum 03 yrs warranty certificate from the company.
M& L for 1-2 mm thick wall care putty on wall surface all as specified and as directed
M& L for 1-2 mm thick wall care putty on ceiling surface complete all as specified and directed by Engr-In- Charge.
M&L for preparing newly plastered surfaces or putty surface of wall and applying two coats of oil emulsion distemper over a coat of alkali resistance primer complete all as specified and directed by Engr-In- Charge.
M&L for preparing newly plastered surfaces or putty surface of ceiling and applying two coats of oil emulsion distemper over a coat of alkali resistance primer complete all as specified and directed by Engr-In- Charge.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles including removal of debris outside MoD land complete all as specified and directed by Engr-In- Charge.
M&L for Brick work with sub class 'B' brick straight or curved on plan exc 6 mtr mean radius built in CM 1:6 complete all as specified and directed by Engr-In- Charge.
Excavation in trenches n exc 1.50m wide and nexc 1.50m in depth for fdn etc n.exc 10 sqm on plan and nexc 1.50m in depth and getting out in hard/dense soil complete all as specified and directed by Engr-In- Charge. Note : Rate shall includes removing of paver blocks carefully and stack properly (whereever required).
Demolition and breaking up drain pipes (salt ware,AC, or reinforced concrete set in cement mortar including removal of debris outside MoD land complete all as specified and directed by Engr-In- Charge.
M&L for concrete bed to drain pipes in cement concrete 1:3:6 type C2, 150 mm bore including forming cradle with concrete after they are laid and tested complete all as specified and directed by Engr-In- Charge.
M&L for reinforced concrete pipes 150mm, class NP2, laid in trenches and jointed with collars complete all as specified and directed by Engr-In- Charge.
M&L for concrete bed to drain pipes in cement concrete 1:3:6 type C2, 450 mm bore including forming cradle with concrete after they are laid and tested complete all as specified and directed by Engr-In- Charge.
M&L for reinforced concrete pipes 450mm, class NP2, laid in trenches and jointed with collars complete all as specified and directed by Engr-In- Charge.
Removing excavated (soil) materials and deposited out of MD land up to a distance upto 50 Km directed as per BMC bylaws complete all as specified and directed by Engr-In- Charge.
Returning, filling, including spreading, levelling, watering and well ramming in layers not exc 25 cm hard/dense soil complete all as specified and directed by Engr-In- Charge.
Removal of existing water proofing treatment of the roof, cleaning with wire brushes etc including removing demolished materials outside MD land complete all as specified and directed by Engr-In- Charge.
Material & Labour for PCC (1:2:4) type B-0 (using 12.5 mm graded agg) in roof kerbs or mud stops, levelling coarse of roof, rounded or chamfered on edge complete all as specified and directed by Engr-In- Charge.
M&L for preparation of newly plastered/RCC/PCC surface making surface completely dry and applying primer conforming to IS 3384-1965 @ 0.30 Kg/Sqm to be applied on prepared surface till the surface is properly impreganted.water proofing treatment shall be provided with APP modified water proofing membrane 3 mm thick ( weighting not less than 3.00 Kg/Sqm on prepared suface after the primer has dried the membrane will be laid by torching to the surface with 10 cm side overlap and 15cm end oeverlap as per manufacturer instruction and under strict supervision
M&L for applying for two coats of Aluminium paint over the APP membrane complete all as specified
Dismantling of wrought iron and mild steel work of any description upto 9 storey.
S&F mild steel rolled section as in main and cross beam, hip and jack rafters, purlins where connected to common rafter and running rails etc complete conforming to Fe-290- W(Gde?E-165) quality?B including working platform/scaffolding) Complete all as specified and as directed by Engr-in-Charge.
M&L for mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed by Engr-In- Charge.
M&L for mild steel framed work such as gates etc ornamental and intricate designed and similar work conforming to Fe.290.Gde-E-165 including stops, hand-made sliding bolts, Pintel hinges etc. complete all as specified and directed by Engr-In- Charge.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed by Engr-In- Charge.
M&L for Preparing of new steel surfaces of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-In- Charge.
M&L for Preparing of old steel surfaces of any description and applying one coats of synthetic enamel paint complete all as specified and directed by Engr-In- Charge.
Supply & Fixing in repairs fancy type drapery rods, powder coated aluminium of 25mm size with/including end brackets, and hanging arrangements etc. complete all as specified and directed by Engr-In- Charge.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings or chajjas (FRP or any other pattern) complete all as specified and directed by Engr-In- Charge.
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor for height of building exceeding 10 metres but not exceeding 20 metres complete all as specified and as directed.
S&F 10mm thick double wall transparent polycarbonate sheet as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-In- Charge.
S&F 6mm thick 400mm wide cement fibre board on crumple joint with suitable size stainless screw at 300mm interval including cleaning of crumple joint complete all as specified and directed
S&F 20 gauze thick aluminium sheet on crumple joint with suitable size stainless screw at 300mm interval including cleaning of crumple joint complete all as specified and directed
Grubbing up and uprooting of trees / plants from external walls of bldgs upto 9th storey height pouring muratic acid for burning residual roots in any. Racking out the dead roots from plants / concrete joints upto its penetrated portion and filling with PCC (1:2:4) 12.5 mm graded aggregate and finishing the surface with 15mm rendering in CM (1:4) including necessary hanging arrangement complete all as specified and directed by Engr-In- Charge.
M&L for Sand filling under floors or in foundation including watering and consolidation etc complete all as specified and directed by Engr-In- Charge.
Material and labour for 75mm thick cement concrete 1:3:6 type C-2 with 40mm graded coarse aggregate as in sub base complete all as specified and directed by Engr-In- Charge.
M&L for 60 mm thick glazed coloured machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658- 2006 M-35 Grade with grey cement and no pigment incl dismantling old u/s one complete all as specified and directed by Engr-In- Charge.
Material and labour for post construction treatment of voids in masonry by using Imidacloprid 0.075% SC in holes , at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors all as specified and as directed by Engineer-in-charge.
Material and labour for post construction treatment at points of contact of wood work by using Imidacloprid 0.075% SC in holes by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same with sealing compound complete all as specified and directed by Engr-in-Charge.
Supply only liquid water proofing compound.
Dismantling and taking out unserviceable safety edge of any type & supply and fixing new full beam infrared sensor upto full length of car doors (2.00 mtr) as specified and directed by the Engineer-in-Charge.
Replacement of automatic door drive unit with motor on car top with VVVF of 1 HP capaicity all as specified and directed by Engineer-in-Charge.
Dismantling and taking out unserviceable old Landing push button box along with illuminated call button with controll wiring supply & fix Landing push button box along with illuminated call button with digital arrow indication with controll wiring, for G+14/G+5/G+6 storey building complete all as directed by Engineer-in-Charge.
Replacement of unserviceable ARD control system and commissioning and testing of new ARD system suitable for upto 15 KW motor including wiring with connected items in existing G+8 Storey building 8/13 Passenger lifts 415V,50 Hz,3 phase with a speed of 1.2 mtr/sec comprising with maintenance free battery 12 V, 17 AH (04 Nos five year Maintenance free battery, Make Exide/Amaron) to match with the existing capacity motor and controller system complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking out unserviceable COP assembly, Supply and fixing new assembly complete with illuminated push button for floor position, alarm, non stop door open, door close, cabin fan, cabin light stop, attend out key etc with direction indicator with LED display with CPI card of stainless steel face plate in and including necessary wiring for illuminating push button complete all as specified and directed by Engineer-in-Charge for G+8 Storey buildings,Lifts.
Disconnecting and taking out old/unserviceable shaft wiring, supply and fixing of shaft wiring in hoist way upto lower limit with PVC insulated copper conductor cable single core, 1100 Volts grade 0.75 Sqmm 24 Nos single core & 1.0 Sqmm for earth wire duly bunched with wire binding locking strip, drawing through in and including galvanished sheet metal trucking of 24 SWG up to ground floor in hoist for control to all function including in built connection for control panel, PCB, Hall push button, fire switch and lower limit switch all as specified and directed by the Engineer-in-Charge. (G+8 Storey building).
Dismatling and taking out unserviceable old control panel and control wiring and supply and fix new CAN BAS Integrated Drive based collectice control panel in hinged MS powder coated cabinet with control wiring comprising with multiple microcontrolled programmed chip based controlled by pulse modulation, complete with all safties such as thermal overload protection, over current protection, auto phase reverse link to each other in net work and compitable to 11 KW/15HP capacity VVVF drive including proper connection with proper lugs, terminal connectors screws and motor connection with galvanised sheet trunking 24 SWG including wiring of main motor with suitable size of stranded copper cable etc complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking out defective unserviceable main drive (any type) from existing control panel and supply and fixing CAN BAS Integrtaed drive suitable for 8/13 Ps lift G+8 storey building complete with all electric connection.
Taking down old unserviceable main steel wire rope after disconnecting old wire rope from counter weight, pulley and car cabin and supply and fix new main steel wire rope 13 mm dia, ungalvanised, 8/19 construction in and including necessary connection with counter weight, pulley and car cabin with clamps, nut, bolts and washers etc complete all as directed by Engineer-in-Charge.in 8/13 /Goods Lift, G+8 Storey buildings .Make : USHA MARTIN
Disconnecting and taking out old/unserviceable travelling cable from hoist way and supply and fix new travelling cable PVC Insulated 16 Core with stranded copper conductor, 1100 volts grade of size 0.75 Sqmm conforming to relevant IS including criping with lugs appropriate thimples complete all as specified and directed by Engineer-in-Charge.
M & L for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth strip 32 X 6mm by means of bolts, nuts and washers of galvanized iron or steel upto the test point connected to lifts including PCC earth pit with CI cover, GI funnel with wire mesh, GI protection pipe light grade of 40 mm bore or earth lead and 20mm bore GI pipe light grade for watering, excavation and earth work in any type of soil, filling the pit with charcoal and common salt surrounding the earth plate complete all as specified and shown in electrical plate No.3 of SSR Part-I
Taking down copper/ aluminium point wiring ie. light, fan, socket or power/points complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of ceiling, walls, floors, etc.
M & L for concealed point wiring with PVC insulated unsheathed single core multi stranded copper conductor 1.5 sqmm, 1100 volts grade cable, FRLSH, passing through PVC concealed conduit less than 25 mm bore including accessories and provision of metal flush box for mounting of modular Switchs & Sockets as required at site as directed by Engineer-in-Charge including one run of PVC insulated unsheathed multistranded copper conductor cable 1.5 sqmm (green colour) FRLSH earth wire and connected to earth dolly for the following:- NOTE : Circuit conductor from MCB DB to Switch boards should not be less than 2.5sqmm. 2. where concealed conduit wiring is not feasible surface wiring will be carried out 3. Cost of cutting chases shall be included in the quoted rate.
One light/Exhaust/Ceiling fan point controlled by one switch.
One 3 pin switch socket combination 5 Amps on the same board with other switches.
One 3 pin switch socket combination 5 Amps on independent board.
One bell point controlled by one push button
All as per item No 173.00 above but with 2.5 sqmm cable for one three pin 15 Amps socket out let controlled by one switch.
S & F modular switch, 1 module, single pole one way 6Amp.
S & F modular switch, 1 module, single pole one way 16Amp.
S & F ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body of size 60x50mm
S & F modular socket 2/3 pin, 2 module, 6A.
S & F Socket 6/16A, 6 pin, 2 module.
S & F modular bell push switch, 1 module, single pole one way 6Amp.
S & F modular electric bell ding dong, AC, 230V single pole.
S & F with modular stepped type fan regulator, 2 module, single pole one way.
S & F in replacement with lamp holder PVC/Polycarbonate body with back plate complete all as specified and as directed.
Supply and Fix LED lamp 9 watt (min 120 lumen/watt), 230 Volt complete all as specifed and as directed.
Taking out old wooden/PVC board and disconnecting all electric connection from switches, board and S & F modular metal flush box, screwless of 8 module for mounting of modular switches and sockets including blank plate for blank module.
Taking out old wooden/PVC board and disconnecting all electric connection from switches, board and S & F modular metal flush box, screwless of 6 module for mounting of modular switches and sockets including blank plate for blank module.
Taking out old wooden/PVC board and disconnecting all electric connection from switches, board and S & F modular metal flush box, screwless of 3 module for mounting of modular switches and sockets including blank plate for blank module.
Taking out old wooden/PVC board and disconnecting all electric connection from switches, board and S & F modular metal flush box, screwless of 1 module for mounting of modular switches and sockets including blank plate for blank module.
S&F modular white cover plate with frame, 8 module.
S&F modular white cover plate with frame, 6 module.
S&F modular white cover plate with frame, 3 module.
S&F modular white cover plate with frame, 1 module.
Taking down unserviceable FTL and supply and fix Slim LED integrated batten of 20Watt 4ft (min 120 lumen/watt) coolday light with powder coated CRCA decorative patti prewired complete with two Nos of PVC box of size 75x75x20mm for mounting light fittings including ceiling rose complete.
Taking down unserviceable FTL and supply and fix Slim LED integrated batten of 10Watt 2ft (min 120 lumen/watt) coolday light with powder coated CRCA decorative patti prewired complete with two Nos of PVC box of size 75x75x20mm for mounting light fittings including ceiling rose complete.
Taking out any type of fitting bulkhead/FTL and S&F 10 watt linear LED batten, 2 feet, aluminium extruded channel, powder coated with diffuser for glare free light, inbult motion sensor prewired with 25% dimmer illuminiuos in ideal time with all accessories including two nos of PVC box of size 75x75x20mm for mounting light fittings complete in common area and staircase.
S&F MCB DB SPN double door conforming to IP 43 - IK 09 with acrylic door, 8 way complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces by plastering or PCC work inclding distembering to the affetced to walls.
S&F in repairs MCB SPN, 32 Amp, 10 KA, 230 Volt.
S&F in repairs MCB, single pole, upto 20 Amp, 10 KA, 230 Volt.
S&F in repairs ceiling fan 1200mm sweep, 230V, 50Hz, minimum 5 star rating and energy saving, hanging on ceiling and connect with copper conductor multi stranded 3 core wire of size 14/0.0076 complete all as specified and as directed.
S&F Single pole and earth sheet metal enclosure with a three pin and earth metal clad plug with socket complete with one Single pole 20 Amps MCB, 10 KA, 240 Volts.
S&F Exhaust fan, heavy duty, double ball bearing, 230V, 50Hz,300mm sweep including frame , blade complete with protective bird guard including connection as required at site with flexible copper cable all as per specified and directed.
S & F submain wiring PVC insulated, PVC sheathed, armoured, FRLSH, 1100V grade, 2 core 6 sqmm stranded copper conductor electric cable laid on wall/ roof/ duct complete with proper saddling and connecting meter to DBs with glands including taking out existing unserviceable cable complete all as specified.
M & L for replacement of existing old u/s submain wiring with two single core PVC insulated flexible copper conductor cable of size 4 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 4 Sqmm as earth lead in and including concealed PVC conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed.
M & L for snap-on trunking system with cover, angles bends and all accessories and fitting of size 50x80 mm fixing on wall complete all specified and directed.
Taking down old unserviceable and M&L for fabrication of Panel, double door made out of 2mm thick CRCA sheet, CPRI approved, indoor type suitable for 3 phase, 4 wire, 415 volts, individual compartment for MCCBs and Coper busbar of 200 amps capacity alongwith compartment for fixing of 32 Nos smart IS-16444 specification meters with necessary clamps, nuts, bolts and washers, internally prewired with all connecting accessories, floor mounted type made with angle iron legs 40x40x4 mm thick, powder coated painting incl foundation 60 cms above the ground level in PCC 1:3:6 type C2 all as specified & Directed consisting of following :-
Incomer : (a) MCCB 200 Amps, 4 Pole, 36 kA, thermal magnetic release, Ics=100% Icu - 01 Nos,
Outgoings :
(a) MCB SPN 32 Amps, 10KA - 32 Nos,
(b) Single pre paid smart IS-16444 energy meter - 32 Nos,
(c) Digital Ammeter - 01 Nos
(d) Digital Voltmeter - 01 Nos
(e) Phase indicator lamp R,Y & B - Set of 3
(f) Coper Bus bar 300 Amps rated of suitable size -one set
Taking down old unserviceable and M&L for fabrication of Panel, double door made out of 2mm thick CRCA sheet, CPRI approved, indoor type suitable for 3 phase, 4 wire, 415 volts, individual compartment for MCCBs and Coper busbar of 200 amps capacity alongwith compartment for fixing of with necessary clamps, nuts, bolts and washers, internally prewired with all connecting accessories, floor mounted type made with angle iron legs 40x40x4 mm thick, powder coated painting incl foundation 60 cms above the ground level in PCC 1:3:6 type C2 all as specified & Directed consisting of following :-
Incomer : (a) MCCB 200 Amps, 4 Pole, 36 kA, thermal magnetic release, Ics=100% Icu - 01 Nos,
Outgoings :
(b) (a) MCCB 63 Amps, 3 Pole, 16 kA, thermal magnetic release, Ics=100% Icu - 05 Nos ( 04 for lift & 01 spare )
(c) Digital Ammeter - 01 Nos
(d) Digital Voltmeter - 01 Nos
(e) Phase indicator lamp R,Y & B - Set of 3
(f) Coper Bus bar 200 Amps rated of suitable size - Set
S & F junction box of size not less than 4x4 inch with connector encloser, 3 terminal/ PVC/ polycarbonate, isolated body including taking out old one.
S&F in repairs LED 45 Watts (min 120 lumen/watt) building street light in Aluminium PDC housing, toughened glass cover in IP66 protection with 3000 (k) including connecting light with three core copper wire from connector or ceiling rose.
S&F street light bracket bend to shape made as required of 25mm dia, GI pipe light grade fixed to pole/ Wall including M&L for fixing with the help of flat iron clamp with the help of nuts and bolts for fixing of street light fitting on the wall complete after taking out old U/S one all as specified and as directed.
S&F in repairs PVC insulated three core PVC sheathed 2.5 Sqmm stranded copper conductor cable for connecion from DB to connector junction box for power supply to security light fittings drawn in PVC conduit not less than 20mm dia
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm or nearest size.
Taking down deterioted louvers and supplyinh and fix new louvers fixed type made out of 1.6 mm GI sheet with horizontal ventilation, bending into shape of size 45cm x 45 cm (outer) with 20x3 mm flat iron base of size 45cmx 45cm complete by providing fixing arrangement for louvers upto 9 floor complete all as specified and as directed.
Supplying and laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size 240 sqmm 3.5 core laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles and taking out old u/s damaged cables.
Supplying and laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size 150 sqmm 3.5 core laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles and taking out old u/s damaged cables.
Supplying and laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size 70 sqmm 3.5 core laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles and taking out old u/s damaged cables.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 1100 volts grade, of size 2.0 core 10 sq mm.
Supply and erect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) all as directed incl dismantling old one. Note :- Earth work, Cement concrete in foundation, coping etc will be measured and paid separately under relevant item.
Excavation in trenches not exc 1.5 mtr wide and exc1.5 mtr but n exe 3m in depth for laying of cables etc. in any type of soil and getting out all as specified and directed by Engineer-in-Charge. Note : Rate includes removing of paver blocks carefully and stack properly for refixing after laying of cables .
M&L for 110mm bore High density poly-ethylene pipes (HDPE) of pressure rating PN 6(0.6 Mpa), (material grade PE 63), for road crossing of cable or for cable protection laid in trenches or above ground surface all as specified and directed.
M&L for 50mm bore High density poly-ethylene pipes (HDPE) of pressure rating PN 6(0.6 Mpa), (material grade PE 63), for road crossing of cable or for cable protection laid in trenches or above ground surface all as specified and directed.
M&L for PCC 1:4:8 type D2 with 40 mm graded aggregate as in foundation complete.
M&L for PCC 1:3:6 type C1 with 20 mm graded aggregate for coping of poles and stay including form work.
S&F GI pipe 32 mm light grade with all fitting fixed to electric pole for cable protection with suitable size GI clamp, nut bolt and washers all as directed.
S & F street light bracket bend to shape made as required of 40mm dia 1.5mtr long GI pipe medium grade fixed to pole/ Wall including M&L for fixing with the help of flat iron clamp of size 40x6mm two numbers with the help of nuts and bolts for fixing of street light fitting and making all electric connection with two core 2.5 Sqmm copper wire from MCB to switch point complete all as specified and as directed.
M & L for looping box of size 260mm x 210 mm x 116mm including connector for in & out 35sqmm 3.5 core cable, MCB SP 10 Amps for independent for in/out cable and looping box to be fitted with pole with the help of flat aluminium clamps not less that 25mm x 3mm with suitable size nuts, bolts and washers complete all as specified and directed. .
S & F LED 120 Watts (min 110 lumen/watt) street light in Aluminium PDC housing, toughened glass cover in IP66 protection complete all as specified and as directed.
Taking down old unserviceable and M&L for fabrication of Panel, double door made out of 3.15mm thick CRCA sheet, CPRI approved, outdoor type suitable for 3 phase, 4 wire, 415 volts, individual compartment for MCCBs and Coper busbar of 1000 amps capacity alongwith compartment for fixing of with necessary clamps, nuts, bolts and washers, internally prewired with all connecting accessories, floor mounted type made with angle iron legs 40x40x4 mm thick, powder coated painting incl foundation 60 cms above the ground level in PCC 1:3:6 type C2 all as specified & Directed consisting of following :-
Incomer : (a) MCCB 630 Amps, 4 Pole, 50 kA, thermal magnetic release, Ics=100% Icu - 01 Nos,
Outgoings :
(b) (a) MCCB 200 Amps, 4 Pole, 36 kA, thermal magnetic release, Ics=100% Icu - 06 Nos ( 04 for meter cabin panel & 01 for Lift panel and 01 spare )
(c) Digital Ammeter - 01 Nos
(d) Digital Voltmeter - 01 Nos
(e) Phase indicator lamp R,Y & B - Set of 3
(f) Coper Bus bar 1000 Amps rated of suitable size - Set
(g) Analog time switch -01 Nos
Supply and fixing post top lantern LED type 40 watt (min 120 lumen/watt) 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete.
Cutting existing road surfaces or hard standing 45 cm depth, 45 cm wide (22 thick comprising bituminuous topping) for laying of pipes/cables and making good disturbed surfaces to match with existing surfaces using PCC 1:2:4 type B1
Taking down old unserviceable aviation light fittings from roof surfaces of G+08 bldg and Supply & fixing of Twin LED aviation light comprising of aluminium housing with polycarbonate diffuser, enclosed with glass cover in frame (with total lumen output not less than less than 100 lumens/Watt) with ingress protection IP 65 and surge protection device of 5 KV capacity etc incl necessary, angle iron supports , clamps etc for installation complete and testing on completion all as specified and as directed.
Taking out old broken air termination, single pointed aluminium rod of any dia fixed over the GI Tube with the clamps.
Material & labour for CPT Cirprotec CPT-L ESE lightning rod with stainless steel body type advance lightning protection system in compliance with standard NFC 17-102 & UNE 21186-96, working on the principle of early streamer emission technology which will offer level 1 protection for up to 42 mtrs radius when mounted on the RCC concrete base on building at a height of 4.5 mtrs from the place to be protected including taking out old, U/S lightning rod complete all as directed by Engineer-in-Charge. Make- NIMBUS-JEF Techno or technocommercial equivalent make.
Taking out old, GI tube of any dia complete.
Supply and erection of mounting structure of 4.5 mtrs height with base plate suitabe for roof mounting on RCC concrete base on building including taking out old, U/S one complete all as directed by Engineer-in-Charge. Make- NIMBUS-JEF Techno or technocommercial equivalent make.
Taking out old, broken Aluminium strip of size 25 x 3mm fixed on walls/roof top with saddles and screws complete.
Supply & fixing of single core PVC insulated and PVC Innersheathed cable with aluminium conductor cable size 1x70 Sqmm 1100 Volt grade stranded aluminium conductor after taking out old, U/S earthing strip complete all as specified and as directed.
M&L for Galvanised steel tubes 25mm bore, light grade for protection of single core PVC insulated 70 sqmm unarmoured aluminium cable fixed on external wall surfaces of G+5 bldgs by proper clamping from roof to bottom complete all as directed.
M&L for PVC conduit pipe 25mm bore, medium mechenical stress for protection of single core PVC insulated 70 sqmm unarmoured aluminium cable fixed on external wall surfaces of G+5 bldgs by proper clamping from roof to bottom complete all as directed.
Supply and fixing 4 digital electromechanical lightning even counter in weather proof resistance including taking out old, U/S copper strip complete all as directed by Engineer-in-Charge.
Taking out old, broken/unserviceable earth testing point of any type complete.
Supply and fixing test link box for each downconductor in order to disconnect the earth termination system to enable measurement of resistance.
Taking out old, unsrviceable earthing complete with earting material.
Material and labour for maintainance free environment friendly earth electrode set comprising of 17.2mm dia, 3 mtrs long rod of low carbon steel molecular copper bounded for a thickness of 250 micro OHMS, highly conductive ANSI/NSF STD-60 certified carbon bound backfill compound which shall set like concrete according to BS 7430 & IEEE 80 (each bag shall contain 50 lbs) after taking out old, U/S one complete all as directed by Engineer-in-Charge. Make- JEF Ecosafe or technocommercial equivalent make.
Supply and fixing in repair/ replacement of internal steel water tubing, galvanised, Medium grade with all fittings such as nipple, union, socket, elbow, bends, fixed to wall including work to be done up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/ on wall including concealed pipe and making good the disturbed surfaces to match previous structure with complete all as specified and directed by Engineer-in-charge of following size :- Note :- All internal water pipe/ tube to be concealed
(a) 80 mm bore
(b) 50 mm bore
(c) 40 mm bore
(d) 25 mm bore
(e) 20 mm bore
(f) 15 mm bore
Supply, fixing and laying in repair/ replacement of CPVC pipes 20 mm nominal bore SDR 11 & Plain CPVC SDR 11 fittings such as nipple, union, socket, elbow, bends, tee, adopter e.t.c fixed to wall/floors/ceiling including work to be done up to 15 th floor in high rise buildings and low rise buildings in short piece/length all as specified and directed by Engineer-in-charge. Note :- Pipes to be concealed and rate shall be included in the rate quoted by the bidder
Supply and fix in replacement of Gun-metal ball valves (ISI marked) 80 mm bore Screwed female thread both ends IS 554 parallel for iron pipe all as specified and directed.
Supply and fix in replacement of Gun-metal ball valves (ISI marked) 50 mm bore Screwed female thread both ends IS 554 parallel for iron pipe all as specified and directed.
Supply and fix in replacement of Gun-metal ball valves (ISI marked) 40 mm bore Screwed female thread both ends IS 554 parallel for iron pipe all as specified and directed.
Supply and fix in replacement of Gun-metal ball valves (ISI marked) 15 mm bore Screwed female thread both ends IS 554 parallel for iron pipe all as specified and directed.
Supply and fix in replacement CP cast copper alloy stop cock fancy type, chrome plated, screwed down with crutch or butterfly handle suitable for GI tubing 15 mm dia bore or 20 mm outer dia CPVC pipe including necessary fittings, clamp & saddles all as specified .
Supply and fix in replacement CP cast copper alloy bib cock, with crutch or butterfly handle screwed both ends for GI tubing 15 mm dia bore or 20 mm outer dia CPVC pipe including necessary fittings, clamp & saddles all as specified .
Supply and fix in replacement angle cock for GI tubing 15 mm dia or 20 mm outer dia CPVC pipe including necessary fittings,clamp & saddles etc all as specified.
Supply and fix in replacement concealed CP cast copper alloy stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends suitable for GI tubing 15 mm dia bore or 20 mm outer dia CPVC pipe including necessary fittings, clamp & saddles all as specified .
Supply and fixing efficient water heater storage type (five-star rated as per BEE) standing loss as per IS 2082 (latest amendment), vertical electric supplied and installed complete capacity of 10 Ltr including copper tank, flexible type for hot and cold water, dead weight pressure release valve, Anchor fastener 4Nos of suitable size all as specified and directed. Rate is inclusive of plug top, hot water extension pipe and geyser body should not be inbuilt type i.e. Body can be opened complete all as specified and directed
Supply & fix in repair of PVC(LLDPE) rectangular loft tank of net capacity 275 Ltrs with gross capacity of tank at least 5% in excess of minimum net capacity including 03 Nos adopter with washer for inlet/outlet overflow pipe as per manufacturere s instruction and overall dimension as 995-1200mm length , 620-820mm with 285-485mm height , 300mm internal dia of hand hole,minimum wall thickness 2.75mm( weight of tank 11 Kgs) with lid cover complete all as specified and directed by Engineer-in- Charge.
Supply and fixing PVC profile suitable for 275 ltrs loft tank including fixing of aluminium channel around the profile complete all as specified and directed.
S&F in repair SMC PANEL TANK confirming to Panel must be ISI Marked and have ISI Logo with CML and Batch Number along with ISI Code.(ISI 14399 Part-1 & Part-11-2006) of the under mentioned size (3mt x 2mt x 2mt) and capacity (12 KL.) Made out of HOT PRESS MOULDED SHEET MOULDING COMPOUND (SMC) Panels of size 1005mm X 1005 mm. The flange should be perpendicular to the main surface. The shape should be Trunk Type for extra strength and 90 degree flanges predrilled for bolting. All the Flanges of the Panel should have maximum 13 Nos. holes for fastening/joining the panels to one another. Hot Pressed Moulded SMC Pre Drilled Corner Pieces with built-in ribs of the size 75mm X 75 mm should be provided for 90 degree joints of tank walls or wall to base or wall to roof joints complete Hot Dipped Galvanized (HDG) hardware nuts, bolts and washers. Special sealant having excellent UV Resistance as well as suitable for portable water, complete with Top Covered construction having Man-Hole with Cover of Dia 600mm and internal FRP Ladder. The tank after erection and assembled as per Manufacturer Specification's shall be filled with water upto overflow level, which will be placed near the roof of the tank and test for leakages rectified any leakage found during the testing should be rectified to make it 100% leak proof complete as per direction of Engineer-in-Charge. (ISI Logo & CML number must be printed on all Panels). Make : Sintex Code No GS-PT-010-S2.5 or technocommercial equivalent model of make in M/s BT composite Ltd / M/s Mahindra composite Ltd. NOTE: (i) Rate quoted shall deemed to be inclusive of internal and external ladder made out of GRP/ Pultruted Section and necessary modifications or demolition to RCC foundation if required. MS supporting channels and necessary PVC profile including FOUNDATION, GRILLAGE, UNLOADING, SHIFTING & OTHER CIVIL COMPONENT IN CLIENT SCOPE Deduction for dismantled material received after dismantling of old pipes/structures.
Supply and fixing in repair/replacement bronze pressure reducing valve suitable for 40 mm bore GI pipe with diaphram cover, spring clamps, cast iron body scatting and adjustable screws and stop valve of chromium plated carbon steel strainer, screw of stain less steel for domestic water supply, suitable for inlet pressure as per IS-7939, including GI pipe connection as required, the work to be carried out from G+14 floor on plain wall with necessary bamboo scaffolding complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement of Brass CP mixer 3 in 1 of size 15 mm for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed by Engr-in-Charge
S&F in replacement of shower rose CP 125mm dia swivel type suitable for 15mm bore GI tubing complete all as specified and directed by Engr-in-Charge
Supply and fix in replacement of automatic water level control/ float valve inside type top inlet mattle exterior finish outlet connection BSPT type max operationg pressure 98066 pascal used for water tank complete screwed for GI pipe 15mm bore/ CPVC pipe 20 mm bore including necessary GI/ CPVC fittings such as elbow, reducer, nipple etc. complete all as specified and directed by Engr-in-Charge
S&F in replacement Shower arm 15 mm size, 195mm long with bend of 45 degree with flange of PTMT (min weight 40 gms) any colour complete all as specified and directed by Engr-in-Charge
Taking down and dismantling old unserviceable pumping sets-02 Nos and making good to disturbed surfaces as per existing complete all as specified and directed
Supplying, installation, testing and commissioning of Electric driven Pump factory fitted with below requirements complete all as specified and directed by Engineer-in-Charge. (a) 2400 LPM at head of 45 Mtr, Horizontal type, centrifugal, split casing pump body made up of cast iron & enclosed type impeller made up of bronze with stainless steel shaft,with suitable sealing, glands packing conforming to IS 1520. (b) Suitable Squirrel cage IE-2 induction motor ,TEFC, synchronous speed 1500 RPM, suitable for operation. on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate,coupling guard, Pressure guage upto 6kg/cm2 of size 100mm dia with accuracy + 2% of foundation bolts etc. as per manufacturer's instruction. (d) Suitable cement concrete foundation (height shouldn't be less than 20 cm) duly plastered with anti vibration pads,painting of blue colour to suction and delivery pipe line, MS common base plate coupling guard. (e) One coat of red lead primer of best quality (IS approved ) shall be applied. Finally two (2) coats of Synthetic enamel paint of best quality(IS approved) colour shall be applied Note:submitting pump performance curves and pump efficiency at site (f) Inspection of pump sets at the factory by detailed rep before dispatch. Rate is inclusive PCC foundation and making good disturbed surface
Supply and fixing in repairs MS Pipe 100 mm bore confirming to IS 1239 Part-I (2004) including nut, bolts, washer, flanges, gaskets, wleding works etc equivalent to BS 1387/1985 heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer complete all as specified and directed Note: Pipe laid in trench will be wrapped with bituminous tape/ coating of thickness 3 mm as per IS Code 15337: 2003
Supply and fixing of Tubes, 'medium grade, galvanised 80 mm(3") bore with all fitting fixed complete to walls and ceilings or laid in floors complete all as specified and directed
Supply and fixing of Tubes, 'medium grade, galvanised 50 mm (2") bore with all fittings fixed complete to walls and ceilings or laid in floors complete all as specified and directed
Supply and fixing in repair foot valve (ISI marked) ball type or flanged type in existing location or new position or location in the sump of any capacity including making of flanged joints , nut bolts washers rubber gasket welding work flange joints etc and repair making good to existing PCC surface conforming to IS 4038, 100 mm(4") dia complete all as specified and directed
Supply and fixing in replacement of Cast Iron Air release valves (ISI Marked) with two air outlets, 100 mm bore and fixing up in cast iron water supply mains complete all as specified and directed
Supply and fixing in repair of ball valves (ISI Marked) high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed flat type for iron pipe and fixed 40 mm bore all as specified and directed.
S & F in repair pressure gauge 150mm dia range 0-25 Kg /Sqcm Oil filled type as per sample. Note: quoted rated should including for providing of adopter /Ferrule/check nut etc required for fixing pressure guage and necessary alterations to MS or CI pipe for taping if required all as specified and directed.
S&F in repair 100 mm bore sluice valves (ISI marked) flanged end, cast iron body, flanged and drilled and non rising type brass spindle with nut, long body, class P N 1.6, confirming to IS 14846 of 2000 for following sizes including all flange joint with rubber or fiber board, bolts, nuts, washers welding works complete including pumping out accumulated water all as specified and directed
S&F in repair 80 mm bore sluice valves (ISI marked) flanged end, cast iron body, flanged and drilled and non rising type brass spindle with nut, long body, class P N 1.6, confirming to IS 14846 of 2000 for following sizes including all flange joint with rubber or fiber board, bolts, nuts, washers welding works complete including pumping out accumulated water all as specified and directed
Supply & fixing in repair Non return valve 100mm size, ISI marked, both ends flanged with high tensile stainless steel spindle, CI body including all joints with rubber or fibre board, nuts, bolts, washers complete all as specified and directed.
Supply & fix in repair Non return valve 80mm size, ISI marked, both ends flanged with high tensile stainless steel spindle, CI body including all joints with rubber or fibre board, nuts, bolts, washers complete all as specified and directed.
Taking down unserviceable GI Pipe 100/80/50 mm dia
Taking down old unserviceable panel with all items of any size as specified and directed by the Engr-in-charge
Supplying, installation, testing and commissioning of Electric driven Pump factory fitted with below requirements complete all as specified and directed by Engineer-in-Charge. (a) 1620 LPM at head of 70 Mtr, Horizontal type, centrifugal, split casing pump body made up of cast iron & enclosed type impeller made up of bronze with stainless steel shaft,with suitable sealing, glands packing conforming to IS 1520. (b) Suitable Squirrel cage IE-2 induction motor ,TEFC, synchronous speed 1500 RPM, suitable for operation. on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate,coupling guard, Pressure guage upto 6kg/cm2 of size 100mm dia with accuracy + 2% of foundation bolts etc. as required. (d) Suitable cement concrete foundation (height shouldn't be less than 20 cm) duly plastered with anti vibration pads,painting of blue colour to suction and delivery pipe line, MS common base plate coupling guard. (e) One coat of red lead primer of best quality (IS approved ) shall be applied. Finally two (2) coats of Synthetic enamel paint of best quality(IS approved) colour shall be applied Note:submitting pump performance curves and pump efficiency at site (f) Inspection of pump sets at the factory by detailed rep before dispatch. Note : Rate shall be inclusive of dismantling the existing foundation and making new one as per manufacturer instrcutions and directed by GE.
Supply and fixing Jockey pump horizontal end suction centrifugal type Confirming to IS- 12469: 1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for automatic operation with nonover loading power characteristics for frequent start / stop operations for 440 V , 3 phase, 50 Hz 70 m head 180 LPM discharge complete all as specified and directed. Note : Rate shall be is inclusive of dismantling the existing foundation & making new one as per manufacturer instrcutions and directed by GE.
Supply, install testing and commissioning of Booster pumps for 440 V, 3 Phase, 50 Hz Confirming to IS- 12469 :1988, Size (mm) Suction x delivery : 80 x65 mm With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz 35mtr head, 900 LPM discharge including PCC foundation not less than 20 CM height, pump fixed on angle iron base frame from the manufacturer size and model with vibration pads, PVC insulated and sheathed three core cable of suitable size from starter to pump and Fibre sheet 2 mm thickness for shed not less than 4 sqm with angle iron as required at site for protection of pump from rain and water complete all as specified and directed. Make :- Kirloskar Model No. KDI-1555+ CI MS SS IP55 FCL or technocommercial equivalent in CG Note :- The item rate shall includes PCC foundation, Fibre sheet, angle iron frames, Pump base frame, vibration pads, grouting of nut bolts and three core cable from starter to pump as required at site including testing.
Supply and fixing in repairs MS ERW pipe 100 mm bore heavy grade, ISI marked IS 1239 for suction and delivery for pump and for rising main including necessary fitting including welding, painting with red oxide primer & two coat of synthetic enamel paint and providing necessary PCC support, all as specfied and directed by Engineer-in-charge Note: Pipe laid in trench will be wrapped with bituminous tape/ coating of thickness 3 mm as per IS Code 15337: 2003
Supply and fixing in repairs MS ERW pipe 80 mm bore heavy grade, ISI marked IS 1239 for suction and delivery for pump and for rising main including necessary fitting including welding, painting with red oxide primer & two coat of synthetic enamel paint and providing necessary PCC support, all as specfied and directed by Engineer-in-charge Note: Pipe laid in trench will be wrapped with bituminous tape/ coating of thickness 3 mm as per IS Code 15337: 2003
Supply and fixing in replacement of Tubes , 'medium grade, galvanised 25 mm bore with all fitting fixed complete to walls and ceilings or laid in floors
Supply and fixing in repair of Gun metal fire brigade in let connection for connecting to external fire hydrant ring main consisting of two nos 63mm dia instantaneous type male coupling with built in check valves and 80mm dia, flanged outlet complete with all accessories.
S&F in repair sluice valve (ISI Marked) 100 mm size both ends flayed with high tensile stainless steel spindle, I body as per IS-14846, ISI Marked,PN-1.6 including all joints with rubber or fibre board, nuts, bolts, washers complete all as specified and directed.
Supply and fixing in repair of valve (ISI Marked) , Non return valve (NRV), 80mm(3") dia complete all as specified and directed.
Supply and fixing in repair Foot valve (ISI Marked) 80 mm size ball type10/15Kg/sqcm of ISI marked in position at location including M&L for making flanged joints and repair and making good to existing PCC surface conforming to IS 4038 complete all as specified and directed.
Supply and fixing in repair Foot valve (ISI Marked) 100 mm size ball type10/15Kg/sqcm of ISI marked in position at location including M&L for making flanged joints and repair and making good to existing PCC surface conforming to IS 4038 complete all as specified and directed.
Supply and fixing in replacement of Cast Iron Air release valves with two air outlets, 80 mm bore and fixing up in cast iron water supply mains complete all as specified and directed.
S & F in repair pressure gauge 150mm dia range 0-25 Kg /Sqcm Oil filled type as per sample. Note: quoted rated should including for providing of adopter /Ferrule/check nut etc required for fixing pressure guage and necessary alterations to MS or CI pipe for taping if required complete all as specified and directed.
Supply and fixing in repair of Gun-metal, ball valves (ISI marked) of size 20 mm bore of pipe, with iron hand, screwed both ends complete all as specified and directed.
Supply and fixing in repair of Gun-metal, ball valves (ISI marked) of size 25 mm bore of pipe, with iron hand, screwed both ends complete all as specified and directed.
Supply and fixing in repair of Rotational moulded polye?thylene water storage tanks 250 Ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position all as complete all as specified and directed by Engr-in-Charge.
Supply, laying in repair including testing cable XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with strandard aluminium conductor of size 6 sq mm 4 core complete all as specified and directed by Engr-in-Charge.
Supply & fixing in repair twin outlet hydrant valve , made of brass, 100 mm having 63 mm outlet with lock pin wheel complete all as specified and directed. Make:- Minimax / Safex / DUNLOP conforming to IS 5290 complete all as specified and directed by Engr-in-Charge.
Supply & fixing in repair single outlet hydrant valve, made of brass 100 mm having 63 mm outlet with lock pin wheel complete all as specified and directed. Make:-Minimax / Safex / DUNLOP conforming to IS 5291 complete all as specified and directed by Engr-in-Charge.
Material and labour factory fabricated Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard fixed on wall with necessary nuts/bolts or welding to existing MS pipe by supporting angle complete all as specified and directed by Engr-in-Charge.
Supply & fix in repair rubber hose pipe 30 mtr, 20mm dia plain 2 ply rayon braided high pressure complete all as specified and directed. Make:-Minimax/Safex/DUNLOP conforming to IS 5132
Supply & fix in repairs Branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 15mm bore nozzle complete all as specified and directed conforming to IS 903. Make :- Minimax / Safex / Dunlop
Supply and fix in replacement of branch pipe with nozzle of 20 mm dia for hose reel conforming to IS 8090
Supply & fix in repair canvas fire hose red in colour 63mm bore 15 m long confirming to IS 636-1988 having male/female brass coupling both end complete all as specified and directed. Make:-Minimax/Safex/Dunlop conforming to IS 903
Supply and fix in replacement of fire hydrant stand post with provn of single outlet conforming to IS 908
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of alvanised iron or steel all as specified and shown in electrical plate No. 3 connected to earthing test point including testing on completion
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire
Supply and replacement, installation, testing & commissioning of addressable micro processor based 2 wire fault tolerant loop, required loop net workable type Single loop (each loop accessing maximum 99 detectors and 99 modules) fire alarm/detection control panel. The panel shall be able to give location of all fire/fault signal with address. The panel shall have rectifier, loop cards, LCD display unit to indicate Fire/Fault signal with address. The panel shall have a built in power supply and battery charger alongwith maintenance free SMF lead acid batteries as per manufacturers design with battery charger complete as required and as per specifications duly approved by EN 54 complete including making connections all as specified and directed by Engr-in-Charge. Make :- Morley-IAS by Honeywell model Name/Number. DXc2/ 714-001-225 or Bosch model No. FPA-1000-V2 / Apollo model No. Elite RS 10860-10
Supply and fix in repair Addressable manual call point resettable type complete all as specified and directed Make :- Morley-IAS by Honeywell/Bosch/Apollo
Supply and fixing in repair detectors Complying with and type certified to EN - 45 Addressable type optical multi Sensor detector heat and smoke combination Photoelectric /Optical with base with self built intelligence as per IS: 11360 complete all as specified and directed. Make :- Morley-IAS by Honeywell/Bosch/Apollo
Supply and fix in repair Addressable sounder range 900 dbl with strobe complete all as specified and directed Make :- Morley-IAS by Honeywell/Bosch/Apollo
Supply and fixing in repair red colour PVC insulated PVC sheathed armoured copper conductor cable of size 2Core x 1.5 Sqmm including fixing on walls with saddles not more than 60 cm intervals complete all as specified and directed. Make :- Plaza/Polycab/Gloster
Supply & fix in repair hose Reel drum with mounting base plate company made suitable for 30 mtrs X 20 mm dia rubber hose pipe complete all as specified and directed. Make:-Minimax/Safex/Dunlop Note : Rate is inclusive of providing shank reducer and making all possible connection with pipe and rubber hose
Supply and laying in repair XLPE insulated,PVC outer sheathed ,single core copper cable of size 70 Sqmm in HDPE pipe of size 50 mm bore concealed in floor clamped in wall/trench between motor terminal and starter panel complete all as specified and directed by Engineer-in-Charge. Note :- Excavation & pipe shall be measured and paid separately
Supply and laying in repair XLPE insulated,PVC outer sheathed ,single core copper cable of size 25 Sqmm in HDPE pipe of size 50 mm bore concealed in floor clamped in wall/trench between motor terminal and starter panel complete all as specified and directed by Engineer-in-Charge. Note :- Excavation & pipe shall be measured and paid separately
Supply and Fix in repair MCCBs 40 Amp 3 pole 415 volts, 16KA, 50 HZ including factory made SS enclosure fixed on wall and making connections complete all as specified and directed
Supply and fixing in repair MCB double pole 16 Amps, 10 KA, 'C' series with factory made SS enclosure fixed on wall and making connections complete all as specified and directed.
Taking down and dismantling old unserviceable fire pump sets- 02 Nos and making good to disturbed surfaces complete all as specified and directed
M & L in repair for Pressure switch Universal type with suitable pressure range having die cast aluminium construction and SS sensing element with ball valve, fittings viz. unions, collars, reducers etc.existing header for fire pumpsets, wiring up to Motor Control Centre complete all as specified and directed by the engineer-in-charge.
M & L for providing 40 mm thick precast cement concrete PCC 1:2:4 type B0 (12.50 mm graded stone aggregate) louvers and jallis, measured solid set in CM 1:4, including all mouldings but excluding frame complete all as specified and directed by the Engr-in- charge
AGRAWAL ASSOCIATES (BID ID -3417176)
Shetty Construction Co (BID ID -3426064)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ_808887.xls
BOQ • 0.51 MB
176680058.pdf
Tender Documents • 0.61 MB
176680060.html
Tender Documents • 0.06 MB
178492727.pdf
Tender Documents • 0.34 MB
179313577.pdf
Tender Documents • 0.25 MB
8215.rar
Tender Documents • 4.51 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .