Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹22.5 CrAccepted-AOC 9 KRISHNA VIHAR NEAR CHUNGI NAKA NANTA ROAD KUNHADI KOTA 324008 | KOTA | KOTA | RAJASTHAN | 324008 | ₹22.5 Cr Quoted ₹23.0 Cr | L-1 | Accepted-AOC As per decision of PC-WTD |
| 2 | L-2₹23.3 CrRejected-AOC 301 306 PANORAMA COMPLEX R C DUTT ROAD VADODARA VADODARA GUJARAT 390007 | VADODARA | GUJARAT | 390007 | ₹23.3 Cr | L-2 | Rejected-AOC As per decision of PC-WTD |
| 3 | L-3₹23.8 CrRejected-AOC | ₹23.8 Cr | L-3 | Rejected-AOC As per decision of PC-WTD |
| 4 | Rejected-Technical | - | - | Rejected-Technical Techno-commercial disqualified |
Tender Value
₹21.6 Cr
EMD Value
₹43.1 L
Closing Date
16 Jul 2024, 4:00 pmClosed
SE (AUTOMATION, N/M, SP)
VIDYUT BHAWAN, JYOTI NAGAR, JAIPUR
Up-rating and refurbishment of existing 132 KV lines using HTLS conductor with associated works in Jaipur EHV Network
2024_RRVPN_389174_1
RVPN/EHV/ASP/TN-118
Open Tender
Electrical Works
365 days
JAIPUR
Please refer Tender documents.
4 documents required · 4 mandatory
₹17,700
SR AO (EA AND CASH) RVPN
₹43.1 L
JAIPUR
26 Oct 2024
16 Mar 2024
16 Jul 2024
29 Apr 2024
16 Jul 2024
20 May 2024
7 May 2024
Cost of Material/ Equipment HTLS Transmission Lines
HTLS equivalent to ACSR Panther conductor
HTLS Conductor (eq. to Panther) as per specification requirements
Hardware Fitting/ Accessories for HTLS equivalent to ACSR Panther conductor
Single Suspension Hardware Fittings (Complete Set with Preformed Armour Rod for above mentioned Conductor)
Double Suspension Hardware Fittings (Complete Set with Preformed Armour Rod Rod for above mentioned Conductor)
Single Tension string Hardware Fittings (Complete Set for above mentioned Conductor)
Double Tension string Hardware Fittings (Complete Set for above mentioned Conductor)
Single Suspension Fitting for Pilot String (Complete Set with Preformed Armour Rod for above mentioned Conductor)
Repair Sleeve
Mid Span Compression Joint
Vibration Dampers
T Clamp
Terminal Pad without Hole
Replacement of Damaged/broken Disc Insulators during refurbishment of Line
Galvenized Steel Structures
Required strengthening of existing Tower Cross Arms, additional Towersetc. for meeting the required ground & safety clearance requirements after laying new offered HTLS conductor as per various spans mentioned in the enclosed Tower Schedule of various lines in the technical specification.
Material/ Equipment for 132 kV Terminal Bays and associated Bus sections
132 kV 1250 A HDB Motorized Isolators with EB
Post Insulators for above Isolator
132 kV 1250 A HDB Motorized Isolators without EB
Post Insulator for above Isolator
132 kV Current Transformer (1000/ 1A 3C)
132 kV Current Transformer (1000/ 5A 3C)
0.5 mH 1250 A Wave Trap
132 Kv Bay Interconnection with Line & Bus
ACSR Zebra
Clamp/ Connectors (Twin Zebra)
Wave Trap
T-Connector (Twin Zebra- Single Zebra)
T-Connector (Single Zebra- HTLS)
DT Hardware for Twin Zebra (with Turn-buckle)
DT Hardware for Twin Zebra (without Turn-buckle)
SS Hardware for Twin Zebra
Bolted Type Tesnsion Clamp for Twin Zebra
Bolted Type Suspension Clamp for Twin Zebra
T-Connector (Zebra - Zebra)
PG Clamp (Zebra - Zebra)
T Clamp (Zebra -Panther)
PG Clamp (Zebra -Panther)
Spacer (Zebra-Zebra)
Clamp/ Connectors (Single Zebra)
Replacement of Damaged/broken Disc Insulators during refurbishment of Line & Substation Bay/ Bus
Fabrication Steel for Srenghtening/ raising height of structures at terminal substations
Earhting (MS/GS Flat with clamp & accessories)
220 kV GSS Mansarovar
220 kV GSS VKIA
220 kV GSS Heerapura
132 kV GSS Chambal
132 kV GSS VKIA
132 kV GSS Vaishali Nagar
Power & Control Cables
220 kV GSS Mansarovar
220 kV GSS VKIA
220 kV GSS Heerapura
132 kV GSS Chambal
132 kV GSS VKIA
132 kV GSS Vaishali Nagar
MANDATORY SPARES
HTLS Conductor (eq. to Panther) as per specification requirements
Hardware Fitting/ Accessories for HTLS equivalent to ACSR Panther conductor
Single Suspension Hardware Fittings (Complete Set with Preformed armour Rod for above mentioned Conductor)
Double Suspension Hardware Fittings (Complete Set with Preformed armour Rod for above mentioned Conductor)
Single Tension string Hardware Fittings (Complete Set for above mentioned Conductor)
Double Tension string Hardware Fittings (Complete Set for above mentioned Conductor)
Single Suspension Fitting for Pilot String (Complete Set with Preformed Armour Rod for above mentioned Conductor)
Repair Sleeve
Mid Span Compression Joint
Vibration Dampers
T Clamp
Terminal Pad without Hole
Add any other item required to complete the supplies for completion of work as per specification requirements
Description of Work / Item(s)
Survey of existing Transmission Lines alongwith Bays and Buses at terminal substations
Survey of 132 kV Transmission Lines for Uprating Work
Survey of Terminal Substation for Uprating & Upgrade works
ETC services for 132 kV Transmission Lines
Dismatling of exsiting ACSR Panther conductor with hardware fittings
Erection of HTLS conductor with associated hardwares and accessories as per technical specification
ETC services for strengthening of existing 132 kV Bays/ Buses at terminal substations
Replacement of of 132 kV Bay equipments (Dismantlling as well as Erection including cabling & earthing requirements as required for commissioning)
132 kV 1250 A HDB Motorized Isolators with EB/ Without EB alongwith PI
132 kV CT (1000/ 1A or 5A 3C)
0.5 mH 1250 A Wave Trap
Upgrading/ uprating of Bays for [ including dismantalling of existing conductor, erection of new conductor configuration as specified with required clamps, connectors and clamps etc. with interconnection to Uprated lines (for Line Bays)
132 kV Line Bay
132 kV Bus coupler Bay
Uprating/ Upgrade of Bus-sections
Uprating/ upgrade of Bus-sections (Including Dismantalling of existing Bus and re-erection of new bus with specified conductor configuration (For Standard bus section: 04 bays)
Interconnections of bays with jumpers associated with the upgraded/ up-rated bus section
Required strengthening of existing Tower Cross Arms, additional Towers etc. for meeting the required ground & safety clearance requirements after laying new offered HTLS conductor as per various spans mentioned in the enclosed Tower Schedule of various lines in the technical specification [ including dismantalling of existing towers, if required]
Fabrication Steel for Srenghtening/ raising height of structures at substations
Earhting works at terminal substations
220 kV GSS Mansarovar
220 kV GSS VKIA
220 kV GSS Heerapura
132 kV GSS Chambal
132 kV GSS VKIA
132 kV GSS Vaishali Nagar
Power & Control Cables works at terminal substations
220 kV GSS Mansarovar
220 kV GSS VKIA
220 kV GSS Heerapura
132 kV GSS Chambal
132 kV GSS VKIA
132 kV GSS Vaishali Nagar
Add any other item required to complete the Services for completion of work as per specification requirements
Maintenance Service [these charges shall be applicable after the completion of garaunteed performance period of Uprated Lines for 3 years. The charges shall be paybale on actuals
Maintenance services per visit towards any breakdown of uprated line which includes services of expert engineers, technicians alongwith necssary tools/ tackles for its rectification, re-testing and restoring the electric supply through uprated line
APAR INDUSTRIES LIMITED
JSK Industries Private Limited
JSK Industries Private Limited
APAR INDUSTRIES LIMITED
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid