| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.5 LAccepted-AOC | L1 | Accepted-AOC Lowest rate quoted | |
| 2 | L2₹40.9 L+₹8,154 (0.20%)Rejected-AOC SOUTH CANEL PAR PO PANAGARH BAZAR DISTT PASCHIM BARDWAN WB PIN 713148 | PANAGARH BAZAR | PASCHIM BARDWAN | WEST BENGAL | 713148 | L2 | Rejected-AOC Higher rate quoted than L1 | |
| 3 | L3₹42.7 L+₹1.8 L (4.52%)Rejected-AOC | L3 | Rejected-AOC Higher rate quoted than L1 | |
| 4 | L4₹48.2 L+₹7.4 L (18.1%)Rejected-AOC VILL SANDIPUR PO DWARNARY DISTT PURBA MEDINIPUR KOLKATA 7134403 WB | KOLKATA | PURBA MEDINIPUR | WB | 7134403 | L4 | Rejected-AOC Higher rate quoted than L1 | |
| 5 | L5₹51.1 L+₹10.3 L (25.1%)Rejected-AOC | L5 | Rejected-AOC Higher rate quoted than L1 |
Tender Value
₹48.2 L
EMD Value
₹96,500
Closing Date
14 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2022_MES_553834_1
8400-864/E8
Open Tender
Civil Works
Works
210 days
PANAGARH
Class D and Category a (i) (Building)
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹96,500
Yes
7 Dec 2022
23 Sept 2022
15 Oct 2022
23 Sept 2022
14 Oct 2022
7 Oct 2022
Amount
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches, n.exc. 1.5m wide and n.exc. 1.5m in depth; for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
M&L for hardcore of broken stone or boulder of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc. 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for moorum/red bajri filling in floors or pavings, laid in layers n.exc. 15 cm thick, spread, levelled and rammed including watering and all as specified and directed.
M&L for cement concrete type D2 1:4:8 (using 40mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed
M&L for cement concrete type C2 1:3:6 (using 40mm graded stone aggregate) 75mm thick as in plinth protection finished even and smooth without using extra cement complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm in soft/loose soil complete all as specified and directed.
Removing excavated material (soil) n.exc. 50m and depositing where directed at a level n.exc. 1.5m above the starting point complete all as specified and directed
M&L for brick work with fly ash bricks old size, straight or curved on plan.exc 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for brick work with fly ash bricks old size, straight or curved on plan to any radius, in half brick walls built in cement mortar (1:4) complete all as specified and directed
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per item No 11.00 mentioned here-in-above but 6mm to 8mm dia complete all as specified and directed.
M&L for mild steel TMT bars 8mm dia and over as in stirrups , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4), finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall & applying Two coats of cement based paint over a coat of cement primer (exterior type) over new surfaces complete all as specified and directed
M&L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) on walls in cement mortar (1:6), complete all as specified and directed
M&L for rendering 5mm thick on fair faces of ceiling / chajja concrete surfaces in cement mortar (1:3) complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coat oil bound distemper over a coat of alkali resistant primer all as specified and directed. (Make: M/s Tractor Acrylic Distemper of Asian/M/s Bison Acrylic Distemper of Berger, M/s No 1 Premium Acrylic Distemper of Shalimar).
M&L for preparation of new plastered surfaces of wall and applying two coat oil bound distemper over a coat of alkali resistant primer over a layer of 1.5mm thick (minimum) wall care putty complete all as specified and directed. (Make: M/s Tractor Acrylic Distemper of Asian/M/s Bison Acrylic Distemper of Berger, M/s No 1 Premium Acrylic Distemper of Shalimar).
M&L for preparation of newly plastered ceiling surfaces and applying three coat of white wash complete all as specified and directed.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube as per specification and drawing complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet trip of 20mm with stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, S&F in the frame at site as per specification and drawing complete all as specified and directed.
S&F factory made steel ventilator with centre hung shutters, dovetailed or welded including pintol hinges, steel handles, etc. as shown with fixed type including one shop coat of red oxide zinc chrome primer complete all as specified.
S&F 100mm long Butt hinges, extruded aluminium alloy with galvanized mild steel hinge pin, anodized and fixed, type B-21 complete all as specified and directed
S&F aluminium anodized 150 mm barrel tower bolts of extruded section complete all as specified and directed
S&F 150 mm long aluminium alloy handles, fabricated type, anodized complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surfaces of size 350x250x7mm/450x350x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement with pigment to match the shade of tiles over and including 10mm thick rendering in cement mortar (1:4), on brick or concrete surface complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exc 0.06sqm but n.exc 0.11 sqm in floors laid over and including 15mm thick (1:6) cement mortar screed bed etc. set and jointed in neat cement slurry and pointed in white of coloured cement to match complete all as specified and directed.
M&L for cement concrete type B0 (1:2:4) (using 12.5 mm graded stone aggregate) 25 mm thick as in floor for receiving screed bed of floor tiling complete all as specified and directed.
Preparation of new or previously untreated steel surfaces and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed
S&F steel windows with side hung shutters (minimum wt. of steel section should be 1.42 kg/M) including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, including making good disturbed surfaces as per existing specification complete all as specified and directed. complete all as specified and directed.
S&F 3mm thick figured glass, pin headed type and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and directed.
S&F stop valves 15mm dia CP fancy type, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F PVC (SWR) 110mm dia pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed
M&L for PVC (SWR) floor trap 75mm dia, plain with grating including jointing with solvent cement etc complete all as specified and directed
S&F 15mm bore piller taps cast copper alloy, with capstan heads, chromium plated, screwed down, fancy type high pressure, with or without lettered 'HOT or COLD' with long screwed sunk and fly nuts complete all as specified and directed.
S&F vitreous china urinal, half stall type, white (excluding flushing cistern, flush pipe) including urinal spreader of PTMT any colour for fixing with 15mm dia pipe. (Minimum weight 60gms) and including waste pipe complete all as specified and directed
S&F CP bib taps 15mm dia, with fancy handle, screwed down, screwed for iron pipe or for brass ferrule, fancy type and fixed complete all as specified and directed.
S&F vitreous china Squatting pan ‘Orissa’ pattern, size 580 X 440mm, white, with integral foot rests and with ‘P’ or ‘S” trap, (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, etc and including provision of lime concrete bedding and make good the disturbed surface, complete all as specified and directed.
S&F in repairs wash down water closet (pedestal pattern) complete white with plastic water closet seat black closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device and flush pipe of polyethylene of low or density or PVC 32mm dia for low level flushing cistern complete all as specified and directed
S&F 10 litre capacity two way flush PVC low level flushing cistern with all accessories complete fixed with WC including syphone pipe, PVC flushing pipe of size complete all as specified and directed. (Make: Hindware/Parryware/Commander (Slim Line)
S&F tubular towel rail, 20mm dia, D type, brass chromium plated, 60cm long between flanges complete all as specified and directed
S&F PVC connection pipe 15mm size & 600mm long with chromium plated brass coupling on both ends suitable for 15mm bore steel tubing complete all as specified and directed
Construction of septic tank 25 user to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete all as per drawing complete all as specified and directed
Soakage wells 1.2 M dia X 3 M effective depth excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size complete all as specified and directed
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified.
Taking down cement plaster, any description on brick or stone walls and ceiling, chajja, landing etc including racking of joints hacking for key scrubbing down with water etc complete all as specified.
M&L for 15mm thick rendering in CM (1:4) mixed with water proofing compound on external surfaces of brick masonry wall finished even and fair complete all as specified and directed (Note: Water proofing item to be paid separately)
Supply only integral water proofing compound complete all as specified and as directed. (Make : Pidilite Industries/ Impermo/Snowcem India Ltd/Sika)
M&L for preparation of new plastered surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. (Make: M/s Apex Ultima of Asian/ Weather Coat all guard of Berger/Xtra Tough of Shalimar).
M&L for complete removal of existing surface and applying two coats of oil bound distemper on wall surface over a coat of alkali resistant complete all as specified and directed. (Make: M/s Tractor Acrylic Distemper of Asian/M/s Bison Acrylic Distemper of Berger, M/s No 1 Premium Acrylic Distemper of Shalimar).
M&L for preparation of old plaster surfaces after complete removal of existing treatment and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. (Make: M/s Apex Ultima of Asian/ Weather Coat all guard of Berger/Xtra Tough of Shalimar)
Dismantling (corrugated, semi corrugated) sheet in roof covering complete all as specified and directed
M&L for pre- painted galvatume aluminum zinc coating (@ 150 GSM) GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
S&F pre-painted galvalume aluminum zinc coating (@ 150 GSM) GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in Ridges fixed with self tapping screws as specified & directed.
M&L for flat iron fillets (for securing wire mesh, CGI Sheets etc.), Hand rails, half round or other steel section including embedding in concrete and screwing etc, wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed
Taking down chowkhats or frame n.exc 1.5 sqm each with shutter(s) (without taking off shutters from the frame), complete all as specified.
Taking down chowkhats or frame exc 1.5 sqm but n.exc 4 sqm each with shutter(s) (without taking off shutters from the frame), complete all as specified.
S&F 2nd class hard wood plain solid straight chowkhat and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joint complete all as specified and directed.
S&F factory made 35 mm thick 2nd H.W plain framed panelled shutters( two panel) with lock rail and panel of 9mm thick B.W.P commercial ply . The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated all as specified and directed.
S&F 35mm the 2nd class hard wood, glazed & skeleton shutters, open rebated & prepared to receive glass, (two panel to receive wire gauge) gauge etc, edges of framing plain, chamfered as rounded fitted with cut and mitered beads for securing etc complete all as specified and directed
M&L for preparation of newly wooden surfaces of any description not otherwise described over 10 cm girth or width and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
S&F sheet glass, 4,0 mm thick ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and directed
S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast-aluminium alloy complete all as specified and directed.
S&F mild steel flat iron as in hold fast clamps small articles conforming to Fe 290 GDE -E- 165 complete all as specified and directed.
M&L for PCC(1:3:6) type C1 (using 20 mm graded stone aggregate) as in bed blocks for hold fast including necessary formwork, kerb stones etc complete all as specified and directed
Floor door stopper of aluminium alloy body and tongue, anodized, with hard drawn steel spring, fixed in floor 150mm long complete all as specified and directed
Dismantling floor hearth or wall tilling including cement mortar bedding, removing rubbish off the premises for minor repairs to floor in patches all as specified and directed.
M&L for 75mm thick cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed
M&L for 40mm thick PCC 1:2:4 type B-1 (using 20mm graded coarse aggregate) in flooring complete all as specified and directed.
M&L for non-skid ceramic tiles 7 to 8 mm thick area of each tile exc 0.18 sqm but n.exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including cement screed bed 15mm thick in CM (1:6), including including dismantling wall tiling and cement mortar bedding complete all as specified and directed.
M&L for non-skid ceramic tiles 7 to 8 mm thick area of each tile exc 0.18 sqm but n.exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including cement screed bed 10mm thick in CM (1:3), including including dismantling wall tiling and cement mortar bedding complete all as specified and directed.
M&L for PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in surface channels and drains complete all as specified and directed
M&L for coloured non skid joint free ceramic tiles 7 to 8 mm thick (Square/Rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors etc set and jointed in neat cement slurry over and including 15 mm thick screed bed or bedding layer in cement mortar (1:4) complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position in framed worked complete all as specified and directed.
M&L for Second class hard wood in scantlings clean sawn timber framed and fixed work in any poistion complete all as specified and directed.
Dismantling wrought Iron or mild steel work of any description not otherwise provided for wind tie complete all as specified and directed.
S&F roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. Fe-410-W (Gde-E-250) quality-A complete all as specified and directed
M&L for applying one coat of synthetic enamel paint on old steel surfaces of any description over 10cm in width or girth not otherwise described incl preparation of surfaces complete all as specified and directed
Taking up or down steel tubing and connection including cleaning for refixing or removed to store, 15 mm dia bore complete all as specified and directed.
S&F GI tubing 15mm bore medium grade with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
S&F vitreous china wash basin, white , flat back , size 550 x400mm (for hospital use) excluding taps, waste, chain and plug and porcelain stopper but including brackets any size, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe
S&F vitreous China urinals, bowl type (back or corner wall type), of size 465 x 355 x 265mm white complete including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2) securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and directed. (Note: Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)
S&F 15 mm bore stop valve cast copper alloy screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F PVC connection 15mm size PTMT nuts of length 600mm complete all as specified and directed.
S&F grating square 150mm size of PTMT (minimum weight 100 gms) complete all as specified and directed.
Supply flush pipe of polyethylene of low or high density of PVC, 32 mm dia, for low level cistern complete all as specified and directed.
S&F as in repair 75mm dia PVC pipe fixed to wall or laid in trenches set in cement mortar with and including MS clamps made out of flat iron of size 25mm x 3mm including nuts bolts etc complete all as specified and directed.
S&F PVC bends plain (any radius) for 75mm bore PVC pipes complete all as specified and directed.
M&L for 50mm thick PCC 1:2:4 type B-1 (using 20m graded crushed stone aggregate) as in roof padding, finished fair and even without using extra cement, including demolition of cement concrete (un-reinforced) roof surfaces complete all as specified and directed.
M&L for rendering 10 mm thick with WPC on fair faces on roof surfaces of concrete surfaces in cement mortar (1:4) complete all as specified and directed.
M&L for preparation new surfaces or roof and apply two coats of polyurethane (PU) acrylic based water proofing liquid compound over & including one coat of self priming @ one litre per ten sqm with reinforcing fabric sheet as per manufactures instruction to stop leakage/ seepage from roof/ wall complete all as specified and directed by the Engineer-in-charge. (Note:- (i) As per description of these item minimum two coats of Polyurethane (PU) acrylic based water proofing liquid compound over one coat of primer shall be carried out by as per manufacturer instruction. Please note no price adjustment shall be made, if as per manufacturer instructions more coats of polyurethane )PU) acrylic based water proofing liquid compound & primer are required for roof treatment. ii) Quoted rate shall be deemed to be included for work in building/ structure of any height).
M&L for reinforced cement concrete M-25 (Design mix) (using 20mm graded stone aggregate) foundations, including rafts, footings, foundation beams, plinth beams; bases for columns, etc. and mass concrete etc complete all directed.
M&L for reinforced cement concrete M-25 (Design mix) (using 20mm graded stone aggregate) as in Columns, pillars, piers, etc complete all as specified and directed.
M&L for reinforced cement concrete M-25 (Design mix) (using 20mm graded stone aggregate) in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed
All as per item No 96.00 mentioned here-in-above but in chajja complete all as specified and directed.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter complete all as specified and directed
M&L for formwork to sides and soffits of floor or roof beam, beam hauchings, girders, bressum-mers, lintels cantilever, shelves including supports, overhangs, etc also splays between floors and beams etc complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed
All as per item No 100.00 mentioned here-in-above but in chajjas complete all as specified and directed.
All as per item No 100.00 mentioned here-in-above but for sides and soffits and soffits of beams and lintels complete all as specified and directed
All as per item No 100.00 mentioned here-in-above but for side of slab exc 10cm but n.exc 20cm thick complete all as specified and directed
M&L for 100mm thick plain cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregates) as in sub base of floors including finishing the surfaces even and rough to receive the topping layer complete all as specified and directed.
Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge
Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge
S&F 4mm thick Non asbestos fibre cement building boards designer type fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed
S&F anodised aluminium snap grid frame work for false ceiling all as specified with Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long complete all as specified
M&L for PCC 1:3:6, D2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete all as specified and directed
M&L for brickwork with fly ash bricks, straight or curved on plan.exc 6m mean radius, built in CM (1:4) with old size bricks complete all as specified and directed
Extra for forming fair finished drain or channel upto 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and directed.
M&L for PCC 1:2:4 type B1 as in lintels / beam up to 1.5m clear span, and other similar bands, copings, kneelers, apex stones, bed plates, kerbs and haunching/ benching, water troughs and the like including weathering, slightly rounded or chamfered ang complete all as specified and directed
Excavating over areas, n.exc 1.5 m deep and getting out in soft and loose soil complete all as specified and directed.
M&L for 200 mm thick laid in two layers of each 100mm thick in pavings, with mix of fly ash, clinker & stone dust in the proportion of 1:3:6 (ie 10% fly ash, 30% clinker and 60% stone dust ) laying in layers n.exc 30cm thick, watering, ramming and compacted with hand/power roller 8 to 12 ton roller to required camber and gradient complete all as .directed by Engineer-in-Charge.
M&L 100 mm thick PCC 1:2:4 type B2 (using 40mm graded crushed stone aggregate) as in hard standing laid in panels with and including use and waste of formwork and to divide the area in panels and finishing the surface even and smooth without using extra cement complete all as specified and directed
Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ when thickness of concrete slab is 100mm complete all as specified and directed.
Cement Concrete, 1:2:4, type B1 (using 20mm graded stone aggregate) as in bed block, coping, lintel up to 1.50 m span, cills, kerbs etc complete all as specified and directed
M&L for Reinforced Cement Concrete (Design Mix) M-25 in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; n.exc 200mm thick (Horizontal or sloping) complete all as specified and directed.
M&L for preparation of new surfaces of wall and applying three coats of white wash complete all as specified and directed.
S&F capacity 2000 Ltrs rotational moulded polyethylene water storage tanks (Cylindrical, vertical with closed top) confirming to relevant IS complete including provision of all inlet outlet overflow and drain pipe fitting complete all as specified and directed by Engineer in Charge. (Make: Sintex/Vectus/Prayag)
S&F of high pressure PTMT float valve with epoxy coated alluminium rod and high density polyethylene ball screwed for iron pipe 25 mm dia with fly nut complete all as specified and directed
M&L for 25 mm bore gate valve cast copper alloy screwed down high pressure with clutch handle screwed both ends for Iron pipe complete all as specified and directed
S&F 25 mm bore GI Tubing medium grade in Trenches/ Floor/Pillar and connection including fitting like socket /Union/Tee/Reducer Nipple etc complete all as per specified and directed.
S&F 50 mm bore GI Tubing medium grade in Trenches/ Floor/Pillar and connection including fitting like socket /Union/Tee/Reducer Nipple etc complete all as per specified and directed.
EM PORTIONS M&L for point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectional area multistranded copper conductor FRLS PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
All as per item No 126.00 mentioned here-in-above but One 3 pin 5 Amps socket out let points on independent board complete all as specified and directed
All as per item No 126.00 mentioned here-in-above but 5 Amp socket on same board with other switches complete all as specified and directed.
M&L for wiring for socket out let on independent Boards controlled by one, one way switch using 4.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 4.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
S&F switch piano flush type, single pole , 5/6 Amps, one way complete all as specified and directed.
S&F switch socket combination 2 in 1 multipurpose 5 pin, (6 Amps) flush type controlled by one switch complete all as specified and directed.
S&F socket outlets 2 in 1, 3 pin, 5/6 Amps flush type 230/240 V complete all as specified and as directed. (For Same Board only)
S&F switch socket combination 5 in 1 , 6 pin , (5/16 Amps ) flush type controlled by one switch complete all as specified.
S&F ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified.
S&F building security light fittings 25 watts, minimumm system lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbonate diffuser and individual LED with secondary optic and IP65 including necessary connection complete suitable for pole dia 25mm complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as directed.
S&F 18 W LED light fitting wall mounted batten 4'ft, extruded polycarbonate, environmental friendly, heat sink provided for efficient heat dissipation and integrated electronic driver for 18 watt,6000K including necessary connection complete all as specified and directed.
S&F epoxy powder coated sheet metal enclosure for DBs, double door, Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel, neutral link and incoming contact complete all as directed.
S&F MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs including necessary connection complete all as specified and directed. (Note : Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating)
S&F MCB SPN 6-32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessary connection all as specified and directed. (Note : Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating)
M&L for earthling complete with galvanized mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth wire electrode bolted or riveted to earth plate at one end and connected to equipments at another end, GI earth wire encased in and including 15 mm dia GI 'light grade' pipe from upper end of earth plate up to equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. (Note :- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) Testing to be carried out by the contractor in presence of Engr- in- Charge, entered in the earth testing register, prepared and to be maintained by the contractor & submitted to Concerned JE E/M. (iii) T&P and testing instrument(Meger) to be provided by the contractor at own cost).
S&F ventilating exhaust fan 300 mm sweep 230 volt AC complete with louver and all accessories including cutting hole of suitable size, making good surface by doing plaster and applying two coat of distemper complete with fixing arrangement to wall connected with twin core twisted flexible copper conductor (23/.0076) of suitable size all as directed.
Taking down carefully aluminium conductor point wiring (light,fan,socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators ,sockets etc. and removing (except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified.
S&F stepped type electronic fan regulator flush type 240 Volts ISI marked complete all as specified .
S&F two single core ,6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade drawing in and including and including suitable size PVC conduit (ISI marked), concealed, including 6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified. (Note: (i) Three runs cable and conduit pipe will be measured as single unit. (ii) Quoted rate deemed to be included for necessary chasing/cutting and making the good surface)
S&F recessed mounted 2' x 2 ' LED luminaire 36 watts for grid ceiling minimumm lumen output 100 lumen/Watt, pre-treated CRCA frame powder coated with diffused Profied including necessary connection complete all as specified and directed.
S&F vertical distribution board double door TPN 4 way with IP 43 multiphase outgoing suitable for mounting 100 Amps as incomer with Bus bars, Neutral links complete with all accessories complete all as directed.
S&F MCCB of 4 pole , 415 volts of capacity 100 Amps with breaking capacity of 16 KA Fixed thermal and fixed magnetic setting including necessary connection complete all as specified and directed.
Taking down of AC ceiling fan of any sweep & any height and opening the fan and oiling, greasing and replacement of unserviceable accessories and servicing, complete overhauling and re-assembling and testing complete for efficient functioning and hanging it back in position including provn of 0.5 Sqmm copper flexible twin twisted cable (length n.exc 0.5 metre) from ceiling rose to fan as directed by the Engr-in-Charge. (Note : Accessories such as gun metal bush and split pin and jam nut shall be measured and paid under relevant here-in-after).
M&L for painting of ceiling fans upto 1400mm sweep carefully, dismantling fan blades and paint with one coat of synthetic enamel paint including filling cavities with filler after cleaning all dust etc complete all as directed.
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed
Supply, laying / fixing / connecting, testing and commissioning of 10 Sqmm x 2.0 core LT under ground cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the cross sectional area including cable glands, lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) all as directed by the Engr-in-Charge. (Note: Excavation, sand cushioning, brick will be measured and paid separately).
M&L for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . (Note : Punned thickness 18 cm shall only be considered for payment)
Supply and lay in trenches fly ash bricks, for cable protection all as specified and directed by the Engr-in-Charge.
S&F pipes galvanized, 50 mm bore “light grade”, supplied and laid complete including necessary fittings such as tees, bends, elbows, sockets, reducers etc as per site requirement or specified.
Hooghly Construction Co.
subash chander bahl
UNIVERSAL TRADING
M/S Konar Engineering
M/S FM Enterprise
NATIONAL CONSTRUCTION CO
M/s Santosh Industrial Corporation
KAKOLI ENTERPRISE
SINGH CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .