| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.9 L+₹1.2 L (5.09%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹26.0 L+₹2.3 L (9.69%)Rejected-Finance 801802 SAKAR IV OPP MJ LIBERARY ELLISBRIDGE ASHRAM ROAD AHMEDABAD AHMEDABAD GUJARAT 380006 | 801802 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹29.2 L+₹5.5 L (23.3%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | Rejected-Technical NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | - | Rejected-Technical Not Being Eligible |
Tender Value
₹29.5 L
EMD Value
₹59,000
Closing Date
18 May 2020, 6:00 pmClosed
CWE AF SOUTH BANGALORE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
PROVISION OF SMOKE DETECTOR AND FIRE ALARM SYSTEMTO CPSS BUILDING AT 2 AFSB MYSORE UNDER AGE (I) (AF) CHIMNEY HILLS
2020_MES_339705_1
82072
Open Tender
Civil Works
Item Rate
150 days
Chimney Hills
As per tender documents
7 documents required · 7 mandatory
₹500
AGE (I) (AF) Chimney Hills
₹59,000
Yes
1 Sept 2020
20 Apr 2020
21 May 2020
20 Apr 2020
18 May 2020
6 May 2020
21 Apr 2020 - 28 Apr 2020
Amount
Supply, install, test and commissioning of microprocessor based intelligent addressable fire alarm control panel of 1 Loop, connects 240 addressable devices (including detectors, manual call points, sounders and modules), network communication card, 1/4 VGA graphic/LCD display with keypad and minimum 10000 events log in the volatile memory (EPROM). The panel shall have power supply unit (230V AC ±5%, 50 Hz) with automatic charger and 24V sealed maintenance free batteries for 24 hours back-up in normal condition and 30 minutes back-up in alarm condition. The panel shall have facility to connect printer to printout event logs, and shall be complete with all accessories. The panel shall be approved to EN 54-2, EN 54-4, VdS/LPCB all as specified. Make : CEASE FIRE / Honeywell
Supply, install, test and commissioning of Translator module, shall allow addressable loop communication to 32 wireless field devices, system devices can be configured through translator module or software, two orthogonal antennas for safe and reliable wireless communication, shall have high wireless transmission range of max. 200 meter in open space, with 7 bi-directional data channels for wireless communication, operating frequency range 865MHz to 867MHz. Approved to EN 54-18 and EN 54-25 by LPCB/VdS all as specified. Make : CEASE FIRE / Honeywell
Supply, install, test and commissioning of Expander module to enhance the wireless communication range of translator module, shall allow wireless communication to 32 wireless field devices, system shall be configured through software, two orthogonal antennas for safe and reliable wireless communication, shall have high wireless transmission range of max. 200 meter in open space, with 7 bi-directional data channels for wireless communication, operating frequency range 865MHz to 867MHz. Approved to EN 54-18 and EN 54-25 by LPCB/VdS complete including IP 67 grade back box with cable glands for mounting expander module all as specified and as directed. Make : CEASE FIRE or Eqvt in Honeywell
Supply and install power supply unit 24VDC-3A suitable for Expanders at Item Sl No 3 above all as specified
Supply, install, test and commissioning of wireless photoelectric (optical) smoke detectors with smoke sensing chamber having sensitivity range of 2.0 %/m to 3.0%/m, 7 bi-directional data channels for wireless communication, operating wireless frequency between 865MHz to 867MHz, operating communication range of max. 200 meter in open space, support magnet test or gas based tester, dual trap/filter to prevent entry if insects and dust particles, provided with dual lithium batteries (primary and secondary power source). Approved to EN 54-7 and EN 54-25 by LPCB/VdS complete including suitable back box for mounting detectors all as specified and as directed. Make : CEASE FIRE / Honeywell
Supply, install, test and commissioning of wireless heat detectors above false ceiling with alarm temperature of 58oC, 7 bi-directional data channels for wirelesss communication, operating wireless frequency between 865MHz to 867MHz, operating communication range of max. 200 meter in open space, support magnet test or gas based tester, dual trap/filter to prevent entry if insects and dust particles, provided with dual lithium batteries (primary and secondary power source). Approved to EN 54- 5, EN 54-25 by LPCB/VdS complete including suitable back box for mounting detectors all as specified and as directed. Make : CEASE FIRE or Eqvt in Honeywell
Supply, install, test and commissioning of wireless manual call point resettable type, 7 bi-directional data channels for wireless communication, operating wireless frequency between 865MHz to 867MHz, operating communication range of max. 200 meter in open space, provided with dual lithium batteries (primary and secondary power source). Approved to EN 54-7 and EN 54-25 by LPCB/VdS all as specified. Make : CEASE FIRE or Eqvt in Honeywell
Supply and errecting GI pole four metre long with necessary fixing accessories as required for mounting expanders including necessary PCC foundation complete all as directed.
Supply only portable fire extinguisher ABC podwer MAP 90 based 5 Kg all as specified. Make : Cease fire or equivalent
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,2 core, 1100 Volts grade
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in hard/dense soil for laying/repair of cable.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm thick.
Removing excavated materials to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
Supply and lay brunt bricks class 'B' of standard size in trenches for protection of UG cable.
Supply and lay GI tubing light grade, 25mm dia in trenches for road crossing/laid in floors etc
Labour for riddled earth done through by riddle of excavated soil and spread the same as 23 cm layer on below and upper part of the cable as cable cushioning to UG cable all as per clause 19.75 of SSR part -I
M&L in replacement for earthing with galvanised iron earth plate electrode 600mm x600mmx 6mm thick burried directly in ground (Earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of earth plate not less than 1.5 metres below normal ground level, connected to galvanised iron wire of 4 mm dia connected to earth plate electrode by means of bolts,nuts,check nuts and washers,earth wire protected with and including 15 mm bore medium grade GI pipe all as shown in electrical plate no 3 of MES schedule part-1, with and including PCC 1:3:6 type C1 pit with cover of RCC 1:2:4 type B1, reinforced with welded steel wire fabric not less than 4 kg per sqmtr with handle and angle iron frame, watering arrangement with 20 mm bore GI medium grade pipe, GI funnel with wiremesh, filling with mixture of common salt and charcoal, necessary excavation, refilling, removing away soil and earth work in any type of soil, testing and commissioning complete.
SREE VARU ELECTRICALS
CIMCON SOFTWARE INDIA PVT. LTD.
RNR CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .