| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.0 LAccepted-Finance A 14 USHA SADAN NEAR POST OFFICE COLABA MUMBAI 05 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L1 | Accepted-Finance Lowest One | |
| 2 | L2₹74.7 L+₹16.7 L (28.9%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹75.3 L+₹17.4 L (30.0%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹79.5 L+₹21.5 L (37.1%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹99.4 L+₹41.5 L (71.6%)Rejected-Finance BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
5 Jun 2023, 6:00 pmClosed
GE NW NOFRA
Dr Homi Bhabha Road New Navy Nagar Colaba Mumbai
REPAIR REPLACEMENT AND MAINT OF E/M FITTING FIXTURES INCLUDING DBs MAIN SWITCHES AND REPAIR REPLACEMENT OF OLD DETERIORATED STREET LIGHT POLES AND LED STREET LIGHTS AT OUTLAYING AREAS UNDER GE NW NOFRA
2023_MES_594474_1
8174
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
Mumbai
Please refer tender documents
8 documents required · 8 mandatory
₹1,000
GE NW NOFRA
₹1.7 L
Yes
13 Jun 2023
10 May 2023
7 Jun 2023
10 May 2023
5 Jun 2023
22 May 2023
10 May 2023 - 17 May 2023
Amount
Taking down carefully aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc to be measured separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified.
Material and Labour for point wiring complete with 1.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC Casing caping of size not less than 20 / 25 mm size including PVC bend, tee joints etc as per site requirement , ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes/ modular boxes surfacing on wall including one FRLS PVC insulated & sheathed multistranded green colour copper conductor 1.5 sqmm as earth continuity conductor connected to common earth as earth dolly for :- Make of cable ; Polycab, Finolex, Havells. Make of casing & capping : Precision, Supreme, Pressfit
(a) One light point controlled by one switch SP one way.
(b) One ceiling fan point controlled with one 5A switch
(c) One exhaust fan point controlled with one 5A switch
(d) One bell point controlled by one bell push 5 Amps.
(e) One 3 pin socket outlet 5Amps on independant board.
(f) One 3 pin socket outlet 5Amps on same board with other switches.
(g) One 3 pin socket outlet 15 Amps on same board with other switches.
Material and Labour point wiring for Geyser /AC complete with 4 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC casing caping of size not less than 20 / 25 mm size including PVC bend, tee joints etc as per site requirement, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes / modular boxes surfacing on wall including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 4 sqmm as earth continuity conductor connected to common earth as earth dolly. Make of cable ; Polycab, Finolex, Havells. Make of casing & capping : Precision, Supreme, Pressfit
- do - as per ser No 2 but for point wiring for 15 Amps socket complete with 2.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors .
Supply and fix Modular Switch, 6Amp, One way, 1 module. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (NIXON).
S&F Modular type bell push , 6Amp, 1 module, ISI marked. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (NIXON).
S&F Bell electric AC 230Volt single pole musical type, ISI marked. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (NIXON).
Supply and fix support function blank plate single, 1 module complete all as specified and directed.
Supply and fix Modular type, electronic fan regulator (5 step), 450 Watts, 230 volts, 2 module complete all as specified and directed . Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (NIXON).
Supply and fix ceiling rose surface bakelite with ISI mark, flush type with ISI mark three terminals complete all as specified.
Supply and fix Modular Socket oulet, 6 Amps, 2/3 pin combined, 2 module. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (NIXON).
Supply and fix Modular Socket oulet, 6/16 Amps, 2/3 pin combined, 2 module complete all as specified and directed Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (NIXON).
Supply and fix Modular white cover plate with Frame 2 Module complete all as specified and directed. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (WEGA)
- do - as per ser No 13 but modular white cover plate 3 module
- do - as per ser No 13 but modular white cover plate 4 module
- do - as per ser No 13 but modular white cover plate 6 module
- do - as per ser No 13 but modular white cover plate 8 module
- do - as per ser No 13 but modular white cover plate 12 module
Supply and fix Modular metal flush box 2 module including cutting, chassing, filling putti & good make of distrubed surface and matching with existing colour complete all as specified and directed. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (WEGA)
- do - as per ser No 19 but metal flux box 3 module
- do - as per ser No 19 but metal flux box 4 module
- do - as per ser No 19 but metal flux box 6 module
- do - as per ser No 19 but metal flux box 8 module
- do - as per ser No 19 but metal flux box 12 module
Supply and fix Polymer extruded channel, with opaque diffuser for glare free light 1x20 WH 04 feet long accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size with all accessories complete all as specified and directed . Make : Havells/Philips/Jaquar/wipro
Supply and fix Polymer extruded channel, with opaque diffuser for glare free light 1x18 WH 04 feet long accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size with all accessories complete all as specified and directed . Make : Havells/Philips/Jaquar/wipro
Supply and fix Polymer extruded channel, with opaque diffuser for glare free light 1x10 WH 02 feet long accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size with all accessories complete all as specified and directed . Make : Havells/Philips/Jaquar/wipro
Supply and fix Plug and Socket enclosure, in sheet metal enclosure with MCB, SP 20 Amps 240 Volts complete with metal clad socket for window type air conditioners.Make: Havells / Legrand / Scheinder / GEas approved by GE.
Taking down old unserviceable submain cable of any size and capacity and finishing wall surfaces.
Supply and fix submain wiring in repair with two single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm in and including PVC casing and caping of suitable dia, ISI marked including 1 single core cable with stranded copper conductor of size 4 sqmm (green colour) for earthing. Make : Polycab, Havells, Plaza, Finolex Make of casing & capping : Precision, Supreme, Pressfit Note :- (i) Two runs of 4Sqmm cable, 1 run of PVC casing & caping and 1 run of 4 Sqmm cable shall be measured as 1 RM. (ii) Each submain wiring shall run in seperate PVC casing caping
As item No 30 but 6 Sqmm sub main
As item No 30 but 10 Sqmm sub main
Supply and laying / fixing in flexible copper conductor PVC insulated and sheathed cable 1100 volt of size 2 core 6.0 Sqmm laid in trenches / through PVC pipe/batton from meter panel board to building cable trunch or fixed on wall in vertical position with sadling and sadling distance each other 01 mtr complete all as specified and directed by Engineer-in-charge. Note : Amount of PVC pipe /cassing caping included in quoted rate, no extra Amt paid by the deptt.
Taking down unserviceable XLPE cable and Supply and fixing cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 10 sq mm 2 core. laid in trenches / through PVC pipe/batton from meter panel board to building cable trunch or fixed on wall in vertical position with sadling and sadling distance each other 01 mtr complete all as specified and directed by Engineer-in-charge. Make : Polycab / Finolex/ Havells Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it. 2. cable laying through HDPE pipe 32 mm dia meter panel to duct
Supply and fix sheet metal enclosure 12 way Double door type having protection IP-42, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed of comprising of the following :- Make: ABB, Strandred/ Legrand
Supply and fix sheet metal enclosure 8 way Double door type having protection IP-42, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed of comprising of the following :- Make: ABB, Strandred/ Legrand
MCB SPN (DP) 63 Amps, 240 Volts, 10 KA Make - Legrand Equivalent in siemens/Standard/ Havells
MCB SP 32 - 40 Amps, 240 Volts, 10 KA Make - Legrand Equivalent in siemens/Standard/ Havells
Supply and fixing MCB TPN (four pole) 100 Amps, 240 Volts, 10 KA Make - Legrand Equivalent in siemens/Standard/ Havells
Material and labour for cleaning all ldust filling cavities with filler, prepartation of surfaces, painting of ceiling fans , in situ with one coat of synthetic enamel paint by spray painting complete all as specified and directed . Make : Asian Apoclite, Berger, Nerolac Hi Gloss
Material and labour for cleaning all ldust filling cavities with filler, prepartation of surfaces, painting of Exhaust fan , in situ with one coat of synthetic enamel paint by spray painting complete all as specified ;and directed . Make : Asian Apoclite, Berger, Nerolac Hi Gloss
M & L for rewinding of unserviceable ceiling fans lof size 1200/1400 sweep with approved copper enamalled wire of suitable guage, varnishing, replacing existing split/ quarter pins, rubber bush, capacitor 2.5 Mfd and including taking down and refixing in exsiting position and testing complete all as specified and directed by Engr in charge.
M & L for rewinding of unserviceable exhaust fans lof size 225/300/450/630mm sweep with approved copper enamalled wire of suitable guage, varnishing, replacing existing nut bolts pins, rubber bush, capacitor , bearing ,m bush, frastner etc and including taking down and refixing in exsiting position and testing complete all as specified and directed by Engr in charge.
S&F in repair Switch 5 Amps piano type, single pole 230 Volts complete all as specified and directed
S&F in repair switch socket combination multipurpose for 3/2 pin 5 Amps flush type ISI marked complete all as specified and directed.
S&F in repair switch socket combination multipurpose 2 in 1 for 3 pin 15 Amps & 3pin 5 Amp controlled by one switch flush type complete all as specified and directed.
S&F in repair stepped type electronic fan regulator flush type 450 Watts, complete ISI marked all as specified and directed
S&F in repair bell push flush type 5 Amp complete ISI marked all as specified and directed.
Supply and fixing in repair Capacitor 2.5Mfd complete all as specified and directed.
Supply and fix in repair PVC Box for Switches, with fixing accessories complete of the following sizes :-
(a) -do- but size 4”x4”
(b)-do- but size 4” x 7”
(c)-do- but size 6” x 8”
(d)-do- but size 10” x 8”
Supply and fix in repair LED lamp suitable for 14 watts, 240 volts, single phase, 50 Hz, Lumen 1450 AC supply complete all as specified and directed. Make :Jaquar / Philips/ Havells.
Material and Labour in repair for Lamp holder, PVC /Polycarbonate type with cord grip cap suitable for pendant fittings complete all as directed by Engineer-in-Charge.
Supply and fixing GI strip 32/6 for building earthing and sadling in high rise bldg wall (G+ 15 floor), cable trunch, building cable duct from the LT panel to DB up to height of 50 RM from ground and fix properly all as directed by Engr-in-Charge
Taking down unserviceable light and Supply and fixing Ceiling light 36 WATT 2 ft X 2 ft Recess mounting led ultra slimceiling light with extruded aluminium housing and milky diffuser.LED ultra slim panel:CYGNUS SERIES.make- Havells/ C&S /Phillips
M&L for stopping the leakage of the geyser of any capaciry by applying brazing to inner tank and refixing the inner tank after making it functional all as specified and as directed by engr-in-charge. Note : Adeuqate water pressure will be apply to the brazed tank to ensure that no leakage is left if the tank leaked the same will be repaired by the contractor witout claiming any additional cost from the department.
S&F in replacement of heating element as required at site of 1.5 KW ISI marked as required at site and approved by Engr-in charge. Make: CG,Havells,Racold as approved by GE.
S&F in replacement of heating element as required at site of 2.0 /03 KW ISI marked as required at site and approved by Engr-in charge. Make: CG,Havells,Racold as approved by GE.
S&F in replacement thermostate switch for geyser of any type ISI marked complete all as specified and directed by engineer in charge.
S&F in replacement thermmal cut out for geyser of any type ISI marked complete all as specified and directed by engineer in charge.
S& F in replacement geyser steel inner tank assembly suitable for geyser capacity of 06 Ltr complete all as specified and directed by engineer in charge.
S& F in replacement geyser steel inner tank assembly suitable for geyser capacity of 25 Ltr complete all as specified and directed by engineer in charge.
S&F in replacement steel inner tank for geyser of 03 Ltr capacity complete all as specified and directed by engineer in charge.
S&F CP in replacement non return valve 15mm bore with air lock relase arrangement ISI marked complete all as specified and directed by engineer in charge.
S&F in replacement of glass wool for geyser of 6/25 ltr complete all as specified and directed by engineer in charge.
S&F in replacement of inspection cover stainless steel in 2 piece suitable for gesyer of 50/25 / 6 ltr capacity and having provision of fixing indiactor lamps complete all as specified and directed by engineer in charge.
S & F in repairs PVC insulated 3 core circular stranded copper conductor of 2.5 sqmm complete all as specified and directed by engineer in charge. Make: Havells,Finolex,Polycab as approved by GE.
S&F CP gate valve of 15 mm bore suitable for fixing on existing fittings complete all as specified and directed by engineer in charge. Make: Leader , Zoloto , Sant as approved by GE.
Supply and fix hot water extension pipe made out of copper chromium plated 450 mm long with brass adaptor and fixing in position complete all as specified.
Supply and fix Cold water extension pipe made out of copper chromium plated 450 mm long with brass adaptor and fixing in position complete all as specified.
Supply and fixing 15 mm Bib taps, cast copper alloy with crutch or round handle, screwed down, screwed for iron pipe or for brass ferrule and fixed
S&F in repairs hote water PVC pipe 15 mm bore with all fittings as required at site i.e. elbow,socket,nipple reducer & union as required for plumbing work and making connection as required at site all as specified and as directed by engr-in-charge. Note: Rate quoted shall also include the plumber work as per site requirements.
S&F in repairs of top plug 15 Amp 3 pin complete all as specified and directed by engineer in charge. Make: Anchor,Plaza,CG as approved by GE.
S&F in repairs indicating lamp green/red in colour 230 volts complete all as specified and directed by engineer in charge.
S&F of NRV as per existing sample of instant geyser 03 ltr / 06 ltrs complete all as specified and directed by engineer in charge.
Supply & Fixing 3 inch / 4 inch long 12 mm to 20 mm dia fastner including bolt , pin , washer complete all as specified and directed by engineer in charge.
Checking serviceability of all geyser in each quarter and checking fastner nut, bolts, pins indicator lamps , NRV, thermostate , thermal cut out etc are in healthy condition If any problem in any items will be note down by electrician and informed concerned JE E/M and rectify the problem next day complete all as specified and directed by engineer in charge. Note : All the items will be paid separately
Supply and fix electric water heater,instent type steel body with copper inner tank testing and commissioning of water heater (geyser) vertical type of 03 Ltrs capacity , single phase, vertical type, Rust Resistant, ABS made with thermal cut off with power consumption 1500 watts, ISI marked, BEE 5 star rating including fixing on wall with chroumium plated screws & nut bolts connected to existing water and electric connection complete all as specifed and directed by Engr-in-Charge. Make- Racold Pronto Neo / Havells/ Jaquar
Excavation in trenches not exceeding 1.5 Mtrs. wide and not exceeding 1.5 Mtrs. in depth for foundation, laying of cablesetc and getting out in hard/dense soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated material (Soil) n.exc 50 m and depositing where directed at a level n. exc 1.5 Mtrs. above the starting point complete all as specified and directed by Engineer-in-Charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc. 25cm depth in soil complete all as specified and directed by Engineer-in-Charge.
Cutting and removing grass, vegetation bushes etc and brooming in side/outside of water supply electric supply installation and removing all rubbish to a distance not exceeding 50 m as directed and cleaning/ brooming in water /electric supply station complete all as specified and directed by Engineer-in-Charge.
Trimming tree branches on the route of LT line nearer to LT/HT line , pump house , pipe , roof, street light fitting & poles complete all as specified and directed by Engineer-in-Charge.
Dismantling steel poles/struts, any size from existing detorated street pole complete all as specified and directed by Engineer-in-Charge.
Taking down and Checking and repairs to street light fitting from Truss ,Highbay light, flood light , Perimeter light , Post Top Lanterns , Obstruction light, Avaition light fittings inside / out side of NT POOL, SASSON COMPLEX , BOOT POOL, TALWAR CAMP, REIVERA & HARBOUR HEIGHTS, DUXBURY, ADITI AHILYA, VISHAKHA , VANDNA AND FOMA HOUSE , fitting any height street light pole (9/11) mtrs, hanger, truss, wall repair and checking and cleaning internal complete wiring, bulb, ignator, holder, rectifying the defects and removing of burnt cable if any including repair/replacing the unserviceable items as mentioned in below items (wherever necessary) and testing the same on ground at site for its serviceability and refixing the same at original place/location complete all as specified and directed by Engineer-in-Charge. Note :- (a) If the contractor have not given job card to his tradesman in any working day and have not attended any complaint , the necessory recovery of Rs. 500/- per day shall be imposed by Engineer-in-charge . (b) Routine check shall be done for all types of non opps street / secutity light fitting in each and every location in routine wise manner every day by tradesman. (c) Driver and cable shall be measured paid and separately
S&F cable junction boxes IP 66/67 weather proof for out door installation with knock outs cable entry junction box size should be 205x255x112 with terminals including complete all accessories, all as specified and directed by Engineer-in-Charge. Make - Sintex , Finolex , Universal , National as approved by GE
Taking down old unserviceable junction box . S&F of new cable junction boxes IP 66/67 weather proof for outdoor installation (with knock outs cable entry junction box size should be 300x100x450 mm aluminium bus bar 4 strip mounted on protection insulator with two Nos and front openable hinged and locking arrangements including complete all accessories , all as specified and directed by Engineer-in-Charge. Make - Sintex , Finolex , Universal , National as approved by GE
Taking down old unserviceable garden light. Supply and fixing of LED garden light 10 W cylindrical shaped integral decorative LED bollard with Opal acrylic diffuser and IP 65 With all acessories including PCC foundation tapper plug bolts,nuts,screwed and GI pipe 76 mm dia etc complete all as specified and directed by Engineer-in-Charge. Make - Havells /Philips / Jaquar
Taking down old unserviceable garden light. S&F for post top 35 watt energy saving environmental friendly long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminiare with high power LEDs as light source complete all as specified and directed by Engineer-in-Charge. Make : Philips / Havells / Jaquar
Taking down old unserviceable light. S&F new 45 watt LED new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting Source and LENs embedded toughned glass cover with IP66 Protection and impact resistance of IK07 complete all as specified and directed by Engineer-in-Charge. Make : Havells /Philips / Jaquar
Taking down old unserviceable fitting. S&F of New LED Bldg security light 70 Watt indus series powder coated pressure die cast aluminium high power LED bldg security light with heat resistant toughned glass with lens with IP66 Protection , complete all as specified and directed by Engineer-in-Charge. Make : Havells /Philips / Jaquar
Taking down old unserviceable fitting. S&F of 120 WATT LED street light made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 complete all as specified and directed by Engineer-in-Charge. Make- Havells /Philips / Jaquar
Supply and fixing Street light timer, Astronomical time operation, sunrise sunset based operations, Current Rating (In Amps): 20 Amp, Display : Digital, Operating Temperature: -10 to 55, Power/Voltage: 110 - 240VAC all as directed by Engr-in-Charge
Supply & fix in repairs of Industrial highbay integral LED fittings of capacity 120 watt complete and all accessories at top of any height of workshop hanger including proper hanging fixing with angle/rond bar flat iron with clamping as good appearance complete all as specified and directed by Engineer-in-Charge. Make- Havells /Philips / Jaquar
S&F in repairs LED driver for street light / highbay light fitting / flood light from 45 watt to 150 Watt 230 volt of any type and size etc to match with existing complete all as specified and directed by Engineer-in-Charge. Make:- Havells /Philips / Jaquaror as per sample at site
Taking down old fittings. Supply and fix of LED lights fittings 09 Watt robustly designed IP65 of length 0.8 mtr with die cast aluminium housing, polycarbonate cover, single phase, 50Hz complete with all accessories including, all as specified and directed by Engineer-in-Charge. Make : Jaquar / Philpis / Havells
Taking down old unserviceable fitting. S&F of new 120 Watt LED flood light with pressure die cast aluminium housing with lens (IP 65 rating)) ,complete with all accessories i.e. nuts, bolts, washers etc items included and errection charge of pipe in hard stand Make- Havells /Philips / Jaquar
Supply and fixing in repair Steel tubular swaged street light poles complete with pole arms 1.2 m & cast iron base plate ,finial taper plug,bolts,nuts and screws as specified type 410 SP-31 , 8.5 mtr long and painting with two coat of aluminium paint over one coat of primer on exposed surface of pole complete all as specified and directed by Engineer-in-Charge. (NOTE- Excavation & PCC will be measured and paid separately) Make of poles:- National Tubing Co./ Bombay Tubing Ltd / India Tube and Co. / Bharat Conduit & Steel Works as approved by GE.
Supply & fix in repairs hot dip galvanized anti corroded weather proof octagonal electric poles 6 mtrs long top mounting on foundation complete with base plate and final including PCC foundation as per manufacturer design with 1500 mm long Arms bracket, tapper plug,bolts nuts and screws etc as specified complete all as specified and directed including taking out existing damaged pole with street light bracket complete all as specified and directed by Engineer-in-Charge. Make of poles:- National Tubing Co./ Bombay Tubing Ltd / India Tube and Co. / Bharat Conduit & Steel Works as approved by GE.
Supply and fixing of test Link for connecting the earth pit and down conductor complete all as specified and directed by Engineer-in-Charge.
Taking down old U/S cable . Supply and fixing of in repair 1x 50 sqmm copper conductor with 0.5 mm thick PVC sheathed cable complete all as specified and directed.
Taking down old unserviceable clamp and Supply and fixing iron clamp (flate 25 x 4 MM) with nuts, bolts, washers and removing old clamps complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable bracket and Supply and fixing of new bracket for street/security light fitting made of GI pipe 25 / 40 mm light grade 1.2 m long bend to shape including two Nos of clamps nuts and bolt as required complete all as specified and directed by Engineer-in-Charge. Make : Jindal /TATA
Taking down old unserviceable bracket and Supply supply and fixing of new bracket for street/security light fitting made of GI pipe 50 mm light grade 1.2 m long bend to shape including two Nos of clamps nuts and bolt as required complete all as specified and directed by Engineer-in-Charge. Make : Jindal /TATA
M&L for straight through jointing heat shrinkable kit for cable of 240/300 sqmm 3.5 core suitable for aluminium conductor including earth work complete for LT cables complete all as specified and directed by Engineer-in-Charge. Make : 3M/ Denson/Reycham
M&L for straight through jointing heat shrinkable kit for cable of 95 to 185 sqmm 3.5 core suitable for aluminium conductor including earth work complete for LT cables complete all as specified and directed by Engineer-in-Charge. Make : 3M/ Denson/Reycham
Taking up old U/S XLPE insulated screened. PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor including Old concrete cable cover from trenches/walls/ceiling/poles etc any size complete all as specified and directed by Engineer-in-Charge.
Supply and lay Insulated screened PVC bedded, copper electric cables 1100 Volts grade with stranded Copper conductor of size 1.5 sq mm 2 core. laid in duct / along pole/wall etc including making connection complete all as specified and directed by Engineer-in-Charge. Make :Polycab/Havells/Plaza/Finolex
Supply and lay Insulated screened PVC bedded, copper electric cables 1100 Volts grade with stranded Copper conductor of size 2.5 sq mm 2 core. laid in duct / along pole/wall etc including making connection complete all as specified and directed by Engineer-in-Charge. Make :Polycab/Havells/Plaza/Finolex
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core. laid in duct / along pole/wall etc including making connection complete all as specified and directed by Engineer-in-Charge. Make :Polycab/Havells/Plaza/Finolex
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as specified and directed by Engineer-in-Charge. Make :Polycab/Havells/Plaza/KEI Note : The cost of Al thimbles/lugs and cable gland etc to be included in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as specified and directed by Engineer-in-Charge. Make :Polycab/Havells/Plaza
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as specified and directed by Engineer-in-Charge. Make :Polycab/Havells/Plaza
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as specified and directed by Engineer-in-Charge. Make :Polycab/Havells/Plaza/KEI Note : The cost of Al thimbles/lugs and cable gland etc to be included in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as directed. Make :Polycab/Havells/Plaza
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as directed. Make :Polycab/Havells/Plaza
Taking down old unserviceable MCCB . S & F MCCB, 415 volts, 03 pole of cap 63 Amps, 25 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections conforming to IEC 60947-2 , complete all as specified and directed by Engineer-in-Charge. Make - Legrand / siemens / L &T/Havells/ Strandred
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 3.5 core. laid in duct / along pole/wall including making connection complete all as specified and directed by Engineer-in-Charge Make :Polycab/Havells/Plaza
Taking down old unserviceable MCCB . S & F MCCB, 415 volts, 4 pole of cap 100 Amps, 25 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size , making connections & incliding necessary fixing /fitting tools in this qoted rate complete all as specified and directed by Engineer-in-Charge.Make - Legrand / siemens / L &T/Havells/ Strandred
Taking down old unserviceable MCCB. Supply and fiixing MCCB, 415 volts, 4 pole of cap 160 Amps, 25 KA, ICS = 100% ICU with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size, making connections & incliding necessary fixing /fitting tools in this qoted rate complete all as specified and directed by Engineer-in-Charge. Make - Legrand / siemens / L &T/Havells/ Strandred
Taking down old unserviceable MCCB . Supply and fixing MCCB, 415 volts, 3 pole of cap 250 Amps, 36 KA, ICS = 100% ICU with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size , making connections & incliding necessary fixing /fitting tools in this qoted rate complete all as specified and directed by Engineer-in-Charge. Make - Legrand / siemens / L &T/Havells/ Strandred
Taking down old unserviceable MCCB .Supply and fixing MCCB, 415 volts, 3 pole of cap 630 Amps, 36 KA, ICS = 100% ICU with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size , making connections & incliding necessary fixing /fitting tools in this qoted rate complete all as specified and directed by Engineer-in-Charge. Make - Legrand / siemens / L &T/Havells/ Strandred
S & F in replacement of MCB, SPN 40/63 Amps 10 KA capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed by Engineer-in-Charge. Make-Legrand / Siemens / GE/Havells/Schneider
Supply and fixing of MCB SP 32 - 40 Amps, 240 Volts complete all as specified and directed by Engineer-in-Charge. Make-Legrand / Siemens / GE/Havells/Schneider
Supply & fix MCB , TPN 100 Amps capacity, C Curve type suitable for 240 volts AC supply, DP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed by Engineer-in-Charge. Make-Legrand / Siemens / GE/Havells/Schneider
M&L for PCC 1:3:6 type C2 (using 20mm graded stone aggreagate) for base of pole including use and wste of form work complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete 1:2:4 for coping of pole complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed by Engineer-in-Charge.
S&F HDPE of pressure rating 6kg/cm sq pipe of 90 mm dia including necessary bends, elbows, Tees etc on cable protection complete all as specified and directed by Engineer-in-Charge. Make : Make : Suprime /Prince or equivalent approved by GE
S&F HDPE of pressure rating 6kg/cm sq pipe of 63 mm dia including necessary bends, elbows, Tees etc on cable protection complete all as specified and directed by Engineer-in-Charge. Make : Suprime /Prince or equivalent approved by GE
M&L for scraping the old paint from steel tublar poles by wire brush not more than up to 9/11 mtr length above ground level including street light arms applying one coat of steel primer and two coat of aluminium paint and marking pole no. , complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable recess mounting tube light . Supply and fixing serene tube light 2 x 2 feet panel 20 Watts LED luminary back lit recess mounting , CRCA housing white powder coated, with decorative polymer diffuser complete with accessories locking arrangement, clips , per wire for connection and fixing in falls ceiling all as directed by Engr -in-Charge. Make : Havells/ Phillips /Jaquar
Material and labour for refixng of Old uprooted lightening arrestor strips including saddling of strips with suitable saddles and nails all as directed at site by Engineer - in - Charge.
M&L in replacement Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI strips 25 x 4 mm
Taking down refixng of Old uprooted Air Termination Rods including saddling with suitable saddles and nails all as directed at site by Engineer - in - Charge.
M&L in repairs Air termination, single pointed aluminium rod 12mm dia and 300mm long
Taking down existing fitting & refixing & secure hanging of Old uprooted lightening arrestor strips including saddling of strips with suitable saddles and nails all as directed at site by Engineer - in - Charge.
Testing of earthing for earth resistance provided for various electrolde/ digital meter in panels /bldgs /main DB of building inside / motor/ DG set / transformer/ OVB/VCB/ etc all as per clause 19.146.3 of SSR part-I and recording the test results complete including providing earth megger and test leads complete all as specified and as directed. (Note :- The results are to be recorded in register as directed by Engineer-in-charge)
shubham construction
ORIENT ELECTRIC CO
NOEL ENGINEERS
AGRAWAL ASSOCIATES
Shree Ayyappa Engineering
C S Sharma and Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .