| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹60.5 LAccepted-AOC 728 1 JOGIWARA VISHAVKARMA MANDIR ROAD AMBALA CITY | AMBALA CITY | AMBALA | HARYANA | 134003 | L1 | Accepted-AOC LOWEST QUOTED BIDDER | |
| 2 | L2₹64.2 L+₹3.7 L (6.07%)Rejected-Finance D NO 65 4 64 1A KOTHA NAKKAVANIPALEM MALKAPURAM POST VISAKHAPATNAM 530011 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530011 | L2 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 3 | L3₹65.5 L+₹5.0 L (8.34%)Rejected-Finance 2165 1ST STREET L BLOCK 12TH MAIN ROAD ANNA NAGAR WEST CHENNAI 600040 | CHENNAI | CHENNAI | TAMIL NADU | 600040 | L3 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 4 | L4₹66.8 L+₹6.3 L (10.4%)Rejected-Finance | L4 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
Tender Value
₹63 L
EMD Value
₹1.2 L
Closing Date
19 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF SECUNDERABAD
CWE AF SECUNDERABAD BOWENPALLY POST SECUNDERABAD 500011
PROVISION OF OPs ROOM AT AFA HYDERABAD
2023_MES_586071_1
86708/E8
Open Tender
Civil Works
Item Rate
180 days
GE AFA HYDERABAD
AS PER NIT
9 documents required · 9 mandatory
₹1,000
GE AFA HYDERABAD
₹1.2 L
Yes
1 Jul 2023
16 Mar 2023
21 Jun 2023
16 Mar 2023
19 Jun 2023
5 Jun 2023
16 Mar 2023 - 14 Apr 2023
Amount
M&L for Surface excavation not.exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and as directed.
Surface excavation not exc 30 cm deep and avg 15 cm deep and getting out in hard / dense soil complete all as specified and as directed.
M&L for excavation over areas not exc 3.0 mtr deep and getting out in hard / dense soil complete all as specified and as directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting out in hard / dense soil complete all as specified and as directed.
M&L for excavation in trenches width not exc 1.5 mtr and depth exc 1.5 mtr but not exceeding 3.0 mtr and getting out in hard / dense Soil complete all as specified and as directed.
Excavation in trenches in any kind of soil not exc 1.5 m wide and not exc 1.5 m depth and getting out, including trimming the sides and forming bottom surface to required levels for laying cables complete all as specified and as directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Removing surplus excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed
Removing excavated material (soil) exc. 1.5 KM and not exc 5.0 KM and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and as directed.
M& L for Plain Cement concrete 1:4:8 Type D-2 mix (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for Moorum / red bajri filling in floors not exc 15 cm thick spread, levelled and rammed including watering complete all as specified and as directed.
Demolition of brick work or stone boulder masonry built in cement mortar of any description complete all as specified and as directed.
M&L for RCC M-25 as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for RCC M-25 as in columns, pillars, piers, posts and struts complete all as specified and as directed.
M&L for RCC M-25 as in beams, cantilevers, bressummers, lintels over 1.5 mtr span complete all as specified and as directed.
M&L for RCC M-25 as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M&L for RCC M-25 as in Chajjas etc complete all as specified and as directed.
M&L for RCC M-25 as in Fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade, and the like complete all as specified and as directed.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions square, rectangular or polygonal for rough finished surfaces of concrete complete all as specified and as directed.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces of concrete flat complete all as specified and directed.
M&L for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide for rough finished surfaces of concrete complete all as specified and directed.
M&L for Formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for Formwork to fins, louvers, fascia for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for Mild steel TMT bars 10 mm dia and over cut to length bent to shape required including crancking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed.
M&L for Mild steel TMT bars 6 mm to 8 mm dia cut to length bent to shape required including crancking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm complete all as specified and as directed.
Description all as per Ser Item No 28 above but as in stirrups, spaces and binders etc complete all as specified and as directed.
M&L for Anti-termite treatment, Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and as directed.
M&L for Anti-termite treatment, Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed.
M&L for Anti-termite treatment, Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed.
M&L for Anti-termite treatment,, Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wal complete all as specified and as directed.
M&L for Hardcore with broken stone or biulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M& L for 100 mm thick Plain Cement concrete 1:4:8 Type D-2 mix (using 40 mm graded stone aggregate) as in sub base flooring complete all as specified and as directed.
M&L for AAC (Autoclaved Aerated Concrete) block masonry for 200 mm thick walls, with blocks size 600 mm x 200mmx200 mm having compressive strength as per IS 2185 (Part III) and set in chemical mortar of LATICRETE or equivalent as per manufacturer’s instructions complete all as specified and as directed. Make : - BIRLA / ULTRATECH / SHREE SHAKTI / PRIME / SIPOREX / GREENWAY BUILDING MATERIALS INDIA PVT LTD
M & L for Rendering 10 mm thick on fair faces of brick work or concrete wall surfaces in CM 1:6 and rendering is to be finished even and smooth without using extra cement complete all as specified and as directed.
M & L for Rendering 5 mm thick on fair faces of concrete ceiling surfaces in CM 1:3 and rendering is to be finished even and smooth without using extra cement complete all as specified and as directed.
M & L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 and rendering is to be finished fair and even using liquid water proofing compound complete all as specified and as directed. (NOTE :- Liquid WPC shall be measured and paid separately).
Supply Only of Liquid water proofing compound of approved makes complete all as specified and as directed.
M&L for Roof treatment for in-accessible roof as under : - (i) Preparation of surfaces by removing all dust, loose particles of RCC slab. (ii) Apply polyurethane waterproofing coating on prepared concrete surface of roof slab & up to 300 mm of parapets and crumple joint including junction of roof and parapet. This stage shall be passed by the GE. Roof surface shall be left without any further treatment. (ii) Method: Cleaning the surface and applying FOSROC Nitoproof 725 (minimum 0.8 mm dft) over a priming coat of Nitoproof WB primer or equivalent product of Asian paints, M/s MC Bauchemic / CIPY / SIKA / Pidilite Dr Fixit / Thermax / STP applied as per manufacturer’s instructions. (iv) The work shall be carried out complete as per manufacturer’s specifications and application methodology. Execution to be done with authorised trained / skilled applicator of manufacturer as per technical guidance laid by manufacturer. Company bank guarantee to be given by contractor after completion of water proofing work before payment.
M&L for Roof treatment for accessible roof as under : - (i) Preparation of surfaces by removing all dust, loose particles of RCC slab. (ii) Apply polyurethane waterproofing coating on prepared concrete surface of roof slab & up to 300 mm of parapets and crumple joint including junction of roof and parapet. This stage shall be passed by the GE. (iii) Method: Cleaning the surface and applying FOSROC Nitoproof 650 PU over a priming coat of Nitoproof WB primer or equivalent product of Asian paints, M/s MC Bauchemic / CIPY / SIKA / Pidilite Dr Fixit / Thermax / STP applied as per manufacturer’s instructions. (iv) Further provide a polypropylene / polyester, nonwoven geotextile fabric of 150 gsm followed by cement screed 15 mm in CM 1:4 in slope, over 600x600 mm size, 10 mm heavy duty vitrified ceramic tiles are laid. While laiting tiles, care should be taken to see that joints between tiles are kept minimum and joints are thoroughly filled with FOSROC Nototile grout polymer based joint mortar or equivalent products of Asian paints / M/s MC Bauchemic / CIPY / SIKA / Pidilite Dr Fixit / Thermax / STP applied as per manufacturer’s instructions (v) The work shall be carried out complete as per manufacturer’s specifications and application methodology. Execution to be done with authorised trained / skilled applicator of manufacturer as per technical guidance laid by manufacturer. Company bank guarantee to be given by contractor after completion of water proofing work before payment.
M&L for applying two coats of Oil bound distemper on walls including reparation of new plastered surfaces over a coat of alkali esistant primer over applying 3 mm thick wall care putty complete all as specified and as directed.
M&L for applying two coats of Oil bound distemper on ceilings including reparation of new plastered surfaces over a coat of alkali resistant primer over applying 3 mm thick wall care putty complete all as specified and as directed.
M&L for Preparing newly plastered surfaces of walls and applying two coats of cement based paint over a priming coat complete all as specified and as directed.
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win?dowcills, cooking platforms, counter wash basins and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including necessory cutting, moulding edges etc complete all as specified and as directed.
M&L for 25 mm thick plain Cement concrete 1:2:4 type B-0, mix (using 12.5 mm graded stone aggregate) as in floor finish concrete complete all as specified and as directed.
M&L for laying 600 mm x 600 mm size 10 mm thick Vitrified Ceramic tiles non-skid / matt finish tiles of any shade, double charged in floors, set and jointed in neat cement slurry and pointed in white cement mixed with matching pigment over and including 15 mm thick screed bed in CM 1:6 complete all as specified and as directed.
M&L for laying 600 mm x 600 mm size 10 mm thick Vitrified Ceramic tiles non-skid / matt finish tiles of any shade, double charged as in skirtings, set and jointed in neat cement slurry and pointed in white cement mixed with matching pigment over 10 mm thick rendering in CM 1:4 as in screed complete all as specified and as directed.
M& L for 75 mm thick Plain Cement concrete 1:3:6 Type C-1 mix (using 20 mm graded stone aggregate) as in plinth protection laid in alternate bays not exceeding 2 Sqm each and finished fair on top without using extra cement. 6mm wide joints shall be provided throughout the thickness of plinth protection in concrete bays. All joints in bays of concrete, shall be filled with mastic filling comprising of one part of heated bitumen Vg-30 grade and 3 parts of sand (all by weight) complete all as specified and as directed.
M&L for Anodised aluminium powder Coated (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
M&L for Anodised aluminium powder coated (minimum thickness of powder coating 50 micron) (door shutters, aluminium section weighing 0.55 kg / m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed.
S & F Powder coated aluminium window and ventilator shutters of any type, description with usig standard aluminium sections as per manufacurer's recommendations, including necessary fixing cleats, locking plates, handles, latches, rollers snap beading, glazing clips, ruber neoprene packing, screws etc complete all as specified and as directed. (All auluminium sections and fittings shall be measured for payment purpose and other non aluminium items like neoprene packing, rubber beading, screws, rollers etc shall be deemed included in the rate quoted by the contractor).
M&L for 12 mm thick Toughned glass in fixed windows, partitions and similar work including cutting to shape, drilling holes required and fixing arrangements complete all as specified and as directed.
M&L for 12 mm thick Toughned glass as in hinged doors, automatic doors and similar work including cutting to shape, drilling holes required and necessary fittings like 150mm Pivot hinges stainless steel on top and bottom of glass door, glass pads at top and bottom, 300 mm long stainless steel handles on both sides,2Nos on each shutter, locking arrangements, and providing Air Force emblem on each shutter incl sanding, etching etc complete all as specified and as directed.
S&F of 5.5 mm thick Sheet glass, ordinary quality and glazing with aluminium beads (excluding beading) in square n exc 0.5 sq. m in each pane complete all as specified and as directed.
S&F 4 mm thick Figured glass, pin head type and glazing with aluminium beading in squares n.exc 0.5 sq. m in each pane complete all as specified and as directed.
S&F for Double action floor door spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and as directed.
S&F of Stainless steel wire cloth. 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
M & L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed.
M&L for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including hanging from roof slab complete all as specified and as directed.
S&F hangers 4 mm dia GI (up to 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 mm x 3 mm size 60 mm long and expansion hold fastners 12.5 mm dia.40 mm long complete all as specified and as directed.
M&L for Providing and fixing Gypsum board 12 mm thick as in ceiling fixed with screws as per manufactures instructions including two coats of oil bound distemper complete all as specified and as directed.
S&F POP cornice 150 mm wide of any description and fixed as in ceilings complete all as specified and as directed.
M&L for second class hardwood Plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads exc 13 sqcm and not exc 25 Sq cm complete all as specified and as directed.
M&L for 12 mm thick Plywood, grade BWR, type BB, fixed with screws to timber frame work with nails complete all as specified and as directed.
ML for 0.90 mm thick Decorative laminates type I, or surface finish, colour and pattern as approved complete all as specified and as directed.
M&L for preparing old wall surfaces and applying one coat of distemper oil emulsion complete all as specified and as directed.
M&L for preparing old wall surfaces and applying one coat of cement base paint complete all as specified and as directed.
Demolition of Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L for PCC Solid block masonry exc 10 cm type C1 (1:3:6) 20 mm set in CM (1:6) complete all as specified and as directed.
M&L for cement concrete cast in situ 1:2:4 type B-1 mix (using 20 mm graded stone aggregate) as in lintels upto 1..5 mtr clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded for chamfered angles and throating, complete all as specified and as directed.
M&L for rendering 10 mm in CM (1:4) and rendering is to be finished even and fair without using extra cement complete all as specified and as directed.
M & L for cement concrete 1:3:6 type C -2 mix (using 40 mm graded stone aggregate) 100 mm thick as in floor and similar work complete all as specified and as directed.
M&L for screed bed or bedding layer of 15 mm thick in cm 1:4 for laying floor finishes complete all as specified and as directed.
M & L for glossy chequered cement concrete tiles 200 mm x 200 mm x 25 mm thick (any pattern) set jointed and pointed in neat cement slurry with white cement and pigment in floors complete all as specified and as directed.
M&L for preparing new concrete surfaces over 10 cm girth or width and applying two coats of synthetic Enamel Paint (any colour) over a coat of primer complete all as specified and as directed.
S&F PVC (SWR) pipes 75 mm dia laid in weep holes complete all as specified and as directed.
M&L for preparing new masonry surfaces over 10 cm girth or width and applying three coats of white wash complete all as specified and as directed.
M&L for PCC Solid block masonry exc 10 cm in width type C1 (1:3:6) using 20 mm graded stone aggregate and set in CM (1:4) complete all as specified and as directed.
Extra for forming fair finished drain or channel 60 cm inner girth in cement concrete, using extra cement, including forms, moulds,mitred/stopped ends etc all complete all as specified and as directed.
M & L providing pre cast reinforced cement concrete 1:2:4 type B -1 mix (using 20 mm graded stone aggregate) as in cover slabs set in cement mortar 1:6 complete all as specified and as directed.
M & L for Point wiring with 1.5 Sqmm copper conductor unsheathed, multistranded, PVC insulated, single core cable FRLS with earth continuity conductor of 1.5 sqmm PVC insulated copper conductor and including rigid PVC conduit of suitable size but not less than 20 mm dia. and all conduit accessories fixed to be consealed in wall and surface of the roof etc complete all as specified and as directed for the following :-
(a) One light point controlled by one switch
(b) One ceiling / Exhaust fan / Wall Fan point controlled by one switch
(c) One socket outlet 3 pin 5 Amps by one switch independent board
Description all as per Ser item No 83 above but with 2.5 sqmm copper cable in and including PVC conduit complete all as specified and as directed for 15 A socket.
S&F of ceiling rose, three terminal, PVC/polycarbonate, insulated body, ISI marked complete all as specified and as directed.
S & F of Modular Switch socket combination 3 pin, 5 Amp flush type complete all as specified and as directed.
S & F Modular Switch socket combination 16 Amp 6 pin 3 module complete all as specified and as directed
S&F Modular Switch 1 way 6 Amp one way 230V AC complete all as specified and as directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
M&L for Earthing complete with GI earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground vertically to a depth of not less than 2.25 m below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip of size 32 mm x 6 mm as earth lead by means of brazing etc all as shown in electrical plate No 3 connected to earthing test point as specified or indicated including testing on completion. Note :- (1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. 3) All the joints should be brazed only brass nuts/ bolts/ washers can be used in the test point complete all as specified and as directed .
M&L for Sub Main wiring with two runs of 6 sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through medium grade, rigid non-metallic PVC conduit / casing & caping (as per site requirement) of suitable sizewith all necessary fittings, surface in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth duly complete all as specified and directed by Engineer-in-Charge. Note :- (i) Necessary PVC dummy plates & PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate. (ii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads. (iii) Three runs of cable and one run of PVC conduit / casing caping will be measured as one uint length.
S&F Fix MCB SP 6 to 32 A 10 KA rupturing capacity complete all as specified and as directed.
Supply and fix MCB SPN 40 to 63 AMP Amps 10 KA rupturing capacity AC 230 Volt 50 hz . complete all as specified and as directed
S&F of SPN MCB DB 8 way with 200 Amps rated bus bar SPN type 230 volts 50 Hz AC supply including suitable provision for MCB concealed in the wall (concealed) complete all as specified and as directed. (for AC-02, lighting-02)
S&F of TPN MCCB DB 4 way triple pole neutral vertical type 415 volts 50 Hz AC supply including suitable provision for 4 pole MCCB incomer, fixed to the existing wall (concealed) and making good the disturbed surface wall with the exsting wall complete all as specified and as directed.
S&F MCCB 4 pole 63 Amps, 16 KA breaking capacity, 415Volts 3-phase supply complete all as specified and as directed.
M&L for River dry sand cushioning to UG cables (8 cm deep before laying of cable and 15 cm deep over the cable) in trenches including punned thickness up to 18 cm and consolidation, complete all as specified and as directed. Note :- Punned thickness only will be considered for payment.
Supply & lay common burnt, clay building bricks, sub class 'B' designation over the sand cushioning in cable trenched for protection of cables (LT) complete all as specified and as directed
Supply, laying and testing of cable XLPE insulated LT 1100 volts grade armoured heavy duty electric cable with aluminium conductor of cross sectional area 25 sq mm 4 core including connecting to panel boards with the suitable size of aluminium lugs complete all as specified and as directed .
Suply and fix Rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. of size 25 mm dia (Communication and AFNET Connectivity) complete all as specified and as directed.
M&L for HDPE pipe 150 mm dia with all fitting and fixed complete to walls and ceilings or laid on floors / trenches / pole complete all as specified and as directed
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed.
Supply and install hi wall split units indoor / outdoor inverter type complete with cordless remote control unit and anti bacterial filter for better indoor air quality with minimum 5 star rating 2.0 TR capacity, refrigerant type R-32 with cooling and heating function complete all as specified and as directed.
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5 %, load capacity 12 Amps and suitable capacity for 2.0 Ton AC complete all as specified and as directed. Make :- V Guard (5 KVA) or equivalent approved make..
M&L for Sub Main wiring with two runs of 4 sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through medium grade, rigid non-metallic PVC conduit / casing & caping (as per site requirement) of suitable sizewith all necessary fittings, surface in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth duly complete all as specified and directed by Engineer-in-Charge. Note :- (i) Necessary PVC dummy plates & PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate. (ii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads. (iii) Three runs of cable and one run of PVC conduit / casing caping will be measured as one uint length.
Supply and fix sheet metal enclosure distribution board SPN, 4 ways 240 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs complete all as specified and as directed.
S&F white cover plate with frame 06 modular complete all as specified and as directed.
S&F white cover plate with frame 04 modular complete all as specified and as directed.
S&F white cover plate with frame 03 modular complete all as specified and as directed.
S&F Modular Metal flush box 06 modular complete all as specified and as directed.
S&F Modular Metal flush box 04 modular complete all as specified and as directed.
S&F Modular Metal flush box 03 modular complete all as specified and as directed.
MAHIRA ENGINEERING & INFRASTRUCTURE
power links
S J REDDY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .