| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.9 LAccepted-AOC H NO 3 1 197 P58 MYTINAGAR COLONY LB NAGAR HYDERABAD 500 074 | HYDERABAD | HYDERABAD | TELANGANA | 500074 | ₹32.9 L | L1 | Accepted-AOC Being L1 accepted |
| 2 | L2₹35.5 LRejected-AOC | ₹35.5 L | L2 | Rejected-AOC Being L2 not accepted |
| 3 | L3₹35.8 LRejected-AOC | ₹35.8 L | L3 | Rejected-AOC Being L3 not accepted |
| 4 | L4₹37.0 LRejected-AOC | ₹37.0 L | L4 | Rejected-AOC Being L4 not accepted |
| Sl No | Description | Qty | Unit | M/S SRIDEVI ENTERPRISES L3 | Srinivash Engineers L4 | veerender constructions L1 | TIRUMALA ENTERPRISES L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for foundation, laying of poles in trenches and getting out in hard/dense soil complete all as directed and specified. | 606 | Cum | 380 ₹2.3 L | 520 ₹3.2 L | 270 ₹1.6 L | 336 ₹2.0 L |
| 2.00 | Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as all as specified and directed. | 282 | Cum | 100 ₹28,200 | 100 ₹28,200 | 36 ₹10,152 | 86.4 ₹24,364.80 |
| 3.00 | Removal of surplus soil to a distance no exceeding 50 mtrs and depositing where directed at a lvevel not exceeding 1.5 mtrs above from the starting point complete all as all as specified and directed. | 324 | Cum | 210 ₹68,040 | 80 ₹25,920 | 45 ₹14,580 | 72 ₹23,328 |
| 4.00 | Supply and spread approved dry river sand for cable laying /foundations/Cable duct including watering and consolidation, cushioning of cable laid in trenches complete all as all as specified and directed.
Note:- Punned thickness will be measured for payment purpose. | 242 | Cum | 2,200 ₹5.3 L | 900 ₹2.2 L | 900 ₹2.2 L | 1,056 ₹2.6 L |
| 5.00 | M&L brick protection with common burnt bricks sub class ‘B’ of size 230 x 113 x 75mm for cable protection complete all as specified and directed. | 26 | 1000 Nos | 9,000 ₹2.3 L | 8,000 ₹2.1 L | 9,000 ₹2.3 L | 9,600 ₹2.5 L |
| 6.00 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core complete all as specified and directed. | 700 | RM | 120 ₹84,000 | 155 ₹1.1 L | 126 ₹88,200 | 153.6 ₹1.1 L |
| 7.00 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 3.5 core complete all as specified and directed. | 600 | RM | 200 ₹1.2 L | 278 ₹1.7 L | 225 ₹1.4 L | 278.4 ₹1.7 L |
| 8.00 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core complete all as specified and directed. | 650 | RM | 230 ₹1.5 L | 300 ₹1.9 L | 306 ₹2.0 L | 340.8 ₹2.2 L |
| 9.00 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core complete all as specified and directed. | 700 | RM | 310 ₹2.2 L | 400 ₹2.8 L | 369 ₹2.6 L | 459.84 ₹3.2 L |
| 10.00 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core complete all as specified and directed. | 350 | RM | 500 ₹1.8 L | 650 ₹2.3 L | 639 ₹2.2 L | 792 ₹2.8 L |
Updated dates
Tender Value
₹39.0 L
EMD Value
₹78,000
Closing Date
3 Mar 2026, 6:00 pmClosed
GE Golconda
GE GOLCONDA LANGER HOUSE ROAD OPP MILITARY HOSPITAL HYDERABAD TELANGANA-500 008
SPECIAL REPAIRS / REPLACEMENT OF LT OHT LINES TO LT UG CABLES AT TYPE-V, TYPE-IV, TYPE-III AND TYPE-II MD ACCN COMPLEX OF CQA (ICV) YEDDUMAILARAM UNDER GE GOLCONDA
2026_MES_751014_1
8938/E8
Open Tender
Civil Works
180 days
GE GOLCONDA
As per tender
9 documents required · 9 mandatory
₹500
GE Golconda
₹78,000
Yes
18 Mar 2026
3 Feb 2026
5 Mar 2026
3 Feb 2026
3 Mar 2026
17 Feb 2026
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for foundation, laying of poles in trenches and getting out in hard/dense soil complete all as directed and specified.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as all as specified and directed.
Removal of surplus soil to a distance no exceeding 50 mtrs and depositing where directed at a lvevel not exceeding 1.5 mtrs above from the starting point complete all as all as specified and directed.
Supply and spread approved dry river sand for cable laying /foundations/Cable duct including watering and consolidation, cushioning of cable laid in trenches complete all as all as specified and directed. Note:- Punned thickness will be measured for payment purpose.
M&L brick protection with common burnt bricks sub class ‘B’ of size 230 x 113 x 75mm for cable protection complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 Sqmm 3.5 core complete all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for end termination joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm,Indoor/Outdoor type
Supply and fix cable jointing kit for 1.1 KV grade cable for end termination joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 70 to 95 sqmm,Indoor/Outdoor type
Supply and fix cable jointing kit for 1.1 KV grade cable for end termination joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 120 to 150 sqmm,Indoor/Outdoor type
S&F Hot press moulded SMC Junction box of size 270 mm x 200 mm x 135 mm with right openable hinged door with two number aluminium bus bars mounted on porcelain insulator including clamps of MS flat iron 25 x 3 mm with bolts and nuts and including one MCB SP upto 6A, 10 KA for ON/OFF street light, fixed on pole complete all as specified and directed.
Dismanting of ACSR conductor complete all as specified and directed
Dismanting cross arms of M.S channel or angle sections/insulators etc / insd complete ass all as specified and directed.
M&L Earthing complete with galvanized steel with plate electrode 60 cm x 60 cm x 6.3mm thick buried directly in ground (earth kit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized steel strip 32 x 6 mm by means of bolts, nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part-I connected to earth test point including necessary earth work and excavation, PCC 1:3:6 type C1 using 20mm graded stone aggregate for earth chamber with RCC cover 50mm thick 1:2:4 mix type B1, using 8mm dia TMT bars reinforcement @ 140mm c/c both ways, watering funnel with GI pipe 15mm dia medium grade and protection pipe GI 40 mm dia light grade all as specified and directed. Note: Earth strip and protection pipe beyond 7.5m shall be measured and paid separately.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.32 MB
BOQ_841127.xls
BOQ • 0.28 MB
8938Tender.pdf
Tender Documents • 0.80 MB
8938NIT.pdf
Additional Documents • 0.31 MB
Download all tender documents and submit your bid