| 1.00 | Charges for dismantling the existing half round S.S. wire mesh with the frame structure of two halves of condenser ball catcher assembly provided over the Flow Control Valve in Cooling Tower and place the C.B. catcher assembly on the fan floor to facilitate for O/H of Flow Control Valve and reassembly the condenser ball catcher assembly over the FCV. | 20 | Nos | 2,300 ₹46,000 | 2,150 ₹43,000 |
| 2.00 | Charges for dismantling of existing deteriorated 500 mm dia Disc type angular valve assembly from respective hot water pipe nozzle, cleaning the pipe nozzle flange surface, lifting, positioning, and reassembling the valve. | 20 | Nos | 8,150 ₹1,63,000 | 7,950 ₹1,59,000 |
| 3.00 | Charges for dismantling, cleaning & examining of valve internal components and renewal of other worn out components such as spindle support with bush / disc support M.S. bush by cutting, removing and welding with new M.S. bush, removing the existing damaged & worn out rubber seal of the disc, cleaning and fixing the new rubber seal over the disc by using proper adhesives if necessary, and reassembling and re-commissioning of the valves in the hot water pipe lines of Cooling Tower IV. | 20 | Nos | 5,000 ₹1,00,000 | 4,700 ₹94,000 |
| 4.00 | Charges for leading, lifting, positioning and inserting the stop log gate in the cold water Outlet canal of CT-IV to facilitate the cold water dewatering work. After completion of dewatering work removing, leading and placing the stop log gate on the floor during AOH of the Unit - IV. | 1 | set | 16,000 ₹16,000 | 15,000 ₹15,000 |
| 5.00 | Charges for marking, cutting and bending to suit for various sizes of Hot water M.S pipe for Strengthening & renewal of most damaged corroded & eroded half portion of the existing Hot water header pipe lines and FCV. | 610 | kgs | 50 ₹30,500 | 40 ₹24,400 |
| 6.00 | Charges for Edge preparation and welding charges for Strengthening & renewal / Patch welding works of most damaged corroded & eroded half portion the existing various sizes of Hot water header pipe lines and FCV of MS Pipe of 8mm Thickness. | 30 | Mtrs | 700 ₹21,000 | 650 ₹19,500 |
| 7.00 | Charges for cleaning and painting with one coat of epoxy red oxide primer and Two coat of epoxy sea green one over the other with proper intervals for renewal portion of the outer surface of hot water header pipe and FCVs in Cooing Tower - IV. | 54 | M2 | 230 ₹12,420 | 220 ₹11,880 |
| 8.00 | Charges for loading and transporting the M.S Plate material from site to local workshop and back to site after completing the work including the charges for loading and unloading hire charges for T&P and consumables etc for Sl.No.5. | 2 | Nos | 3,000 ₹6,000 | 2,500 ₹5,000 |
| 9.00 | Cost of Neoprene Rubber(Black) Gasket, Size 1 M X 2 M X 5 MM thick for Sl.No. 2 | 40 | kgs | 120 ₹4,800 | 110 ₹4,400 |
| 10.00 | Cost of MS plate of size 3300 x 1630 x 10mm as per: IS 2062 for Sl.No.5 | 610 | kgs | 110 ₹67,100 | 100 ₹61,000 |
Tender Value
Refer Docs
EMD Value
₹4,700
Closing Date
4 Aug 2025, 2:00 pmClosed
Superintending Engineer /Mechanical-I/MTPS-I
Office of the Superintending Engineer / Mechanical -I Mettur Thermal Power Station- I Mettur Dam-636406
MTPS I CA CWS II Unit IV Overhauling of Flow Control Valve complete assembly and renewal of its worn out components etc
2025_EB_584229_1
CE/MTPS-I/SE/M-I/CA/OT. 164/2025-26
Open Tender
Power/Energy Projects/Products
15 days
Mettur Thermal Power Station-I / Mettur Dam
As per the Tender Specifications
4 documents required · 4 mandatory
₹0
₹4,700
Yes
30 Jan 2026
21 Jul 2025
5 Aug 2025
21 Jul 2025
4 Aug 2025
21 Jul 2025
Amount
Charges for dismantling the existing half round S.S. wire mesh with the frame structure of two halves of condenser ball catcher assembly provided over the Flow Control Valve in Cooling Tower and place the C.B. catcher assembly on the fan floor to facilitate for O/H of Flow Control Valve and reassembly the condenser ball catcher assembly over the FCV.
Charges for dismantling of existing deteriorated 500 mm dia Disc type angular valve assembly from respective hot water pipe nozzle, cleaning the pipe nozzle flange surface, lifting, positioning, and reassembling the valve.
Charges for dismantling, cleaning & examining of valve internal components and renewal of other worn out components such as spindle support with bush / disc support M.S. bush by cutting, removing and welding with new M.S. bush, removing the existing damaged & worn out rubber seal of the disc, cleaning and fixing the new rubber seal over the disc by using proper adhesives if necessary, and reassembling and re-commissioning of the valves in the hot water pipe lines of Cooling Tower IV.
Charges for leading, lifting, positioning and inserting the stop log gate in the cold water Outlet canal of CT-IV to facilitate the cold water dewatering work. After completion of dewatering work removing, leading and placing the stop log gate on the floor during AOH of the Unit - IV.
Charges for marking, cutting and bending to suit for various sizes of Hot water M.S pipe for Strengthening & renewal of most damaged corroded & eroded half portion of the existing Hot water header pipe lines and FCV.
Charges for Edge preparation and welding charges for Strengthening & renewal / Patch welding works of most damaged corroded & eroded half portion the existing various sizes of Hot water header pipe lines and FCV of MS Pipe of 8mm Thickness.
Charges for cleaning and painting with one coat of epoxy red oxide primer and Two coat of epoxy sea green one over the other with proper intervals for renewal portion of the outer surface of hot water header pipe and FCVs in Cooing Tower - IV.
Charges for loading and transporting the M.S Plate material from site to local workshop and back to site after completing the work including the charges for loading and unloading hire charges for T&P and consumables etc for Sl.No.5.
Cost of Neoprene Rubber(Black) Gasket, Size 1 M X 2 M X 5 MM thick for Sl.No. 2
Cost of MS plate of size 3300 x 1630 x 10mm as per: IS 2062 for Sl.No.5
Cost of Araldite for Sl.No. 3
Cost of Cutting gas for Sl.No. 3 & 5
Cost of Welding Electrodes for Sl.No. 3 & 6
Charges for Hire charges of Bending machine for Sl.No.5
Charge for Hire charges of Welding machine for Sl.No.6
Cost of Epoxy red oxide primer for SL.No.7
Cost of Epoxy Sea Green paint for SL.No.7
Cost of Epoxy Thinner for SL.No.7
Consumables & T & P's charges for S.No.1 to 8
SS ENGINEERING CONTRACTOR (BID ID -1418526)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid