| 1 | L1₹56.7 LAccepted-AOC 131 SANGAM NAGAR OPP NATIONAL SCHOOL SANGHVI PUNE 411027 | PUNE | MAHARASHTRA | 411027 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹60.0 L+₹3.2 L (5.71%)Rejected-AOC NO 4 AC 114 EAST OF NGEF OPP THE KARNATAKA STATE APEX CO OPERATIVE BANK KASTURI NAGAR BANGALORE 560043 | BANGALORE | BANGALORE | KARNATAKA | 560043 | L2 | Rejected-AOC Quoted rate higher than L1 Bidder | |
| 3 | L3₹60.1 L+₹3.4 L (6.01%)Rejected-AOC NO A2 1 SECOND FLOOR IST CROSS STREET AMBATTUR INDUSTRIAL ESTATE TIRUVALLUR TAMIL NADU 600058 | CHENNAI | TAMIL NADU | 600058 | L3 | Rejected-AOC Quoted rate higher than L1 Bidder | |
| 4 | Rejected-Technical NO 51 TOWN HALL 3RD STREET ARAKKONAM TAMIL NADU 631 001 | ARAKKONAM | RANIPET | TAMIL NADU | 631001 | - | Rejected-Technical Not enlisted in appropriate category |
Tender Value
₹62.5 L
EMD Value
₹1.2 L
Closing Date
24 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE NAVY CHENNAI
Commander Works Engineers Navy Military Engineer Services Fort St George Rajaji Salai Chennai600 009
87670 PROVISION OF EXTERNAL ELECTRIC SUPPLY FOR INFRASTRUCTURE OF MAFI AT ARAKKONAM UNDER GE(M) ARAKKONAM
2022_MES_570439_1
CA NO CWE/NAVY/ARK/87670/E8 OF 2022-2023
Open Tender
Miscellaneous Works
Item Rate
180 days
Arakkonam
As per NIT/Tender document
10 documents required · 10 mandatory
₹1,000
GE MAINT ARAKKONAM
₹1.2 L
Yes
6 Mar 2023
21 Dec 2022
26 Jan 2023
21 Dec 2022
24 Jan 2023
11 Jan 2023
21 Dec 2022 - 28 Dec 2022
Amount
SCHEDULE 'A' PART-I [ EXT ELECTRIC WORKS]
Supply,installation,testing and commissioning indoor type of HT 11 KV, 3 phase, 50 cycles Bus coupler cum Bus raiser panels consisting of 400 Amps, 250 MVA 11 KV - 01 No metal clad air insulated switch gear suitable for existing HT VCB Panels to couple and existing Make of VCB panels is Crompton Greaves including necessary extension bus bar arrangements complete all as specified and as directed. Make : Crompton Greaves or as specified in List of makes as approved by GE Note: (a) The Panel shall be manufactured by OEM. All certificates from OEM shall be submitted before and after installation. (b) Any other parts/items not specified above but have been required essential for smooth and safe function of the panel system shall be deemed to be included in the quoted rate. (c) Design and GA drawings duly indicate the list of components and shall be prepared as recommended by the OEM and be got approved from GE before commencement the work and the rate quoted is deemed to include for the same. (d) Any civil works required to complete the work shall be deemed to be included in the quoted rate. (e) Testing of the panel system as per IS to be carried out by Rep. of Accepting officer before dispatch from factory. (f) The panel system shall be tested as per IS by Rep. of Accepting officer after installation at work site & before taking into charge.
Supply, installation,testing and commissioning of line up 5 of 4 pole drawn out electrically operated Air circuit breaker including electrically draw out type of capacity 1250A 50Ka /1 Sec @ 440 V AC - 03 Nos for incoming (For Mains,DG-1 and DG-2 supply ) and electrically operated Air circuit breaker including manually draw out type of capacity 1000A 50Ka /1 Sec @ 440 V AC - 02 Nos for out going ( for PS-1 LV Distribution panel via stabilizer and isolation transformer and one as a bus coupler)with electrically interlocking and mechanically interlocking system for each ACB, so that if one input out of three (DG-1, DG-2 and Mains) is closed then other two inputs will not be permitted to close. Say Mains I/P ACB is closed then DG-1 and DG-2 ACB’s will not close Similar hard wired circuit system needs to be made for DG-1 and DG-2 input ACB’s” with microprocessor based triping coil sysytem against Short circuit, instantaneous and earth fault protection along with motor mechanism,closing coil, shunt release and instaneous under voltage relay release pre trip alaram , 3 nos NO & 03 Nos NC element for DG and mains supply auto operation and interlocking and indvidual fault LED indications all as specified and directed. Make: Schnider/SIMENS/L& T /ABB Specification for ACB Panel:- Each ACB panel bay shall be equipped with (i) Multifunction meter : Each bay will display current / voltage through MFM of make Elite/ Secure, Conserve/ Schneider. (ii) Local/ Remote switch : Panel need to be equipped with local/ remote switch with wiring of remote up to terminal block. (iii) Indication : Green (ON) & Red (OFF) indication on each ACB panel console.
Item No.03 Conte.... (iv) Hard wire interlock : Among DG-1, DG-2 and Main ACB comes in force, if L/R switch is on remote and as soon as turned to local then it can be controlled manually from TNC (Trip, Neutral, Close switch). (v) Extended cable Bus bar : 400 sq mm, 3.5 core Aluminium XLPE, 3 runs of cable going to be terminated in each of the DG-1, 2 feeders, hence proper bus bar chamber size to accommodate all cables. (vi) Type of Bus bar : Output Copper/ Aluminium Bus bar to cater 750 KVA full load. (vii) PLC Interlock : Wiring need to be provided for remote close, remote trip, U/V inside panel up to outgoing terminals of each ACB panels with at least 3 Nos + NC Aux contacts wired up to terminal block so that can be used for further remote interlock. (viii) Inter panel hard wired Interlock : will be provided by ACB Panel builder considering closing circuit interlocks as detailed above.” Note : (i) Cost includes necessary fabrication and modification to Panels and bus bars for fixing the ACB (ii) All LT ACB's having facility of closing coil, tripping coil, under volatge relay, 03 Nos NO & 03 nos NC element for DG and mains supply auto operation and inter locking) (iii)Any other parts/items not specified above but have been required essential for smooth and safe function of the panel system shall be deemed to be included in the quoted rate.
Supply,Install,Testing and commissioning of self supporting totally enclosed mounted on Base channel of size 75 mm x 75 mm x5mm factory made Indoor type LT Panel from CPRI certified Panel builder factory fabricated made out of not less than 2 mm thick CRCA sheet ,dust and vermin proof, hinged smoothly openable front and rear, with neoprene rubber gasket, epoxy powder coated including danger plate, earth strip (32 x 6 mm) connecting provision - 02 Nos, ventilation louvers, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers etc panel board suitable for 3 phase 4 wire ,415 volts 50 hz, panel size shall be suitable for mounting and including the following items complete all as specified and directed. ( Location - Proposed ACBs required in ACB Panel at MAFI PS-1 for DG and Mains supply change over )
Item No.04 Cont....... (i) LT ACB 4 Pole, 415 V, 50 KA/1 Sec Electrically Draw out type with microprocessor release of capacity 1000 Amps complete - 01No. ( Incomer) (ii)Aluminium Bus Bar of 1500 Amp rating main bus @ 50 KA supported in suitable size porcelain strand lock with suitable size brass nut, bolt and washers with colour coded PVC sleeving for three phase and neutral -01 Set. (iii) LT ACB 4 Pole, 415 V, 50 KA / 1 Sec Electrically Draw out type with microprocessor release of capacity 630 Amps complete - 02Nos. ( out going feeder)(CCR) (iv) MCCB , adjustable type thermal relelase 100 Amps 4Pole, 50 Hz, 415 Volts with rupturing capacity 50 KA - 02 Nos (v) MCCB , adjustable type thermal relelase 25 Amps ,4Pole, 50 Hz, 415 Volts with rupturing capacity 50 KA - 08 Nos (vi) MCCB , adjustable type thermal relelase 63 Amps ,4 Pole , 50 Hz, 415 Volts with rupturing capacity 50 KA - 02 Nos (vii) MCCB , adjustable type thermal relelase 32 Amps ,4 Pole , 50 Hz, 415 Volts with rupturing capacity 50 KA - 04 Nos (viii) MCCB , adjustable type thermal relelase 16 Amps ,4 Pole , 50 Hz, 415 Volts with rupturing capacity 50 KA - 02 Nos (ix) Digital voltmeter - 1 Nos (x) Resin cast current Transformer - 3Nos (xi) Digital Ammeter with ct ratio -/5A,Cl-1.0 - 3 Nos (xii) LED Phase Indication Lamps for R,Y,B -3 Nos. (xiii) Earth bus of size 32 x 6 mm in the panel - 2 nos
Supply,Fabricate,Install,Testing and commissioning of self supporting totally enclosed mounted on Base channel of size 75 mm x 75 mm x5mm factory made Indoor type LT Panel from CPRI certified Panel builder factory fabricated made out of not less than 2 mm thick CRCA sheet ,dust and vermin proof, hinged smoothly openable front and rear, with neoprene rubber gasket, epoxy powder coated including danger plate, earth strip (32 x 6 mm) connecting provosion - 02 Nos, ventilation louvers, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers etc panel board suitable for 3 phase 4 wire ,415 volts 50 hz, panel size shall be suitable for mounting and including the following items complete all as specified and directed. (Location - Proposed out going breakers required at PS-2 LV Distribution Panel)
Item No.05 Cont....... (i) MCCB 4 Pole, 415 V, with rupturing capacity 50 KA adjustable type thermal relelase of capacity 350 Amps complete - 01No. ( Incomer) (ii)Aluminium Bus Bar of 600 Amp rating main bus @ 50 KA supported in suitable size porcelain strand lock with suitable size brass nut, bolt and washers with colour coded PVC sleaving for three phase and neutral -01 Set. (iii) MCCB , adjustable type thermal relelase 25 Amps ,4Pole, 50 Hz, 415 Volts with rupturing capacity 50 KA - 06 Nos (iv) MCCB , adjustable type thermal relelase 16 Amps ,4 Pole , 50 Hz, 415 Volts with rupturing capacity 50 KA - 06 Nos (v) Digital voltmeter - 1 Nos (vi) Resin cast current Transformer - 9 Nos (vii) Digital Ammeter -/5A,Cl-1.0 - 1 Nos (viii) LED Phase Indication Lamps for R,Y,B -3 Nos. (ix) Earth bus of size 32 x 6 mm in the panel - 2 nos
Material and labour for earthing complete in positions with GI earth plate electrode of size 600x600x6mm thick buried directly in ground vertically to a depth of not less than 2.25m below ground level, with top edge of the earth plate at a depth of not less than 1.5m below ground connected to GI earth strip 32x6mm by means of GI bolts and nuts, check nuts, washers and GI earth strip protected by GI pipe light grade 40mm bore upto 7.5m and connecting to VCB's / transformer's etc., as per site requirement including necessary excavation, earth work in any type of soil, PCC M-10 type C-1, earth chamber, 50mm thick RCC M-20 cover with 6mm dia MS bars 10 cm C/C on both ways as reinforcement complete all as shown in electrical plate No.3 of MES SSR part-I complete all as specified and as directed and testing on completion and earth resistance shall not more than 2 Ohm. Note: Quoted rate deemed to include necessary earth work, PCC chamber, RCC cover, reinforcement, removal of surplus soil, site clearance, etc.,If desired earth resistance is not obtained, the contractor shall re-execute the earthing without any additional cost.
Sai Ram Builders
Sree Nandhees Technologies Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .