| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-AOC SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L1 | Accepted-AOC Amount Awarded | |
| 2 | L2₹40.3 L+₹4.1 L (11.2%)Rejected-Finance PULGAON | L2 | Rejected-Finance Other than Lowest bidder | |
| 3 | L3₹41.3 L+₹5.1 L (13.9%)Rejected-Finance 011 NAGAREWADI 612 NAGAREWADI POST PADALI TALUKA SHIRUR KASAR DISTRICT BEED 413249 BEED MAHARASHTRA 413249 UDYAM MH 05 0079863 | BEED | MAHARASHTRA | 413249 | L3 | Rejected-Finance Other than Lowest bidder | |
| 4 | L4₹42.0 L+₹5.7 L (15.7%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L4 | Rejected-Finance Other than Lowest bidder | |
| 5 | L5₹44.7 L+₹8.5 L (23.4%)Rejected-Finance 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L5 | Rejected-Finance Other than Lowest bidder |
| Sl No | Description | Qty | Unit | M/S Maa Durga Constructions,Pulgaon L2 | metro electrical services L4 | Paragon Electrotechnics L5 | Rama Electricals L1 | MAHARASHTRA ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking out HT XLPE/PVC insulated armoured cable, including all joints of any size, from trenches, walls, or roofs, complete with removal of brick protection, sand cushioning from trenches, and making the area clear, all complete as directed by Engineer-in-Charge | 444 | RM | 25 ₹11,100 | 15 ₹6,660 | 20 ₹8,880 | 10 ₹4,440 | 7 ₹3,108 Lowest |
| 2.00 | Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft/loose soil or any type soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge. | 171 | Cum | 200 ₹34,200 Lowest | 200 ₹34,200 Lowest | 200 ₹34,200 Lowest | 200 ₹34,200 Lowest | 200 ₹34,200 Lowest |
| 3.00 | M&L for Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm in hard/dense soil. complete all as specified and directed by EIC. | 134 | Cum | 50 ₹6,700 | 35 ₹4,690 Lowest | 40 ₹5,360 | 80 ₹10,720 | 86 ₹11,524 |
| 4.00 | Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and directed by EIC. | 37 | Cum | 100 ₹3,700 | 35 ₹1,295 Lowest | 40 ₹1,480 | 80 ₹2,960 | 100 ₹3,700 |
| 5.00 | Material and labour for sand cushioning with dry river sand or crush sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming complete all as specified and directed.
Note : Punned thickness only shall be measured and paid. | 32 | Cum | 1,150 ₹36,800 | 900 ₹28,800 Lowest | 1,600 ₹51,200 | 900 ₹28,800 Lowest | 1,300 ₹41,600 |
| 6.00 | Material and Labour for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation of pole upto ground level complete all as directed by Engr-in-Chrage. | 0.5 | Cum | 4,000 ₹2,000 | 3,000 ₹1,500 Lowest | 4,000 ₹2,000 | 3,000 ₹1,500 Lowest | 3,000 ₹1,500 Lowest |
| 7.00 | Material and Labour for PCC 1:2:4 type D-2 using 20mm graded stone aggregate as in foundation of pole upto ground level complete all as directed by Engr-in-Chrage. | 0.5 | Cum | 4,500 ₹2,250 | 3,000 ₹1,500 Lowest | 6,000 ₹3,000 | 3,000 ₹1,500 Lowest | 4,000 ₹2,000 |
| 8.00 | Supply and lay un-reinforced precast concrete cable cover, class HV, type 1, flat of size 300 X 180 X 40mm for HT cable and laid dry in trenches over underground cables complete all as specified and directed | 2,111 | Each | 38 ₹80,218 | 30 ₹63,330 | 30 ₹63,330 | 65 ₹1,37,215 | 29 ₹61,219 Lowest |
| 9.00 | Relaying only old un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm obtained from excavation complete all as specified directed by EIC. | 200 | Each | 5 ₹1,000 Lowest | 10 ₹2,000 | 5 ₹1,000 Lowest | 5 ₹1,000 Lowest | 5 ₹1,000 Lowest |
| 10.00 | Supplying, laying, jointing, testing and commissioning in replacement of old vintage 11 kV grade XLPE insulated, screened, PVC bedded, galvanized steel strip/wire armoured heavy-duty electric power cable with multistranded aluminium conductors, conforming to IS 7098, suitable for HT 11 kV (E) system, of size 3 core × 120 sqmm, laid in trenches and/or fixed to pole, transformer, VCB, etc., including necessary jointing and testing, complete in all respects as specified and directed by Engineer-in-Charge.
Note: Excavation, earthwork, cable protection, sand filling, and cable jointing shall be measured and paid separately. | 483 | RM | 1,471 ₹7,10,493 Lowest | 2,000 ₹9,66,000 | 1,600 ₹7,72,800 | 1,636 ₹7,90,188 | 1,653 ₹7,98,399 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
18 Apr 2026, 6:00 pmClosed
CWE Nagpur
Commander Works Engineer Bldg No. P-9, Sitabuldi Fort, Nagpur - 440 001 Pin-900419, C/o 56 APO
REPAIR REPLACEMENT OF 11 KV CABLES, OH LINES, DEHYDRATION OF TRANSFORMER, HT SWITCH, GEAR, CTS, PTS, AB SWITCH, VCB AND MISC WORKS AT ASD, BSD AND DSD, FSD, CBU AND PERIMETER AREA UNDER GE PULGAON.
2026_MES_758186_1
86590/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Pulgaon
As per tender documents
9 documents required · 9 mandatory
₹500
GE PULGAON
₹1 L
Yes
6 Jun 2026
28 Mar 2026
20 Apr 2026
28 Mar 2026
18 Apr 2026
11 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Taking out HT XLPE/PVC insulated armoured cable, including all joints of any size, from trenches, walls, or roofs, complete with removal of brick protection, sand cushioning from trenches, and making the area clear, all complete as directed by Engineer-in-Charge | - | RM | - | - |
| - | Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft/loose soil or any type soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge. | - | Cum | - | - |
| - | M&L for Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm in hard/dense soil. complete all as specified and directed by EIC. | - | Cum | - | - |
| - | Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and directed by EIC. | - | Cum | - | - |
| - | Material and labour for sand cushioning with dry river sand or crush sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming complete all as specified and directed.
Note : Punned thickness only shall be measured and paid. | - | Cum | - | - |
| - | Material and Labour for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation of pole upto ground level complete all as directed by Engr-in-Chrage. | - | Cum | - | - |
| - | Material and Labour for PCC 1:2:4 type D-2 using 20mm graded stone aggregate as in foundation of pole upto ground level complete all as directed by Engr-in-Chrage. | - | Cum | - | - |
| - | Supply and lay un-reinforced precast concrete cable cover, class HV, type 1, flat of size 300 X 180 X 40mm for HT cable and laid dry in trenches over underground cables complete all as specified and directed | - | Each | - | - |
| - | Relaying only old un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm obtained from excavation complete all as specified directed by EIC. | - | Each | - | - |
| - | Supplying, laying, jointing, testing and commissioning in replacement of old vintage 11 kV grade XLPE insulated, screened, PVC bedded, galvanized steel strip/wire armoured heavy-duty electric power cable with multistranded aluminium conductors, conforming to IS 7098, suitable for HT 11 kV (E) system, of size 3 core × 120 sqmm, laid in trenches and/or fixed to pole, transformer, VCB, etc., including necessary jointing and testing, complete in all respects as specified and directed by Engineer-in-Charge.
Note: Excavation, earthwork, cable protection, sand filling, and cable jointing shall be measured and paid separately. | - | RM | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.54 MB
BOQ_849234.xls
BOQ • 3.22 MB
TenderDoc90.pdf
Tender Documents • 0.99 MB
corrigendum_1.pdf
PDF • 1.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .