| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹20.4 LAccepted-AOC | L-1 | Accepted-AOC Lowest Bidder | |
| 2 | L-2₹23.9 L+₹3.6 L (17.6%)Rejected-Finance H NO 177 GOVINDPURA SATWARI JAMMU CANTT 180003 J K | JAMMU | JAMMU AND KASHMIR | 180003 | L-2 | Rejected-Finance Other than lowest bidder | |
| 3 | L-3₹25.1 L+₹4.7 L (23.2%)Rejected-Finance H NO 2049 HANUMAN COLONY NEAR TCP 3 HISAR CANTT PIN 125006 HARYANA | HISAR | HARYANA | 125006 | L-3 | Rejected-Finance Other than lowest bidder | |
| 4 | L-4₹26.8 L+₹6.5 L (31.8%)Rejected-Finance | L-4 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹53,800
Closing Date
5 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Jammu
GE Jammu c/o 56 APO Pin-900277
PROVISION OF TECHNICAL STORE SECTION (TSS) FOR ORD STORE AT PRATAP LINES IN MIRAN SAHIB UNDER GE JAMMU
2022_MES_544063_1
GEJC-43/2022-23
Open Tender
Civil Works
Item Rate
200 days
Aor of GE Jammu
Please refer Tender Documents
9 documents required · 9 mandatory
₹500
GE Jammu
₹53,800
Yes
18 Oct 2022
8 Aug 2022
7 Oct 2022
8 Aug 2022
5 Oct 2022
22 Sept 2022
Amount
B/R Portion: - Surface dressing not exceeding 15 cm deep in hard dense soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in hard / dense soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0 m deep and getting out in hard / dense soil complete all as specified and as directed.
Material and labour for PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in mass concrete in foundation complete all as specified and directed.
Material and labour for brick work with fly ash bricks old size, straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and directed.
Material and labour for brick work with fly ash old size bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:4) as in partition walls complete all as specified and directed.
Material and labour for RCC M-25 design mix (using 20mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
Material and labour for RCC M-25 design mix (using 20mm graded crushed stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed.
Material and labour for RCC M-25 design mix (using 20mm graded crushed stone aggregate) as in chajjas complete all as specified and directed.
Material and labour for RCC M-25 design mix (using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressumers, lintels over 1.5m span complete all as specified and directed.
Material and labour for RCC M-25 design mix (using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Material and labour for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar works, vertical or to batter complete all as specified and directed.
Material and labour for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams etc complete all as specified and directed.
Material and labour for formwork to sides of pillars, posts, struts, piers, columns and stanchions square / rectangular complete all as specified and directed.
Material and labour for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (Horizontal or Sloping) complete all as specified and directed.
Material and labour for formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed.
Material and labour for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC / PCC bands in walls, horizontal or sloping and similar work exceeding 10 cm but not exceeding 20 cm wide complete all as specified and directed.
Material and labour for TMT bars 6 to 8mm, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Material and labour for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Material and labour for TMT bars 5 to 8 mm dia as in stirrups, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Material and labour for 15mm thick rendering in CM (1:6) on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Material and labour for rendering 15mm thick on fair faces of brick / concrete surfaces built in CM (1:4), finished even and smooth without using extra cement complete all as specified and directed.
Material and labour for 5 mm thick rendering in CM (1:3) on fair faces of brick work or concrete surfaces on ceiling finished even and smooth without using extra cement complete all as specified and directed.
Material and labour for preparation of new surface and applying two coats of oil bound distemper on new plastered surface over 1 mm thick putty complete all as specified and directed.
Material and labour for preparation of new surface and applying two coats of exterior emulsion / weather proof paint over a coat of primer over and including 1 mm thick putty on plastered surface complete all as specified and directed.
Material and labour for preparation of surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in each layers hard / dense soil complete all as specified and as directed.
Removing excavated materials in soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed.
Material and labour hard core of gauge of broken boulders exceeding 63mm but not exceeding 100mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rolled / rammed to a true surface complete all as specified and directed.
Material and labour for PCC 75 mm thick (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as sub base to floor complete all as specified and directed.
Material and labour for PCC 75mm thick (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as sub top layer complete all as specified and directed.
Material and labour granolithic concrete (1:1:2) floor topping 30mm thick laid over cement concrete sub floors etc and finished to even and fair surface complete all as specified and as directed.
Material and labour for machine cut kota stone slab flooring 18 to 20mm thick as in floor to match the shade of the slab including 20 mm screed bed in CM (1:6) including rubbing, polishing complete all as specified and directed.
Material and labour for machine cut kota stone slab flooring 18 to 20mm thick as in riser in step, skirting / dado to match the shade of the slab including rubbing and polishing over and including 10 mm rendering in CM (1:4) complete all as specified and directed.
Material and labour for vitrified tiles any colour 10 mm thick (square / rectangular) polished as in floor, area of each tile not exceeding 0.36 Sqm etc set and jointed in neat cement slurry and pointed in coloured cement to match, pattern, laying etc off tiles and shade, colour shall be decided by Engineer-in-Charge complete all as specified and directed.
Description same as per Ser Item No 35.00 here-in-before but in vertical surfaces including 10 mm thick cement rendering / backing coat of cement in CM (1:4) complete all as specified and as directed.
Material and labour for 16 to 18 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing into white cement (1:2) using marble dust with admixture of pigment to match shade of granite over and including 20 mm thick screed bed of CM (1:6) including taking down old complete all as specified and directed.
Material and labour for 75 mm thick PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) in plinth protection laid in alternative bays finished even and smooth without using extra cement including making 10 mm wide grooves to full depth at 3 m interval and at every change of direction and filling the grooves with mixture of bitumen and sand mixed in the ratio of (1:3) by weight and top 10 mm depth sealed with sealing compound grade 'A' complete all as specified and directed.
Material and labour for 10 mm thick cement plaster in CM (1:3) over concrete surface finished even and smooth without using extra cement mixed with water proofing compound pidi proof LW @ 200 ml per 50 Kg cement as per manufacturer's instructions complete all as specified and directed by Engineer-in-Charge. Note: - Rates quoted are including water proofing compound.
Material and labour for water proofing treatment provided with polymeric water proofing membrane 90 micron weighing not less than 3 Kg / Sqm on prepared surfaces vertical / horizontal laid over a coat of bitumen 85/25 @ 1.20 Kg / Sqm, over a coat of bitumen primer 0.50 Kg / Sqm one coat of bitumen 85/25 @ 1.20 Kg / Sqm shall be provided over water proofing membrane as per manufacturer instructions complete all as specified and directed by Engineer-in-Charge.
Material and labour for applying two coats of aluminium paint on roof treatment complete all as specified and directed.
Supply only water proofing compound complete all as specified and as directed.
Supply and fixing 18mm thick factory made 100 % solid WPC flush shutter (for cupboard and vanity etc) made from co-extruded three layer rigid foam sheet (single extruded) with 0.8 to 1 mm thick outer layer having density not less than 1400 Kg / Cum and density of central core not less than 600 Kg / cum manufacturer by an ISO : 9001 / 2015 certified company complete all as specified and directed.
Supply and fixing 30mm width of flaps (when open) continuous (piano) hinges mild steel bright finish or electro galvanised complete all as specified and directed.
Supply and fixing 40mm dia cupboard knobs fixed with nut and washer brass polished bright finished complete all as specified and directed.
Supply and fixing aluminium powder coated aluminium door shutters with frame (frame sections not less than 3 mm thick, shutter sections not less than 2 mm thick). Bottom half panel filled with 8 mm thick prelaminated particle board and top half portion covered with 5.5 mm thick frosted glass including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 No's in each door, hinges, anodised aluminium snap beading, screws, two way floor door spring, mortise lock with keys etc complete all as specified and directed.
Supply and fixing aluminium powder coated four track sliding window shutters (two tracks for glazed shutters and two tracks for fly proof shutters) glazing with 5.5 mm thick plain sheet glass and gauging with aluminium wire mesh of dia 0.45 mm and aperture 1.40 mm with sections of minimum 2 mm thick including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specified and directed.
Material and labour for cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in surface channels complete all as specified and as directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement complete all as specified and directed.
Supply and fixing mild steel framed works such as grills, framed guard bars, etc and similar works as in cooler stands etc conforming to Fe 290 grade 'E' 165 complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in hard / dense soil complete all as specified and directed.
Material and labour for 100 mm thick cement concrete (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in sub base complete all as specified and directed.
Material and labour for 60 mm thick machine pressed precast concrete interlocking paver block (M-35 grade) any shape, providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design and pattern as in footpath, parks, lawns, drive ways or light traffic parking etc of required strength, thickness and size / shape, made by table vibratory method using PU mould, laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding / laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
Material and labour for 100 mm thick cement concrete (1:2:4) (using 40mm graded crushed stone aggregate) as in pavement / hard standing / ramp finishing the surface even and fair complete all as specified and directed.
Demolition of concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
E/M Portion: - Material and labour for point wiring one light point or one fan point controlled by one switch complete with 1.50 Sqmm copper conductor multistranded PVC insulated FRLS and unsheathed cable in existing PVC rigid concealed conduit with new cast iron / pressed steel sunk terminal box covered with 3 mm thick laminated sheet hylam brand IS-2036 marked with continuous PVC insulated multistranded copper wire 1.50 Sqmm dia FRLS PVC insulated complete all as specified and directed.
Description all as per Ser item No 56.00 here-in-before but for multi 5 pin 5 amp socket outlet on same board complete all as specified and directed.
Description all as per Ser item No 56.00 here-in-before but for multi 3 pin socket outlet 5 amp socket on independent board complete all as specified and directed.
Description all as per Ser item No 56.00 here-in-before but for multi 3 pin 15 Amp socket outlet independent controlled by 15 Amp switch with 2.5 Sqmm copper conductor multistranded cable PVC insulated FRLS and unsheathed cable in and including PVC rigid concealed conduit 20/25mm dia and unsheathed copper conductor multistranded cable 2.5 Sqmm as earth wire FRLS PVC insulated in green colour all as directed by Engineer-in-Charge complete with new CI / pressed steel sunken black with hylum top sheet cover all as specified.
Supply and fixing socket outlet 5 pin, 5 Amp, flush type complete all as specified and directed.
Supply and fixing switch piano, flush type, single pole one way 5 Amp, 240 Volts complete all as specified and directed.
Supply and fixing ceiling rose, 3 phase / PVC / polycarbonate isolated body complete all as specified and directed.
Material and labour switch piano, flush button, single pole, one way 15 Amp complete all as specified and directed.
Material and labour socket outlet 3, 5 pin and 15 Amp multi purpose shuttered type complete all as specified and directed.
Material and Labour for fan regulator stepped electronic type suitable for AC, 240 Volts complete all as specified and directed.
Material and Labour lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Material and labour self ballast LED retrofit lamp with PVC body and PC Diffuser 9 watt 230 Volt 6500 K complete all as specified and directed.
Supply and fixing LED fitting 1 X 20 W, 220 V, AC decorative box type complete with LED tube rod 20 watts driver, holder and power factor > 0.95, 100 Lumen / Watt, 6500 K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete (4' ft long) with LED rod 20 watt, 230 Volts, 50 Hz complete all as specified and directed.
Supply and fixing LED light fitting 1 X 9 W / 1 X 10 W bulk head luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, minimum air delivery 210 CFM with service value 6.0 BEE, dust resistant, having smart feature i.e. remote controlled like boost, sleep, speed control and timer mode, five star rated with brushless direct current motor (BLDC) conforming to ISI complete all as specified and as directed.
Supply and fixing exhaust fan, steel body AC single phase, 230 V of size 300 mm sweep with, blades and frame and louvers complete all as specified and directed.
Material and labour distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 Volts double door complete all as specified and directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Supply and fixing SPN 40 to 63 Amp rating 240 V, 10 KA, 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection, testing and commissioning all as specified and directed.
Supply and fixing 240 Volt, 10 KA, 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 Amp, in the MCB DB complete with connection, testing and commissioning all as specified and directed.
Material and labour sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sqmm for phase and neutral and one run of 4.0 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length including taking down old wiring complete all as specified and directed. Note: - Wiring shall be done in proper colour coding.
Material and labour for earthing complete with galvanized mild steel earth plate electrode of size 600 x 600 x 6mm thick buried directly in ground earth (in vertical position) earth pit not less than 2.25 meter deep below normal ground level with top edge of the earth plate not less than 1.5 meter below ground level connected to galvanized iron or earth lead wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washer of galvanized iron including PCC pit in PCC (1:2:4) type B-1, precast RCC cover slab using reinforcement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm bore “light grade” galvanized steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR 2020 part-I connected to test point complete all as specified and directed and testing on completion.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep and making good bottom suface for laying / removing of cable complete all as specified and as directed in hard soil.
Supply and laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade croos sectional area 10 Sqmm, 2 core in and including taking out old one complete all as specified and as directed. Note: - (i) Earth work, sand, bricks, removing, returning, filling in, Aluminium thimbles / lugs will be paid separately. (ii) Cost of laying electrical cable through new / existing pipe under road, buildings, railway tracks, highways are included in the quoted rates. (iii) All equipments, machinery or tools if required for laying electrical cable through new / existing pipes are provided by the contractor without any extra cost.
Material and labour sand filling in cushioning bed of cable and consolidation complete all as specified and as directed.
Supply and laying common burnt clay building sub class 'B' bricks, laid over sand cushioning laid at right angle along with cable complete all as specified and as directed.
Supply and laying galvanised iron light grade of size 40 mm including all accessories for encasing cables for mechanical protection, laid under plinth / floors / path culverts with complete accessories such as bends / sockets / reducers / saddles including neceesary threading / drilling works complete all as specified and as directed.
NOTE NO 1: - Samples of materials as approved will be kept in GE's sample room. NOTE NO 2: - All fittings and fixtures mentioned above will be fixed to the satisfaction of Engr-in-Charge and GE. NOTE NO 3: - Warranty certificate to the Engineer-in-Charge where ever applicable shall be submitted by the Contractor at the time of fittings.
M/S A TO Z ENGINEERS
STAR CONSTRUCTIONS
M/S PARAMJEET SINGH
Bidder Name
STAR CONSTRUCTIONS
M/S PARAMJEET SINGH
PAKAYA BUILDERS AND DEVELOPERS PVT LTD
M/S A TO Z ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .