Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.5 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹44.3 L+₹1.8 L (4.27%)Rejected-AOC NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹45.4 L+₹2.9 L (6.79%)Rejected-AOC | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹47.3 L+₹4.8 L (11.2%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹47.9 L+₹5.4 L (12.6%)Rejected-AOC C O AKBAR FURNITURE HOUSE MALHAR MORH GARHI UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Rejected-AOC REJECTED |
Tender Value
₹42.1 L
EMD Value
₹84,500
Closing Date
31 Dec 2021, 6:00 pmClosed
GE SOUTH UDHAMPUR
GE SOUTH UDHAMPUR
GE S U 58 2021 22 SPECIAL REPAIR TO BLDG NO NP T 142 HQ BR AT 1 FOD AND SPECIAL REPAIR TO RETAINING WALL PROTECTIVE WORK AND ALLIED INFRA NEAR BLDG NO P41 NP58 OF HQ 87 MTN BDE UNDER GE SOUTH UDHAMPUR
2021_MES_493688_1
GE/S(U)-58/2021-22
Open Tender
Civil Works
Works
240 days
GE SOUTH UDHAMPUR
As per NIT documents
9 documents required · 9 mandatory
₹500
GE SOUTH UDHAMPUR
₹84,500
25 Feb 2022
10 Dec 2021
1 Jan 2022
10 Dec 2021
31 Dec 2021
24 Dec 2021
10 Dec 2021 - 20 Dec 2021
Amount
Roughing surfaces of old concrete by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tar felt and brushing neat cement slurry @ 3.0 Kg/ sqm including 10 mm thick flooring in CM (1:3) finished even and smooth mixed with water proofing compound complete all as specified and as directed. (Note:- WPC shall be measured and paid separately).
Applying bituminous primer on roof surfaces @ 0.40 ltr/sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 kg/sqm and provide modified polymeric five layered APP (Atactic Polypropylene) Modified Polymeric Membrane with 100 micron high molecular high density polythylene film. Min wt of memebrane will be 3.5 kg/sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitumen 85/25 @ 1.2 kg/sqm blinded with fine sand in dry condition @ 0.5 kg/sqm complete all as specified and directed.
AC designer composite ceiling board 4 to 6 mm thick in 600 x 600 mm panel confirming to IS-14682 type-B category-3 including GI frame, holdfast & suspenders complete all as specified and directed.
Taking down chowkats or steel frames n. exc 1.5 Sqm each (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkats or frames with shutters with fittings (without taking off shutters from the frame) of size exceeding 1.5 Sqm not exceeding 4 Sqm each including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fasts and removing from site to store or otherwise complete all as specified and directed.
Extruded aluminium allloy handles 100 mm long "D" type fixed to doors with screws complete all as specified and directed.
Aluminium anodized tower bolts 150 mm long fixed to doors with screwscomplete all as specified and directed.
300 mm long aluminium anodized sliding door bolt with hasp, staple ( bolt type ) and fixing clips, bolts and sliding bolts etc; complete all as specified and directed.
Aluminium (die cast) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutter of 851 to 1000 mm width and of weight between 61 to 80 kg complete all as specified and directed.
Mortice locks Brass vertical type size 100 mm 4 levers brass chromium plated with keys in duplicate as in repair complete all as specified and directed.
Demolition of brick work built in cement mortar including all quoins arches pillars etc complete all as specified and directed.
Brick work with sub class 'B' bricks straight or curved on plan exc. 6.00m mean radius built in cement mortor 1:6 complete all as specified and directed.
Demolition cement concrete in ground floors and paving (unreinforced) nexc. 15 cm thickness (below or above ground floor) complete all as specified and directed.
75 mm thick Plain cement concrete 1:3:6, type C-2 using 40 mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n.exc 2 Sqm each) and finished even and smooth without using extra cement and providing joints throughout the thickness of plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight, complete all as specified and as directed.
25 mm thick PCC type B-0 1:2:4, using 12.5mm graded crushed stone aggregate as in sub base finished fair for receiving floor finishes complete all as specified and directed.
Screed bed or bedding layer of mortar 15 mm thick for laying floor tiles in CM 1:4 complete all as specified and directed.
Double charged vitrified ceramic tiles 10 mm thick ( square / rectangular ) polished area of each tiles n. exc 0.36 sqm in floors etc and jointed in neat cement slurry and pointed in white or coloured cement to match the work using dark shade complete all as specified and directed.
All as per ser item No 17 above but in vertical surfaces complete all as specified and directed.
Taking down cement plaster from brick walls or concrete of any description, racking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
Rendering 15 mm thick in two layer (10+5 mm) on brick work or concrete surfaces in cement mortar 1:4 finished even and fair without using extra cement including mixing integral water proofing compound in the proportion as mentioned in manufacturer's instructions complete all as specified and directed. (Water proofing compound to be measured and paid for separately).
Preparation of new plastered or un- plastered surfaces and walls including cornices, pilasters etc and applying two Coats of cement base paint over a coat of primer complete all as specified and directed.
Rendering 10 mm thick on brick work or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of wall and apply two coat of oil bound distemper over a coat of primer including two coats of wall care putty complete all as specified and directed.
Rendering 5mm thick on brick or concrete surface as in ceiling in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and directed.
Preparation new plastered surfaces including complete Removal of existing surface of white wash and applying two coats of white wash on ceiling complete all as specified and directed.
3 mm thick sheet glass ordinary quality and glazing with oil putty in square pane complete all as specified and directed.
Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Dismentling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
18/19 mm thick pre-laminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed.
0.90 mm thick decorative choice of lamination type 1 of surface finish, colour and pattern as approved, fixed with aproved adhesive as per manufacturer's insturctions complete all as specified and directed.
Two coats of synthetic enamel paint on steel surface of any description exc. 10 cm width or girth including preparation of new surfaces, complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
M&L for Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron, complete all as specified and directed.
Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floor, complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position etc complete all as specified and directed.
Reinforced cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in slab supported on walls/chajjas and the like, complete all as specified and directed.
Reinforced cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as Beams, cantilevers, bressummers,lintels over 1.5m span, complete all as specified and directed.
Use and waste of form work to soffits of suspended slab such as roof slab, floor slab, landing and similar work not exceeding 200mm thick surface horizontal or sloping complete all as specified and directed.
Use and waste of work formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed.
TMT bars 10 mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with Mild Steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
All as per srl item No. 41 above but 5 mm dia and over including 10mm dia in stirups, spaces and binders etc complete all as specified and directed.
Aluminium drapery rods of 25 mm dia decorative type with wooden finish alongwith holding for bracket & end caps in repairs complete all as specified and directed.
Cutting holes exceeding 150 sq.cm but n.exc 400 sq.cm in to brick walls built in CM and making good in cement concrete 1:2:4 type B-1 for fixing of Cooler Brackets etc complete all as specified and directed.
Powder coated (minimum thickness of powder coating 50 micron) anodised aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
Powder coated (minimum thickness of powder coating 50 micron) anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed.
Powder coated (minimum thickness of powder coating 50 micron) anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specified and directed.
Powder coated aluminium grill/guard bars to aluminium window complete all as specified and directed.
Texture plank for walling/skirting/vertical clading plank, plain one side and edges tongued and grooved or wood head less screws rebated and fixed with nails/screws with play board size 1215 x 165 x 12 mm thick, core HDF EI (high density) 860-900 KG/M3 fox wood No. 176 or equivalent including drilling plugging to brick walls complete all as specified and directed.
50 mm thick PCC 1:4:8 Type D-2 using 40 mm graded crushed stone aggregates as in foundations filling and mass concrete complete all as specified and directed.
Sand cushioning under floors including watering and consolidation complete all as specified and directed.
Coloured machine vibro mechanically floated glossy finish interlocking cement paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with,topping of cement mixed with imported pigment,colour and shape shall be approved by GE. ISI Marked.
Providing cement concrete in steps, seismic and other similar bands, parapets and railings up to 60 cm in hieght, coping, kneeless apex stones , bed plates, kerbs not provided for including weathering, slightly rounded or chamfered angles all as directed, 1:2:4 mix type B-0 complete all as specified and directed.
Rendering 15 mm thick on brick work or concrete surfaces in cement mortar 1:4 finished even and fair without using extra cement complete all as specified and directed.
PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in surafce channel and drains complete all as specified and directed.
Extra for forming fair finished drain or channel Exc 30cm inner girth in cement concrete ,using extra cement , incl forms moulds, mitered/stopped ends etc complete all as specified and directed.
Walling of random rubble,uncoursed,well bonded,bedded and solidly hearted built in cement mortar 1:6 complete all as specified and directed.
Ditto all as per item No. 57 above but except stone complete all as specified and directed.
Providing precast cement concrete 1:2:4 type B-1 using 20 mm graded crused stone aggregate in landings, cover slab, shelves and similar articles with plain faces and set in cement mortar 1:4 complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Cement concrete (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in foundation, filling, sub base and mass concrete complete all as specified and directed.
RCC M-25 (Design mix) using 20 mm graded crushed stone aggregate as foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc. basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
RCC M-25 (Design mix) using 20 mm graded crushed stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and as directed
Formwork to flat sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
Formwork to flat sides of columns and stanchions complete all as specified and directed.
Preparation of new plastered surfaces on walls and applying two coats of cement based paint complete all as specified and directed.
PVC (SWR) pipes 110 mm bore as in weep holes complete all as specified and directed.
Preparation of any description, over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer on new steel surfaces complete all as specified and directed.
Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses incl hammer dressing with maximum depression on face from straight edge held against the dressed surface n exc.40mm complete all as specified and directed.
Flush pointing to random or polygonal rubble, uncoursed or brought upto courses in CM 1:4 complete all as specified and directed..
Providing precast cement concrete type 1:2:4 type B-0 in louvres and jallies 40 mm thick decorative design , incl all moulding but including frame set in cement mortar 1:4 complete all as specified and directed.
100 mm thick PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregates as in sub base flooring etc complete all as specified and directed.
Providing 100 mm thick, plain cement concrete (1:2:4) type B-1, using 20 mm graded crushed stone aggregate as in floors laid in separate bays complete all as specified and directed.
Framed work as in doors or gates of angle or tubular section with gusset plates, rails, braces, etc., complete drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with or including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete. Fe 410 - (Gde- E- 250) complete all as specified and directed.
20 mm thick granite ( of any type ) work ( table rubbed and polished ) in pillars and likes in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed.
Cement concrete (1:2:4) type B-2 using 40 mm graded crushed stone aggregate as in foudation, filling, sub base and mass complete all as specified and directed.
Dismanttling of plain or corrugated steel sheetings any thickess as in roof coverings complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.60mm thick crimpted/tapered at the external end slow of any colour having tensile strength 550 Mpa as in roof covering fixed with self tapping screws and caps etc complete all as specified and directed.
Rolled Mild steel joist channels, angle or tee sections, fixed independently without connecting plates etc. (cut to ordinary length, fixed with hold fast and nails to floors, and similar work welding & drilling of holes to floor for fixing of hold fast as per requirement of gde Fe-410W (Gde E-250 quality), complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
Taking down carefully, copper/ aluminum point wiring (light, fan, socket or power) complete fitting such as switch, sockets, ceiling rose, pendants socket any type, rectangular board terminal boxes etc and making good disturbed surfaces of walls floors and ceiling complete all as specified and directed.
Point wiring for one light/ fan/bell point controlled by one switch using 1.5 Sq mm FRLS copper conductor cables (multistanded) PVC insulated and unseathed in and including PVC concealed conduit as per site requirement (thickness not less than 1.5mm and 20mm dia), medium grade with Modular sunken boxes & PVC back plate for mounting modular type switches, sockets & regulators etc with front plate modular type including supplying and laying PVC insulated unsheathed 1100 volts coppper conductor cable 1.5 Sq mm as earth wire stranded and conected to earth dolly complete all as specified and directed. Note:- Cutting and making same the wall patchs after laying the wire and conduit using putty, white wash and distamper. The surface should be made smooth using putty and should match exactly with the existing wall finish.
All as per srl item No 82 but for 3 pin 6 Amps socket outlet independent board including PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly complete all as specified and directed.
All as per srl item No 82 but for 3 pin 6 Amps socket outlet on the same board including PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly complete all as specified and directed.
All as per Srl item No 82 but for 3 Pin 16 Amps socket outlet independent board with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 1.5 sq mm earth wire standard and connected to earth dolly complete all as specified and directed.
Modular switch 6 Amps single pole one way 230 V, 50 Hz, AC , with inner and outer cover strip required module complete all as specified and directed. Make: Havells/ Legrand/ANCHOR ROMA/or equivalent.
Modular switch 16 Amps single pole one way 230 V, 50 Hz, AC , with inner and outer cover strip required modulecomplete all as specified and directed. Make: Havells/ Legrand/ANCHOR/ ROMA
Modular socket 3 Pin 6 Amps flush type 230 V, 50 Hz, AC , with inner and outer cover strip required module complete all as specified and directed. Make: Havells/ Legrand/ANCHOR /ROMA
Modular socket combined 2-in-1, 6 Pin 6 & 16 Amps 230 V, 50 Hz, AC , flush type with inner and outer cover strip required module complete all as specified and directed. Make: Havells/ Legrand/ANCHOR /ROMA
Ceiling rose, surface bakelite 65 x 50 mm two to three terminals fixed on PVC Round Block complete all as specified and directed. Make: Havells/ Legrand/ANCHOR/ ROMA
Modular Bell push, flush type, 5 Amp complete all as specified and directed. Make: Havells/ Legrand/ANCHOR/ ROMA
Bell, AC, 230 volts, single pole complete all as specified and directed. Make: Havells/ Legrand/ANCHOR/ ROMA
Modular Fan regulator electronic, stepped type hum free suitable control speed of fan from 0 to 100 % and connecting electrically complete all as specified and directed. Make : Anchor/Legrand/Kinjal.
Sheet metal enclosure double door type for DBs (when MCB to be used) 12 way 240 volts with 200 Amps rated busbar and neutral link including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. Make:- Havells/ legrand/ Schneider.
Sheet metal enclosure double door type for DBs (when MCB to be used) 8 way 240 volts with 200 Amps rated busbar and neutral link including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. Make:- Havells/ legrand/ Schneider.
Sheet metal enclosure MCB distribution board Triple pole & neutral 415 volts 4 way C Curve with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. (Note-MCBs will be measured separately)
Supply & Fixing MCB TPN 100 Amp, 4 Pole, 415V C Curve complete all as specified and directed.
MCB single pole 240 volt any rating from 10 to 40 amps "C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified and directed. Make:- Havells/ legrand/ Schneider.
MCB single pole and neutral 240 volt any rating from 63 Amps "C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified and directed. Make:- Havells/ legrand/ Schneider.
Supply and fixing LED lights fitting 1x 20W, 230V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Taking down/refixing ceiling fan/Exhaust Fan including disconnection of existing connection, dismanting of blades and Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and rehanging the fan complete all as specified and directed.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 06 Sqmm in PVC concealed conduit 25mm dia including PVC insulated copper conductor cable 4 Sq mm as earth lead all as specified. Including taking down old sub main wire complete all as specified and directed.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 10 Sqmm in PVC concealed conduit 25mm dia including PVC insulated copper conductor cable 6 Sq mm as earth lead complete all as specified and directed including taking down old sub main wire.
Earthing complete with galvanised steel earth plate electode 600mm x 600mm x 6.00mm thick burried directly in ground (earth pit not less than 2.25 meter deep below normal ground level connected to and including galvanised steel earth lead wire 4 mm dia by means of bolts, nuts, chock, nuts and washers of galvanised iron or steel including PCC Pit in 1:2:4 type B-I angle iron frame with RCC cover and handle, excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mash and light grade GI protection pipe 15mm bore upto main board complete all as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected to main control board complete all as specified and directed and testing completion.
SINGH CONST CO
VIRINDER SINGH
AKBAR FURNITURE HOUSE AND TIMBER MERCHANT
M/S ASHOK KUMAR PACHIALA
BHAGWATI TRADERS
SODHI TRADING CORPORATION
RAJ MOHD
VISHWANATH AND SONS
vmd traders
khajuria builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .