Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹20.7 L+₹2.1 L (11.4%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | Rejected-Technical E 27 CWE WELLINGTON | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | - | Rejected-Technical Being not eligible due to not uploaded DD / tender cost |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
15 Feb 2024, 6:00 pmClosed
Neeraj Mehrotra, IDSE, CWE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
PROVISION OF FIRE RETARDANT FALSE CEILING, WALL PANEL AND CONNECTED WORKS AT AFTC COIMBATORE
2024_MES_637142_1
84248/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) (AF) Coimbatore
As per tender documents
7 documents required · 7 mandatory
₹500
AGE (I) (AF) Coimbatore
₹42,000
19 Mar 2024
12 Jan 2024
17 Feb 2024
12 Jan 2024
15 Feb 2024
27 Jan 2024
12 Jan 2024 - 20 Jan 2024
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep and getting out in hard/dense soil for laying of UG cables or for errection of pole complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 CM thick complete all as specified and directed.
Removing excavated materials (soils) to a distance not exceeding 50m and depositing where directed at a level not exc. 1.5 m above the starting point, complete all as specified and directed.
M&L for riddled earth filling in trenches above and below the cable as in cable protection, all as specified and directed. (Note :- Punned thickness shall be mesured and paid)
M & L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete all as specified and as directed.
S & F for Second class hard wood with plain, framed, panelled shutters 35mm thick (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats, all as specified and directed
S & F for Second class hard wood Glazed and skeleton shutters 30mm thick, open rebated and prepared to receive glass, gauze, etc. (without sash bars),but divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, all as specified and directed
S & F for Second class hard wood with plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, all as specified and directed
S & F Butt hinges medium weight cold rolled mild steel, and fixed 75 mm size, all as specified and directed
S & F Butt hinges medium weight cold rolled mild steel, and fixed 100 mm size, all as specified and directed
S&F 150mm long Extruded aluminium alloy handles, fabricated type, anodised butt hinges, heavy weight, cold rolled mild steel, all as specified and directed
S&F 200mm long Aluminium anodised barrel towers bolts of extruded section and all as specified and directed
S&F 300mm long Aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy complete and all as specified and directed
S & F Floor door stopper 140mm long with cover plate of aluminium alloy body and tongue, anodised, with hard drawn steel spring. Fixed in floor
S & F Extruded aluminium alloy handles fabricated type anodised size 100 mm, all as specifed and directed.
S & F Aluminium anodised barrel tower bolts extruded section 100 mm size, all as specifed and directed.
S & F Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S square tube, suplying and fixing in opening as per specification and drawing etc complete all as specified and as directed.
S & F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S tube for top & bottom rails. M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having PVC sheet strip of 20mm width stuck in side with solvent cement for stiles and plain colour PVC sheet for top rial, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement , suppling & fixing in the frame at site as per specification & drawing etc complete all as specified and as directed.
S&F in repairs Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of apperture 1.40 mm and fixed with stainless steel wire staples, all as specified and as directed.
S & F MS hold fast for doors and windows etc complete all as specified and directed.
S & F for framed work such as grills, gratings, etc.. With ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; conforming to Fe 290 Gde E 165, all as specifed and directed.
S & F for one hour fire rated suspended false ceiling system includes Gypsteel ULTRA perimeter channel, galvanised finish fixed with along the perimeter of existing wall/partion with impact anchor at 600mm centres including all accesseries and 50mm thick stone mineral wool of density 48Kg/m3 is laid over the ceiling section complete all as specified by manufacturer and as directed.
S & F for one hour fire rated wall panel/lining system with 62.5mm Gypliner channel includes two layer of tapered edge 12.5mm Gyproc FR board fixed on web of 45mm Gypliner channel section placed at 600mm centre to centre in 25mm gypliner angle including all accesseries and 25mm glasswool slab of density 24 Kg/m3 placed in metal frame work complete all as specified by manufacturer and as directed.
S&F for Fire rated PPGI pre-fabricated 50mm thick sandwich swing door of size 1.00 m x 2.10 m with PPGI frame of 1.6mm thick sheet , PPGI shutter sheet 1.2mm thick, filled with Rockwool 50mm thick with 3 hour fire rated with with following accessories :- (i) Warrington certified ball bearing stainless steel hinges. (i) D type stainless steel handle 150mm. (ii) 200mm x 300mm view glass. (iii) Dead lock & key. (iv) Door closure,
M&L 25 mm thick cement concrete type B-0,1:2:4 (12.5 mm graded aggregate) as in sub base of floors without extra cement, all as specified and as directed.
M&L for Screed bed or bedding layer of mortar 15mm thick in CM 1:6 for laying floor finishes, all as specified and as directed.
M&L Virified Ceramic tiles as light shade 10 mm thick (square/ rectangular)polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, all as specified and as directed.
M&L Virified Ceramic tiles as dark shade 10 mm thick (square/ rectangular)polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, all as specified and as directed.
M&L Virified Ceramic tiles as light shade 10 mm thick (square/ rectangular)polished, area of each tiles not exceeding 0.36 sqm, invertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, all as specified and as directed.
M & L Non-skid coloured ceramic floor tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, all as specified and as directed.
M & L Glazed coloured ceramic tiles in vertical surface 350x250x7mm/450x350x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, all as specified and as directed.
M & L for Cement concrete type C1, 1:3:6 (20mm graded stone aggregate) 75 mm thick as in Plinth protection including necessary form work as required, all as specified and directed
Removal of Plants/ Shrubs grown on walls/ slabs/beams by making holes or demolition of concrete etc and including applying suitable chemical for killing the roots of Plants, filling of holes with concrete and making good complete all as specified and directed.
Chipping/removing loose concrete in cloumns/beams/ chajjas/roof slab etc. up to reinforcement bars without damaging the reinforcement, removing all the loose material and to make all the exposed surface free from dust and all impurities etc complete all specified and directed.
Removing corrosion of steel reinforcement by mechanical means like wire brushing, chipping to remove loose rust and then applying rust removal solution Reebaklens RR of Fosroc / Sika Rust off 100 / equivalent in bostic India Ltd, by using brush application, leaving the surface for at least 15 to 30 minutes, then removing loose materials by scrubbing or with brush and applying anti corrosive coating to reinforcement Nitozinc primer of Fosroc/Sika Friazinc R / equivalent in Bostic india Ltd , all as recommended by product manufacturer.
Providing and applying one coat of structural grade epoxy coat by brush of approved make . Mixing of two components will be as directed by manufacturer .Application shall be provided not more than 5 hours before application of micro concrete/polymer mortar etc complete all as specified by the manufacturer. Make :- Nitobond EP of FOSROCK/ Sikdur 32LP/ equivalent in Bostic India Ltd
Providing and applying n exc 40 mm thick (In layers of each 10mm thick) Shrinkage controlled, polymer modified, fibre reinforced cementitious repair mortar Renderoc SP 40 of Fosroc / Sika plastocrete plus/ equivalent in bostic India ltd, mixed with water in a water & powder ratio 0.18 in ceiling of roof slab/Chajjas/Beams/Parapet walls etc . (Note :- Quoted rate is deemed to be inclusive of provideing scaffolding for working in patches upto a height of 15 Mtr complete all as specified and directed)
S&F in repairs Bib taps, brass chromium plated fancy type with cruch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore, all as specifed and directed.
S&F 20mm bore Gun-metal , globe or gate valve, with iron wheel head, screwed both ends for iron pipe fixed complete all as specified and directed.
S&F brass chromium plated health faucet with hand held and spring operated control valve with PVC flexible pipe connection of suitable length as directed fixed to 15 mm bore pipe, all as specifed and directed.
S&F in repairs vitreous china wash down water closet pan (Pedestal pattern), white including seat cover and flush pipe etc complete all as per specified and as directed.
S & F in repairs PVC valveless, syphonic action type, flushing cistern of 10 Ltrs capacity , low level , white, with inlet , ball valve, float and handle including brackets and flush pipe etc complete all as specified and as direted.
S& F in repair Vitreous China wash basin, white, flat back, size 450x300mm excluding taps, waste, chain and plug and porcelain stopper but including brackets including 32mmPTMT waste coupling complete all as specifed and directed.
S & F 110mm bore PVC (SWR) vent cowl, all as specifed and directed.
S & F PVC connections 15 mm size with PTMT nuts of length 450 mm, all as specifed and directed.
S&F in repairs chromium plated angle valves, cast copper alloy, screwed down high pressure with crutch or butterfly handles screwed both ends for iron pipes or for unions and fixed. 15 mm size, all as specifed and directed.
S&F in repairs Pillar taps fancy type cast copper alloy, with capstain head, chromium plated screwed down high pressure, with long shanks and fly nuts screwed for iron pipe and fixed 15 mm bore, all as specifed and directed.
M & L for PVC (SWR) multi floor trap of 75mm dia with grating including jointing with solvent cement etc complete,
S&F 16 mm dia 3- layer PP-R Polyproperlene random copolymer) concealed pipes SDR 7.4 (PN 16) UV stablized and antimicobial fusion welded having thermal stability for hot & cold water supply including all PPR plain & brass threaded Polyproplene random fittings fixed to walls, ceiling or in floors etc complete all as specified and directed.
S&F 20 mm dia 3- layer PP-R Polyproperlene random copolymer) concealed pipes SDR 7.4 (PN 16) UV stablized and antimicobial fusion welded having thermal stability for hot & cold water supply including all PPR plain & brass threaded Polyproplene random fittings fixed to walls, ceiling or in floors etc complete all as specified and directed.
S&F in repair 25 mm dia aluminium drapery rod with wooden finish, decorative, including brackets, decorative finials at both ends & curtain rings 8 Nos (minimum) complete all as specified and directed.
M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces with CM 1:4 as in backing coat of skirting /dado all as specified and directed.
M & L for Rendering in CM 1:6, 10mm thick on fair faces brick or concrete surfaces finished even and smooth without using extra cement, all as specified and directed.
M & L Rendering in CM 1:3, 5mm thick on fair faces of concrete surfaces on ceiling complete all as specified.
M & L for complete removal of existing treatment of wall, apply 3mm thick wall care putty, one coat of (chalk whiting) primer and two coat of oil bound distemper all as specified and as directed
Preparation of new wood or wood based surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, all as specifed and directed.
M & L for preparing new steel and iron surfaces of any description over 10 cm in width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide primer, all as specifed and directed.
M & L prepation of newly plastered wall surfaces, apply 3mm thick wall care putty and applying two coats of distemper oil emulsion over over a coat of primer all as specified and as directed.
M & L for prepation of old treated wall surfaces and applying one coat of oil bound distemper all as specified and directed
M & L for preparation of newly plastered surfaces and applying three coats of white wash on ceiling surface all as specified.
M&L for preparation of old surface and applying one coat of white wash on ceiling surface all as specified and directed .
M&L for Surface Point wiring one light point controlled by one, one way switch complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through in stove enmelled steel conduit with all accessories such as internal bend, end caps etc on surface of wall/ ceiling/roof/etc including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor with suitable screws for housing switches, socket outlets, fan regulators etc all as specified and as directed. (Note - Modular Metal box and modular plate with cover will be measured and paid separately)
All as per item No 63 herein before but one 05 Amps socket outlet point on same board.
M&L for Surface Point wiring one light point controlled by one, one way switch complete with 2.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through in stove enmelled steel conduit with all accessories such as internal bend, end caps etc on surface of wall/ ceiling/roof/etc including 2.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor with suitable screws for switch socket outlet point 5 Amps on independent board. etc all as specified and as directed. Note : Modular Metal box and modular plate with cover will be measured and paid separately
All as per item No. 65 here-in-before but with copper conductor cable FRLS, 4 Sqmm for one 3 pin socket outlet, 15 Amps and including 4 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board.
S&F Switch Modular 6A single pole, one way, 1 module complete all as specified and as directed.
S&F Switch Modular 16A single pole, one way, 1 module complete all as specified and as directed.
S&F Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed.
S&F socket Modular 6/16A 2/3 pin combined 2 module complete all as specified and as directed.
S&F White cover plate with frame 3 module, complete all as specified and as directed.
S&F White cover plate with frame 6 module, complete all as specified and as directed.
S&F Metal flush box 3 module, complete all as specified and as directed.
S&F Metal flush box 6 module, complete all as specified and as directed.
Supply and fixing LED lights fitting 2 x 22W, 220V,AC suitable twin LED light box type with down rod, driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED luminaire 600mmx600mm 35/36 watt, 220v AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holder & LED lamp suitable for false ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete
M&L for re-fixing split A/C of any Capacity in position providing foam heat insulation tube complete all as specified and as directed. Note :- The Split A/C removed against the item No 97 here-in-after shall be used for fixing .
M&L for re-fixing TPN DB of any Capacity in position alongwith MCCB/MCB complete all as specified and as directed. (Note :- The TPN DB removed against the item No 98 here-in-after shall be used for fixing)
S&F Sheet metal enclosure with socket plug top and MCB with single pole and neutral two pin and earth plug and socket complete with one single pole MCB 20 Amp, complete all as specified and as directed.
M&L for concealed Sub main wiring by making recess in wall/surface complete with 2 runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including Steel conduit and conduit accessories suface on wall/Ceiling etc from Main DB to MCB DB all as specified and as directed by engr - in- charge. (Note :- 2 runs of 6 sqmm, + 1 run of 6 sqmm as earth Cotinuity conductor and 1 run of PVC conduit shall be measured as one unit length)
Supply, installation & testing of maintenance free chemcal earthing of copper coated electrode pipe of length 3 mtr long and 76 mm dia, having terminal size 50x6 mm, the earth electrode pipe is tightly filled with Crystalline Conductive Mixture (CCM) and then sealed. The electrode shall be installed by making bore of 200 mm dia & 3 Mtr deep below normal ground level, after using & including 10 KG ground enhencing material, the electrode shall be surrounded by and including 60 KG Back Fill Compund (Chemical compound provided by manufaturer) complete including making earth pit chamber of size 30CM x 30 CM x 15 CM complete.
M&L for test point terminal block made of gun metal or phosphorous bronze size 75x75x25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw.
Material and Labour for XLPE insulated, armoured heavy duty fire cable with copper conductor, multi stranded, /1100 volts grade, cross-sectional area1.5 Sqmm,2 core with and including making connection by using necessary thimbles to existing Fire alarm control panel complete all as specified and directed
Supply and laid well burnt bricks sub-class 'B' designation 75 for cable protection, brick shall be laid dry flat as width of brick eqals to the length of cable and the gap between two adjacent brick shall not exceeded 10 mm, complete all as specified and as directed.
supply and fix deteactors complying with and type certified to EN -45 addressable type multi sensor detactor with heat and smoke combination
Demolition of Cement concrete in below or above ground level and paving not exc 15 cm thickness, all as specified and directed
Taking down shutters of any description n. exc 1.00 sqm each all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off the shutters from the frames) size not exc 1.50 sqm all as specified and directed.
Taking down chokhats or frames with shutters (without taking off the shutters from the frames) size exc 1.50 sqm but n exc 4 sqm all as specified and directed.
Taking down cement plaster on brick or stone walls, etc, including raking out joints, hacking for key, scrubbling down with water, etc all as specified and directed.
Dismantling floors, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises
Taking up or down steel tubing and connections, and removing to store for 15mm bore complete all as specified and directed.
Taking up or down steel tubing and connections, and removing to store for 20mm bore complete all as specified and directed.
Removing building material out side the campus including loading and unloading etc., to a distance exc 5.0 Km but not exc 10.0 Km out side the MD land ( Ministry of Defence) where responsibility regarding place of deposition and obtaining permission from all authorities etc., in this regard will be of contractor responsibility and all as specified.
Taking down old unserviceable point wiring (light, fan socket or power) complete, including fixture and fittings such as switches,ceiling rose, pendents, regulators,sockets, light fittings etc.removing materials for keeping for taking credit( credit for above items should be made as per conditions separately) and making good disturbed surface of walls floors etc. all as specified.
Taking down old unserviceable submain wiring of any size including GI/copper earth continuity conductor in PVC conduit on wall/roof and making good to disturbed surfaces all as directed.
Taking down split A/C of any Capacity and keeping it in safe custody for reuse at site and making good disturbed surfaces complete all as specified and as directed.
Disconnecting electric connection and taking down main switch/SPN DB/TPN DB of any size and keep in safe custody for reuse complete and good/levelling the disturbed surfaces of wall to match with existing surface.
Disconnecting removing of fire detactors of any specification including wirings for false ceiling repair work and refix the same in position including connection after the false ceiling repair work completed .
Sri ASK Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .